Search criteria
60 vulnerabilities found for w30e by tenda
VAR-202509-1017
Vulnerability from variot - Updated: 2025-09-28 03:04Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the countryCode parameter in the werlessAdvancedSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHOs, small businesses, and small shops. This vulnerability stems from the inability of the countryCode parameter in the werlessAdvancedSet function to properly validate the length of input data
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202509-1017",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "lte",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.19\\(5037\\)"
},
{
"model": "w30e",
"scope": "lte",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 16.01.0.19(5037) and earlier"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.01.0.19(5037)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21390"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014503"
},
{
"db": "NVD",
"id": "CVE-2025-57087"
}
]
},
"cve": "CVE-2025-57087",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-21390",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2025-57087",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2025-014503",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-57087",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2025-014503",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-21390",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21390"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014503"
},
{
"db": "NVD",
"id": "CVE-2025-57087"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the countryCode parameter in the werlessAdvancedSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHOs, small businesses, and small shops. This vulnerability stems from the inability of the countryCode parameter in the werlessAdvancedSet function to properly validate the length of input data",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-57087"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014503"
},
{
"db": "CNVD",
"id": "CNVD-2025-21390"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-57087",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014503",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-21390",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21390"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014503"
},
{
"db": "NVD",
"id": "CVE-2025-57087"
}
]
},
"id": "VAR-202509-1017",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21390"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21390"
}
]
},
"last_update_date": "2025-09-28T03:04:55.987000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014503"
},
{
"db": "NVD",
"id": "CVE-2025-57087"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/vulndetailrecord/vulfordevice/blob/main/tenda/w30e/werlessadvancedset.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-57087"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21390"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014503"
},
{
"db": "NVD",
"id": "CVE-2025-57087"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-21390"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014503"
},
{
"db": "NVD",
"id": "CVE-2025-57087"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-21390"
},
{
"date": "2025-09-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-014503"
},
{
"date": "2025-09-09T17:16:10.180000",
"db": "NVD",
"id": "CVE-2025-57087"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-21390"
},
{
"date": "2025-09-26T02:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-014503"
},
{
"date": "2025-09-18T18:42:39.153000",
"db": "NVD",
"id": "CVE-2025-57087"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014503"
}
],
"trust": 0.8
}
}
VAR-202509-0714
Vulnerability from variot - Updated: 2025-09-26 23:37Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the String parameter in the formDeleteMeshNode function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHOs, small businesses, and small shops
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202509-0714",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "lte",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.19\\(5037\\)"
},
{
"model": "w30e",
"scope": "lte",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 16.01.0.19(5037) and earlier"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.01.0.19(5037)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21388"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014245"
},
{
"db": "NVD",
"id": "CVE-2025-57086"
}
]
},
"cve": "CVE-2025-57086",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-21388",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2025-57086",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2025-014245",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-57086",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2025-014245",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-21388",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21388"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014245"
},
{
"db": "NVD",
"id": "CVE-2025-57086"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the String parameter in the formDeleteMeshNode function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHOs, small businesses, and small shops",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-57086"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014245"
},
{
"db": "CNVD",
"id": "CNVD-2025-21388"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-57086",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014245",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-21388",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21388"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014245"
},
{
"db": "NVD",
"id": "CVE-2025-57086"
}
]
},
"id": "VAR-202509-0714",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21388"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21388"
}
]
},
"last_update_date": "2025-09-26T23:37:01.243000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014245"
},
{
"db": "NVD",
"id": "CVE-2025-57086"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/vulndetailrecord/vulfordevice/blob/main/tenda/w30e/formdeletemeshnode.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-57086"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21388"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014245"
},
{
"db": "NVD",
"id": "CVE-2025-57086"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-21388"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014245"
},
{
"db": "NVD",
"id": "CVE-2025-57086"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-21388"
},
{
"date": "2025-09-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-014245"
},
{
"date": "2025-09-09T18:15:36.020000",
"db": "NVD",
"id": "CVE-2025-57086"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-21388"
},
{
"date": "2025-09-24T02:26:00",
"db": "JVNDB",
"id": "JVNDB-2025-014245"
},
{
"date": "2025-09-17T19:49:56.150000",
"db": "NVD",
"id": "CVE-2025-57086"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014245"
}
],
"trust": 0.8
}
}
VAR-202509-1340
Vulnerability from variot - Updated: 2025-09-20 23:26Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the v17 parameter in the UploadCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHOs, small businesses, and small shops
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202509-1340",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "lte",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.19\\(5037\\)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "lte",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 16.01.0.19(5037) and earlier"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.01.0.19(5037)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21389"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014090"
},
{
"db": "NVD",
"id": "CVE-2025-57085"
}
]
},
"cve": "CVE-2025-57085",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-21389",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-57085",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-014090",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-57085",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "OTHER",
"id": "JVNDB-2025-014090",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-21389",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21389"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014090"
},
{
"db": "NVD",
"id": "CVE-2025-57085"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the v17 parameter in the UploadCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHOs, small businesses, and small shops",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-57085"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014090"
},
{
"db": "CNVD",
"id": "CNVD-2025-21389"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-57085",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014090",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-21389",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21389"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014090"
},
{
"db": "NVD",
"id": "CVE-2025-57085"
}
]
},
"id": "VAR-202509-1340",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21389"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21389"
}
]
},
"last_update_date": "2025-09-20T23:26:23.497000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014090"
},
{
"db": "NVD",
"id": "CVE-2025-57085"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/vulndetailrecord/vulfordevice/blob/main/tenda/w30e/uploadcfg.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-57085"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21389"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014090"
},
{
"db": "NVD",
"id": "CVE-2025-57085"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-21389"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014090"
},
{
"db": "NVD",
"id": "CVE-2025-57085"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-21389"
},
{
"date": "2025-09-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-014090"
},
{
"date": "2025-09-09T18:15:35.867000",
"db": "NVD",
"id": "CVE-2025-57085"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-21389"
},
{
"date": "2025-09-19T03:49:00",
