Search

Find a vulnerability

Search criteria

    7 vulnerabilities found for wgs-804hpt by planet

    VAR-202505-2378

    Vulnerability from variot - Updated: 2025-11-24 23:37

    FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the ruleNamekey parameter in the web_acl_mgmt_Rules_Apply_post function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from China's PLANET company.

    Planet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the ruleNamekey parameter in the web_acl_mgmt_Rules_Apply_post function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-2378",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "planet",
            "version": "1.305b241111"
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": "wgs-804hpt  firmware  1.305b241111"
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "wgs-804hpt",
            "scope": null,
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "fw-wgs-804hpt v1.305b241111",
            "scope": null,
            "trust": 0.6,
            "vendor": "planet",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11645"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006072"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44893"
          }
        ]
      },
      "cve": "CVE-2025-44893",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-11645",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-44893",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006072",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-44893",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006072",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-11645",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11645"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006072"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44893"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the ruleNamekey parameter in the web_acl_mgmt_Rules_Apply_post function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from China\u0027s PLANET company. \n\nPlanet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the ruleNamekey parameter in the web_acl_mgmt_Rules_Apply_post function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-44893"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006072"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11645"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-44893",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006072",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11645",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11645"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006072"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44893"
          }
        ]
      },
      "id": "VAR-202505-2378",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11645"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11645"
          }
        ]
      },
      "last_update_date": "2025-11-24T23:37:19.943000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Planet FW-WGS-804HPT web_acl_mgmt_Rules_Apply_post function buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/694726"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11645"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006072"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44893"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://lafdrew.github.io/2025/04/20/web-acl-mgmt-rules-apply-post-rulename/"
          },
          {
            "trust": 1.0,
            "url": "https://raw.githubusercontent.com/lafdrew/lafdrew.github.io/7e2c4ab83017611974e61aa1384c2563ec008f49/2025/04/18/web-aaa-loginauthlistedit-get-authname-stackoverflow/index.html"
          },
          {
            "trust": 1.0,
            "url": "https://github.com/xyqer1/planet-web_acl_mgmt_rules_apply_post-rulename-stackoverflow"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-44893"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11645"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006072"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44893"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11645"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006072"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44893"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11645"
          },
          {
            "date": "2025-05-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006072"
          },
          {
            "date": "2025-05-20T20:15:42.663000",
            "db": "NVD",
            "id": "CVE-2025-44893"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11645"
          },
          {
            "date": "2025-05-30T07:51:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006072"
          },
          {
            "date": "2025-11-24T14:15:46.053000",
            "db": "NVD",
            "id": "CVE-2025-44893"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PLANET\u00a0 of \u00a0WGS-804HPT\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006072"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-2314

    Vulnerability from variot - Updated: 2025-06-08 23:23

    FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the byruleEditName parameter in the web_acl_mgmt_Rules_Edit_postcontains function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from China's PLANET company.

    Planet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the byruleEditName parameter in the web_acl_mgmt_Rules_Edit_postcontains function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-2314",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "planet",
            "version": "1.305b241111"
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": "wgs-804hpt  firmware  1.305b241111"
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "wgs-804hpt",
            "scope": null,
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "fw-wgs-804hpt v1.305b241111",
            "scope": null,
            "trust": 0.6,
            "vendor": "planet",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11646"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006074"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44886"
          }
        ]
      },
      "cve": "CVE-2025-44886",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-11646",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-44886",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006074",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-44886",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006074",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-11646",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11646"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006074"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44886"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the byruleEditName parameter in the web_acl_mgmt_Rules_Edit_postcontains function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from China\u0027s PLANET company. \n\nPlanet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the byruleEditName parameter in the web_acl_mgmt_Rules_Edit_postcontains function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-44886"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006074"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11646"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-44886",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006074",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11646",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11646"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006074"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44886"
          }
        ]
      },
      "id": "VAR-202505-2314",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11646"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11646"
          }
        ]
      },
      "last_update_date": "2025-06-08T23:23:27.984000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Planet FW-WGS-804HPT web_acl_mgmt_Rules_Edit_postcontains function buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/694731"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11646"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006074"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44886"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://lafdrew.github.io/2025/04/20/web-acl-mgmt-rules-edit-post-ruleeditname/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-44886"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11646"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006074"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44886"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11646"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006074"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44886"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11646"
          },
          {
            "date": "2025-05-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006074"
          },
          {
            "date": "2025-05-20T20:15:42.153000",
            "db": "NVD",
            "id": "CVE-2025-44886"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11646"
          },
          {
            "date": "2025-05-30T07:51:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006074"
          },
          {
            "date": "2025-05-29T15:54:44.347000",
            "db": "NVD",
            "id": "CVE-2025-44886"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PLANET\u00a0 of \u00a0WGS-804HPT\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006074"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-2357

    Vulnerability from variot - Updated: 2025-06-08 23:20

    FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the remote_ip parameter in the web_snmpv3_remote_engineId_add_post function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from Planet, a Chinese company.

