CVE-2019-6857 (GCVE-0-2019-6857)

Vulnerability from nvd – Published: 2020-01-06 22:57 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.
Severity ?
No CVSS data available.
CWE
  • CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) Affected: Modicon M580
Affected: Modicon M340
Affected: Modicon Quantum
Affected: Modicon Premium (see security notification for specific versions)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.438Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "Modicon M580"
            },
            {
              "status": "affected",
              "version": "Modicon M340"
            },
            {
              "status": "affected",
              "version": "Modicon Quantum"
            },
            {
              "status": "affected",
              "version": "Modicon Premium (see security notification for specific versions)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-21T23:03:43.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2019-6857",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Modicon M580"
                          },
                          {
                            "version_value": "Modicon M340"
                          },
                          {
                            "version_value": "Modicon Quantum"
                          },
                          {
                            "version_value": "Modicon Premium (see security notification for specific versions)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
              "refsource": "CONFIRM",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2019-6857",
    "datePublished": "2020-01-06T22:57:05.000Z",
    "dateReserved": "2019-01-25T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.438Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6856 (GCVE-0-2019-6856)

Vulnerability from nvd – Published: 2020-01-06 22:57 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
Severity ?
No CVSS data available.
CWE
  • CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) Affected: Modicon M580
Affected: Modicon M340
Affected: Modicon Quantum
Affected: Modicon Premium (see security notification for specific versions)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.415Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "Modicon M580"
            },
            {
              "status": "affected",
              "version": "Modicon M340"
            },
            {
              "status": "affected",
              "version": "Modicon Quantum"
            },
            {
              "status": "affected",
              "version": "Modicon Premium (see security notification for specific versions)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-21T23:04:36.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2019-6856",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Modicon M580"
                          },
                          {
                            "version_value": "Modicon M340"
                          },
                          {
                            "version_value": "Modicon Quantum"
                          },
                          {
                            "version_value": "Modicon Premium (see security notification for specific versions)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
              "refsource": "CONFIRM",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2019-6856",
    "datePublished": "2020-01-06T22:57:02.000Z",
    "dateReserved": "2019-01-25T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.415Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7794 (GCVE-0-2018-7794)

Vulnerability from nvd – Published: 2020-01-06 22:57 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP.
Severity ?
No CVSS data available.
CWE
  • CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) Affected: Modicon M580
Affected: Modicon M340
Affected: Modicon Quantum
Affected: Modicon Premium (see security notification for specific versions)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.272Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "Modicon M580"
            },
            {
              "status": "affected",
              "version": "Modicon M340"
            },
            {
              "status": "affected",
              "version": "Modicon Quantum"
            },
            {
              "status": "affected",
              "version": "Modicon Premium (see security notification for specific versions)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-06T22:57:09.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2018-7794",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Modicon M580"
                          },
                          {
                            "version_value": "Modicon M340"
                          },
                          {
                            "version_value": "Modicon Quantum"
                          },
                          {
                            "version_value": "Modicon Premium (see security notification for specific versions)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
              "refsource": "CONFIRM",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7794",
    "datePublished": "2020-01-06T22:57:09.000Z",
    "dateReserved": "2018-03-08T00:00:00.000Z",
    "dateUpdated": "2024-08-05T06:37:59.272Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7794 (GCVE-0-2018-7794)

Vulnerability from cvelistv5 – Published: 2020-01-06 22:57 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP.
Severity ?
No CVSS data available.
CWE
  • CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) Affected: Modicon M580
Affected: Modicon M340
Affected: Modicon Quantum
Affected: Modicon Premium (see security notification for specific versions)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.272Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "Modicon M580"
            },
            {
              "status": "affected",
              "version": "Modicon M340"
            },
            {
              "status": "affected",
              "version": "Modicon Quantum"
            },
            {
              "status": "affected",
              "version": "Modicon Premium (see security notification for specific versions)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-06T22:57:09.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2018-7794",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Modicon M580"
                          },
                          {
                            "version_value": "Modicon M340"
                          },
                          {
                            "version_value": "Modicon Quantum"
                          },
                          {
                            "version_value": "Modicon Premium (see security notification for specific versions)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
              "refsource": "CONFIRM",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7794",
    "datePublished": "2020-01-06T22:57:09.000Z",
    "dateReserved": "2018-03-08T00:00:00.000Z",
    "dateUpdated": "2024-08-05T06:37:59.272Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6857 (GCVE-0-2019-6857)

Vulnerability from cvelistv5 – Published: 2020-01-06 22:57 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.
Severity ?
No CVSS data available.
CWE
  • CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) Affected: Modicon M580
Affected: Modicon M340
Affected: Modicon Quantum
Affected: Modicon Premium (see security notification for specific versions)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.438Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "Modicon M580"
            },
            {
              "status": "affected",
              "version": "Modicon M340"
            },
            {
              "status": "affected",
              "version": "Modicon Quantum"
            },
            {
              "status": "affected",
              "version": "Modicon Premium (see security notification for specific versions)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-21T23:03:43.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2019-6857",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Modicon M580"
                          },
                          {
                            "version_value": "Modicon M340"
                          },
                          {
                            "version_value": "Modicon Quantum"
                          },
                          {
                            "version_value": "Modicon Premium (see security notification for specific versions)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
              "refsource": "CONFIRM",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2019-6857",
    "datePublished": "2020-01-06T22:57:05.000Z",
    "dateReserved": "2019-01-25T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.438Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6856 (GCVE-0-2019-6856)

Vulnerability from cvelistv5 – Published: 2020-01-06 22:57 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
Severity ?
No CVSS data available.
CWE
  • CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) Affected: Modicon M580
Affected: Modicon M340
Affected: Modicon Quantum
Affected: Modicon Premium (see security notification for specific versions)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.415Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "Modicon M580"
            },
            {
              "status": "affected",
              "version": "Modicon M340"
            },
            {
              "status": "affected",
              "version": "Modicon Quantum"
            },
            {
              "status": "affected",
              "version": "Modicon Premium (see security notification for specific versions)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-21T23:04:36.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2019-6856",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Modicon M580, Modicon M340, Modicon Quantum,  Modicon Premium (see security notification for specific versions)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Modicon M580"
                          },
                          {
                            "version_value": "Modicon M340"
                          },
                          {
                            "version_value": "Modicon Quantum"
                          },
                          {
                            "version_value": "Modicon Premium (see security notification for specific versions)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01",
              "refsource": "CONFIRM",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2019-6856",
    "datePublished": "2020-01-06T22:57:02.000Z",
    "dateReserved": "2019-01-25T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.415Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}