VAR-201711-0046
Vulnerability from variot - Updated: 2025-04-20 23:40The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements. Philips IntelliSpace Cardiovascular (ISCV) and Xcelera Contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Philips IntelliSpace Cardiovascular and Xcelera systems (the predecessor to IntelliSpace Cardiovascular) are comprehensive cardiac imaging and information management software. A plaintext storage vulnerability exists in the Philips IntelliSpace Cardiovascular System and Xcelera System. Credentials are stored in clear file in system files, resulting in highly privileged attackers gaining unauthorized access to data, including patient health information, system resources, and misuse connections. assets. this may lead to further attacks. Xcelera is its predecessor. The vulnerability is caused by the program storing certificates in clear text in system files
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201711-0046",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "intellispace cardiovascular",
"scope": "lte",
"trust": 1.8,
"vendor": "philips",
"version": "2.3.0"
},
{
"model": "xcelera",
"scope": "lte",
"trust": 1.8,
"vendor": "philips",
"version": "r4.1l1"
},
{
"model": "intellispace cardiovascular",
"scope": "lte",
"trust": 0.6,
"vendor": "philips",
"version": "\u003c=2.3.0"
},
{
"model": "xcelera \u003c=r4.1l1",
"scope": null,
"trust": 0.6,
"vendor": "philips",
"version": null
},
{
"model": "xcelera",
"scope": "eq",
"trust": 0.6,
"vendor": "philips",
"version": "r4.1l1"
},
{
"model": "intellispace cardiovascular",
"scope": "eq",
"trust": 0.6,
"vendor": "philips",
"version": "2.3.0"
},
{
"model": "xcelera r4.1l1",
"scope": null,
"trust": 0.3,
"vendor": "philips",
"version": null
},
{
"model": "intellispace cardiovascular",
"scope": "eq",
"trust": 0.3,
"vendor": "philips",
"version": "2.3"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "intellispace cardiovascular",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "xcelera",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "01f9d4b4-bdcf-49bf-83aa-05b63da7e5ea"
},
{
"db": "CNVD",
"id": "CNVD-2017-34035"
},
{
"db": "BID",
"id": "101850"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010491"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-015"
},
{
"db": "NVD",
"id": "CVE-2017-14111"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:philips:intellispace_cardiovascular",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:philips:xcelera",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-010491"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The vendor reported this issue.",
"sources": [
{
"db": "BID",
"id": "101850"
}
],
"trust": 0.3
},
"cve": "CVE-2017-14111",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2017-14111",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2017-34035",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "01f9d4b4-bdcf-49bf-83aa-05b63da7e5ea",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "VHN-104801",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2017-14111",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-14111",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2017-14111",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2017-34035",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201709-015",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "01f9d4b4-bdcf-49bf-83aa-05b63da7e5ea",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-104801",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "01f9d4b4-bdcf-49bf-83aa-05b63da7e5ea"
},
{
"db": "CNVD",
"id": "CNVD-2017-34035"
},
{
"db": "VULHUB",
"id": "VHN-104801"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010491"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-015"
},
{
"db": "NVD",
"id": "CVE-2017-14111"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements. Philips IntelliSpace Cardiovascular (ISCV) and Xcelera Contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Philips IntelliSpace Cardiovascular and Xcelera systems (the predecessor to IntelliSpace Cardiovascular) are comprehensive cardiac imaging and information management software. A plaintext storage vulnerability exists in the Philips IntelliSpace Cardiovascular System and Xcelera System. Credentials are stored in clear file in system files, resulting in highly privileged attackers gaining unauthorized access to data, including patient health information, system resources, and misuse connections. assets. this may lead to further attacks. Xcelera is its predecessor. The vulnerability is caused by the program storing certificates in clear text in system files",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-14111"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010491"
},
{
"db": "CNVD",
"id": "CNVD-2017-34035"
},
{
"db": "BID",
"id": "101850"
},
{
"db": "IVD",
"id": "01f9d4b4-bdcf-49bf-83aa-05b63da7e5ea"
},
{
"db": "VULHUB",
