Search criteria

10 vulnerabilities found for wn579x3_firmware by wavlink

CVE-2023-3380 (GCVE-0-2023-3380)

Vulnerability from nvd – Published: 2023-06-23 09:31 – Updated: 2024-08-02 06:55
VLAI?
Title
Wavlink WN579X3 Ping Test adm.cgi injection
Summary
A vulnerability classified as critical has been found in Wavlink WN579X3 up to 20230615. Affected is an unknown function of the file /cgi-bin/adm.cgi of the component Ping Test. The manipulation of the argument pingIp leads to injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-232236. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
Assigner
References
Impacted products
Vendor Product Version
Wavlink WN579X3 Affected: 20230615
Create a notification for this product.
Credits
WWesleywww (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:55:03.103Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.232236"
          },
          {
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.232236"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/sleepyvv/vul_report/blob/main/WAVLINK/WAVLINK-WN579X3-RCE.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Ping Test"
          ],
          "product": "WN579X3",
          "vendor": "Wavlink",
          "versions": [
            {
              "status": "affected",
              "version": "20230615"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "analyst",
          "value": "WWesleywww (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Wavlink WN579X3 up to 20230615. Affected is an unknown function of the file /cgi-bin/adm.cgi of the component Ping Test. The manipulation of the argument pingIp leads to injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-232236. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Wavlink WN579X3 bis 20230615 entdeckt. Hiervon betroffen ist ein unbekannter Codeblock der Datei /cgi-bin/adm.cgi der Komponente Ping Test. Durch Manipulation des Arguments pingIp mit unbekannten Daten kann eine injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "CWE-74 Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-23T13:39:18.352Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.232236"
        },
        {
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.232236"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/sleepyvv/vul_report/blob/main/WAVLINK/WAVLINK-WN579X3-RCE.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-06-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-06-23T00:00:00.000Z",
          "value": "CVE reserved"
        },
        {
          "lang": "en",
          "time": "2023-06-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2023-07-17T17:37:03.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Wavlink WN579X3 Ping Test adm.cgi injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-3380",
    "datePublished": "2023-06-23T09:31:03.911Z",
    "dateReserved": "2023-06-23T09:14:21.253Z",
    "dateUpdated": "2024-08-02T06:55:03.103Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-31847 (GCVE-0-2022-31847)

Vulnerability from nvd – Published: 2022-06-14 13:09 – Updated: 2024-08-03 07:26
VLAI?
Summary
A vulnerability in /cgi-bin/ExportAllSettings.sh of WAVLINK WN579 X3 M79X3.V5030.180719 allows attackers to obtain sensitive router information via a crafted POST request.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:26:01.140Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/pghuanghui/CVE_Request/blob/main/WAVLINK%20WN579%20X3__Sensitive%20information%20leakage.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in /cgi-bin/ExportAllSettings.sh of WAVLINK WN579 X3 M79X3.V5030.180719 allows attackers to obtain sensitive router information via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-14T13:09:58",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/pghuanghui/CVE_Request/blob/main/WAVLINK%20WN579%20X3__Sensitive%20information%20leakage.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-31847",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in /cgi-bin/ExportAllSettings.sh of WAVLINK WN579 X3 M79X3.V5030.180719 allows attackers to obtain sensitive router information via a crafted POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/pghuanghui/CVE_Request/blob/main/WAVLINK%20WN579%20X3__Sensitive%20information%20leakage.md",
              "refsource": "MISC",
              "url": "https://github.com/pghuanghui/CVE_Request/blob/main/WAVLINK%20WN579%20X3__Sensitive%20information%20leakage.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-31847",
    "datePublished": "2022-06-14T13:09:58",
    "dateReserved": "2022-05-31T00:00:00",
    "dateUpdated": "2024-08-03T07:26:01.140Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-13117 (GCVE-0-2020-13117)

