CVE-2024-25942 (GCVE-0-2024-25942)

Vulnerability from nvd – Published: 2024-03-19 07:52 – Updated: 2024-08-12 13:53
VLAI?
Summary
Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.
CWE
  • CWE-20 - Improper Input Validation
Assigner
References
Impacted products
Vendor Product Version
Dell PowerEdge Platform Affected: N/A , < 2.19.0  (semver)
Affected: N/A , < 2.14.0 (semver)
Affected: N/A , < 1.19.0 (semver)
Create a notification for this product.
Date Public ?
2024-03-18 06:30
Credits
Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:52:06.241Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000223210/dsa-2024-104-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-25942",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-12T13:53:19.426811Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-12T13:53:37.973Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerEdge Platform",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.19.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.19.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue."
        }
      ],
      "datePublic": "2024-03-18T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
            }
          ],
          "value": "Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "LOW",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-19T07:52:29.228Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000223210/dsa-2024-104-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-25942",
    "datePublished": "2024-03-19T07:52:29.228Z",
    "dateReserved": "2024-02-13T05:29:58.481Z",
    "dateUpdated": "2024-08-12T13:53:37.973Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-22453 (GCVE-0-2024-22453)

Vulnerability from nvd – Published: 2024-03-19 07:42 – Updated: 2024-08-01 22:43
VLAI?
Summary
Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory.
CWE
  • CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Dell PowerEdge Platform Affected: N/A , < 2.19.0 (semver)
Affected: N/A , < 2.14.0 (semver)
Affected: N/A , < 1.19.0 (semver)
Create a notification for this product.
Date Public ?
2024-03-18 06:30
Credits
Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-22453",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-19T14:44:45.916921Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:52:52.907Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:43:34.929Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000223209/dsa-2024-105-security-update-for-dell-poweredge-server-bios-for-a-heap-based-buffer-overflow-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerEdge Platform",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.19.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.19.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue"
        }
      ],
      "datePublic": "2024-03-18T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory."
            }
          ],
          "value": "Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-19T07:42:27.785Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000223209/dsa-2024-105-security-update-for-dell-poweredge-server-bios-for-a-heap-based-buffer-overflow-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-22453",
    "datePublished": "2024-03-19T07:42:27.785Z",
    "dateReserved": "2024-01-10T15:26:10.251Z",
    "dateUpdated": "2024-08-01T22:43:34.929Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-0173 (GCVE-0-2024-0173)

Vulnerability from nvd – Published: 2024-03-13 16:52 – Updated: 2024-08-01 17:41
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
CWE
  • CWE-788 - Access of Memory Location After End of Buffer
Assigner
References
Impacted products
Vendor Product Version
Dell PowerEdge Platform Affected: N/A , < 2.0.0 (semver)
Affected: N/A , < 1.7.6 (semver)
Affected: N/A , < 1.7.2 (semver)
Affected: N/A , < 1.2.3 (semver)
Affected: N/A , < 1.13.2 (semver)
Affected: N/A , < 1.14.1 (semver)
Affected: N/A , < 1.9.1 (semver)
Affected: N/A , < 2.14.1 (semver)
Affected: N/A , < 2.21.2 (semver)
Affected: N/A , < 2.21.1 (semver)
Affected: N/A , < 2.21.0 (semver)
Affected: N/A , < 2.16.0 (semver)
Affected: N/A , < 2.19.0  (semver)
Affected: N/A , < 2.14.0  (semver)
Affected: N/A , < 1.19.0  (semver)
Affected: N/A , < 2.20.0   (semver)
Create a notification for this product.
Date Public ?
2024-03-12 06:30
Credits
Dell would like to thank codebreaker1337 for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-0173",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-13T20:00:50.556667Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:58:23.919Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T17:41:16.066Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerEdge Platform\t",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.7.6",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.7.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.2.3",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.13.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.14.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.9.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.16.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.19.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.19.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.20.0\u202f\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank codebreaker1337 for reporting this issue."
        }
      ],
      "datePublic": "2024-03-12T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
            }
          ],
          "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-788",
              "description": "CWE-788: Access of Memory Location After End of Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-13T16:52:21.293Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-0173",
    "datePublished": "2024-03-13T16:52:21.293Z",
    "dateReserved": "2023-12-14T05:35:37.836Z",
    "dateUpdated": "2024-08-01T17:41:16.066Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-0154 (GCVE-0-2024-0154)