"db": "JVNDB",
"id": "JVNDB-2025-014090"
},
{
"date": "2025-09-17T19:50:45.847000",
"db": "NVD",
"id": "CVE-2025-57085"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014090"
}
],
"trust": 0.8
}
}
VAR-202404-2260
Vulnerability from variot - Updated: 2025-08-15 05:48Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromwebExcptypemanFilter function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-2260",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18170"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020555"
},
{
"db": "NVD",
"id": "CVE-2024-32288"
}
]
},
"cve": "CVE-2024-32288",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-18170",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"id": "CVE-2024-32288",
"impactScore": 3.4,
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "Low",
"baseScore": 6.3,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "JVNDB-2024-020555",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-32288",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020555",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2025-18170",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18170"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020555"
},
{
"db": "NVD",
"id": "CVE-2024-32288"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromwebExcptypemanFilter function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-32288"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020555"
},
{
"db": "CNVD",
"id": "CNVD-2025-18170"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-32288",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020555",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-18170",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18170"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020555"
},
{
"db": "NVD",
"id": "CVE-2024-32288"
}
]
},
"id": "VAR-202404-2260",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18170"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18170"
}
]
},
"last_update_date": "2025-08-15T05:48:51.139000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda W30E fromwebExcptypemanFilter method buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/718026"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18170"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020555"
},
{
"db": "NVD",
"id": "CVE-2024-32288"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromwebexcptypemanfilter.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-32288"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18170"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020555"
},
{
"db": "NVD",
"id": "CVE-2024-32288"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-18170"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020555"
},
{
"db": "NVD",
"id": "CVE-2024-32288"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18170"
},
{
"date": "2025-03-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020555"
},
{
"date": "2024-04-17T14:15:08.903000",
"db": "NVD",
"id": "CVE-2024-32288"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18170"
},
{
"date": "2025-03-18T07:37:00",
"db": "JVNDB",
"id": "JVNDB-2024-020555"
},
{
"date": "2025-03-17T16:00:01.127000",
"db": "NVD",
"id": "CVE-2024-32288"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020555"
}
],
"trust": 0.8
}
}
VAR-202404-2403
Vulnerability from variot - Updated: 2025-08-15 05:47Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromVirtualSer function. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds read vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-2403",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18169"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020572"
},
{
"db": "NVD",
"id": "CVE-2024-32286"
}
]
},
"cve": "CVE-2024-32286",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-18169",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2024-32286",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020572",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-32286",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020572",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-18169",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18169"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020572"
},
{
"db": "NVD",
"id": "CVE-2024-32286"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromVirtualSer function. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds read vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-32286"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020572"
},
{
"db": "CNVD",
"id": "CNVD-2025-18169"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-32286",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020572",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-18169",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18169"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020572"
},
{
"db": "NVD",
"id": "CVE-2024-32286"
}
]
},
"id": "VAR-202404-2403",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18169"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18169"
}
]
},
"last_update_date": "2025-08-15T05:47:31.103000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda W30E fromVirtualSer method buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/718021"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18169"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-125",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds read (CWE-125) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020572"
},
{
"db": "NVD",
"id": "CVE-2024-32286"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromvirtualser.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-32286"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18169"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020572"
},
{
"db": "NVD",
"id": "CVE-2024-32286"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-18169"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020572"
},
{
"db": "NVD",
"id": "CVE-2024-32286"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18169"
},
{
"date": "2025-03-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020572"
},
{
"date": "2024-04-17T14:15:08.793000",
"db": "NVD",
"id": "CVE-2024-32286"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18169"
},
{
"date": "2025-03-19T01:23:00",
"db": "JVNDB",
"id": "JVNDB-2024-020572"
},
{
"date": "2025-03-17T15:59:43.380000",
"db": "NVD",
"id": "CVE-2024-32286"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds read vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020572"
}
],
"trust": 0.8
}
}
VAR-202404-0834
Vulnerability from variot - Updated: 2025-08-15 05:46Tenda W30E v1.0 v1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. Detailed vulnerability details are currently unavailable
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-0834",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18165"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020554"
},
{
"db": "NVD",
"id": "CVE-2024-32290"
}
]
},
"cve": "CVE-2024-32290",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "MULTIPLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 8.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.4,
"id": "CNVD-2025-18165",
"impactScore": 9.5,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "LOW",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2024-32290",
"impactScore": 5.5,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "Low",
"baseScore": 6.7,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020554",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-32290",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020554",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2025-18165",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18165"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020554"
},
{
"db": "NVD",
"id": "CVE-2024-32290"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E v1.0 v1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. Detailed vulnerability details are currently unavailable",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-32290"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020554"
},
{
"db": "CNVD",
"id": "CNVD-2025-18165"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-32290",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020554",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-18165",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18165"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020554"
},
{
"db": "NVD",
"id": "CVE-2024-32290"
}
]
},
"id": "VAR-202404-0834",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18165"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18165"
}
]
},
"last_update_date": "2025-08-15T05:46:53.093000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda W30E fromAddressNat method buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/717951"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18165"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020554"
},
{
"db": "NVD",
"id": "CVE-2024-32290"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromaddressnat_page.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-32290"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18165"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020554"
},
{
"db": "NVD",
"id": "CVE-2024-32290"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-18165"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020554"
},
{
"db": "NVD",
"id": "CVE-2024-32290"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-11T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18165"
},
{
"date": "2025-03-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020554"
},
{
"date": "2024-04-17T14:15:08.960000",
"db": "NVD",
"id": "CVE-2024-32290"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18165"
},
{
"date": "2025-03-18T07:37:00",
"db": "JVNDB",
"id": "JVNDB-2024-020554"
},
{
"date": "2025-03-17T16:00:09.727000",
"db": "NVD",
"id": "CVE-2024-32290"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020554"
}
],
"trust": 0.8
}
}
VAR-202404-1932
Vulnerability from variot - Updated: 2025-08-15 05:46Tenda W30E v1.0 V1.0.1.25(633) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter. Shenzhen Tenda Technology Co.,Ltd. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology.