    Planet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the remote_ip parameter in the web_snmpv3_remote_engineId_add_post function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-2357",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "planet",
            "version": "1.305b241111"
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": "wgs-804hpt  firmware  1.305b241111"
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "wgs-804hpt",
            "scope": null,
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "fw-wgs-804hpt v1.305b241111",
            "scope": null,
            "trust": 0.6,
            "vendor": "planet",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11649"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006061"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44885"
          }
        ]
      },
      "cve": "CVE-2025-44885",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-11649",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-44885",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006061",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-44885",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006061",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-11649",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11649"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006061"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44885"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the remote_ip parameter in the web_snmpv3_remote_engineId_add_post function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from Planet, a Chinese company. \n\nPlanet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the remote_ip parameter in the web_snmpv3_remote_engineId_add_post function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-44885"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006061"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11649"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-44885",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006061",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11649",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11649"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006061"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44885"
          }
        ]
      },
      "id": "VAR-202505-2357",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11649"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11649"
          }
        ]
      },
      "last_update_date": "2025-06-08T23:20:18.548000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Planet FW-WGS-804HPT web_snmpv3_remote_engineId_add_post function buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/694746"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11649"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006061"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44885"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://lafdrew.github.io/2025/04/20/web-snmpv3-remote-engineid-add-post-remote-ip/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-44885"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11649"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006061"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44885"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11649"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006061"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44885"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11649"
          },
          {
            "date": "2025-05-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006061"
          },
          {
            "date": "2025-05-20T20:15:42.017000",
            "db": "NVD",
            "id": "CVE-2025-44885"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11649"
          },
          {
            "date": "2025-05-30T06:40:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006061"
          },
          {
            "date": "2025-05-29T15:54:50.920000",
            "db": "NVD",
            "id": "CVE-2025-44885"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PLANET\u00a0 of \u00a0WGS-804HPT\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006061"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-2242

    Vulnerability from variot - Updated: 2025-06-08 23:19

    FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the stp_conf_name parameter in the web_stp_globalSetting_post function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from China's PLANET company.

    Planet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the failure of the stp_conf_name parameter in the web_stp_globalSetting_post function to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-2242",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "planet",
            "version": "1.305b241111"
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": "wgs-804hpt  firmware  1.305b241111"
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "wgs-804hpt",
            "scope": null,
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "fw-wgs-804hpt v1.305b241111",
            "scope": null,
            "trust": 0.6,
            "vendor": "planet",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11650"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006073"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44888"
          }
        ]
      },
      "cve": "CVE-2025-44888",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-11650",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-44888",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006073",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-44888",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006073",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-11650",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11650"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006073"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44888"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the stp_conf_name parameter in the web_stp_globalSetting_post function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from China\u0027s PLANET company. \n\nPlanet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the failure of the stp_conf_name parameter in the web_stp_globalSetting_post function to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-44888"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006073"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11650"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-44888",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006073",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11650",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11650"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006073"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44888"
          }
        ]
      },
      "id": "VAR-202505-2242",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11650"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11650"
          }
        ]
      },
      "last_update_date": "2025-06-08T23:19:22.096000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Planet FW-WGS-804HPT web_stp_globalSetting_post function buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/694751"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11650"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006073"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44888"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://lafdrew.github.io/2025/04/20/web-stp-globalsetting-post-stp-conf-name/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-44888"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11650"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006073"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44888"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11650"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006073"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44888"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11650"
          },
          {
            "date": "2025-05-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006073"
          },
          {
            "date": "2025-05-20T20:15:42.420000",
            "db": "NVD",
            "id": "CVE-2025-44888"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11650"
          },
          {
            "date": "2025-05-30T07:51:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006073"
          },
          {
            "date": "2025-05-29T15:54:33.533000",
            "db": "NVD",
            "id": "CVE-2025-44888"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PLANET\u00a0 of \u00a0WGS-804HPT\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006073"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-2333

    Vulnerability from variot - Updated: 2025-06-08 23:17

    FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the host_ip parameter in the web_snmp_notifyv3_add_post function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from China's PLANET company.

    Planet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the host_ip parameter in the web_snmp_notifyv3_add_post function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-2333",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "planet",
            "version": "1.305b241111"
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "wgs-804hpt",
            "scope": null,
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": "wgs-804hpt  firmware  1.305b241111"
          },
          {
            "model": "fw-wgs-804hpt v1.305b241111",
            "scope": null,
            "trust": 0.6,
            "vendor": "planet",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11648"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006039"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44890"
          }
        ]
      },
      "cve": "CVE-2025-44890",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-11648",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-44890",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006039",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-44890",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006039",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-11648",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11648"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006039"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44890"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the host_ip parameter in the web_snmp_notifyv3_add_post function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from China\u0027s PLANET company. \n\nPlanet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the host_ip parameter in the web_snmp_notifyv3_add_post function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-44890"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006039"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11648"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-44890",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006039",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11648",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11648"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006039"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44890"
          }
        ]
      },
      "id": "VAR-202505-2333",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11648"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11648"
          }
        ]
      },
      "last_update_date": "2025-06-08T23:17:36.770000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Planet FW-WGS-804HPT web_snmp_notifyv3_add_post function buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/694741"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11648"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006039"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44890"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://lafdrew.github.io/2025/04/20/web-snmp-notifyv3-add-post-host-ip/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-44890"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11648"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006039"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44890"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11648"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006039"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44890"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11648"
          },
          {
            "date": "2025-05-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006039"
          },
          {
            "date": "2025-05-20T20:15:42.543000",
            "db": "NVD",
            "id": "CVE-2025-44890"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11648"
          },
          {
            "date": "2025-05-30T02:45:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006039"
          },
          {
            "date": "2025-05-29T15:54:27.860000",
            "db": "NVD",
            "id": "CVE-2025-44890"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PLANET\u00a0 of \u00a0WGS-804HPT\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006039"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-2459