Vulnerability from nvd – Published: 2024-03-13 16:41 – Updated: 2024-08-01 17:41
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
CWE
  • CWE-788 - Access of Memory Location After End of Buffer
Assigner
References
Impacted products
Vendor Product Version
Dell PowerEdge Platform Affected: N/A , < 2.0.0 (semver)
Affected: N/A , < 1.7.6 (semver)
Affected: N/A , < 1.7.2 (semver)
Affected: N/A , < 1.2.3 (semver)
Affected: N/A , < 1.13.2 (semver)
Affected: N/A , < 1.14.1 (semver)
Affected: N/A , < 1.9.1 (semver)
Affected: N/A , < 2.14.1 (semver)
Affected: N/A , < 2.21.2 (semver)
Affected: N/A , < 2.21.1 (semver)
Affected: N/A , < 2.21.0 (semver)
Affected: N/A , < 2.16.0 (semver)
Affected: N/A , < 2.19.0  (semver)
Affected: N/A , < 2.14.0  (semver)
Affected: N/A , < 1.19.0  (semver)
Affected: N/A , < 2.20.0  (semver)
Create a notification for this product.
Date Public ?
2024-03-12 06:30
Credits
Dell would like to thank codebreaker1337 for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-0154",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-13T19:40:48.987776Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:58:45.175Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T17:41:16.006Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerEdge Platform",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.7.6",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.7.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.2.3",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.13.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.14.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.9.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.16.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.19.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.19.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.20.0\u202f",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank codebreaker1337 for reporting this issue."
        }
      ],
      "datePublic": "2024-03-12T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
            }
          ],
          "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-788",
              "description": "CWE-788: Access of Memory Location After End of Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-13T16:41:09.360Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-0154",
    "datePublished": "2024-03-13T16:41:09.360Z",
    "dateReserved": "2023-12-14T05:29:25.760Z",
    "dateUpdated": "2024-08-01T17:41:16.006Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-0161 (GCVE-0-2024-0161)

Vulnerability from nvd – Published: 2024-03-13 16:04 – Updated: 2024-08-12 13:56
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.
CWE
  • CWE-20 - Improper Input Validation
Assigner
References
Impacted products
Vendor Product Version
Dell PowerEdge Platform Affected: N/A , < 1.1.1 (semver)
Affected: N/A , < 1.13.2 (semver)
Affected: N/A , < 1.14.1 (semver)
Affected: N/A , < 1.9.1 (semver)
Affected: N/A , < 2.21.2 (semver)
Affected: N/A , < 2.21.1 (semver)
Affected: N/A , < 2.21.0 (semver)
Affected: N/A , < 2.19.0 (semver)
Affected: N/A , < 2.14.0 (semver)
Affected: N/A , < 1.19.0  (semver)
Affected: N/A , < 2.20.0 (semver)
Create a notification for this product.
Date Public ?
2024-03-12 06:30
Credits
Dell would like to thank codebreaker1337 as well as schur of BUPT, Dubhe Lab for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T17:41:15.986Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000222979/dsa-2024-006-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-0161",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-12T13:56:13.395413Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-12T13:56:29.418Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerEdge Platform",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "1.1.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.13.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.14.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.9.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.19.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.19.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.20.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank codebreaker1337 as well as schur of BUPT, Dubhe Lab for reporting this issue."
        }
      ],
      "datePublic": "2024-03-12T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
            }
          ],
          "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-13T16:04:12.678Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000222979/dsa-2024-006-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-0161",
    "datePublished": "2024-03-13T16:04:12.678Z",
    "dateReserved": "2023-12-14T05:30:39.766Z",
    "dateUpdated": "2024-08-12T13:56:29.418Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-25942 (GCVE-0-2024-25942)