Vulnerability from nvd – Published: 2021-02-09 18:53 – Updated: 2025-08-19 13:24
VLAI?
Summary
Wavlink WN575A4, WN579X3, and WN530G3A devices through 2020-05-15 allow unauthenticated remote users to inject commands via the key parameter in a login request.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:11:19.063Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.0xlabs.com/2021/02/wavlink-rce-CVE-2020-13117.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Wavlink WN575A4, WN579X3, and WN530G3A devices through 2020-05-15 allow unauthenticated remote users to inject commands via the key parameter in a login request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-19T13:24:22.716Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://blog.0xlabs.com/2021/02/wavlink-rce-CVE-2020-13117.html"
        },
        {
          "url": "https://github.com/ice-wzl/Wavlink-WN530G3A-Cmd-Injection/blob/main/README.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-13117",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Wavlink WN575A4 and WN579X3 devices through 2020-05-15 allow unauthenticated remote users to inject commands via the key parameter in a login request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.0xlabs.com/2021/02/wavlink-rce-CVE-2020-13117.html",
              "refsource": "MISC",
              "url": "https://blog.0xlabs.com/2021/02/wavlink-rce-CVE-2020-13117.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-13117",
    "datePublished": "2021-02-09T18:53:18.000Z",
    "dateReserved": "2020-05-16T00:00:00.000Z",
    "dateUpdated": "2025-08-19T13:24:22.716Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10974 (GCVE-0-2020-10974)

Vulnerability from nvd – Published: 2020-05-07 17:42 – Updated: 2024-08-04 11:21
VLAI?
Summary
An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, Wavlink WN572HG3, Wavlink WN575A4, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:21:14.401Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sudo-jtcsec/Nyra"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Roni-Carta/nyra"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974-affected_devices"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, Wavlink WN572HG3, Wavlink WN575A4, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-04T20:12:37",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sudo-jtcsec/Nyra"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Roni-Carta/nyra"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974-affected_devices"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-10974",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, Wavlink WN572HG3, Wavlink WN575A4, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974",
              "refsource": "MISC",
              "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974"
            },
            {
              "name": "https://github.com/sudo-jtcsec/Nyra",
              "refsource": "MISC",
              "url": "https://github.com/sudo-jtcsec/Nyra"
            },
            {
              "name": "https://github.com/Roni-Carta/nyra",
              "refsource": "MISC",
              "url": "https://github.com/Roni-Carta/nyra"
            },
            {
              "name": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974-affected_devices",
              "refsource": "MISC",
              "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974-affected_devices"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-10974",
    "datePublished": "2020-05-07T17:42:57",
    "dateReserved": "2020-03-26T00:00:00",
    "dateUpdated": "2024-08-04T11:21:14.401Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12266 (GCVE-0-2020-12266)