    Vulnerability from variot - Updated: 2025-06-08 23:14

    FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the radIpkey parameter in the web_radiusSrv_post function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from China's PLANET company.

    Planet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the radIpkey parameter in the web_radiusSrv_post function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-2459",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "planet",
            "version": "1.305b241111"
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": "wgs-804hpt  firmware  1.305b241111"
          },
          {
            "model": "wgs-804hpt",
            "scope": null,
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "fw-wgs-804hpt v1.305b241111",
            "scope": null,
            "trust": 0.6,
            "vendor": "planet",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11647"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006144"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44887"
          }
        ]
      },
      "cve": "CVE-2025-44887",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-11647",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-44887",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006144",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-44887",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006144",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-11647",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11647"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006144"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44887"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the radIpkey parameter in the web_radiusSrv_post function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from China\u0027s PLANET company. \n\nPlanet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the radIpkey parameter in the web_radiusSrv_post function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-44887"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006144"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11647"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-44887",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006144",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11647",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11647"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006144"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44887"
          }
        ]
      },
      "id": "VAR-202505-2459",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11647"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11647"
          }
        ]
      },
      "last_update_date": "2025-06-08T23:14:52.443000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Planet FW-WGS-804HPT web_radiusSrv_post function buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/694736"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11647"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006144"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44887"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://lafdrew.github.io/2025/04/20/web-radiussrv-post-radip/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-44887"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11647"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006144"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44887"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11647"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006144"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44887"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11647"
          },
          {
            "date": "2025-06-03T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006144"
          },
          {
            "date": "2025-05-20T20:15:42.290000",
            "db": "NVD",
            "id": "CVE-2025-44887"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11647"
          },
          {
            "date": "2025-06-03T07:07:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006144"
          },
          {
            "date": "2025-05-29T15:54:37.950000",
            "db": "NVD",
            "id": "CVE-2025-44887"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PLANET\u00a0 of \u00a0WGS-804HPT\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006144"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-2360

    Vulnerability from variot - Updated: 2025-06-08 23:09

    FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the web_sys_infoContact_post function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from China's PLANET company.

    Planet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the web_sys_infoContact_post function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-2360",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "planet",
            "version": "1.305b241111"
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "wgs-804hpt",
            "scope": null,
            "trust": 0.8,
            "vendor": "planet",
            "version": null
          },
          {
            "model": "wgs-804hpt",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "planet",
            "version": "wgs-804hpt  firmware  1.305b241111"
          },
          {
            "model": "fw-wgs-804hpt v1.305b241111",
            "scope": null,
            "trust": 0.6,
            "vendor": "planet",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11651"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006027"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44884"
          }
        ]
      },
      "cve": "CVE-2025-44884",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-11651",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-44884",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006027",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-44884",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006027",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-11651",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11651"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006027"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44884"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the web_sys_infoContact_post function. PLANET of WGS-804HPT A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Planet FW-WGS-804HPT is a wall-mounted managed switch from China\u0027s PLANET company. \n\nPlanet FW-WGS-804HPT has a buffer overflow vulnerability. The vulnerability is caused by the web_sys_infoContact_post function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-44884"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006027"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11651"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-44884",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006027",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-11651",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11651"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006027"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44884"
          }
        ]
      },
      "id": "VAR-202505-2360",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11651"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11651"
          }
        ]
      },
      "last_update_date": "2025-06-08T23:09:44.734000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Planet FW-WGS-804HPT web_sys_infoContact_post function buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/694756"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11651"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006027"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44884"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://lafdrew.github.io/2025/04/20/web-sys-infocontact-post-contact/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-44884"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11651"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006027"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44884"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-11651"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006027"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44884"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11651"
          },
          {
            "date": "2025-05-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006027"
          },
          {
            "date": "2025-05-20T20:15:41.897000",
            "db": "NVD",
            "id": "CVE-2025-44884"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-11651"
          },
          {
            "date": "2025-05-30T02:22:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006027"
          },
          {
            "date": "2025-05-29T15:54:57.493000",
            "db": "NVD",
            "id": "CVE-2025-44884"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "PLANET\u00a0 of \u00a0WGS-804HPT\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006027"
          }
        ],
        "trust": 0.8
      }
    }