Search

Find a vulnerability

Search criteria

    50 vulnerabilities found for w30e by tenda

    VAR-202509-1017

    Vulnerability from variot - Updated: 2025-09-28 03:04

    Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the countryCode parameter in the werlessAdvancedSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHOs, small businesses, and small shops. This vulnerability stems from the inability of the countryCode parameter in the werlessAdvancedSet function to properly validate the length of input data

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202509-1017",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.01.0.19\\(5037\\)"
          },
          {
            "model": "w30e",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  16.01.0.19(5037)  and earlier"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "16.01.0.19(5037)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21390"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014503"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57087"
          }
        ]
      },
      "cve": "CVE-2025-57087",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-21390",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-57087",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014503",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-57087",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014503",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-21390",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21390"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014503"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57087"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the countryCode parameter in the werlessAdvancedSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHOs, small businesses, and small shops. This vulnerability stems from the inability of the countryCode parameter in the werlessAdvancedSet function to properly validate the length of input data",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-57087"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014503"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-21390"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-57087",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014503",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-21390",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21390"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014503"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57087"
          }
        ]
      },
      "id": "VAR-202509-1017",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21390"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21390"
          }
        ]
      },
      "last_update_date": "2025-09-28T03:04:55.987000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014503"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57087"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/vulndetailrecord/vulfordevice/blob/main/tenda/w30e/werlessadvancedset.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-57087"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21390"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014503"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57087"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21390"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014503"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57087"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-21390"
          },
          {
            "date": "2025-09-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014503"
          },
          {
            "date": "2025-09-09T17:16:10.180000",
            "db": "NVD",
            "id": "CVE-2025-57087"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-21390"
          },
          {
            "date": "2025-09-26T02:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014503"
          },
          {
            "date": "2025-09-18T18:42:39.153000",
            "db": "NVD",
            "id": "CVE-2025-57087"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014503"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202509-0714

    Vulnerability from variot - Updated: 2025-09-26 23:37

    Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the String parameter in the formDeleteMeshNode function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHOs, small businesses, and small shops

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202509-0714",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.01.0.19\\(5037\\)"
          },
          {
            "model": "w30e",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  16.01.0.19(5037)  and earlier"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "16.01.0.19(5037)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21388"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014245"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57086"
          }
        ]
      },
      "cve": "CVE-2025-57086",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-21388",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-57086",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014245",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-57086",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014245",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-21388",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21388"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014245"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57086"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the String parameter in the formDeleteMeshNode function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHOs, small businesses, and small shops",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-57086"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014245"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-21388"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-57086",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014245",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-21388",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21388"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014245"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57086"
          }
        ]
      },
      "id": "VAR-202509-0714",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21388"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21388"
          }
        ]
      },
      "last_update_date": "2025-09-26T23:37:01.243000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014245"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57086"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/vulndetailrecord/vulfordevice/blob/main/tenda/w30e/formdeletemeshnode.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-57086"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21388"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014245"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57086"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21388"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014245"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57086"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-21388"
          },
          {
            "date": "2025-09-24T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014245"
          },
          {
            "date": "2025-09-09T18:15:36.020000",
            "db": "NVD",
            "id": "CVE-2025-57086"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-21388"
          },
          {
            "date": "2025-09-24T02:26:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014245"
          },
          {
            "date": "2025-09-17T19:49:56.150000",
            "db": "NVD",
            "id": "CVE-2025-57086"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014245"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202509-1340

    Vulnerability from variot - Updated: 2025-09-20 23:26

    Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the v17 parameter in the UploadCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHOs, small businesses, and small shops

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202509-1340",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.01.0.19\\(5037\\)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  16.01.0.19(5037)  and earlier"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "16.01.0.19(5037)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21389"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014090"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57085"
          }
        ]
      },
      "cve": "CVE-2025-57085",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-21389",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-57085",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014090",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-57085",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014090",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-21389",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21389"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014090"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57085"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the v17 parameter in the UploadCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHOs, small businesses, and small shops",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-57085"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014090"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-21389"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-57085",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014090",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-21389",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21389"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014090"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57085"
          }
        ]
      },
      "id": "VAR-202509-1340",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21389"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21389"
          }
        ]
      },
      "last_update_date": "2025-09-20T23:26:23.497000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014090"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57085"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/vulndetailrecord/vulfordevice/blob/main/tenda/w30e/uploadcfg.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-57085"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21389"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014090"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57085"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21389"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014090"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-57085"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-21389"
          },
          {
            "date": "2025-09-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014090"
          },
          {
            "date": "2025-09-09T18:15:35.867000",
            "db": "NVD",
            "id": "CVE-2025-57085"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-21389"
          },
          {
            "date": "2025-09-19T03:49:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014090"
          },
          {
            "date": "2025-09-17T19:50:45.847000",
            "db": "NVD",
            "id": "CVE-2025-57085"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014090"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-2260

