<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://db.gcve.eu/sightings/feed</id>
  <title>Most recent sightings.</title>
  <updated>2026-05-02T12:35:35.646580+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>info@gcve.eu</email>
  </author>
  <link href="https://db.gcve.eu" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent sightings.</subtitle>
  <entry>
    <id>https://db.gcve.eu/sighting/630c3bb9-2dfb-432b-8a10-07c6246998d1/export</id>
    <title>630c3bb9-2dfb-432b-8a10-07c6246998d1</title>
    <updated>2026-05-02T12:35:36.010062+00:00</updated>
    <author>
      <name>cedric</name>
      <uri>http://db.gcve.eu/user/cedric</uri>
    </author>
    <content>{"uuid": "630c3bb9-2dfb-432b-8a10-07c6246998d1", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "2a075640-a300-48a4-bb44-bc6130783b9b", "vulnerability": "CVE-2024-35522", "type": "seen", "source": "https://t.me/cvedetector/7752", "content": "{\n  \"Source\": \"CVE FEED\",\n  \"Title\": \"CVE-2024-35522 - Netgear EX3700 Command Injection\", \n  \"Content\": \"CVE ID : CVE-2024-35522 \nPublished : Oct. 11, 2024, 10:15 p.m. | 44\u00a0minutes ago \nDescription : Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone. \nSeverity: 8.4 | HIGH \nVisit the link for more details, such as CVSS details, affected products, timeline, and more...\",\n  \"Detection Date\": \"12 Oct 2024\",\n  \"Type\": \"Vulnerability\"\n}\n\ud83d\udd39 t.me/cvedetector \ud83d\udd39", "creation_timestamp": "2024-10-12T01:05:52.000000Z"}</content>
    <link href="https://db.gcve.eu/sighting/630c3bb9-2dfb-432b-8a10-07c6246998d1/export"/>
    <published>2024-10-12T01:05:52+00:00</published>
  </entry>
  <entry>
    <id>https://db.gcve.eu/sighting/2e09bb09-7a37-4e8d-90dd-ade6e47f32b5/export</id>
    <title>2e09bb09-7a37-4e8d-90dd-ade6e47f32b5</title>
    <updated>2026-05-02T12:35:36.008735+00:00</updated>
    <author>
      <name>cedric</name>
      <uri>http://db.gcve.eu/user/cedric</uri>
    </author>
    <content>{"uuid": "2e09bb09-7a37-4e8d-90dd-ade6e47f32b5", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "2a075640-a300-48a4-bb44-bc6130783b9b", "vulnerability": "CVE-2024-35522", "type": "published-proof-of-concept", "source": "https://t.me/DarkWebInformer_CVEAlerts/7436", "content": "\ud83d\udd17 DarkWebInformer.com - Cyber Threat Intelligence\n\ud83d\udccc CVE ID: CVE-2024-35522\n\ud83d\udd25 CVSS Score: 8.4 (cvssV3_1, Vector: CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N)\n\ud83d\udd39 Description: Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.\n\ud83d\udccf Published: 2024-10-11T00:00:00.000Z\n\ud83d\udccf Modified: 2025-03-13T16:22:22.580Z\n\ud83d\udd17 References:\n1. https://github.com/consrc/cves/blob/main/CVE-2024-35522.md", "creation_timestamp": "2025-03-13T16:45:33.000000Z"}</content>
    <link href="https://db.gcve.eu/sighting/2e09bb09-7a37-4e8d-90dd-ade6e47f32b5/export"/>
    <published>2025-03-13T16:45:33+00:00</published>
  </entry>
</feed>