Vulnerability from nvd – Published: 2020-04-27 14:33 – Updated: 2024-08-04 11:48
VLAI?
Summary
An issue was discovered where there are multiple externally accessible pages that do not require any sort of authentication, and store system information for internal usage. The devices automatically query these pages to update dashboards and other statistics, but the pages can be accessed externally without any authentication. All the pages follow the naming convention live_(string).shtml. Among the information disclosed is: interface status logs, IP address of the device, MAC address of the device, model and current firmware version, location, all running processes, all interfaces and their statuses, all current DHCP leases and the associated hostnames, all other wireless networks in range of the router, memory statistics, and components of the configuration of the device such as enabled features. Affected devices: Affected devices are: Wavlink WN530HG4, Wavlink WN575A3, Wavlink WN579G3,Wavlink WN531G3, Wavlink WN533A8, Wavlink WN531A6, Wavlink WN551K1, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, WN572HG3, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:58.488Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.wavlink.com"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sudo-jtcsec/Nyra"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Roni-Carta/nyra"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266-affected_devices"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered where there are multiple externally accessible pages that do not require any sort of authentication, and store system information for internal usage. The devices automatically query these pages to update dashboards and other statistics, but the pages can be accessed externally without any authentication. All the pages follow the naming convention live_(string).shtml. Among the information disclosed is: interface status logs, IP address of the device, MAC address of the device, model and current firmware version, location, all running processes, all interfaces and their statuses, all current DHCP leases and the associated hostnames, all other wireless networks in range of the router, memory statistics, and components of the configuration of the device such as enabled features. Affected devices: Affected devices are: Wavlink WN530HG4, Wavlink WN575A3, Wavlink WN579G3,Wavlink WN531G3, Wavlink WN533A8, Wavlink WN531A6, Wavlink WN551K1, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, WN572HG3, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-08T19:20:54",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.wavlink.com"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sudo-jtcsec/Nyra"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Roni-Carta/nyra"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266-affected_devices"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-12266",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered where there are multiple externally accessible pages that do not require any sort of authentication, and store system information for internal usage. The devices automatically query these pages to update dashboards and other statistics, but the pages can be accessed externally without any authentication. All the pages follow the naming convention live_(string).shtml. Among the information disclosed is: interface status logs, IP address of the device, MAC address of the device, model and current firmware version, location, all running processes, all interfaces and their statuses, all current DHCP leases and the associated hostnames, all other wireless networks in range of the router, memory statistics, and components of the configuration of the device such as enabled features. Affected devices: Affected devices are: Wavlink WN530HG4, Wavlink WN575A3, Wavlink WN579G3,Wavlink WN531G3, Wavlink WN533A8, Wavlink WN531A6, Wavlink WN551K1, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, WN572HG3, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.wavlink.com",
              "refsource": "MISC",
              "url": "https://www.wavlink.com"
            },
            {
              "name": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266",
              "refsource": "MISC",
              "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266"
            },
            {
              "name": "https://github.com/sudo-jtcsec/Nyra",
              "refsource": "MISC",
              "url": "https://github.com/sudo-jtcsec/Nyra"
            },
            {
              "name": "https://github.com/Roni-Carta/nyra",
              "refsource": "MISC",
              "url": "https://github.com/Roni-Carta/nyra"
            },
            {
              "name": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266-affected_devices",
              "refsource": "MISC",
              "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266-affected_devices"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-12266",
    "datePublished": "2020-04-27T14:33:49",
    "dateReserved": "2020-04-26T00:00:00",
    "dateUpdated": "2024-08-04T11:48:58.488Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-3380 (GCVE-0-2023-3380)

Vulnerability from cvelistv5 – Published: 2023-06-23 09:31 – Updated: 2024-08-02 06:55
VLAI?
Title
Wavlink WN579X3 Ping Test adm.cgi injection
Summary
A vulnerability classified as critical has been found in Wavlink WN579X3 up to 20230615. Affected is an unknown function of the file /cgi-bin/adm.cgi of the component Ping Test. The manipulation of the argument pingIp leads to injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-232236. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
Assigner
References
Impacted products
Vendor Product Version
Wavlink WN579X3 Affected: 20230615
Create a notification for this product.
Credits
WWesleywww (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:55:03.103Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.232236"
          },
          {
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.232236"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/sleepyvv/vul_report/blob/main/WAVLINK/WAVLINK-WN579X3-RCE.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Ping Test"
          ],
          "product": "WN579X3",
          "vendor": "Wavlink",
          "versions": [
            {
              "status": "affected",
              "version": "20230615"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "analyst",
          "value": "WWesleywww (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Wavlink WN579X3 up to 20230615. Affected is an unknown function of the file /cgi-bin/adm.cgi of the component Ping Test. The manipulation of the argument pingIp leads to injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-232236. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Wavlink WN579X3 bis 20230615 entdeckt. Hiervon betroffen ist ein unbekannter Codeblock der Datei /cgi-bin/adm.cgi der Komponente Ping Test. Durch Manipulation des Arguments pingIp mit unbekannten Daten kann eine injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "CWE-74 Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-23T13:39:18.352Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.232236"
        },
        {
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.232236"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/sleepyvv/vul_report/blob/main/WAVLINK/WAVLINK-WN579X3-RCE.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-06-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-06-23T00:00:00.000Z",
          "value": "CVE reserved"
        },
        {
          "lang": "en",
          "time": "2023-06-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2023-07-17T17:37:03.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Wavlink WN579X3 Ping Test adm.cgi injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-3380",
    "datePublished": "2023-06-23T09:31:03.911Z",
    "dateReserved": "2023-06-23T09:14:21.253Z",
    "dateUpdated": "2024-08-02T06:55:03.103Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-31847 (GCVE-0-2022-31847)