    Vulnerability from variot - Updated: 2025-08-15 05:48

    Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromwebExcptypemanFilter function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-2260",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18170"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020555"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32288"
          }
        ]
      },
      "cve": "CVE-2024-32288",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-18170",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "LOW",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-32288",
                "impactScore": 3.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "Low",
                "baseScore": 6.3,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020555",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-32288",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020555",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-18170",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18170"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020555"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32288"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromwebExcptypemanFilter function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-32288"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020555"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18170"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-32288",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020555",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18170",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18170"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020555"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32288"
          }
        ]
      },
      "id": "VAR-202404-2260",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18170"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18170"
          }
        ]
      },
      "last_update_date": "2025-08-15T05:48:51.139000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda W30E fromwebExcptypemanFilter method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/718026"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18170"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020555"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32288"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromwebexcptypemanfilter.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-32288"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18170"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020555"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32288"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18170"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020555"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32288"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18170"
          },
          {
            "date": "2025-03-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020555"
          },
          {
            "date": "2024-04-17T14:15:08.903000",
            "db": "NVD",
            "id": "CVE-2024-32288"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18170"
          },
          {
            "date": "2025-03-18T07:37:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020555"
          },
          {
            "date": "2025-03-17T16:00:01.127000",
            "db": "NVD",
            "id": "CVE-2024-32288"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020555"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-2403

    Vulnerability from variot - Updated: 2025-08-15 05:47

    Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromVirtualSer function. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds read vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-2403",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18169"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020572"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32286"
          }
        ]
      },
      "cve": "CVE-2024-32286",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-18169",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-32286",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020572",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-32286",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020572",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-18169",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18169"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020572"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32286"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromVirtualSer function. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds read vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-32286"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020572"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18169"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-32286",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020572",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18169",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18169"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020572"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32286"
          }
        ]
      },
      "id": "VAR-202404-2403",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18169"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18169"
          }
        ]
      },
      "last_update_date": "2025-08-15T05:47:31.103000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda W30E fromVirtualSer method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/718021"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18169"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-125",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds read (CWE-125) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020572"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32286"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.6,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromvirtualser.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-32286"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18169"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020572"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32286"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18169"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020572"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32286"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18169"
          },
          {
            "date": "2025-03-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020572"
          },
          {
            "date": "2024-04-17T14:15:08.793000",
            "db": "NVD",
            "id": "CVE-2024-32286"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18169"
          },
          {
            "date": "2025-03-19T01:23:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020572"
          },
          {
            "date": "2025-03-17T15:59:43.380000",
            "db": "NVD",
            "id": "CVE-2024-32286"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds read vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020572"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-0834

    Vulnerability from variot - Updated: 2025-08-15 05:46

    Tenda W30E v1.0 v1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. Detailed vulnerability details are currently unavailable

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0834",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18165"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020554"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32290"
          }
        ]
      },
      "cve": "CVE-2024-32290",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "MULTIPLE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 8.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 6.4,
                "id": "CNVD-2025-18165",
                "impactScore": 9.5,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "LOW",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.2,
                "id": "CVE-2024-32290",
                "impactScore": 5.5,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "Low",
                "baseScore": 6.7,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020554",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-32290",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020554",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-18165",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18165"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020554"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32290"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E v1.0 v1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromAddressNat function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. Detailed vulnerability details are currently unavailable",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-32290"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020554"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18165"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-32290",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020554",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18165",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18165"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020554"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32290"
          }
        ]
      },
      "id": "VAR-202404-0834",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18165"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18165"
          }
        ]
      },
      "last_update_date": "2025-08-15T05:46:53.093000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda W30E fromAddressNat method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/717951"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18165"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020554"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32290"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromaddressnat_page.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-32290"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18165"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020554"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32290"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18165"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020554"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32290"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-11T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18165"
          },
          {
            "date": "2025-03-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020554"
          },
          {
            "date": "2024-04-17T14:15:08.960000",
            "db": "NVD",
            "id": "CVE-2024-32290"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18165"
          },
          {
            "date": "2025-03-18T07:37:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020554"
          },
          {
            "date": "2025-03-17T16:00:09.727000",
            "db": "NVD",
            "id": "CVE-2024-32290"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020554"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-1932

    Vulnerability from variot - Updated: 2025-08-15 05:46

    Tenda W30E v1.0 V1.0.1.25(633) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter. Shenzhen Tenda Technology Co.,Ltd. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology.

    The Tenda W30E suffers from a command injection vulnerability caused by the cmdinput parameter of the formexeCommand method failing to properly filter special characters and commands when constructing commands. An attacker could exploit this vulnerability to execute arbitrary commands