The Tenda W30E suffers from a command injection vulnerability caused by the cmdinput parameter of the formexeCommand method failing to properly filter special characters and commands when constructing commands. An attacker could exploit this vulnerability to execute arbitrary commands
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-1932",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18171"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020573"
},
{
"db": "NVD",
"id": "CVE-2024-32292"
}
]
},
"cve": "CVE-2024-32292",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"id": "CNVD-2025-18171",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-32292",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020573",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-32292",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020573",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-18171",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18171"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020573"
},
{
"db": "NVD",
"id": "CVE-2024-32292"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E v1.0 V1.0.1.25(633) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter. Shenzhen Tenda Technology Co.,Ltd. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. \n\nThe Tenda W30E suffers from a command injection vulnerability caused by the cmdinput parameter of the formexeCommand method failing to properly filter special characters and commands when constructing commands. An attacker could exploit this vulnerability to execute arbitrary commands",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-32292"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020573"
},
{
"db": "CNVD",
"id": "CNVD-2025-18171"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-32292",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020573",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-18171",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18171"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020573"
},
{
"db": "NVD",
"id": "CVE-2024-32292"
}
]
},
"id": "VAR-202404-1932",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18171"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18171"
}
]
},
"last_update_date": "2025-08-15T05:46:05.567000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda W30E Command Injection Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/718031"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18171"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-77",
"trust": 1.0
},
{
"problemtype": "Command injection (CWE-77) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020573"
},
{
"db": "NVD",
"id": "CVE-2024-32292"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/formexecommand_cmdi.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-32292"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18171"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020573"
},
{
"db": "NVD",
"id": "CVE-2024-32292"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-18171"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020573"
},
{
"db": "NVD",
"id": "CVE-2024-32292"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18171"
},
{
"date": "2025-03-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020573"
},
{
"date": "2024-04-17T14:15:09.063000",
"db": "NVD",
"id": "CVE-2024-32292"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18171"
},
{
"date": "2025-03-19T01:23:00",
"db": "JVNDB",
"id": "JVNDB-2024-020573"
},
{
"date": "2025-03-17T16:00:28.613000",
"db": "NVD",
"id": "CVE-2024-32292"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Command injection vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020573"
}
],
"trust": 0.8
}
}
VAR-202404-1204
Vulnerability from variot - Updated: 2025-08-15 05:37Tenda W30E v1.0 firmware v1.0.1.25(633) has a stack overflow vulnerability via the page parameter in the fromNatlimit function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-1204",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18167"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020813"
},
{
"db": "NVD",
"id": "CVE-2024-32291"
}
]
},
"cve": "CVE-2024-32291",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-18167",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2024-32291",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2024-020813",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-32291",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020813",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-18167",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18167"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020813"
},
{
"db": "NVD",
"id": "CVE-2024-32291"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E v1.0 firmware v1.0.1.25(633) has a stack overflow vulnerability via the page parameter in the fromNatlimit function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-32291"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020813"
},
{
"db": "CNVD",
"id": "CNVD-2025-18167"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-32291",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020813",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-18167",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18167"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020813"
},
{
"db": "NVD",
"id": "CVE-2024-32291"
}
]
},
"id": "VAR-202404-1204",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18167"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18167"
}
]
},
"last_update_date": "2025-08-15T05:37:47.441000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda W30E fromNatlimit method buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/718061"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18167"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020813"
},
{
"db": "NVD",
"id": "CVE-2024-32291"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromnatlimit.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-32291"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18167"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020813"
},
{
"db": "NVD",
"id": "CVE-2024-32291"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-18167"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020813"
},
{
"db": "NVD",
"id": "CVE-2024-32291"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-11T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18167"
},
{
"date": "2025-03-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020813"
},
{
"date": "2024-04-17T14:15:09.010000",
"db": "NVD",
"id": "CVE-2024-32291"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18167"
},
{
"date": "2025-03-24T09:15:00",
"db": "JVNDB",
"id": "JVNDB-2024-020813"
},
{
"date": "2025-03-17T16:00:18.163000",
"db": "NVD",
"id": "CVE-2024-32291"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020813"
}
],
"trust": 0.8
}
}
VAR-202404-1759
Vulnerability from variot - Updated: 2025-08-15 05:32Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the qos parameter in the fromqossetting function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-1759",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18168"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020556"
},
{
"db": "NVD",
"id": "CVE-2024-32287"
}
]
},
"cve": "CVE-2024-32287",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "CNVD-2025-18168",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2024-32287",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2024-020556",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-32287",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020556",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2025-18168",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18168"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020556"
},
{
"db": "NVD",
"id": "CVE-2024-32287"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the qos parameter in the fromqossetting function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-32287"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020556"
},
{
"db": "CNVD",
"id": "CNVD-2025-18168"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-32287",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020556",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-18168",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18168"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020556"
},
{
"db": "NVD",
"id": "CVE-2024-32287"
}
]
},
"id": "VAR-202404-1759",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18168"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18168"
}
]
},
"last_update_date": "2025-08-15T05:32:38.039000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda W30E fromqossetting method buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/717956"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18168"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020556"
},
{
"db": "NVD",
"id": "CVE-2024-32287"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromqossetting.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-32287"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18168"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020556"
},
{
"db": "NVD",
"id": "CVE-2024-32287"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-18168"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020556"
},
{
"db": "NVD",
"id": "CVE-2024-32287"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-11T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18168"
},
{
"date": "2025-03-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020556"
},
{
"date": "2024-04-17T14:15:08.843000",
"db": "NVD",
"id": "CVE-2024-32287"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18168"
},
{
"date": "2025-03-18T07:37:00",
"db": "JVNDB",
"id": "JVNDB-2024-020556"
},
{
"date": "2025-03-17T15:59:52.717000",
"db": "NVD",
"id": "CVE-2024-32287"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020556"
}
],
"trust": 0.8
}
}
VAR-202404-1586
Vulnerability from variot - Updated: 2025-08-15 05:29Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-1586",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18166"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020553"
},
{
"db": "NVD",
"id": "CVE-2024-32293"
}
]
},
"cve": "CVE-2024-32293",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.7,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 5.1,
"id": "CNVD-2025-18166",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.1,
"id": "CVE-2024-32293",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.0,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020553",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-32293",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020553",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-18166",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18166"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020553"
},
{
"db": "NVD",
"id": "CVE-2024-32293"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-32293"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020553"
},
{
"db": "CNVD",
"id": "CNVD-2025-18166"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-32293",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020553",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-18166",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18166"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020553"
},
{
"db": "NVD",
"id": "CVE-2024-32293"
}
]
},
"id": "VAR-202404-1586",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18166"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18166"
}
]
},
"last_update_date": "2025-08-15T05:29:44.467000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda W30E fromDhcpListClient method buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/717946"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18166"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020553"
},
{
"db": "NVD",
"id": "CVE-2024-32293"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromdhcplistclient_page.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-32293"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18166"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020553"
},
{
"db": "NVD",
"id": "CVE-2024-32293"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-18166"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020553"
},
{
"db": "NVD",
"id": "CVE-2024-32293"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-11T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18166"
},
{
"date": "2025-03-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020553"
},
{
"date": "2024-04-17T14:15:09.113000",
"db": "NVD",