Vulnerability from cvelistv5 – Published: 2022-06-14 13:09 – Updated: 2024-08-03 07:26
VLAI?
Summary
A vulnerability in /cgi-bin/ExportAllSettings.sh of WAVLINK WN579 X3 M79X3.V5030.180719 allows attackers to obtain sensitive router information via a crafted POST request.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:26:01.140Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/pghuanghui/CVE_Request/blob/main/WAVLINK%20WN579%20X3__Sensitive%20information%20leakage.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in /cgi-bin/ExportAllSettings.sh of WAVLINK WN579 X3 M79X3.V5030.180719 allows attackers to obtain sensitive router information via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-14T13:09:58",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/pghuanghui/CVE_Request/blob/main/WAVLINK%20WN579%20X3__Sensitive%20information%20leakage.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-31847",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in /cgi-bin/ExportAllSettings.sh of WAVLINK WN579 X3 M79X3.V5030.180719 allows attackers to obtain sensitive router information via a crafted POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/pghuanghui/CVE_Request/blob/main/WAVLINK%20WN579%20X3__Sensitive%20information%20leakage.md",
              "refsource": "MISC",
              "url": "https://github.com/pghuanghui/CVE_Request/blob/main/WAVLINK%20WN579%20X3__Sensitive%20information%20leakage.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-31847",
    "datePublished": "2022-06-14T13:09:58",
    "dateReserved": "2022-05-31T00:00:00",
    "dateUpdated": "2024-08-03T07:26:01.140Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-13117 (GCVE-0-2020-13117)

Vulnerability from cvelistv5 – Published: 2021-02-09 18:53 – Updated: 2025-08-19 13:24
VLAI?
Summary
Wavlink WN575A4, WN579X3, and WN530G3A devices through 2020-05-15 allow unauthenticated remote users to inject commands via the key parameter in a login request.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:11:19.063Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.0xlabs.com/2021/02/wavlink-rce-CVE-2020-13117.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Wavlink WN575A4, WN579X3, and WN530G3A devices through 2020-05-15 allow unauthenticated remote users to inject commands via the key parameter in a login request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-19T13:24:22.716Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://blog.0xlabs.com/2021/02/wavlink-rce-CVE-2020-13117.html"
        },
        {
          "url": "https://github.com/ice-wzl/Wavlink-WN530G3A-Cmd-Injection/blob/main/README.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-13117",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Wavlink WN575A4 and WN579X3 devices through 2020-05-15 allow unauthenticated remote users to inject commands via the key parameter in a login request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.0xlabs.com/2021/02/wavlink-rce-CVE-2020-13117.html",
              "refsource": "MISC",
              "url": "https://blog.0xlabs.com/2021/02/wavlink-rce-CVE-2020-13117.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-13117",
    "datePublished": "2021-02-09T18:53:18.000Z",
    "dateReserved": "2020-05-16T00:00:00.000Z",
    "dateUpdated": "2025-08-19T13:24:22.716Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10974 (GCVE-0-2020-10974)

Vulnerability from cvelistv5 – Published: 2020-05-07 17:42 – Updated: 2024-08-04 11:21
VLAI?
Summary
An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, Wavlink WN572HG3, Wavlink WN575A4, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:21:14.401Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sudo-jtcsec/Nyra"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Roni-Carta/nyra"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974-affected_devices"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, Wavlink WN572HG3, Wavlink WN575A4, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-04T20:12:37",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sudo-jtcsec/Nyra"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Roni-Carta/nyra"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974-affected_devices"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-10974",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, Wavlink WN572HG3, Wavlink WN575A4, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974",
              "refsource": "MISC",
              "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974"
            },
            {
              "name": "https://github.com/sudo-jtcsec/Nyra",
              "refsource": "MISC",
              "url": "https://github.com/sudo-jtcsec/Nyra"
            },
            {
              "name": "https://github.com/Roni-Carta/nyra",
              "refsource": "MISC",
              "url": "https://github.com/Roni-Carta/nyra"
            },
            {
              "name": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974-affected_devices",
              "refsource": "MISC",
              "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-10974-affected_devices"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-10974",
    "datePublished": "2020-05-07T17:42:57",
    "dateReserved": "2020-03-26T00:00:00",
    "dateUpdated": "2024-08-04T11:21:14.401Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12266 (GCVE-0-2020-12266)