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-1932",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18171"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020573"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32292"
          }
        ]
      },
      "cve": "CVE-2024-32292",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 8.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2025-18171",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-32292",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020573",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-32292",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020573",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-18171",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18171"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020573"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32292"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E v1.0 V1.0.1.25(633) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter. Shenzhen Tenda Technology Co.,Ltd. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. \n\nThe Tenda W30E suffers from a command injection vulnerability caused by the cmdinput parameter of the formexeCommand method failing to properly filter special characters and commands when constructing commands. An attacker could exploit this vulnerability to execute arbitrary commands",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-32292"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020573"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18171"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-32292",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020573",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18171",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18171"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020573"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32292"
          }
        ]
      },
      "id": "VAR-202404-1932",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18171"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18171"
          }
        ]
      },
      "last_update_date": "2025-08-15T05:46:05.567000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda W30E Command Injection Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/718031"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18171"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020573"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32292"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.6,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/formexecommand_cmdi.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-32292"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18171"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020573"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32292"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18171"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020573"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32292"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18171"
          },
          {
            "date": "2025-03-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020573"
          },
          {
            "date": "2024-04-17T14:15:09.063000",
            "db": "NVD",
            "id": "CVE-2024-32292"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18171"
          },
          {
            "date": "2025-03-19T01:23:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020573"
          },
          {
            "date": "2025-03-17T16:00:28.613000",
            "db": "NVD",
            "id": "CVE-2024-32292"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Command injection vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020573"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-1204

    Vulnerability from variot - Updated: 2025-08-15 05:37

    Tenda W30E v1.0 firmware v1.0.1.25(633) has a stack overflow vulnerability via the page parameter in the fromNatlimit function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-1204",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18167"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020813"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32291"
          }
        ]
      },
      "cve": "CVE-2024-32291",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-18167",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-32291",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020813",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-32291",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020813",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-18167",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18167"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020813"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32291"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E v1.0 firmware v1.0.1.25(633) has a stack overflow vulnerability via the page parameter in the fromNatlimit function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-32291"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020813"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18167"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-32291",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020813",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18167",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18167"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020813"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32291"
          }
        ]
      },
      "id": "VAR-202404-1204",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18167"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18167"
          }
        ]
      },
      "last_update_date": "2025-08-15T05:37:47.441000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda W30E fromNatlimit method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/718061"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18167"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020813"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32291"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromnatlimit.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-32291"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18167"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020813"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32291"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18167"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020813"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32291"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-11T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18167"
          },
          {
            "date": "2025-03-24T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020813"
          },
          {
            "date": "2024-04-17T14:15:09.010000",
            "db": "NVD",
            "id": "CVE-2024-32291"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18167"
          },
          {
            "date": "2025-03-24T09:15:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020813"
          },
          {
            "date": "2025-03-17T16:00:18.163000",
            "db": "NVD",
            "id": "CVE-2024-32291"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020813"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-1759

    Vulnerability from variot - Updated: 2025-08-15 05:32

    Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the qos parameter in the fromqossetting function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-1759",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18168"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020556"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32287"
          }
        ]
      },
      "cve": "CVE-2024-32287",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2025-18168",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-32287",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020556",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-32287",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020556",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-18168",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18168"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020556"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32287"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the qos parameter in the fromqossetting function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-32287"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020556"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18168"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-32287",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020556",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18168",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18168"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020556"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32287"
          }
        ]
      },
      "id": "VAR-202404-1759",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18168"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18168"
          }
        ]
      },
      "last_update_date": "2025-08-15T05:32:38.039000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda W30E fromqossetting method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/717956"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18168"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020556"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32287"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromqossetting.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-32287"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18168"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020556"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32287"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18168"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020556"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32287"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-11T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18168"
          },
          {
            "date": "2025-03-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020556"
          },
          {
            "date": "2024-04-17T14:15:08.843000",
            "db": "NVD",
            "id": "CVE-2024-32287"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18168"
          },
          {
            "date": "2025-03-18T07:37:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020556"
          },
          {
            "date": "2025-03-17T15:59:52.717000",
            "db": "NVD",
            "id": "CVE-2024-32287"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020556"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-1586

    Vulnerability from variot - Updated: 2025-08-15 05:29

    Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-1586",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18166"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020553"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32293"
          }
        ]
      },
      "cve": "CVE-2024-32293",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.7,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 5.1,
                "id": "CNVD-2025-18166",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 8.0,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.1,
                "id": "CVE-2024-32293",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.0,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020553",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-32293",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020553",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-18166",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18166"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020553"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32293"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-32293"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020553"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18166"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-32293",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020553",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18166",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18166"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020553"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32293"
          }
        ]
      },
      "id": "VAR-202404-1586",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18166"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18166"
          }
        ]
      },
      "last_update_date": "2025-08-15T05:29:44.467000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda W30E fromDhcpListClient method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/717946"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18166"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020553"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32293"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromdhcplistclient_page.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-32293"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18166"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020553"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32293"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18166"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020553"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32293"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-11T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18166"
          },
          {
            "date": "2025-03-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020553"
          },
          {
            "date": "2024-04-17T14:15:09.113000",
            "db": "NVD",
            "id": "CVE-2024-32293"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18166"
          },
          {
            "date": "2025-03-18T07:37:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020553"
          },
          {
            "date": "2025-03-17T16:00:37.433000",
            "db": "NVD",
            "id": "CVE-2024-32293"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020553"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-2353