"id": "CVE-2024-32293"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18166"
},
{
"date": "2025-03-18T07:37:00",
"db": "JVNDB",
"id": "JVNDB-2024-020553"
},
{
"date": "2025-03-17T16:00:37.433000",
"db": "NVD",
"id": "CVE-2024-32293"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020553"
}
],
"trust": 0.8
}
}
VAR-202404-2353
Vulnerability from variot - Updated: 2025-08-15 05:26Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the password parameter in the formaddUserName function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-2353",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0.1.25(633)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18164"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020541"
},
{
"db": "NVD",
"id": "CVE-2024-32285"
}
]
},
"cve": "CVE-2024-32285",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.7,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 5.1,
"id": "CNVD-2025-18164",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.1,
"id": "CVE-2024-32285",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.0,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020541",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-32285",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020541",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-18164",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18164"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020541"
},
{
"db": "NVD",
"id": "CVE-2024-32285"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the password parameter in the formaddUserName function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-32285"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020541"
},
{
"db": "CNVD",
"id": "CNVD-2025-18164"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-32285",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020541",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-18164",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18164"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020541"
},
{
"db": "NVD",
"id": "CVE-2024-32285"
}
]
},
"id": "VAR-202404-2353",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18164"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18164"
}
]
},
"last_update_date": "2025-08-15T05:26:24.826000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda W30E formaddUserName method buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/717936"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18164"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020541"
},
{
"db": "NVD",
"id": "CVE-2024-32285"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/formaddusername.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-32285"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18164"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020541"
},
{
"db": "NVD",
"id": "CVE-2024-32285"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-18164"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020541"
},
{
"db": "NVD",
"id": "CVE-2024-32285"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-11T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18164"
},
{
"date": "2025-03-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020541"
},
{
"date": "2024-04-17T14:15:08.740000",
"db": "NVD",
"id": "CVE-2024-32285"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18164"
},
{
"date": "2025-03-18T03:14:00",
"db": "JVNDB",
"id": "JVNDB-2024-020541"
},
{
"date": "2025-03-17T15:59:31.947000",
"db": "NVD",
"id": "CVE-2024-32285"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020541"
}
],
"trust": 0.8
}
}
VAR-202404-0306
Vulnerability from variot - Updated: 2025-07-17 23:46A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda W30E is a new Wi-Fi 6 enterprise-class wireless router designed for SOHO, small and micro-enterprise offices, small shops and other scenarios. No detailed vulnerability details are currently provided
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-0306",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "1.0.1.25"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23303"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-026140"
},
{
"db": "NVD",
"id": "CVE-2024-4171"
}
]
},
"cve": "CVE-2024-4171",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2024-4171",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2024-026140",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2024-23303",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-4171",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-026140",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2024-4171",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-026140",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2024-23303",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23303"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-026140"
},
{
"db": "NVD",
"id": "CVE-2024-4171"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda W30E is a new Wi-Fi 6 enterprise-class wireless router designed for SOHO, small and micro-enterprise offices, small shops and other scenarios. No detailed vulnerability details are currently provided",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-4171"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-026140"
},
{
"db": "CNVD",
"id": "CNVD-2024-23303"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-4171",
"trust": 3.2
},
{
"db": "VULDB",
"id": "261990",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-026140",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-23303",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23303"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-026140"
},
{
"db": "NVD",
"id": "CVE-2024-4171"
}
]
},
"id": "VAR-202404-0306",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23303"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23303"
}
]
},
"last_update_date": "2025-07-17T23:46:05.080000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-026140"
},
{
"db": "NVD",
"id": "CVE-2024-4171"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://vuldb.com/?id.261990"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.318995"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-4171"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.261990"
},
{
"trust": 1.0,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromwizardhandle.md"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23303"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-026140"
},
{
"db": "NVD",
"id": "CVE-2024-4171"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-23303"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-026140"
},
{
"db": "NVD",
"id": "CVE-2024-4171"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-23303"
},
{
"date": "2025-07-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-026140"
},
{
"date": "2024-04-25T14:15:10.180000",
"db": "NVD",
"id": "CVE-2024-4171"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-23303"
},
{
"date": "2025-07-16T04:39:00",
"db": "JVNDB",
"id": "JVNDB-2024-026140"
},
{
"date": "2025-07-15T17:48:49.463000",
"db": "NVD",
"id": "CVE-2024-4171"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-026140"
}
],
"trust": 0.8
}
}
VAR-202312-0469
Vulnerability from variot - Updated: 2025-05-28 23:05Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formAdvancedSetListSet. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the function formAdvancedSetListSet failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-0469",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.12\\(4843\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 16.01.0.12(4843)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v16.01.0.12(4843)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-98052"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018799"
},
{
"db": "NVD",
"id": "CVE-2023-49404"
}
]
},
"cve": "CVE-2023-49404",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-98052",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-49404",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-49404",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-49404",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2023-49404",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-49404",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2023-98052",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-98052"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018799"
},
{
"db": "NVD",
"id": "CVE-2023-49404"
},
{
"db": "NVD",
"id": "CVE-2023-49404"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formAdvancedSetListSet. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the function formAdvancedSetListSet failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-49404"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018799"
},
{
"db": "CNVD",
"id": "CNVD-2023-98052"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-49404",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018799",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-98052",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-98052"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018799"
},
{
"db": "NVD",
"id": "CVE-2023-49404"
}
]
},
"id": "VAR-202312-0469",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-98052"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-98052"
}
]
},
"last_update_date": "2025-05-28T23:05:11.356000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-018799"
},
{
"db": "NVD",
"id": "CVE-2023-49404"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_setadvancedsetlist/w30e_setadvancedsetlist.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-49404"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-98052"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018799"
},
{
"db": "NVD",
"id": "CVE-2023-49404"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-98052"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-018799"
},
{
"db": "NVD",
"id": "CVE-2023-49404"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-12-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-98052"
},
{
"date": "2024-01-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-018799"
},
{
"date": "2023-12-07T18:15:08.173000",
"db": "NVD",
"id": "CVE-2023-49404"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-12-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-98052"
},
{
"date": "2024-01-12T01:18:00",
"db": "JVNDB",
"id": "JVNDB-2023-018799"
},
{
"date": "2025-05-28T16:15:31.697000",
"db": "NVD",
"id": "CVE-2023-49404"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-018799"
}
],
"trust": 0.8
}
}
VAR-202411-2725
Vulnerability from variot - Updated: 2025-05-17 23:22Tenda W30E v2.0 V16.01.0.8 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root. Shenzhen Tenda Technology Co.,Ltd. of w30e A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by a hard-coded password problem
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202411-2725",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.01.0.8"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 16.01.0.8"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v16.01.0.8"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "2.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09946"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021892"
},
{
"db": "NVD",
"id": "CVE-2024-52789"
}
]
},
"cve": "CVE-2024-52789",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.7,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 5.1,
"id": "CNVD-2025-09946",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.1,
"id": "CVE-2024-52789",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.0,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-021892",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-52789",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-021892",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-09946",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09946"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021892"
},
{
"db": "NVD",
"id": "CVE-2024-52789"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E v2.0 V16.01.0.8 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root. Shenzhen Tenda Technology Co.,Ltd. of w30e A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by a hard-coded password problem",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-52789"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021892"
},
{
"db": "CNVD",
"id": "CNVD-2025-09946"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-52789",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021892",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-09946",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09946"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021892"