"id": "VHN-104801"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-14111",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSMA-17-318-01",
"trust": 3.4
},
{
"db": "BID",
"id": "101850",
"trust": 2.0
},
{
"db": "CNNVD",
"id": "CNNVD-201709-015",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2017-34035",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010491",
"trust": 0.8
},
{
"db": "IVD",
"id": "01F9D4B4-BDCF-49BF-83AA-05B63DA7E5EA",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-104801",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "01f9d4b4-bdcf-49bf-83aa-05b63da7e5ea"
},
{
"db": "CNVD",
"id": "CNVD-2017-34035"
},
{
"db": "VULHUB",
"id": "VHN-104801"
},
{
"db": "BID",
"id": "101850"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010491"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-015"
},
{
"db": "NVD",
"id": "CVE-2017-14111"
}
]
},
"id": "VAR-201711-0046",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "01f9d4b4-bdcf-49bf-83aa-05b63da7e5ea"
},
{
"db": "CNVD",
"id": "CNVD-2017-34035"
},
{
"db": "VULHUB",
"id": "VHN-104801"
}
],
"trust": 1.33995098
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "01f9d4b4-bdcf-49bf-83aa-05b63da7e5ea"
},
{
"db": "CNVD",
"id": "CNVD-2017-34035"
}
]
},
"last_update_date": "2025-04-20T23:40:00.135000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "CUSTOMER INFORMATION on IntelliSpace Cardiovascular and Xcelera Vulnerabilities",
"trust": 0.8,
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"title": "Philips IntelliSpace Cardiovascular and Xcelera Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=76098"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-010491"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-015"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-522",
"trust": 1.1
},
{
"problemtype": "CWE-255",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-104801"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010491"
},
{
"db": "NVD",
"id": "CVE-2017-14111"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.4,
"url": "https://ics-cert.us-cert.gov/advisories/icsma-17-318-01"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/101850"
},
{
"trust": 1.7,
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-14111"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-14111"
},
{
"trust": 0.3,
"url": "http://www.isssource.com/philips-clears-hole-in-medical-systems/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-34035"
},
{
"db": "VULHUB",
"id": "VHN-104801"
},
{
"db": "BID",
"id": "101850"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010491"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-015"
},
{
"db": "NVD",
"id": "CVE-2017-14111"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "01f9d4b4-bdcf-49bf-83aa-05b63da7e5ea"
},
{
"db": "CNVD",
"id": "CNVD-2017-34035"
},
{
"db": "VULHUB",
"id": "VHN-104801"
},
{
"db": "BID",
"id": "101850"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010491"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-015"
},
{
"db": "NVD",
"id": "CVE-2017-14111"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-11-16T00:00:00",
"db": "IVD",
"id": "01f9d4b4-bdcf-49bf-83aa-05b63da7e5ea"
},
{
"date": "2017-11-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-34035"
},
{
"date": "2017-11-17T00:00:00",
"db": "VULHUB",
"id": "VHN-104801"
},
{
"date": "2017-11-14T00:00:00",
"db": "BID",
"id": "101850"
},
{
"date": "2017-12-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-010491"
},
{
"date": "2017-11-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201709-015"
},
{
"date": "2017-11-17T20:29:00.323000",
"db": "NVD",
"id": "CVE-2017-14111"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-11-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-34035"
},
{
"date": "2019-10-03T00:00:00",
"db": "VULHUB",
"id": "VHN-104801"
},
{
"date": "2017-12-19T22:37:00",
"db": "BID",
"id": "101850"
},
{
"date": "2017-12-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-010491"
},
{
"date": "2019-10-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201709-015"
},
{
"date": "2025-04-20T01:37:25.860000",
"db": "NVD",
"id": "CVE-2017-14111"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201709-015"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Philips IntelliSpace Cardiovascular and Xcelera Vulnerabilities related to certificate and password management",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-010491"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201709-015"
}
],
"trust": 0.6
}
}
VAR-201808-0377
Vulnerability from variot - Updated: 2024-11-23 22:22In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges. Philips IntelliSpace Cardiovascular (ISCV) and Xcelera Contains an unquoted search path or element vulnerability.Information is acquired, information is falsified, and denial of service (DoS) May be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201808-0377",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "xcelera",
"scope": "lte",
"trust": 1.0,
"vendor": "philips",
"version": "4.1"