Vulnerability from cvelistv5 – Published: 2020-04-27 14:33 – Updated: 2024-08-04 11:48
VLAI?
Summary
An issue was discovered where there are multiple externally accessible pages that do not require any sort of authentication, and store system information for internal usage. The devices automatically query these pages to update dashboards and other statistics, but the pages can be accessed externally without any authentication. All the pages follow the naming convention live_(string).shtml. Among the information disclosed is: interface status logs, IP address of the device, MAC address of the device, model and current firmware version, location, all running processes, all interfaces and their statuses, all current DHCP leases and the associated hostnames, all other wireless networks in range of the router, memory statistics, and components of the configuration of the device such as enabled features. Affected devices: Affected devices are: Wavlink WN530HG4, Wavlink WN575A3, Wavlink WN579G3,Wavlink WN531G3, Wavlink WN533A8, Wavlink WN531A6, Wavlink WN551K1, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, WN572HG3, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:58.488Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.wavlink.com"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sudo-jtcsec/Nyra"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Roni-Carta/nyra"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266-affected_devices"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered where there are multiple externally accessible pages that do not require any sort of authentication, and store system information for internal usage. The devices automatically query these pages to update dashboards and other statistics, but the pages can be accessed externally without any authentication. All the pages follow the naming convention live_(string).shtml. Among the information disclosed is: interface status logs, IP address of the device, MAC address of the device, model and current firmware version, location, all running processes, all interfaces and their statuses, all current DHCP leases and the associated hostnames, all other wireless networks in range of the router, memory statistics, and components of the configuration of the device such as enabled features. Affected devices: Affected devices are: Wavlink WN530HG4, Wavlink WN575A3, Wavlink WN579G3,Wavlink WN531G3, Wavlink WN533A8, Wavlink WN531A6, Wavlink WN551K1, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, WN572HG3, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-08T19:20:54",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.wavlink.com"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sudo-jtcsec/Nyra"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Roni-Carta/nyra"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266-affected_devices"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-12266",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered where there are multiple externally accessible pages that do not require any sort of authentication, and store system information for internal usage. The devices automatically query these pages to update dashboards and other statistics, but the pages can be accessed externally without any authentication. All the pages follow the naming convention live_(string).shtml. Among the information disclosed is: interface status logs, IP address of the device, MAC address of the device, model and current firmware version, location, all running processes, all interfaces and their statuses, all current DHCP leases and the associated hostnames, all other wireless networks in range of the router, memory statistics, and components of the configuration of the device such as enabled features. Affected devices: Affected devices are: Wavlink WN530HG4, Wavlink WN575A3, Wavlink WN579G3,Wavlink WN531G3, Wavlink WN533A8, Wavlink WN531A6, Wavlink WN551K1, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, WN572HG3, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.wavlink.com",
              "refsource": "MISC",
              "url": "https://www.wavlink.com"
            },
            {
              "name": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266",
              "refsource": "MISC",
              "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266"
            },
            {
              "name": "https://github.com/sudo-jtcsec/Nyra",
              "refsource": "MISC",
              "url": "https://github.com/sudo-jtcsec/Nyra"
            },
            {
              "name": "https://github.com/Roni-Carta/nyra",
              "refsource": "MISC",
              "url": "https://github.com/Roni-Carta/nyra"
            },
            {
              "name": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266-affected_devices",
              "refsource": "MISC",
              "url": "https://github.com/sudo-jtcsec/CVE/blob/master/CVE-2020-12266-affected_devices"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-12266",
    "datePublished": "2020-04-27T14:33:49",
    "dateReserved": "2020-04-26T00:00:00",
    "dateUpdated": "2024-08-04T11:48:58.488Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}