Summary
Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service.
CWE
  • CWE-20 - Improper Input Validation
References
Impacted products
Vendor Product Version CPE status
ABB ABB PB610 Panel Builder 600 Affected: unspecified , ≤ 2.8.0.424 (custom)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:02:39.901Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://search.abb.com/library/Download.aspx?DocumentID=3ADR010466\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ABB PB610 Panel Builder 600",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.8.0.424",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "NSFOCUS for providing vulnerability details and proof of concept."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 3.9,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-12-18T20:20:57.000Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://search.abb.com/library/Download.aspx?DocumentID=3ADR010466\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "advisory": "3ADR010466",
        "defect": [
          "ABBVU-RAMF-1908001"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "ABB PB610 HMIStudio crashes after launching an empty *.JPR application file",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "ID": "CVE-2019-18994",
          "STATE": "PUBLIC",
          "TITLE": "ABB PB610 HMIStudio crashes after launching an empty *.JPR application file"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ABB PB610 Panel Builder 600",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "2.8.0.424"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "NSFOCUS for providing vulnerability details and proof of concept."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 3.9,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20 Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://search.abb.com/library/Download.aspx?DocumentID=3ADR010466\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "http://search.abb.com/library/Download.aspx?DocumentID=3ADR010466\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "source": {
          "advisory": "3ADR010466",
          "defect": [
            "ABBVU-RAMF-1908001"
          ],
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2019-18994",
    "datePublished": "2019-12-18T20:20:57.000Z",
    "dateReserved": "2019-11-15T00:00:00.000Z",
    "dateUpdated": "2024-08-05T02:02:39.901Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2019-18994",
      "date": "2026-09-21",
      "epss": "0.00605",
      "percentile": "0.47352"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:abb:pb610_panel_builder_600:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2A9714CC-B58C-4D3E-A618-8C8146032D6B",
                    "versionEndIncluding": "2.8.0.424",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service."
          },
          {
            "lang": "es",
            "value": "Debido a la falta de comprobaci\u00f3n de la longitud del archivo, el componente HMIStudio de ABB PB610 Panel Builder 600 versiones 2.8.0.424 y anteriores, se bloquea al intentar cargar un archivo de aplicaci\u00f3n *.JPR vac\u00edo. Un atacante con acceso al sistema de archivos podr\u00eda ser capaz de causar un mal funcionamiento de la aplicaci\u00f3n, tal y como una denegaci\u00f3n de servicio."
          }
        ],
        "id": "CVE-2019-18994",
        "lastModified": "2024-11-21T04:33:57.503",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "LOW",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:N/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 6.8,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 3.9,
                "baseSeverity": "LOW",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 1.3,
              "impactScore": 2.5,
              "source": "cybersecurity@ch.abb.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2019-12-18T21:15:13.240",
        "references": [
          {
            "source": "cybersecurity@ch.abb.com",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "http://search.abb.com/library/Download.aspx?DocumentID=3ADR010466\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "http://search.abb.com/library/Download.aspx?DocumentID=3ADR010466\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "sourceIdentifier": "cybersecurity@ch.abb.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-20"
              }
            ],
            "source": "cybersecurity@ch.abb.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-20"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…