{"uuid": "684ca3cc-dbec-4271-a19f-25284c252979", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "2a075640-a300-48a4-bb44-bc6130783b9b", "vulnerability": "CVE-2025-22961", "type": "published-proof-of-concept", "source": "https://t.me/DarkWebInformer_CVEAlerts/4389", "content": "\ud83d\udd17 DarkWebInformer.com - Cyber Threat Intelligence\n\ud83d\udccc CVE ID: CVE-2025-22961\n\ud83d\udd25 CVSS Score: N/A\n\ud83d\udd39 Description: A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise.\n\ud83d\udccf Published: 2025-02-14T00:30:45Z\n\ud83d\udccf Modified: 2025-02-14T00:30:45Z\n\ud83d\udd17 References:\n1. https://nvd.nist.gov/vuln/detail/CVE-2025-22961\n2. https://github.com/shiky8/my--cve-vulnerability-research/tree/main/CVE-2025-22961", "creation_timestamp": "2025-02-14T01:14:07.000000Z"}