Search criteria
8 vulnerabilities found for verastream_host_integrator by microfocus
CVE-2021-22523 (GCVE-0-2021-22523)
Vulnerability from nvd – Published: 2021-07-22 11:11 – Updated: 2024-08-03 18:44
VLAI?
Summary
XML External Entity vulnerability in Micro Focus Verastream Host Integrator, affecting version 7.8 Update 1 and earlier versions. The vulnerability could allow the control of web browser and hijacking user sessions.
Severity ?
No CVSS data available.
CWE
- XML External Entity.
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Verastream Host Integrator. |
Affected:
Version 7.8 Update 1 and earlier versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:44:14.036Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7025169"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Verastream Host Integrator.",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Version 7.8 Update 1 and earlier versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "XML External Entity vulnerability in Micro Focus Verastream Host Integrator, affecting version 7.8 Update 1 and earlier versions. The vulnerability could allow the control of web browser and hijacking user sessions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "XML External Entity.",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-22T11:11:26.000Z",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7025169"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2021-22523",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Verastream Host Integrator.",
"version": {
"version_data": [
{
"version_value": "Version 7.8 Update 1 and earlier versions."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "XML External Entity vulnerability in Micro Focus Verastream Host Integrator, affecting version 7.8 Update 1 and earlier versions. The vulnerability could allow the control of web browser and hijacking user sessions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "XML External Entity."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.microfocus.com/kb/doc.php?id=7025169",
"refsource": "MISC",
"url": "https://support.microfocus.com/kb/doc.php?id=7025169"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2021-22523",
"datePublished": "2021-07-22T11:11:26.000Z",
"dateReserved": "2021-01-05T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:44:14.036Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22522 (GCVE-0-2021-22522)
Vulnerability from nvd – Published: 2021-07-22 11:08 – Updated: 2024-08-03 18:44
VLAI?
Summary
Reflected Cross-Site Scripting vulnerability in Micro Focus Verastream Host Integrator, affecting version version 7.8 Update 1 and earlier versions. The vulnerability could allow disclosure of confidential data.
Severity ?
No CVSS data available.
CWE
- Reflected Cross-Site Scripting.
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Verastream Host Integrator. |
Affected:
version 7.8 Update 1 and earlier versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:44:14.135Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7025169"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Verastream Host Integrator.",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "version 7.8 Update 1 and earlier versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Reflected Cross-Site Scripting vulnerability in Micro Focus Verastream Host Integrator, affecting version version 7.8 Update 1 and earlier versions. The vulnerability could allow disclosure of confidential data."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Reflected Cross-Site Scripting.",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-22T11:08:03.000Z",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7025169"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2021-22522",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Verastream Host Integrator.",
"version": {
"version_data": [
{
"version_value": "version 7.8 Update 1 and earlier versions."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Reflected Cross-Site Scripting vulnerability in Micro Focus Verastream Host Integrator, affecting version version 7.8 Update 1 and earlier versions. The vulnerability could allow disclosure of confidential data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Reflected Cross-Site Scripting."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.microfocus.com/kb/doc.php?id=7025169",
"refsource": "MISC",
"url": "https://support.microfocus.com/kb/doc.php?id=7025169"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2021-22522",
"datePublished": "2021-07-22T11:08:03.000Z",
"dateReserved": "2021-01-05T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:44:14.135Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-11842 (GCVE-0-2020-11842)
Vulnerability from nvd – Published: 2020-05-04 12:31 – Updated: 2024-08-04 11:42
VLAI?
Summary
Information disclosure vulnerability in Micro Focus Verastream Host Integrator (VHI) product, affecting versions earlier than 7.8 Update 1 (7.8.49 or 7.8.0.49). The vulnerability allows an unauthenticated attackers to view information they may not have been authorized to view.
Severity ?
No CVSS data available.
CWE
- Information disclosure vulnerability
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Verastream Host Integrator (VHI) |
Affected:
versions earlier than 7.8 Update 1 (7.8.49 or 7.8.0.49).
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:42:00.557Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7024567"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Verastream Host Integrator (VHI)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "versions earlier than 7.8 Update 1 (7.8.49 or 7.8.0.49)."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Information disclosure vulnerability in Micro Focus Verastream Host Integrator (VHI) product, affecting versions earlier than 7.8 Update 1 (7.8.49 or 7.8.0.49). The vulnerability allows an unauthenticated attackers to view information they may not have been authorized to view."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information disclosure vulnerability",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-05-04T12:31:13.000Z",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7024567"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2020-11842",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Verastream Host Integrator (VHI)",
"version": {
"version_data": [
{
"version_value": "versions earlier than 7.8 Update 1 (7.8.49 or 7.8.0.49)."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Information disclosure vulnerability in Micro Focus Verastream Host Integrator (VHI) product, affecting versions earlier than 7.8 Update 1 (7.8.49 or 7.8.0.49). The vulnerability allows an unauthenticated attackers to view information they may not have been authorized to view."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information disclosure vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.microfocus.com/kb/doc.php?id=7024567",
"refsource": "MISC",
"url": "https://support.microfocus.com/kb/doc.php?id=7024567"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2020-11842",
"datePublished": "2020-05-04T12:31:13.000Z",
"dateReserved": "2020-04-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:42:00.557Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11654 (GCVE-0-2019-11654)
Vulnerability from nvd – Published: 2019-08-23 17:20 – Updated: 2024-08-04 23:03
VLAI?