Vulnerability from cvelistv5 – Published: 2024-03-19 07:52 – Updated: 2024-08-12 13:53
VLAI?
Summary
Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.
CWE
  • CWE-20 - Improper Input Validation
Assigner
References
Impacted products
Vendor Product Version
Dell PowerEdge Platform Affected: N/A , < 2.19.0  (semver)
Affected: N/A , < 2.14.0 (semver)
Affected: N/A , < 1.19.0 (semver)
Create a notification for this product.
Date Public ?
2024-03-18 06:30
Credits
Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:52:06.241Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000223210/dsa-2024-104-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-25942",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-12T13:53:19.426811Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-12T13:53:37.973Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerEdge Platform",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.19.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.19.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue."
        }
      ],
      "datePublic": "2024-03-18T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
            }
          ],
          "value": "Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "LOW",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-19T07:52:29.228Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000223210/dsa-2024-104-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-25942",
    "datePublished": "2024-03-19T07:52:29.228Z",
    "dateReserved": "2024-02-13T05:29:58.481Z",
    "dateUpdated": "2024-08-12T13:53:37.973Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-22453 (GCVE-0-2024-22453)

Vulnerability from cvelistv5 – Published: 2024-03-19 07:42 – Updated: 2024-08-01 22:43
VLAI?
Summary
Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory.
CWE
  • CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Dell PowerEdge Platform Affected: N/A , < 2.19.0 (semver)
Affected: N/A , < 2.14.0 (semver)
Affected: N/A , < 1.19.0 (semver)
Create a notification for this product.
Date Public ?
2024-03-18 06:30
Credits
Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-22453",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-19T14:44:45.916921Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:52:52.907Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:43:34.929Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000223209/dsa-2024-105-security-update-for-dell-poweredge-server-bios-for-a-heap-based-buffer-overflow-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerEdge Platform",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.19.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.19.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue"
        }
      ],
      "datePublic": "2024-03-18T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory."
            }
          ],
          "value": "Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-19T07:42:27.785Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000223209/dsa-2024-105-security-update-for-dell-poweredge-server-bios-for-a-heap-based-buffer-overflow-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-22453",
    "datePublished": "2024-03-19T07:42:27.785Z",
    "dateReserved": "2024-01-10T15:26:10.251Z",
    "dateUpdated": "2024-08-01T22:43:34.929Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-0173 (GCVE-0-2024-0173)

Vulnerability from cvelistv5 – Published: 2024-03-13 16:52 – Updated: 2024-08-01 17:41
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
CWE
  • CWE-788 - Access of Memory Location After End of Buffer
Assigner
References
Impacted products
Vendor Product Version
Dell PowerEdge Platform Affected: N/A , < 2.0.0 (semver)
Affected: N/A , < 1.7.6 (semver)
Affected: N/A , < 1.7.2 (semver)
Affected: N/A , < 1.2.3 (semver)
Affected: N/A , < 1.13.2 (semver)
Affected: N/A , < 1.14.1 (semver)
Affected: N/A , < 1.9.1 (semver)
Affected: N/A , < 2.14.1 (semver)
Affected: N/A , < 2.21.2 (semver)
Affected: N/A , < 2.21.1 (semver)
Affected: N/A , < 2.21.0 (semver)
Affected: N/A , < 2.16.0 (semver)
Affected: N/A , < 2.19.0  (semver)
Affected: N/A , < 2.14.0  (semver)
Affected: N/A , < 1.19.0  (semver)
Affected: N/A , < 2.20.0   (semver)
Create a notification for this product.
Date Public ?
2024-03-12 06:30
Credits
Dell would like to thank codebreaker1337 for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-0173",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-13T20:00:50.556667Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:58:23.919Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T17:41:16.066Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerEdge Platform\t",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.7.6",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.7.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.2.3",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.13.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.14.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.9.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.16.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.19.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.19.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.20.0\u202f\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank codebreaker1337 for reporting this issue."
        }
      ],
      "datePublic": "2024-03-12T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
            }
          ],
          "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-788",
              "description": "CWE-788: Access of Memory Location After End of Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-13T16:52:21.293Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-0173",
    "datePublished": "2024-03-13T16:52:21.293Z",
    "dateReserved": "2023-12-14T05:35:37.836Z",
    "dateUpdated": "2024-08-01T17:41:16.066Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-0154 (GCVE-0-2024-0154)