    Vulnerability from variot - Updated: 2025-08-15 05:26

    Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the password parameter in the formaddUserName function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-2353",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18164"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020541"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32285"
          }
        ]
      },
      "cve": "CVE-2024-32285",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.7,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 5.1,
                "id": "CNVD-2025-18164",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 8.0,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.1,
                "id": "CVE-2024-32285",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.0,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020541",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-32285",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020541",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-18164",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18164"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020541"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32285"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the password parameter in the formaddUserName function. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W30E is an enterprise-grade wireless router designed for SOHO, small and micro-enterprise offices, and small shops, supporting Wi-Fi 6 technology. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-32285"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020541"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18164"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-32285",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020541",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-18164",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18164"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020541"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32285"
          }
        ]
      },
      "id": "VAR-202404-2353",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18164"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18164"
          }
        ]
      },
      "last_update_date": "2025-08-15T05:26:24.826000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda W30E formaddUserName method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/717936"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18164"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020541"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32285"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/formaddusername.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-32285"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18164"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020541"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32285"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-18164"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020541"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32285"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-11T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18164"
          },
          {
            "date": "2025-03-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020541"
          },
          {
            "date": "2024-04-17T14:15:08.740000",
            "db": "NVD",
            "id": "CVE-2024-32285"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-08-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-18164"
          },
          {
            "date": "2025-03-18T03:14:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020541"
          },
          {
            "date": "2025-03-17T15:59:31.947000",
            "db": "NVD",
            "id": "CVE-2024-32285"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020541"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-0306

    Vulnerability from variot - Updated: 2025-07-17 23:46

    A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda W30E is a new Wi-Fi 6 enterprise-class wireless router designed for SOHO, small and micro-enterprise offices, small shops and other scenarios. No detailed vulnerability details are currently provided

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0306",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "1.0.1.25"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23303"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-026140"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4171"
          }
        ]
      },
      "cve": "CVE-2024-4171",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-4171",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-026140",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2024-23303",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-4171",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-026140",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-4171",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-026140",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-23303",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23303"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-026140"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4171"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of w30e A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda W30E is a new Wi-Fi 6 enterprise-class wireless router designed for SOHO, small and micro-enterprise offices, small shops and other scenarios. No detailed vulnerability details are currently provided",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-4171"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-026140"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-23303"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-4171",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "261990",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-026140",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-23303",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23303"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-026140"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4171"
          }
        ]
      },
      "id": "VAR-202404-0306",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23303"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23303"
          }
        ]
      },
      "last_update_date": "2025-07-17T23:46:05.080000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-026140"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4171"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.261990"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.318995"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4171"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.261990"
          },
          {
            "trust": 1.0,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromwizardhandle.md"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23303"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-026140"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4171"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23303"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-026140"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4171"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-05-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-23303"
          },
          {
            "date": "2025-07-16T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-026140"
          },
          {
            "date": "2024-04-25T14:15:10.180000",
            "db": "NVD",
            "id": "CVE-2024-4171"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-05-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-23303"
          },
          {
            "date": "2025-07-16T04:39:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-026140"
          },
          {
            "date": "2025-07-15T17:48:49.463000",
            "db": "NVD",
            "id": "CVE-2024-4171"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-026140"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202312-0469

    Vulnerability from variot - Updated: 2025-05-28 23:05

    Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formAdvancedSetListSet. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the function formAdvancedSetListSet failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0469",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.01.0.12\\(4843\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  16.01.0.12(4843)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v16.01.0.12(4843)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-98052"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-018799"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-49404"
          }
        ]
      },
      "cve": "CVE-2023-49404",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2023-98052",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2023-49404",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2023-49404",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2023-49404",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2023-49404",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2023-49404",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2023-98052",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-98052"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-018799"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-49404"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-49404"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formAdvancedSetListSet. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the function formAdvancedSetListSet failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-49404"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-018799"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-98052"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-49404",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-018799",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-98052",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-98052"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-018799"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-49404"
          }
        ]
      },
      "id": "VAR-202312-0469",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-98052"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-98052"
          }
        ]
      },
      "last_update_date": "2025-05-28T23:05:11.356000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-018799"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-49404"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_setadvancedsetlist/w30e_setadvancedsetlist.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-49404"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-98052"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-018799"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-49404"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-98052"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-018799"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-49404"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-12-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-98052"
          },
          {
            "date": "2024-01-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-018799"
          },
          {
            "date": "2023-12-07T18:15:08.173000",
            "db": "NVD",
            "id": "CVE-2023-49404"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-12-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-98052"
          },
          {
            "date": "2024-01-12T01:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-018799"
          },
          {
            "date": "2025-05-28T16:15:31.697000",
            "db": "NVD",
            "id": "CVE-2023-49404"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-018799"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202411-2725

    Vulnerability from variot - Updated: 2025-05-17 23:22

    Tenda W30E v2.0 V16.01.0.8 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root. Shenzhen Tenda Technology Co.,Ltd. of w30e A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by a hard-coded password problem