},
{
"db": "NVD",
"id": "CVE-2024-52789"
}
]
},
"id": "VAR-202411-2725",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09946"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09946"
}
]
},
"last_update_date": "2025-05-17T23:22:04.912000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.0
},
{
"problemtype": "Use hard-coded credentials (CWE-798) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-021892"
},
{
"db": "NVD",
"id": "CVE-2024-52789"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://colorful-meadow-5b9.notion.site/w30e_hardcode_vuln-13dc216a1c30805998f8d994f966760a"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-52789"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09946"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021892"
},
{
"db": "NVD",
"id": "CVE-2024-52789"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-09946"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-021892"
},
{
"db": "NVD",
"id": "CVE-2024-52789"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09946"
},
{
"date": "2025-04-11T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-021892"
},
{
"date": "2024-11-19T17:15:56.377000",
"db": "NVD",
"id": "CVE-2024-52789"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09946"
},
{
"date": "2025-04-11T05:23:00",
"db": "JVNDB",
"id": "JVNDB-2024-021892"
},
{
"date": "2025-04-07T19:58:25.270000",
"db": "NVD",
"id": "CVE-2024-52789"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Vulnerability related to use of hardcoded credentials in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-021892"
}
],
"trust": 0.8
}
}
VAR-202212-0884
Vulnerability from variot - Updated: 2025-04-25 01:57Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SetIpBind. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0884",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022491"
},
{
"db": "NVD",
"id": "CVE-2022-45518"
}
]
},
"cve": "CVE-2022-45518",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45518",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45518",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45518",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45518",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45518",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2683",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022491"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2683"
},
{
"db": "NVD",
"id": "CVE-2022-45518"
},
{
"db": "NVD",
"id": "CVE-2022-45518"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SetIpBind. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45518"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022491"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45518",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022491",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2683",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022491"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2683"
},
{
"db": "NVD",
"id": "CVE-2022-45518"
}
]
},
"id": "VAR-202212-0884",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.40447345
},
"last_update_date": "2025-04-25T01:57:48.006000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022491"
},
{
"db": "NVD",
"id": "CVE-2022-45518"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/setipbind/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45518"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45518/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022491"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2683"
},
{
"db": "NVD",
"id": "CVE-2022-45518"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022491"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2683"
},
{
"db": "NVD",
"id": "CVE-2022-45518"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022491"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2683"
},
{
"date": "2022-12-08T16:15:14.433000",
"db": "NVD",
"id": "CVE-2022-45518"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T08:18:00",
"db": "JVNDB",
"id": "JVNDB-2022-022491"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2683"
},
{
"date": "2025-04-23T15:15:56.993000",
"db": "NVD",
"id": "CVE-2022-45518"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2683"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022491"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2683"
}
],
"trust": 0.6
}
}
VAR-202212-0968
Vulnerability from variot - Updated: 2025-04-25 01:57Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the editNameMit parameter at /goform/editFileName. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0968",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022502"
},
{
"db": "NVD",
"id": "CVE-2022-45507"
}
]
},
"cve": "CVE-2022-45507",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45507",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45507",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45507",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45507",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45507",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2694",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022502"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2694"
},
{
"db": "NVD",
"id": "CVE-2022-45507"
},
{
"db": "NVD",
"id": "CVE-2022-45507"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the editNameMit parameter at /goform/editFileName. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45507"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022502"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45507",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022502",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2694",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022502"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2694"
},
{
"db": "NVD",
"id": "CVE-2022-45507"
}
]
},
"id": "VAR-202212-0968",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.40447345
},
"last_update_date": "2025-04-25T01:57:47.959000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022502"
},
{
"db": "NVD",
"id": "CVE-2022-45507"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/editfilename/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45507"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45507/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022502"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2694"
},
{
"db": "NVD",
"id": "CVE-2022-45507"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022502"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2694"
},
{
"db": "NVD",
"id": "CVE-2022-45507"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022502"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2694"
},
{
"date": "2022-12-08T16:15:13.953000",
"db": "NVD",
"id": "CVE-2022-45507"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T08:19:00",
"db": "JVNDB",
"id": "JVNDB-2022-022502"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2694"
},
{
"date": "2025-04-23T15:15:55.227000",
"db": "NVD",
"id": "CVE-2022-45507"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2694"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022502"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2694"
}
],
"trust": 0.6
}
}
VAR-202212-0937
Vulnerability from variot - Updated: 2025-04-25 01:52Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeClientFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0937",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022487"
},
{
"db": "NVD",
"id": "CVE-2022-45522"
}
]
},
"cve": "CVE-2022-45522",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45522",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45522",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45522",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45522",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45522",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2679",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022487"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2679"
},
{
"db": "NVD",
"id": "CVE-2022-45522"
},
{
"db": "NVD",
"id": "CVE-2022-45522"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeClientFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45522"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022487"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45522",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022487",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2679",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022487"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2679"
},
{
"db": "NVD",
"id": "CVE-2022-45522"
}
]
},
"id": "VAR-202212-0937",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.40447345
},
"last_update_date": "2025-04-25T01:52:58.958000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022487"
},
{
"db": "NVD",
"id": "CVE-2022-45522"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/safeclientfilter/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45522"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45522/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022487"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2679"
},
{
"db": "NVD",
"id": "CVE-2022-45522"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022487"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2679"
},
{
"db": "NVD",
"id": "CVE-2022-45522"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022487"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2679"
},
{
"date": "2022-12-08T16:15:14.610000",
"db": "NVD",
"id": "CVE-2022-45522"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T08:18:00",
"db": "JVNDB",
"id": "JVNDB-2022-022487"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2679"
},
{
"date": "2025-04-23T15:15:57.630000",
"db": "NVD",
"id": "CVE-2022-45522"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2679"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022487"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2679"
}
],
"trust": 0.6
}
}
VAR-202212-0849
Vulnerability from variot - Updated: 2025-04-25 01:51Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/webExcptypemanFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0849",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.1.25(633)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18921"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022495"
},
{
"db": "NVD",
"id": "CVE-2022-45514"
}
]
},
"cve": "CVE-2022-45514",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-18921",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45514",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45514",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45514",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45514",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45514",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2023-18921",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2687",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18921"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022495"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2687"
},
{
"db": "NVD",
"id": "CVE-2022-45514"
},
{
"db": "NVD",
"id": "CVE-2022-45514"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/webExcptypemanFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45514"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022495"
},
{
"db": "CNVD",
"id": "CNVD-2023-18921"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45514",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022495",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-18921",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2687",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18921"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022495"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2687"
},
{
"db": "NVD",
"id": "CVE-2022-45514"
}
]
},
"id": "VAR-202212-0849",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18921"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18921"
}
]
},
"last_update_date": "2025-04-25T01:51:40.148000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda W30E Stack Overflow Vulnerability (CNVD-2023-18921)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/415621"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18921"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022495"
},
{
"db": "NVD",
"id": "CVE-2022-45514"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/webexcptypemanfilter/readme.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45514"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45514/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18921"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022495"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2687"
