VAR-201710-1311
Vulnerability from variot - Updated: 2025-04-20 23:23Ruckus Wireless Zone Director Controller firmware releases ZD9.x, ZD10.0.0.x, ZD10.0.1.x (less than 10.0.1.0.17 MR1 release) and Ruckus Wireless Unleashed AP Firmware releases 200.0.x, 200.1.x, 200.2.x, 200.3.x, 200.4.x. contain OS Command Injection vulnerabilities that could allow local authenticated users to execute arbitrary privileged commands on the underlying operating system by appending those commands in the Common Name field in the Certificate Generation Request. A local attacker could exploit this vulnerability to execute arbitrary commands
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201710-1311",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "unleashed",
"scope": "eq",
"trust": 1.6,
"vendor": "ruckuswireless",
"version": "200.1"
},
{
"model": "zonedirector",
"scope": "eq",
"trust": 1.6,
"vendor": "ruckuswireless",
"version": "zd9.9.0.0.212"
},
{
"model": "unleashed",
"scope": "eq",
"trust": 1.6,
"vendor": "ruckuswireless",
"version": "200.1.9.12.55"
},
{
"model": "unleashed",
"scope": "eq",
"trust": 1.6,
"vendor": "ruckuswireless",
"version": "200.3"
},
{
"model": "zonedirector",
"scope": "eq",
"trust": 1.6,
"vendor": "ruckuswireless",
"version": "zd9.10.0.0.218"
},
{
"model": "zonedirector",
"scope": "eq",
"trust": 1.6,
"vendor": "ruckuswireless",
"version": "zd9.9.0.0.216"
},
{
"model": "unleashed",
"scope": "eq",
"trust": 1.6,
"vendor": "ruckuswireless",
"version": "200.3.9.13.228"
},
{
"model": "zonedirector",
"scope": "eq",
"trust": 1.6,
"vendor": "ruckuswireless",
"version": "zd9.9.0.0.205"
},
{
"model": "zonedirector",
"scope": "eq",
"trust": 1.6,
"vendor": "ruckuswireless",
"version": "zd9.13.0.0.103"
},
{
"model": "zonedirector",
"scope": "eq",
"trust": 1.6,
"vendor": "ruckuswireless",
"version": "zd9.13.0.0.209"
},
{
"model": "unleashed",
"scope": "eq",
"trust": 1.0,
"vendor": "ruckuswireless",
"version": "200.4.9.13"
},
{
"model": "unleashed",
"scope": "eq",
"trust": 1.0,
"vendor": "ruckuswireless",
"version": "200.4.9.13.47"
},
{
"model": "unleashed",
"scope": null,
"trust": 0.8,
"vendor": "ruckus",
"version": null
},
{
"model": "zonedirector",
"scope": null,
"trust": 0.8,
"vendor": "ruckus",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-009284"
},
{
"db": "CNNVD",
"id": "CNNVD-201702-812"
},
{
"db": "NVD",
"id": "CVE-2017-6224"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:ruckus_wireless:unleashed_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:ruckus_wireless:zonedirector_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-009284"
}
]
},
"cve": "CVE-2017-6224",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "CVE-2017-6224",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "VHN-114427",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2017-6224",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-6224",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2017-6224",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-201702-812",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-114427",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-114427"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009284"
},
{
"db": "CNNVD",
"id": "CNNVD-201702-812"
},
{
"db": "NVD",
"id": "CVE-2017-6224"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ruckus Wireless Zone Director Controller firmware releases ZD9.x, ZD10.0.0.x, ZD10.0.1.x (less than 10.0.1.0.17 MR1 release) and Ruckus Wireless Unleashed AP Firmware releases 200.0.x, 200.1.x, 200.2.x, 200.3.x, 200.4.x. contain OS Command Injection vulnerabilities that could allow local authenticated users to execute arbitrary privileged commands on the underlying operating system by appending those commands in the Common Name field in the Certificate Generation Request. A local attacker could exploit this vulnerability to execute arbitrary commands",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-6224"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009284"
},
{
"db": "VULHUB",
"id": "VHN-114427"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-6224",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009284",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201702-812",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-114427",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-114427"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009284"
},
{
"db": "CNNVD",
"id": "CNNVD-201702-812"
},
{
"db": "NVD",
"id": "CVE-2017-6224"
}
]
},
"id": "VAR-201710-1311",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-114427"
}
],
"trust": 0.01
},
"last_update_date": "2025-04-20T23:23:34.256000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Ruckus Unleashed",
"trust": 0.8,
"url": "https://www.ruckuswireless.com/ja/products/system-management-control/unleashed"
},
{
"title": "ZoneDirector",
"trust": 0.8,
"url": "https://www.ruckuswireless.com/ja/products/system-management-control/zonedirector-controllers"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-009284"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.1
},
{
"problemtype": "CWE-77",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-114427"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009284"
},
{
"db": "NVD",
"id": "CVE-2017-6224"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-092917.txt"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-6224"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-6224"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-114427"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009284"
},
{
"db": "CNNVD",
"id": "CNNVD-201702-812"
},
{
"db": "NVD",
"id": "CVE-2017-6224"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-114427"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009284"
},
{
"db": "CNNVD",
"id": "CNNVD-201702-812"
},
{
"db": "NVD",
"id": "CVE-2017-6224"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-10-13T00:00:00",
"db": "VULHUB",
"id": "VHN-114427"
},
{
"date": "2017-11-08T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-009284"
},
{
"date": "2017-02-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201702-812"
},
{
"date": "2017-10-13T17:29:01.160000",
"db": "NVD",
"id": "CVE-2017-6224"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-03T00:00:00",
"db": "VULHUB",
"id": "VHN-114427"
},
{
"date": "2017-11-08T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-009284"
},
{
"date": "2019-10-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201702-812"
},
{
"date": "2025-04-20T01:37:25.860000",
"db": "NVD",
"id": "CVE-2017-6224"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201702-812"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ruckus Wireless Zone Director Controller and Unleashed AP Command injection vulnerability in some firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-009284"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201702-812"
}
],
"trust": 0.6
}
}