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202411-2725",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.01.0.8"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  16.01.0.8"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v16.01.0.8"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "2.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09946"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-021892"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-52789"
          }
        ]
      },
      "cve": "CVE-2024-52789",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.7,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 5.1,
                "id": "CNVD-2025-09946",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 8.0,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.1,
                "id": "CVE-2024-52789",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.0,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-021892",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-52789",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-021892",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09946",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09946"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-021892"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-52789"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E v2.0 V16.01.0.8 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root. Shenzhen Tenda Technology Co.,Ltd. of w30e A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by a hard-coded password problem",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-52789"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-021892"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09946"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-52789",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-021892",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09946",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09946"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-021892"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-52789"
          }
        ]
      },
      "id": "VAR-202411-2725",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09946"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09946"
          }
        ]
      },
      "last_update_date": "2025-05-17T23:22:04.912000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 1.0
          },
          {
            "problemtype": "Use hard-coded credentials (CWE-798) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-021892"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-52789"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://colorful-meadow-5b9.notion.site/w30e_hardcode_vuln-13dc216a1c30805998f8d994f966760a"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-52789"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09946"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-021892"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-52789"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09946"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-021892"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-52789"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09946"
          },
          {
            "date": "2025-04-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-021892"
          },
          {
            "date": "2024-11-19T17:15:56.377000",
            "db": "NVD",
            "id": "CVE-2024-52789"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09946"
          },
          {
            "date": "2025-04-11T05:23:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-021892"
          },
          {
            "date": "2025-04-07T19:58:25.270000",
            "db": "NVD",
            "id": "CVE-2024-52789"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Vulnerability related to use of hardcoded credentials in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-021892"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202212-0884

    Vulnerability from variot - Updated: 2025-04-25 01:57

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SetIpBind. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0884",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022491"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45518"
          }
        ]
      },
      "cve": "CVE-2022-45518",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45518",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45518",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45518",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45518",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45518",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2683",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022491"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2683"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45518"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45518"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SetIpBind. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45518"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022491"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45518",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022491",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2683",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022491"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2683"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45518"
          }
        ]
      },
      "id": "VAR-202212-0884",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40447345
      },
      "last_update_date": "2025-04-25T01:57:48.006000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022491"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45518"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/setipbind/readme.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45518"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45518/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022491"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2683"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45518"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022491"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2683"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45518"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022491"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2683"
          },
          {
            "date": "2022-12-08T16:15:14.433000",
            "db": "NVD",
            "id": "CVE-2022-45518"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T08:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022491"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2683"
          },
          {
            "date": "2025-04-23T15:15:56.993000",
            "db": "NVD",
            "id": "CVE-2022-45518"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2683"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022491"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2683"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0968

    Vulnerability from variot - Updated: 2025-04-25 01:57

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the editNameMit parameter at /goform/editFileName. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0968",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022502"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45507"
          }
        ]
      },
      "cve": "CVE-2022-45507",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45507",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45507",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45507",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45507",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45507",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2694",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022502"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2694"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45507"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45507"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the editNameMit parameter at /goform/editFileName. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45507"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022502"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45507",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022502",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2694",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022502"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2694"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45507"
          }
        ]
      },
      "id": "VAR-202212-0968",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40447345
      },
      "last_update_date": "2025-04-25T01:57:47.959000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022502"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45507"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/editfilename/readme.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45507"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45507/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022502"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2694"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45507"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022502"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2694"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45507"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022502"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2694"
          },
          {
            "date": "2022-12-08T16:15:13.953000",
            "db": "NVD",
            "id": "CVE-2022-45507"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T08:19:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022502"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2694"
          },
          {
            "date": "2025-04-23T15:15:55.227000",
            "db": "NVD",
            "id": "CVE-2022-45507"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2694"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022502"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2694"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0937

    Vulnerability from variot - Updated: 2025-04-25 01:52

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeClientFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0937",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022487"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45522"
          }
        ]
      },
      "cve": "CVE-2022-45522",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45522",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45522",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45522",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45522",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45522",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2679",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022487"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2679"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45522"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45522"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeClientFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45522"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022487"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45522",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022487",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2679",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022487"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2679"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45522"
          }
        ]
      },
      "id": "VAR-202212-0937",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40447345
      },
      "last_update_date": "2025-04-25T01:52:58.958000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022487"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45522"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/safeclientfilter/readme.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45522"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45522/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022487"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2679"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45522"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022487"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2679"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45522"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022487"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2679"
          },
          {
            "date": "2022-12-08T16:15:14.610000",
            "db": "NVD",
            "id": "CVE-2022-45522"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T08:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022487"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2679"
          },
          {
            "date": "2025-04-23T15:15:57.630000",
            "db": "NVD",
            "id": "CVE-2022-45522"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2679"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022487"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2679"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0849