Vulnerability from cvelistv5 – Published: 2024-03-13 16:41 – Updated: 2024-08-01 17:41
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
CWE
  • CWE-788 - Access of Memory Location After End of Buffer
Assigner
References
Impacted products
Vendor Product Version
Dell PowerEdge Platform Affected: N/A , < 2.0.0 (semver)
Affected: N/A , < 1.7.6 (semver)
Affected: N/A , < 1.7.2 (semver)
Affected: N/A , < 1.2.3 (semver)
Affected: N/A , < 1.13.2 (semver)
Affected: N/A , < 1.14.1 (semver)
Affected: N/A , < 1.9.1 (semver)
Affected: N/A , < 2.14.1 (semver)
Affected: N/A , < 2.21.2 (semver)
Affected: N/A , < 2.21.1 (semver)
Affected: N/A , < 2.21.0 (semver)
Affected: N/A , < 2.16.0 (semver)
Affected: N/A , < 2.19.0  (semver)
Affected: N/A , < 2.14.0  (semver)
Affected: N/A , < 1.19.0  (semver)
Affected: N/A , < 2.20.0  (semver)
Create a notification for this product.
Date Public ?
2024-03-12 06:30
Credits
Dell would like to thank codebreaker1337 for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-0154",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-13T19:40:48.987776Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:58:45.175Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T17:41:16.006Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerEdge Platform",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.7.6",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.7.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.2.3",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.13.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.14.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.9.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.16.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.19.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.19.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.20.0\u202f",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank codebreaker1337 for reporting this issue."
        }
      ],
      "datePublic": "2024-03-12T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
            }
          ],
          "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-788",
              "description": "CWE-788: Access of Memory Location After End of Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-13T16:41:09.360Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-0154",
    "datePublished": "2024-03-13T16:41:09.360Z",
    "dateReserved": "2023-12-14T05:29:25.760Z",
    "dateUpdated": "2024-08-01T17:41:16.006Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-0161 (GCVE-0-2024-0161)

Vulnerability from cvelistv5 – Published: 2024-03-13 16:04 – Updated: 2024-08-12 13:56
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.
CWE
  • CWE-20 - Improper Input Validation
Assigner
References
Impacted products
Vendor Product Version
Dell PowerEdge Platform Affected: N/A , < 1.1.1 (semver)
Affected: N/A , < 1.13.2 (semver)
Affected: N/A , < 1.14.1 (semver)
Affected: N/A , < 1.9.1 (semver)
Affected: N/A , < 2.21.2 (semver)
Affected: N/A , < 2.21.1 (semver)
Affected: N/A , < 2.21.0 (semver)
Affected: N/A , < 2.19.0 (semver)
Affected: N/A , < 2.14.0 (semver)
Affected: N/A , < 1.19.0  (semver)
Affected: N/A , < 2.20.0 (semver)
Create a notification for this product.
Date Public ?
2024-03-12 06:30
Credits
Dell would like to thank codebreaker1337 as well as schur of BUPT, Dubhe Lab for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T17:41:15.986Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000222979/dsa-2024-006-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-0161",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-12T13:56:13.395413Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-12T13:56:29.418Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerEdge Platform",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "1.1.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.13.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.14.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.9.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.2",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.21.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.19.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.14.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.19.0\u00a0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.20.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank codebreaker1337 as well as schur of BUPT, Dubhe Lab for reporting this issue."
        }
      ],
      "datePublic": "2024-03-12T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
            }
          ],
          "value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-13T16:04:12.678Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000222979/dsa-2024-006-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-0161",
    "datePublished": "2024-03-13T16:04:12.678Z",
    "dateReserved": "2023-12-14T05:30:39.766Z",
    "dateUpdated": "2024-08-12T13:56:29.418Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}