},
{
"db": "NVD",
"id": "CVE-2022-45514"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-18921"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022495"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2687"
},
{
"db": "NVD",
"id": "CVE-2022-45514"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-18921"
},
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022495"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2687"
},
{
"date": "2022-12-08T16:15:14.260000",
"db": "NVD",
"id": "CVE-2022-45514"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-18921"
},
{
"date": "2023-11-17T08:18:00",
"db": "JVNDB",
"id": "JVNDB-2022-022495"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2687"
},
{
"date": "2025-04-23T15:15:56.360000",
"db": "NVD",
"id": "CVE-2022-45514"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2687"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022495"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2687"
}
],
"trust": 0.6
}
}
VAR-202212-0873
Vulnerability from variot - Updated: 2025-04-25 01:50Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/L7Im. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0873",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022486"
},
{
"db": "NVD",
"id": "CVE-2022-45523"
}
]
},
"cve": "CVE-2022-45523",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45523",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45523",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45523",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45523",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45523",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2678",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022486"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2678"
},
{
"db": "NVD",
"id": "CVE-2022-45523"
},
{
"db": "NVD",
"id": "CVE-2022-45523"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/L7Im. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45523"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022486"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45523",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022486",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2678",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022486"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2678"
},
{
"db": "NVD",
"id": "CVE-2022-45523"
}
]
},
"id": "VAR-202212-0873",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.40447345
},
"last_update_date": "2025-04-25T01:50:14.296000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022486"
},
{
"db": "NVD",
"id": "CVE-2022-45523"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/l7im/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45523"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45523/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022486"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2678"
},
{
"db": "NVD",
"id": "CVE-2022-45523"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022486"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2678"
},
{
"db": "NVD",
"id": "CVE-2022-45523"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022486"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2678"
},
{
"date": "2022-12-08T16:15:14.653000",
"db": "NVD",
"id": "CVE-2022-45523"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T08:18:00",
"db": "JVNDB",
"id": "JVNDB-2022-022486"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2678"
},
{
"date": "2025-04-23T15:15:57.780000",
"db": "NVD",
"id": "CVE-2022-45523"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2678"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022486"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2678"
}
],
"trust": 0.6
}
}
VAR-202212-0936
Vulnerability from variot - Updated: 2025-04-25 01:50Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the Go parameter at /goform/SafeMacFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0936",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022490"
},
{
"db": "NVD",
"id": "CVE-2022-45519"
}
]
},
"cve": "CVE-2022-45519",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45519",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45519",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45519",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45519",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45519",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2681",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022490"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2681"
},
{
"db": "NVD",
"id": "CVE-2022-45519"
},
{
"db": "NVD",
"id": "CVE-2022-45519"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the Go parameter at /goform/SafeMacFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45519"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022490"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45519",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022490",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2681",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022490"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2681"
},
{
"db": "NVD",
"id": "CVE-2022-45519"
}
]
},
"id": "VAR-202212-0936",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.40447345
},
"last_update_date": "2025-04-25T01:50:14.275000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022490"
},
{
"db": "NVD",
"id": "CVE-2022-45519"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/safemacfilter/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45519"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45519/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022490"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2681"
},
{
"db": "NVD",
"id": "CVE-2022-45519"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022490"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2681"
},
{
"db": "NVD",
"id": "CVE-2022-45519"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022490"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2681"
},
{
"date": "2022-12-08T16:15:14.477000",
"db": "NVD",
"id": "CVE-2022-45519"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T08:18:00",
"db": "JVNDB",
"id": "JVNDB-2022-022490"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2681"
},
{
"date": "2025-04-23T15:15:57.153000",
"db": "NVD",
"id": "CVE-2022-45519"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2681"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022490"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2681"
}
],
"trust": 0.6
}
}
VAR-202212-0885
Vulnerability from variot - Updated: 2025-04-25 01:48Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the downaction parameter at /goform/CertListInfo. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0885",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022484"
},
{
"db": "NVD",
"id": "CVE-2022-45525"
}
]
},
"cve": "CVE-2022-45525",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45525",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45525",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45525",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45525",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45525",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2677",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022484"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2677"
},
{
"db": "NVD",
"id": "CVE-2022-45525"
},
{
"db": "NVD",
"id": "CVE-2022-45525"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the downaction parameter at /goform/CertListInfo. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45525"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022484"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45525",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022484",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2677",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022484"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2677"
},
{
"db": "NVD",
"id": "CVE-2022-45525"
}
]
},
"id": "VAR-202212-0885",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.40447345
},
"last_update_date": "2025-04-25T01:48:52.019000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022484"
},
{
"db": "NVD",
"id": "CVE-2022-45525"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/certlistinfo/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45525"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45525/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022484"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2677"
},
{
"db": "NVD",
"id": "CVE-2022-45525"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022484"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2677"
},
{
"db": "NVD",
"id": "CVE-2022-45525"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022484"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2677"
},
{
"date": "2022-12-08T16:15:14.743000",
"db": "NVD",
"id": "CVE-2022-45525"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T08:18:00",
"db": "JVNDB",
"id": "JVNDB-2022-022484"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2677"
},
{
"date": "2025-04-23T15:15:58.090000",
"db": "NVD",
"id": "CVE-2022-45525"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2677"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022484"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2677"
}
],
"trust": 0.6
}
}
VAR-202212-0927
Vulnerability from variot - Updated: 2025-04-25 01:48Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeEmailFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0927",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.1.25(633)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18919"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022497"
},
{
"db": "NVD",
"id": "CVE-2022-45512"
}
]
},
"cve": "CVE-2022-45512",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-18919",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45512",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45512",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45512",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45512",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45512",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2023-18919",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2689",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18919"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022497"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2689"
},
{
"db": "NVD",
"id": "CVE-2022-45512"
},
{
"db": "NVD",
"id": "CVE-2022-45512"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeEmailFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45512"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022497"
},
{
"db": "CNVD",
"id": "CNVD-2023-18919"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45512",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022497",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-18919",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2689",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18919"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022497"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2689"
},
{
"db": "NVD",
"id": "CVE-2022-45512"
}
]
},
"id": "VAR-202212-0927",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18919"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18919"
}
]
},
"last_update_date": "2025-04-25T01:48:51.994000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda W30E Stack Overflow Vulnerability (CNVD-2023-18919)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/415611"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18919"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022497"
},
{
"db": "NVD",
"id": "CVE-2022-45512"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/safeemailfilter/readme.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45512"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45512/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18919"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022497"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2689"
},
{
"db": "NVD",
"id": "CVE-2022-45512"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-18919"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022497"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2689"
},
{
"db": "NVD",
"id": "CVE-2022-45512"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-18919"
},
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022497"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2689"