},
{
"model": "intellispace cardiovascular",
"scope": "lte",
"trust": 1.0,
"vendor": "philips",
"version": "3.1"
},
{
"model": "intellispace cardiovascular",
"scope": "lte",
"trust": 0.8,
"vendor": "phillips",
"version": "3.1"
},
{
"model": "xcelera",
"scope": "lte",
"trust": 0.8,
"vendor": "phillips",
"version": "4.1"
},
{
"model": "xcelera",
"scope": "eq",
"trust": 0.6,
"vendor": "phillips",
"version": "4.1"
},
{
"model": "intellispace cardiovascular",
"scope": "eq",
"trust": 0.6,
"vendor": "phillips",
"version": "3.1"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009872"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-633"
},
{
"db": "NVD",
"id": "CVE-2018-14789"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:philips:intellispace_cardiovascular",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:philips:xcelera",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009872"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Philips",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-633"
}
],
"trust": 0.6
},
"cve": "CVE-2018-14789",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CVE-2018-14789",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.8,
"id": "CVE-2018-14789",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.7,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-14789",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-14789",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2018-14789",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-201808-633",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009872"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-633"
},
{
"db": "NVD",
"id": "CVE-2018-14789"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "In Philips\u0027 IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges. Philips IntelliSpace Cardiovascular (ISCV) and Xcelera Contains an unquoted search path or element vulnerability.Information is acquired, information is falsified, and denial of service (DoS) May be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14789"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009872"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT",
"id": "ICSMA-18-226-01",
"trust": 2.4
},
{
"db": "NVD",
"id": "CVE-2018-14789",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009872",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201808-633",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009872"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-633"
},
{
"db": "NVD",
"id": "CVE-2018-14789"
}
]
},
"id": "VAR-201808-0377",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.43995098
},
"last_update_date": "2024-11-23T22:22:01.322000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Philips IntelliSpace Cardiovascular (ISCV) and Xcelera (14-Aug-2018)",
"trust": 0.8,
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009872"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-428",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009872"
},
{
"db": "NVD",
"id": "CVE-2018-14789"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://ics-cert.us-cert.gov/advisories/icsma-18-226-01"
},
{
"trust": 1.6,
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14789"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-14789"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009872"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-633"
},
{
"db": "NVD",
"id": "CVE-2018-14789"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009872"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-633"
},
{
"db": "NVD",
"id": "CVE-2018-14789"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-11-30T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-009872"
},
{
"date": "2018-08-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-633"
},
{
"date": "2018-08-22T18:29:00.433000",
"db": "NVD",
"id": "CVE-2018-14789"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-11-30T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-009872"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-633"
},
{
"date": "2024-11-21T03:49:47.833000",
"db": "NVD",
"id": "CVE-2018-14789"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-633"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Philips IntelliSpace Cardiovascular and Xcelera Vulnerable to unquoted search paths or elements",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009872"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "code problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-633"
}
],
"trust": 0.6
}
}
VAR-201808-0376
Vulnerability from variot - Updated: 2024-11-23 22:22In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions. Philips IntelliSpace Cardiovascular (ISCV) and Xcelera Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Philips IntelliSpace Cardiovascular (ISCV) and Xcelera are both products of Philips in the Netherlands. Philips ISCV is a cardiac imaging information management system. Xcelera is its predecessor.