    Vulnerability from variot - Updated: 2025-04-25 01:51

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/webExcptypemanFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0849",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v1.0.1.25(633)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18921"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022495"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45514"
          }
        ]
      },
      "cve": "CVE-2022-45514",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2023-18921",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45514",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45514",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45514",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45514",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45514",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2023-18921",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2687",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18921"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022495"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2687"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45514"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45514"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/webExcptypemanFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45514"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022495"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-18921"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45514",
            "trust": 3.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022495",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-18921",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2687",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18921"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022495"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2687"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45514"
          }
        ]
      },
      "id": "VAR-202212-0849",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18921"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18921"
          }
        ]
      },
      "last_update_date": "2025-04-25T01:51:40.148000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda W30E Stack Overflow Vulnerability (CNVD-2023-18921)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/415621"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18921"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022495"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45514"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/webexcptypemanfilter/readme.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45514"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45514/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18921"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022495"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2687"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45514"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18921"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022495"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2687"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45514"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-18921"
          },
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022495"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2687"
          },
          {
            "date": "2022-12-08T16:15:14.260000",
            "db": "NVD",
            "id": "CVE-2022-45514"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-18921"
          },
          {
            "date": "2023-11-17T08:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022495"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2687"
          },
          {
            "date": "2025-04-23T15:15:56.360000",
            "db": "NVD",
            "id": "CVE-2022-45514"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2687"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022495"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2687"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0873

    Vulnerability from variot - Updated: 2025-04-25 01:50

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/L7Im. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0873",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022486"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45523"
          }
        ]
      },
      "cve": "CVE-2022-45523",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45523",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45523",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45523",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45523",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45523",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2678",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022486"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2678"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45523"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45523"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/L7Im. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45523"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022486"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45523",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022486",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2678",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022486"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2678"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45523"
          }
        ]
      },
      "id": "VAR-202212-0873",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40447345
      },
      "last_update_date": "2025-04-25T01:50:14.296000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022486"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45523"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/l7im/readme.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45523"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45523/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022486"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2678"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45523"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022486"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2678"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45523"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022486"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2678"
          },
          {
            "date": "2022-12-08T16:15:14.653000",
            "db": "NVD",
            "id": "CVE-2022-45523"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T08:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022486"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2678"
          },
          {
            "date": "2025-04-23T15:15:57.780000",
            "db": "NVD",
            "id": "CVE-2022-45523"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2678"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022486"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2678"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0936

    Vulnerability from variot - Updated: 2025-04-25 01:50

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the Go parameter at /goform/SafeMacFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0936",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022490"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45519"
          }
        ]
      },
      "cve": "CVE-2022-45519",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45519",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45519",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45519",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45519",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45519",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2681",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022490"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2681"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45519"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45519"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the Go parameter at /goform/SafeMacFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45519"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022490"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45519",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022490",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2681",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022490"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2681"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45519"
          }
        ]
      },
      "id": "VAR-202212-0936",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40447345
      },
      "last_update_date": "2025-04-25T01:50:14.275000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022490"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45519"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/safemacfilter/readme.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45519"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45519/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022490"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2681"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45519"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022490"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2681"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45519"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022490"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2681"
          },
          {
            "date": "2022-12-08T16:15:14.477000",
            "db": "NVD",
            "id": "CVE-2022-45519"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T08:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022490"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2681"
          },
          {
            "date": "2025-04-23T15:15:57.153000",
            "db": "NVD",
            "id": "CVE-2022-45519"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2681"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022490"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2681"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0885

    Vulnerability from variot - Updated: 2025-04-25 01:48

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the downaction parameter at /goform/CertListInfo. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0885",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022484"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45525"
          }
        ]
      },
      "cve": "CVE-2022-45525",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45525",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45525",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45525",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45525",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45525",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2677",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022484"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2677"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45525"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45525"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the downaction parameter at /goform/CertListInfo. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45525"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022484"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45525",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022484",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2677",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022484"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2677"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45525"
          }
        ]
      },
      "id": "VAR-202212-0885",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40447345
      },
      "last_update_date": "2025-04-25T01:48:52.019000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022484"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45525"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/certlistinfo/readme.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45525"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45525/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022484"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2677"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45525"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022484"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2677"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45525"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022484"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2677"
          },
          {
            "date": "2022-12-08T16:15:14.743000",
            "db": "NVD",
            "id": "CVE-2022-45525"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T08:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022484"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2677"
          },
          {
            "date": "2025-04-23T15:15:58.090000",
            "db": "NVD",
            "id": "CVE-2022-45525"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2677"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022484"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2677"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0927

    Vulnerability from variot - Updated: 2025-04-25 01:48

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeEmailFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0927",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v1.0.1.25(633)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18919"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022497"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45512"
          }
        ]
      },
      "cve": "CVE-2022-45512",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2023-18919",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45512",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45512",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45512",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45512",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45512",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2023-18919",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2689",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18919"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022497"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2689"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45512"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45512"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeEmailFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45512"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022497"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-18919"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45512",
            "trust": 3.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022497",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-18919",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2689",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18919"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022497"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2689"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45512"
          }
        ]
      },
      "id": "VAR-202212-0927",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18919"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18919"
          }
        ]
      },
      "last_update_date": "2025-04-25T01:48:51.994000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda W30E Stack Overflow Vulnerability (CNVD-2023-18919)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/415611"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18919"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022497"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45512"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/safeemailfilter/readme.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45512"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45512/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18919"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022497"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2689"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45512"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18919"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022497"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2689"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45512"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-18919"
          },
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022497"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2689"
          },
          {
            "date": "2022-12-08T16:15:14.173000",
            "db": "NVD",
            "id": "CVE-2022-45512"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-18919"
          },
          {
            "date": "2023-11-17T08:19:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022497"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2689"
          },
          {
            "date": "2025-04-23T15:15:56.030000",
            "db": "NVD",
            "id": "CVE-2022-45512"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2689"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022497"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2689"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0969