},
{
"date": "2022-12-08T16:15:14.173000",
"db": "NVD",
"id": "CVE-2022-45512"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-18919"
},
{
"date": "2023-11-17T08:19:00",
"db": "JVNDB",
"id": "JVNDB-2022-022497"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2689"
},
{
"date": "2025-04-23T15:15:56.030000",
"db": "NVD",
"id": "CVE-2022-45512"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2689"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022497"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2689"
}
],
"trust": 0.6
}
}
VAR-202212-0969
Vulnerability from variot - Updated: 2025-04-25 01:48Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the account parameter at /goform/addUserName. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0969",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.1.25(633)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18918"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022500"
},
{
"db": "NVD",
"id": "CVE-2022-45509"
}
]
},
"cve": "CVE-2022-45509",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-18918",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45509",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45509",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45509",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45509",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45509",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2023-18918",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2692",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18918"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022500"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2692"
},
{
"db": "NVD",
"id": "CVE-2022-45509"
},
{
"db": "NVD",
"id": "CVE-2022-45509"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the account parameter at /goform/addUserName. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45509"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022500"
},
{
"db": "CNVD",
"id": "CNVD-2023-18918"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45509",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022500",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-18918",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2692",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18918"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022500"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2692"
},
{
"db": "NVD",
"id": "CVE-2022-45509"
}
]
},
"id": "VAR-202212-0969",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18918"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18918"
}
]
},
"last_update_date": "2025-04-25T01:48:51.970000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda W30E Stack Overflow Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/415601"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18918"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022500"
},
{
"db": "NVD",
"id": "CVE-2022-45509"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/addusername/readme.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45509"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45509/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18918"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022500"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2692"
},
{
"db": "NVD",
"id": "CVE-2022-45509"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-18918"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022500"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2692"
},
{
"db": "NVD",
"id": "CVE-2022-45509"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-03-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-18918"
},
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022500"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2692"
},
{
"date": "2022-12-08T16:15:14.040000",
"db": "NVD",
"id": "CVE-2022-45509"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-18918"
},
{
"date": "2023-11-17T08:19:00",
"db": "JVNDB",
"id": "JVNDB-2022-022500"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2692"
},
{
"date": "2025-04-23T15:15:55.563000",
"db": "NVD",
"id": "CVE-2022-45509"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2692"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022500"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2692"
}
],
"trust": 0.6
}
}
VAR-202212-0883
Vulnerability from variot - Updated: 2025-04-25 01:46Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the entries parameter at /goform/addressNat. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0883",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0.1.25(633)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18923"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022494"
},
{
"db": "NVD",
"id": "CVE-2022-45515"
}
]
},
"cve": "CVE-2022-45515",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-18923",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45515",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45515",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45515",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45515",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45515",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2023-18923",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2686",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18923"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022494"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2686"
},
{
"db": "NVD",
"id": "CVE-2022-45515"
},
{
"db": "NVD",
"id": "CVE-2022-45515"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the entries parameter at /goform/addressNat. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45515"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022494"
},
{
"db": "CNVD",
"id": "CNVD-2023-18923"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45515",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022494",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-18923",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2686",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18923"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022494"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2686"
},
{
"db": "NVD",
"id": "CVE-2022-45515"
}
]
},
"id": "VAR-202212-0883",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18923"
}
],
"trust": 1.0044734499999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18923"
}
]
},
"last_update_date": "2025-04-25T01:46:17.159000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda W30E Stack Overflow Vulnerability (CNVD-2023-18923)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/415626"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18923"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022494"
},
{
"db": "NVD",
"id": "CVE-2022-45515"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/addressnat/readme.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45515"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45515/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-18923"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022494"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2686"
},
{
"db": "NVD",
"id": "CVE-2022-45515"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-18923"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022494"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2686"
},
{
"db": "NVD",
"id": "CVE-2022-45515"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-18923"
},
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022494"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2686"
},
{
"date": "2022-12-08T16:15:14.303000",
"db": "NVD",
"id": "CVE-2022-45515"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-18923"
},
{
"date": "2023-11-17T08:18:00",
"db": "JVNDB",
"id": "JVNDB-2022-022494"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2686"
},
{
"date": "2025-04-23T15:15:56.520000",
"db": "NVD",
"id": "CVE-2022-45515"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2686"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022494"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2686"
}
],
"trust": 0.6
}
}
VAR-202212-0928
Vulnerability from variot - Updated: 2025-04-25 01:44Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/VirtualSer. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0928",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022492"
},
{
"db": "NVD",
"id": "CVE-2022-45517"
}
]
},
"cve": "CVE-2022-45517",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45517",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45517",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45517",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45517",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45517",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2684",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022492"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2684"
},
{
"db": "NVD",
"id": "CVE-2022-45517"
},
{
"db": "NVD",
"id": "CVE-2022-45517"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/VirtualSer. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45517"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022492"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45517",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022492",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2684",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022492"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2684"
},
{
"db": "NVD",
"id": "CVE-2022-45517"
}
]
},
"id": "VAR-202212-0928",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.40447345
},
"last_update_date": "2025-04-25T01:44:27.942000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022492"
},
{
"db": "NVD",
"id": "CVE-2022-45517"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/virtualser/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45517"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45517/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022492"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2684"
},
{
"db": "NVD",
"id": "CVE-2022-45517"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022492"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2684"
},
{
"db": "NVD",
"id": "CVE-2022-45517"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022492"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2684"
},
{
"date": "2022-12-08T16:15:14.390000",
"db": "NVD",
"id": "CVE-2022-45517"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T08:18:00",
"db": "JVNDB",
"id": "JVNDB-2022-022492"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2684"
},
{
"date": "2025-04-23T15:15:56.833000",
"db": "NVD",
"id": "CVE-2022-45517"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2684"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022492"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2684"
}
],
"trust": 0.6
}
}
VAR-202212-0938
Vulnerability from variot - Updated: 2025-04-25 01:42Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the opttype parameter at /goform/IPSECsave. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0938",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022485"
},
{
"db": "NVD",
"id": "CVE-2022-45524"
}
]
},
"cve": "CVE-2022-45524",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45524",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45524",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45524",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45524",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45524",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2676",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022485"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2676"
},
{
"db": "NVD",
"id": "CVE-2022-45524"
},
{
"db": "NVD",
"id": "CVE-2022-45524"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the opttype parameter at /goform/IPSECsave. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45524"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022485"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45524",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022485",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2676",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022485"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2676"
},
{
"db": "NVD",
"id": "CVE-2022-45524"
}
]
},
"id": "VAR-202212-0938",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.40447345
},
"last_update_date": "2025-04-25T01:42:20.307000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022485"
},
{
"db": "NVD",