There are security vulnerabilities in Philips ISCV 2.x and earlier versions and Xcelera 4.1 and earlier versions. The vulnerabilities are caused by the failure of the program to perform proper rights management
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201808-0376",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "xcelera",
"scope": "lte",
"trust": 1.8,
"vendor": "philips",
"version": "4.1"
},
{
"model": "intellispace cardiovascular",
"scope": "lte",
"trust": 1.0,
"vendor": "philips",
"version": "3.1"
},
{
"model": "intellispace cardiovascular",
"scope": "lte",
"trust": 0.8,
"vendor": "philips",
"version": "2.x"
},
{
"model": "intellispace cardiovascular",
"scope": "lte",
"trust": 0.6,
"vendor": "philips",
"version": "\u003c=2.*"
},
{
"model": "xcelera",
"scope": "lte",
"trust": 0.6,
"vendor": "philips",
"version": "\u003c=4.1"
},
{
"model": "xcelera",
"scope": "eq",
"trust": 0.6,
"vendor": "phillips",
"version": "4.1"
},
{
"model": "intellispace cardiovascular",
"scope": "eq",
"trust": 0.6,
"vendor": "phillips",
"version": "3.1"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-53791"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009945"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-632"
},
{
"db": "NVD",
"id": "CVE-2018-14787"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:philips:intellispace_cardiovascular",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:philips:xcelera",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009945"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Philips",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-632"
}
],
"trust": 0.6
},
"cve": "CVE-2018-14787",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CVE-2018-14787",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CNVD-2020-53791",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2018-14787",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-14787",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-14787",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2018-14787",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2020-53791",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201808-632",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-53791"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009945"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-632"
},
{
"db": "NVD",
"id": "CVE-2018-14787"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "In Philips\u0027 IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions. Philips IntelliSpace Cardiovascular (ISCV) and Xcelera Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Philips IntelliSpace Cardiovascular (ISCV) and Xcelera are both products of Philips in the Netherlands. Philips ISCV is a cardiac imaging information management system. Xcelera is its predecessor. \n\r\n\r\nThere are security vulnerabilities in Philips ISCV 2.x and earlier versions and Xcelera 4.1 and earlier versions. The vulnerabilities are caused by the failure of the program to perform proper rights management",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14787"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009945"
},
{
"db": "CNVD",
"id": "CNVD-2020-53791"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-14787",
"trust": 3.0
},
{
"db": "ICS CERT",
"id": "ICSMA-18-226-01",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009945",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-53791",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201808-632",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-53791"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009945"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-632"
},
{
"db": "NVD",
"id": "CVE-2018-14787"
}
]
},
"id": "VAR-201808-0376",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-53791"
}
],
"trust": 1.03995098
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-53791"
}
]
},
"last_update_date": "2024-11-23T22:22:01.295000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Philips IntelliSpace Cardiovascular (ISCV) and Xcelera (14-Aug-2018)",
"trust": 0.8,
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"title": "Philips IntelliSpace Cardiovascular and Xcelera Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84228"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009945"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-632"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-269",
"trust": 1.0
},
{
"problemtype": "CWE-264",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009945"
},
{
"db": "NVD",
"id": "CVE-2018-14787"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://ics-cert.us-cert.gov/advisories/icsma-18-226-01"
},
{
"trust": 1.6,
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-14787"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14787"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-53791"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009945"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-632"
},
{
"db": "NVD",
"id": "CVE-2018-14787"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-53791"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009945"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-632"
},
{
"db": "NVD",
"id": "CVE-2018-14787"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-09-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-53791"
},
{
