Search criteria
4 vulnerabilities found for vision1210_firmware by unitronics
CVE-2023-6448 (GCVE-0-2023-6448)
Vulnerability from nvd – Published: 2023-12-05 17:43 – Updated: 2025-10-21 23:05
VLAI?
Title
Unitronics VisiLogic uses a default administrative password
Summary
Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.
Severity ?
9.8 (Critical)
CWE
- CWE-1188 - Insecure Default Initialization of Resource
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Unitronics | VisiLogic |
Affected:
0 , < 9.9.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:28:21.839Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.unitronicsplc.com/cyber_security_vision-samba/"
},
{
"tags": [
"release-notes",
"x_transferred"
],
"url": "https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:unitronics:visilogic:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "visilogic",
"vendor": "unitronics",
"versions": [
{
"lessThan": "9.9.00",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-6448",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2023-12-06T14:07:21.216497Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2023-12-11",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-6448"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:05:30.290Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-6448"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-12-11T00:00:00+00:00",
"value": "CVE-2023-6448 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "VisiLogic",
"vendor": "Unitronics",
"versions": [
{
"lessThan": "9.9.00",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-11-28T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.\u003cbr\u003e"
}
],
"value": "Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1188",
"description": "CWE-1188 Insecure Default Initialization of Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-19T16:23:39.022Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems"
},
{
"url": "https://www.unitronicsplc.com/cyber_security_vision-samba/"
},
{
"tags": [
"release-notes"
],
"url": "https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unitronics VisiLogic uses a default administrative password",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2023-6448",
"datePublished": "2023-12-05T17:43:40.451Z",
"dateReserved": "2023-11-30T18:40:51.463Z",
"dateUpdated": "2025-10-21T23:05:30.290Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-2003 (GCVE-0-2023-2003)
Vulnerability from nvd – Published: 2023-07-13 11:25 – Updated: 2024-10-30 16:04
VLAI?
Title
Embedded malicious code vulnerability in Unitronics Vision1210
Summary
Embedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device's data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device.
Severity ?
9.1 (Critical)
CWE
- CWE-506 - Embedded Malicious Code
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Unitronics | Vision1210 |
Affected:
4.3, build 5
|
Credits
Carlos Antonini Cepeda
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:05:27.093Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/embedded-malicious-code-vulnerability-unitronics-vision1210"
},
{
"tags": [
"related",
"technical-description",
"x_transferred"
],
"url": "https://www.hackplayers.com/2023/07/vulnerabilidad-vision1210-unitronics.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:unitronics:vision1210:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "vision1210",
"vendor": "unitronics",
"versions": [
{
"status": "affected",
"version": "4.3, build 5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-2003",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-30T16:03:15.608159Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-30T16:04:09.807Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Vision1210",
"vendor": "Unitronics",
"versions": [
{
"status": "affected",
"version": "4.3, build 5"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Carlos Antonini Cepeda"
}
],
"datePublic": "2023-07-06T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eEmbedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device\u0027s data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device.\u003c/span\u003e\n\n"
}
],
"value": "Embedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device\u0027s data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-636",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-636: Hiding Malicious Data or Code within Files"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-506",
"description": "CWE-506: Embedded Malicious Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-17T10:11:18.273Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/embedded-malicious-code-vulnerability-unitronics-vision1210"
},
{
"tags": [
"related",
"technical-description"
],
"url": "https://www.hackplayers.com/2023/07/vulnerabilidad-vision1210-unitronics.html"
}
],
"source": {
"advisory": "INCIBE-2023-0253",
"discovery": "EXTERNAL"
},
"title": "Embedded malicious code vulnerability in Unitronics Vision1210",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2023-2003",
"datePublished": "2023-07-13T11:25:03.096Z",
"dateReserved": "2023-04-12T14:08:51.192Z",
"dateUpdated": "2024-10-30T16:04:09.807Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6448 (GCVE-0-2023-6448)
Vulnerability from cvelistv5 – Published: 2023-12-05 17:43 – Updated: 2025-10-21 23:05
VLAI?
Title
Unitronics VisiLogic uses a default administrative password
Summary
Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.
Severity ?
9.8 (Critical)
CWE
- CWE-1188 - Insecure Default Initialization of Resource
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Unitronics | VisiLogic |
Affected:
0 , < 9.9.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:28:21.839Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.unitronicsplc.com/cyber_security_vision-samba/"
},
{
"tags": [
"release-notes",
"x_transferred"
],
"url": "https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:unitronics:visilogic:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "visilogic",
"vendor": "unitronics",
"versions": [
{
"lessThan": "9.9.00",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-6448",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2023-12-06T14:07:21.216497Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2023-12-11",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-6448"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:05:30.290Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-6448"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-12-11T00:00:00+00:00",
"value": "CVE-2023-6448 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "VisiLogic",
"vendor": "Unitronics",
"versions": [
{
"lessThan": "9.9.00",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-11-28T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.\u003cbr\u003e"
}
],
"value": "Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1188",
"description": "CWE-1188 Insecure Default Initialization of Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-19T16:23:39.022Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems"
},
{
"url": "https://www.unitronicsplc.com/cyber_security_vision-samba/"
},
{
"tags": [
"release-notes"
],
"url": "https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unitronics VisiLogic uses a default administrative password",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2023-6448",
"datePublished": "2023-12-05T17:43:40.451Z",
"dateReserved": "2023-11-30T18:40:51.463Z",
"dateUpdated": "2025-10-21T23:05:30.290Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-2003 (GCVE-0-2023-2003)
Vulnerability from cvelistv5 – Published: 2023-07-13 11:25 – Updated: 2024-10-30 16:04
VLAI?
Title
Embedded malicious code vulnerability in Unitronics Vision1210
Summary
Embedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device's data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device.
Severity ?
9.1 (Critical)
CWE
- CWE-506 - Embedded Malicious Code
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Unitronics | Vision1210 |
Affected:
4.3, build 5
|
Credits
Carlos Antonini Cepeda
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:05:27.093Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/embedded-malicious-code-vulnerability-unitronics-vision1210"
},
{
"tags": [
"related",
"technical-description",
"x_transferred"
],
"url": "https://www.hackplayers.com/2023/07/vulnerabilidad-vision1210-unitronics.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:unitronics:vision1210:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "vision1210",
"vendor": "unitronics",
"versions": [
{
"status": "affected",
"version": "4.3, build 5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-2003",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-30T16:03:15.608159Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-30T16:04:09.807Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Vision1210",
"vendor": "Unitronics",
"versions": [
{
"status": "affected",
"version": "4.3, build 5"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Carlos Antonini Cepeda"
}
],
"datePublic": "2023-07-06T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eEmbedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device\u0027s data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device.\u003c/span\u003e\n\n"
}
],
"value": "Embedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device\u0027s data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-636",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-636: Hiding Malicious Data or Code within Files"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-506",
"description": "CWE-506: Embedded Malicious Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-17T10:11:18.273Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/embedded-malicious-code-vulnerability-unitronics-vision1210"
},
{
"tags": [
"related",
"technical-description"
],
"url": "https://www.hackplayers.com/2023/07/vulnerabilidad-vision1210-unitronics.html"
}
],
"source": {
"advisory": "INCIBE-2023-0253",
"discovery": "EXTERNAL"
},
"title": "Embedded malicious code vulnerability in Unitronics Vision1210",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2023-2003",
"datePublished": "2023-07-13T11:25:03.096Z",
"dateReserved": "2023-04-12T14:08:51.192Z",
"dateUpdated": "2024-10-30T16:04:09.807Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}