    Vulnerability from variot - Updated: 2025-04-25 01:48

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the account parameter at /goform/addUserName. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0969",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v1.0.1.25(633)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18918"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022500"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45509"
          }
        ]
      },
      "cve": "CVE-2022-45509",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2023-18918",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45509",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45509",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45509",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45509",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45509",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2023-18918",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2692",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18918"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022500"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2692"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45509"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45509"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the account parameter at /goform/addUserName. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45509"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022500"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-18918"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45509",
            "trust": 3.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022500",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-18918",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2692",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18918"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022500"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2692"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45509"
          }
        ]
      },
      "id": "VAR-202212-0969",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18918"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18918"
          }
        ]
      },
      "last_update_date": "2025-04-25T01:48:51.970000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda W30E Stack Overflow Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/415601"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18918"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022500"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45509"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/addusername/readme.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45509"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45509/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18918"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022500"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2692"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45509"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18918"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022500"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2692"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45509"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-03-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-18918"
          },
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022500"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2692"
          },
          {
            "date": "2022-12-08T16:15:14.040000",
            "db": "NVD",
            "id": "CVE-2022-45509"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-18918"
          },
          {
            "date": "2023-11-17T08:19:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022500"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2692"
          },
          {
            "date": "2025-04-23T15:15:55.563000",
            "db": "NVD",
            "id": "CVE-2022-45509"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2692"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022500"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2692"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0883

    Vulnerability from variot - Updated: 2025-04-25 01:46

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the entries parameter at /goform/addressNat. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0883",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v1.0.1.25(633)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18923"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022494"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45515"
          }
        ]
      },
      "cve": "CVE-2022-45515",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2023-18923",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45515",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45515",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45515",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45515",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45515",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2023-18923",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2686",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18923"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022494"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2686"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45515"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45515"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the entries parameter at /goform/addressNat. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45515"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022494"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-18923"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45515",
            "trust": 3.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022494",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-18923",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2686",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18923"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022494"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2686"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45515"
          }
        ]
      },
      "id": "VAR-202212-0883",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18923"
          }
        ],
        "trust": 1.0044734499999999
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18923"
          }
        ]
      },
      "last_update_date": "2025-04-25T01:46:17.159000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda W30E Stack Overflow Vulnerability (CNVD-2023-18923)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/415626"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18923"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022494"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45515"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/addressnat/readme.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45515"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45515/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18923"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022494"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2686"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45515"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-18923"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022494"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2686"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45515"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-18923"
          },
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022494"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2686"
          },
          {
            "date": "2022-12-08T16:15:14.303000",
            "db": "NVD",
            "id": "CVE-2022-45515"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-18923"
          },
          {
            "date": "2023-11-17T08:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022494"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2686"
          },
          {
            "date": "2025-04-23T15:15:56.520000",
            "db": "NVD",
            "id": "CVE-2022-45515"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2686"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022494"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2686"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0928

    Vulnerability from variot - Updated: 2025-04-25 01:44

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/VirtualSer. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0928",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022492"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45517"
          }
        ]
      },
      "cve": "CVE-2022-45517",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45517",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45517",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45517",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45517",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45517",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2684",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022492"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2684"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45517"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45517"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/VirtualSer. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45517"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022492"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45517",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022492",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2684",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022492"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2684"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45517"
          }
        ]
      },
      "id": "VAR-202212-0928",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40447345
      },
      "last_update_date": "2025-04-25T01:44:27.942000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022492"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45517"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/virtualser/readme.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45517"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45517/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022492"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2684"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45517"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022492"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2684"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45517"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022492"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2684"
          },
          {
            "date": "2022-12-08T16:15:14.390000",
            "db": "NVD",
            "id": "CVE-2022-45517"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T08:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022492"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2684"
          },
          {
            "date": "2025-04-23T15:15:56.833000",
            "db": "NVD",
            "id": "CVE-2022-45517"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2684"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022492"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2684"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0938

    Vulnerability from variot - Updated: 2025-04-25 01:42

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the opttype parameter at /goform/IPSECsave. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0938",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022485"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45524"
          }
        ]
      },
      "cve": "CVE-2022-45524",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45524",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45524",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45524",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45524",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45524",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2676",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022485"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2676"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45524"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45524"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the opttype parameter at /goform/IPSECsave. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45524"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022485"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45524",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022485",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2676",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022485"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2676"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45524"
          }
        ]
      },
      "id": "VAR-202212-0938",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40447345
      },
      "last_update_date": "2025-04-25T01:42:20.307000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022485"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45524"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/ipsecsave/readme.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45524"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45524/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022485"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2676"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45524"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022485"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2676"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45524"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022485"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2676"
          },
          {
            "date": "2022-12-08T16:15:14.697000",
            "db": "NVD",
            "id": "CVE-2022-45524"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T08:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022485"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2676"
          },
          {
            "date": "2025-04-23T15:15:57.940000",
            "db": "NVD",
            "id": "CVE-2022-45524"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2676"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022485"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2676"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-1022