"date": "2018-11-30T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-009945"
},
{
"date": "2018-08-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-632"
},
{
"date": "2018-08-22T18:29:00.340000",
"db": "NVD",
"id": "CVE-2018-14787"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-09-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-53791"
},
{
"date": "2018-11-30T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-009945"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-632"
},
{
"date": "2024-11-21T03:49:47.560000",
"db": "NVD",
"id": "CVE-2018-14787"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-632"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Philips IntelliSpace Cardiovascular and Xcelera Vulnerabilities related to authorization, permissions, and access control",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009945"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "permissions and access control issues",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-632"
}
],
"trust": 0.6
}
}
CVE-2018-14789 (GCVE-0-2018-14789)
Vulnerability from nvd – Published: 2018-08-22 18:00 – Updated: 2024-09-16 17:18- CWE-428 - UNQUOTED SEARCH PATH OR ELEMENT CWE-428
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Philips | IntelliSpace Cardiovascular (ISCV) products |
Affected:
IntelliSpace Cardiovascular, Version 3.1 or prior
Affected: Xcelera Version 4.1 or prior |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:38:13.980Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IntelliSpace Cardiovascular (ISCV) products",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "IntelliSpace Cardiovascular, Version 3.1 or prior"
},
{
"status": "affected",
"version": "Xcelera Version 4.1 or prior"
}
]
}
],
"datePublic": "2018-08-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In Philips\u0027 IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "UNQUOTED SEARCH PATH OR ELEMENT CWE-428",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-22T17:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-08-14T00:00:00",
"ID": "CVE-2018-14789",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IntelliSpace Cardiovascular (ISCV) products",
"version": {
"version_data": [
{
"version_value": "IntelliSpace Cardiovascular, Version 3.1 or prior"
},
{
"version_value": "Xcelera Version 4.1 or prior"
}
]
}
}
]
},
"vendor_name": "Philips"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Philips\u0027 IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "UNQUOTED SEARCH PATH OR ELEMENT CWE-428"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"refsource": "CONFIRM",
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-14789",
"datePublished": "2018-08-22T18:00:00Z",
"dateReserved": "2018-08-01T00:00:00",
"dateUpdated": "2024-09-16T17:18:12.900Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-14787 (GCVE-0-2018-14787)
Vulnerability from nvd – Published: 2018-08-22 18:00 – Updated: 2024-09-16 18:59- CWE-269 - IMPROPER PRIVILEGE MANAGEMENT CWE-269
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Philips | IntelliSpace Cardiovascular (ISCV) products |
Affected:
IntelliSpace Cardiovascular, Version 3.1 or prior
Affected: Xcelera Version 4.1 or prior |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:38:13.911Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IntelliSpace Cardiovascular (ISCV) products",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "IntelliSpace Cardiovascular, Version 3.1 or prior"
},
{
"status": "affected",
"version": "Xcelera Version 4.1 or prior"
}
]
}
],
"datePublic": "2018-08-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In Philips\u0027 IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "IMPROPER PRIVILEGE MANAGEMENT CWE-269",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-22T17:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-08-14T00:00:00",
"ID": "CVE-2018-14787",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IntelliSpace Cardiovascular (ISCV) products",
"version": {
"version_data": [
{
"version_value": "IntelliSpace Cardiovascular, Version 3.1 or prior"
},
{
"version_value": "Xcelera Version 4.1 or prior"
}
]
}
}
]
},
"vendor_name": "Philips"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Philips\u0027 IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER PRIVILEGE MANAGEMENT CWE-269"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"refsource": "CONFIRM",
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-14787",
"datePublished": "2018-08-22T18:00:00Z",
"dateReserved": "2018-08-01T00:00:00",
"dateUpdated": "2024-09-16T18:59:28.155Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-14111 (GCVE-0-2017-14111)
Vulnerability from nvd – Published: 2017-11-17 20:00 – Updated: 2024-08-05 19:20- n/a
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T19:20:41.262Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "101850",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/101850"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-318-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-11-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-11-17T19:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "101850",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/101850"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-318-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-14111",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"refsource": "CONFIRM",