"id": "CVE-2022-45524"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/ipsecsave/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45524"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45524/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022485"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2676"
},
{
"db": "NVD",
"id": "CVE-2022-45524"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022485"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2676"
},
{
"db": "NVD",
"id": "CVE-2022-45524"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022485"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2676"
},
{
"date": "2022-12-08T16:15:14.697000",
"db": "NVD",
"id": "CVE-2022-45524"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T08:18:00",
"db": "JVNDB",
"id": "JVNDB-2022-022485"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2676"
},
{
"date": "2025-04-23T15:15:57.940000",
"db": "NVD",
"id": "CVE-2022-45524"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2676"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022485"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2676"
}
],
"trust": 0.6
}
}
VAR-202212-1022
Vulnerability from variot - Updated: 2025-04-25 01:42Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeUrlFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-1022",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022488"
},
{
"db": "NVD",
"id": "CVE-2022-45521"
}
]
},
"cve": "CVE-2022-45521",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45521",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45521",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45521",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45521",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45521",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2680",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022488"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2680"
},
{
"db": "NVD",
"id": "CVE-2022-45521"
},
{
"db": "NVD",
"id": "CVE-2022-45521"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeUrlFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45521"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022488"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45521",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022488",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2680",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022488"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2680"
},
{
"db": "NVD",
"id": "CVE-2022-45521"
}
]
},
"id": "VAR-202212-1022",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.40447345
},
"last_update_date": "2025-04-25T01:42:20.282000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022488"
},
{
"db": "NVD",
"id": "CVE-2022-45521"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/safeurlfilter/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45521"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45521/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022488"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2680"
},
{
"db": "NVD",
"id": "CVE-2022-45521"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022488"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2680"
},
{
"db": "NVD",
"id": "CVE-2022-45521"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022488"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2680"
},
{
"date": "2022-12-08T16:15:14.563000",
"db": "NVD",
"id": "CVE-2022-45521"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T08:18:00",
"db": "JVNDB",
"id": "JVNDB-2022-022488"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2680"
},
{
"date": "2025-04-23T15:15:57.480000",
"db": "NVD",
"id": "CVE-2022-45521"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2680"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022488"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2680"
}
],
"trust": 0.6
}
}
VAR-202212-0850
Vulnerability from variot - Updated: 2025-04-25 01:41Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/NatStaticSetting. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0850",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022493"
},
{
"db": "NVD",
"id": "CVE-2022-45516"
}
]
},
"cve": "CVE-2022-45516",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45516",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45516",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45516",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45516",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45516",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2685",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022493"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2685"
},
{
"db": "NVD",
"id": "CVE-2022-45516"
},
{
"db": "NVD",
"id": "CVE-2022-45516"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/NatStaticSetting. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45516"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022493"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45516",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022493",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2685",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022493"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2685"
},
{
"db": "NVD",
"id": "CVE-2022-45516"
}
]
},
"id": "VAR-202212-0850",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.40447345
},
"last_update_date": "2025-04-25T01:41:45.637000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022493"
},
{
"db": "NVD",
"id": "CVE-2022-45516"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/natstaticsetting/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45516"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45516/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022493"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2685"
},
{
"db": "NVD",
"id": "CVE-2022-45516"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022493"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2685"
},
{
"db": "NVD",
"id": "CVE-2022-45516"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022493"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2685"
},
{
"date": "2022-12-08T16:15:14.347000",
"db": "NVD",
"id": "CVE-2022-45516"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T08:18:00",
"db": "JVNDB",
"id": "JVNDB-2022-022493"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2685"
},
{
"date": "2025-04-23T15:15:56.677000",
"db": "NVD",
"id": "CVE-2022-45516"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2685"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022493"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2685"
}
],
"trust": 0.6
}
}
VAR-202212-0913
Vulnerability from variot - Updated: 2025-04-25 01:41Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the cmdinput parameter at /goform/exeCommand. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0913",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022504"
},
{
"db": "NVD",
"id": "CVE-2022-45505"
}
]
},
"cve": "CVE-2022-45505",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45505",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45505",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45505",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45505",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45505",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2696",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022504"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2696"
},
{
"db": "NVD",
"id": "CVE-2022-45505"
},
{
"db": "NVD",
"id": "CVE-2022-45505"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the cmdinput parameter at /goform/exeCommand. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45505"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022504"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45505",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022504",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2696",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022504"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2696"
},
{
"db": "NVD",
"id": "CVE-2022-45505"
}
]
},
"id": "VAR-202212-0913",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.40447345
},
"last_update_date": "2025-04-25T01:41:45.596000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022504"
},
{
"db": "NVD",
"id": "CVE-2022-45505"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/execommand/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45505"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45505/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022504"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2696"
},
{
"db": "NVD",
"id": "CVE-2022-45505"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022504"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2696"
},
{
"db": "NVD",
"id": "CVE-2022-45505"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022504"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2696"
},
{
"date": "2022-12-08T16:15:13.870000",
"db": "NVD",
"id": "CVE-2022-45505"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T08:19:00",
"db": "JVNDB",
"id": "JVNDB-2022-022504"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2696"
},
{
"date": "2025-04-23T15:15:54.923000",
"db": "NVD",
"id": "CVE-2022-45505"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2696"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022504"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2696"
}
],
"trust": 0.6
}
}
VAR-202212-0934
Vulnerability from variot - Updated: 2025-04-25 01:41Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the PPPOEPassword parameter at /goform/QuickIndex. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0934",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w30e",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.1.25\\(633\\)"
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w30e firmware 1.0.1.25(633)"
},
{
"model": "w30e",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w30e",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022498"
},
{
"db": "NVD",
"id": "CVE-2022-45511"
}
]
},
"cve": "CVE-2022-45511",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45511",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-45511",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45511",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45511",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-45511",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-2690",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022498"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2690"
},
{
"db": "NVD",
"id": "CVE-2022-45511"
},
{
"db": "NVD",
"id": "CVE-2022-45511"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the PPPOEPassword parameter at /goform/QuickIndex. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45511"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022498"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45511",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2022-022498",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2690",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022498"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2690"
},
{
"db": "NVD",
"id": "CVE-2022-45511"
}
]
},
"id": "VAR-202212-0934",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.40447345
},
"last_update_date": "2025-04-25T01:41:45.576000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022498"
},
{
"db": "NVD",
"id": "CVE-2022-45511"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/quickindex/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-45511"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45511/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022498"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2690"
},
{
"db": "NVD",
"id": "CVE-2022-45511"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022498"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-2690"
},
{
"db": "NVD",
"id": "CVE-2022-45511"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-022498"
},
{
"date": "2022-12-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2690"
},
{
"date": "2022-12-08T16:15:14.127000",
"db": "NVD",
"id": "CVE-2022-45511"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-17T08:19:00",
"db": "JVNDB",
"id": "JVNDB-2022-022498"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-2690"
},
{
"date": "2025-04-23T15:15:55.873000",
"db": "NVD",
"id": "CVE-2022-45511"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2690"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-022498"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-2690"
}
],
"trust": 0.6
}
}