    Vulnerability from variot - Updated: 2025-04-25 01:42

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeUrlFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1022",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022488"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45521"
          }
        ]
      },
      "cve": "CVE-2022-45521",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45521",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45521",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45521",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45521",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45521",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2680",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022488"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2680"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45521"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45521"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeUrlFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45521"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022488"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45521",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022488",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2680",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022488"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2680"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45521"
          }
        ]
      },
      "id": "VAR-202212-1022",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40447345
      },
      "last_update_date": "2025-04-25T01:42:20.282000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022488"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45521"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/safeurlfilter/readme.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45521"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45521/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022488"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2680"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45521"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022488"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2680"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45521"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022488"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2680"
          },
          {
            "date": "2022-12-08T16:15:14.563000",
            "db": "NVD",
            "id": "CVE-2022-45521"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T08:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022488"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2680"
          },
          {
            "date": "2025-04-23T15:15:57.480000",
            "db": "NVD",
            "id": "CVE-2022-45521"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2680"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022488"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2680"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0850

    Vulnerability from variot - Updated: 2025-04-25 01:41

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/NatStaticSetting. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0850",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022493"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45516"
          }
        ]
      },
      "cve": "CVE-2022-45516",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45516",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45516",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45516",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45516",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45516",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2685",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022493"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2685"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45516"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45516"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/NatStaticSetting. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45516"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022493"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45516",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022493",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2685",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022493"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2685"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45516"
          }
        ]
      },
      "id": "VAR-202212-0850",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40447345
      },
      "last_update_date": "2025-04-25T01:41:45.637000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022493"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45516"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/natstaticsetting/readme.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45516"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45516/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022493"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2685"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45516"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022493"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2685"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45516"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022493"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2685"
          },
          {
            "date": "2022-12-08T16:15:14.347000",
            "db": "NVD",
            "id": "CVE-2022-45516"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T08:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022493"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2685"
          },
          {
            "date": "2025-04-23T15:15:56.677000",
            "db": "NVD",
            "id": "CVE-2022-45516"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2685"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022493"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2685"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0913

    Vulnerability from variot - Updated: 2025-04-25 01:41

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the cmdinput parameter at /goform/exeCommand. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0913",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022504"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45505"
          }
        ]
      },
      "cve": "CVE-2022-45505",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45505",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45505",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45505",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45505",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45505",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2696",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022504"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2696"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45505"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45505"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the cmdinput parameter at /goform/exeCommand. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45505"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022504"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45505",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022504",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2696",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022504"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2696"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45505"
          }
        ]
      },
      "id": "VAR-202212-0913",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40447345
      },
      "last_update_date": "2025-04-25T01:41:45.596000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022504"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45505"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/execommand/readme.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45505"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45505/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022504"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2696"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45505"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022504"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2696"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45505"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022504"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2696"
          },
          {
            "date": "2022-12-08T16:15:13.870000",
            "db": "NVD",
            "id": "CVE-2022-45505"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T08:19:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022504"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2696"
          },
          {
            "date": "2025-04-23T15:15:54.923000",
            "db": "NVD",
            "id": "CVE-2022-45505"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2696"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022504"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2696"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0934

    Vulnerability from variot - Updated: 2025-04-25 01:41

    Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the PPPOEPassword parameter at /goform/QuickIndex. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0934",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.1.25\\(633\\)"
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "w30e  firmware  1.0.1.25(633)"
          },
          {
            "model": "w30e",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "w30e",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022498"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45511"
          }
        ]
      },
      "cve": "CVE-2022-45511",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45511",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45511",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45511",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45511",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45511",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-2690",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022498"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2690"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45511"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45511"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the PPPOEPassword parameter at /goform/QuickIndex. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45511"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022498"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45511",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022498",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2690",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022498"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2690"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45511"
          }
        ]
      },
      "id": "VAR-202212-0934",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40447345
      },
      "last_update_date": "2025-04-25T01:41:45.576000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022498"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45511"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/quickindex/readme.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45511"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45511/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022498"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2690"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45511"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022498"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2690"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45511"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022498"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2690"
          },
          {
            "date": "2022-12-08T16:15:14.127000",
            "db": "NVD",
            "id": "CVE-2022-45511"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-17T08:19:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-022498"
          },
          {
            "date": "2022-12-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-2690"
          },
          {
            "date": "2025-04-23T15:15:55.873000",
            "db": "NVD",
            "id": "CVE-2022-45511"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2690"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-022498"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-2690"
          }
        ],
        "trust": 0.6
      }
    }