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "101850",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/101850"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-318-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-318-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-14111",
"datePublished": "2017-11-17T20:00:00",
"dateReserved": "2017-09-01T00:00:00",
"dateUpdated": "2024-08-05T19:20:41.262Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-14787 (GCVE-0-2018-14787)
Vulnerability from cvelistv5 – Published: 2018-08-22 18:00 – Updated: 2024-09-16 18:59- CWE-269 - IMPROPER PRIVILEGE MANAGEMENT CWE-269
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Philips | IntelliSpace Cardiovascular (ISCV) products |
Affected:
IntelliSpace Cardiovascular, Version 3.1 or prior
Affected: Xcelera Version 4.1 or prior |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:38:13.911Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IntelliSpace Cardiovascular (ISCV) products",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "IntelliSpace Cardiovascular, Version 3.1 or prior"
},
{
"status": "affected",
"version": "Xcelera Version 4.1 or prior"
}
]
}
],
"datePublic": "2018-08-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In Philips\u0027 IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "IMPROPER PRIVILEGE MANAGEMENT CWE-269",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-22T17:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-08-14T00:00:00",
"ID": "CVE-2018-14787",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IntelliSpace Cardiovascular (ISCV) products",
"version": {
"version_data": [
{
"version_value": "IntelliSpace Cardiovascular, Version 3.1 or prior"
},
{
"version_value": "Xcelera Version 4.1 or prior"
}
]
}
}
]
},
"vendor_name": "Philips"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Philips\u0027 IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER PRIVILEGE MANAGEMENT CWE-269"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"refsource": "CONFIRM",
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-14787",
"datePublished": "2018-08-22T18:00:00Z",
"dateReserved": "2018-08-01T00:00:00",
"dateUpdated": "2024-09-16T18:59:28.155Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-14789 (GCVE-0-2018-14789)
Vulnerability from cvelistv5 – Published: 2018-08-22 18:00 – Updated: 2024-09-16 17:18- CWE-428 - UNQUOTED SEARCH PATH OR ELEMENT CWE-428
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Philips | IntelliSpace Cardiovascular (ISCV) products |
Affected:
IntelliSpace Cardiovascular, Version 3.1 or prior
Affected: Xcelera Version 4.1 or prior |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:38:13.980Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IntelliSpace Cardiovascular (ISCV) products",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "IntelliSpace Cardiovascular, Version 3.1 or prior"
},
{
"status": "affected",
"version": "Xcelera Version 4.1 or prior"
}
]
}
],
"datePublic": "2018-08-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "In Philips\u0027 IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "UNQUOTED SEARCH PATH OR ELEMENT CWE-428",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-22T17:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-08-14T00:00:00",
"ID": "CVE-2018-14789",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IntelliSpace Cardiovascular (ISCV) products",
"version": {
"version_data": [
{
"version_value": "IntelliSpace Cardiovascular, Version 3.1 or prior"
},
{
"version_value": "Xcelera Version 4.1 or prior"
}
]
}
}
]
},
"vendor_name": "Philips"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Philips\u0027 IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "UNQUOTED SEARCH PATH OR ELEMENT CWE-428"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"refsource": "CONFIRM",
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-14789",
"datePublished": "2018-08-22T18:00:00Z",
"dateReserved": "2018-08-01T00:00:00",
"dateUpdated": "2024-09-16T17:18:12.900Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-14111 (GCVE-0-2017-14111)
Vulnerability from cvelistv5 – Published: 2017-11-17 20:00 – Updated: 2024-08-05 19:20- n/a
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T19:20:41.262Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "101850",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/101850"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-318-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-11-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-11-17T19:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "101850",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/101850"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-318-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-14111",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"refsource": "CONFIRM",
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "101850",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/101850"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-318-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-318-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-14111",
"datePublished": "2017-11-17T20:00:00",
"dateReserved": "2017-09-01T00:00:00",
"dateUpdated": "2024-08-05T19:20:41.262Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}