Title
A path traversal vulnerability has been identified in Verastream Host Integrator
Summary
Path traversal vulnerability in Micro Focus Verastream Host Integrator (VHI), versions 7.7 SP2 and earlier, The vulnerability allows remote unauthenticated attackers to read arbitrary files.
Severity ?
8.6 (High)
CWE
- A path traversal vulnerability has been identified in Verastream Host Integrator (VHI). The vulnerability allows remote unauthenticated attackers to read arbitrary files.
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Micro Focus | Verastream Host Integrator |
Affected:
unspecified , < 7.7 SP2
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:03:31.538Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7024061"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Verastream Host Integrator",
"vendor": "Micro Focus",
"versions": [
{
"lessThan": "7.7 SP2",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Path traversal vulnerability in Micro Focus Verastream Host Integrator (VHI), versions 7.7 SP2 and earlier, The vulnerability allows remote unauthenticated attackers to read arbitrary files."
}
],
"exploits": [
{
"lang": "en",
"value": "Path traversal"
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "A path traversal vulnerability has been identified in Verastream Host Integrator (VHI). The vulnerability allows remote unauthenticated attackers to read arbitrary files.",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:33.000Z",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7024061"
}
],
"solutions": [
{
"lang": "en",
"value": "An update, VHI 7.7 SP2 Update 1, that fixes this vulnerability is available to maintained customers through the download website, https://download.attachmate.com/upgrades. Micro Focus recommends that customers upgrade as soon as possible."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "A path traversal vulnerability has been identified in Verastream Host Integrator",
"x_generator": {
"engine": "Vulnogram 0.0.7"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2019-11654",
"STATE": "PUBLIC",
"TITLE": "A path traversal vulnerability has been identified in Verastream Host Integrator"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Verastream Host Integrator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "7.7 SP2"
}
]
}
}
]
},
"vendor_name": "Micro Focus"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Path traversal vulnerability in Micro Focus Verastream Host Integrator (VHI), versions 7.7 SP2 and earlier, The vulnerability allows remote unauthenticated attackers to read arbitrary files."
}
]
},
"exploit": [
{
"lang": "en",
"value": "Path traversal"
}
],
"generator": {
"engine": "Vulnogram 0.0.7"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "A path traversal vulnerability has been identified in Verastream Host Integrator (VHI). The vulnerability allows remote unauthenticated attackers to read arbitrary files."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.microfocus.com/kb/doc.php?id=7024061",
"refsource": "CONFIRM",
"url": "https://support.microfocus.com/kb/doc.php?id=7024061"
}
]
},
"solution": [
{
"lang": "en",
"value": "An update, VHI 7.7 SP2 Update 1, that fixes this vulnerability is available to maintained customers through the download website, https://download.attachmate.com/upgrades. Micro Focus recommends that customers upgrade as soon as possible."
}
],
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2019-11654",
"datePublished": "2019-08-23T17:20:11.000Z",
"dateReserved": "2019-05-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:03:31.538Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22523 (GCVE-0-2021-22523)
Vulnerability from cvelistv5 – Published: 2021-07-22 11:11 – Updated: 2024-08-03 18:44
VLAI?
Summary
XML External Entity vulnerability in Micro Focus Verastream Host Integrator, affecting version 7.8 Update 1 and earlier versions. The vulnerability could allow the control of web browser and hijacking user sessions.
Severity ?
No CVSS data available.
CWE
- XML External Entity.
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Verastream Host Integrator. |
Affected:
Version 7.8 Update 1 and earlier versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:44:14.036Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7025169"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Verastream Host Integrator.",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Version 7.8 Update 1 and earlier versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "XML External Entity vulnerability in Micro Focus Verastream Host Integrator, affecting version 7.8 Update 1 and earlier versions. The vulnerability could allow the control of web browser and hijacking user sessions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "XML External Entity.",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-22T11:11:26.000Z",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7025169"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2021-22523",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Verastream Host Integrator.",
"version": {
"version_data": [
{
"version_value": "Version 7.8 Update 1 and earlier versions."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "XML External Entity vulnerability in Micro Focus Verastream Host Integrator, affecting version 7.8 Update 1 and earlier versions. The vulnerability could allow the control of web browser and hijacking user sessions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "XML External Entity."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.microfocus.com/kb/doc.php?id=7025169",
"refsource": "MISC",
"url": "https://support.microfocus.com/kb/doc.php?id=7025169"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2021-22523",
"datePublished": "2021-07-22T11:11:26.000Z",
"dateReserved": "2021-01-05T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:44:14.036Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22522 (GCVE-0-2021-22522)
Vulnerability from cvelistv5 – Published: 2021-07-22 11:08 – Updated: 2024-08-03 18:44
VLAI?
Summary
Reflected Cross-Site Scripting vulnerability in Micro Focus Verastream Host Integrator, affecting version version 7.8 Update 1 and earlier versions. The vulnerability could allow disclosure of confidential data.
Severity ?
No CVSS data available.
CWE
- Reflected Cross-Site Scripting.
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Verastream Host Integrator. |
Affected:
version 7.8 Update 1 and earlier versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:44:14.135Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7025169"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Verastream Host Integrator.",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "version 7.8 Update 1 and earlier versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Reflected Cross-Site Scripting vulnerability in Micro Focus Verastream Host Integrator, affecting version version 7.8 Update 1 and earlier versions. The vulnerability could allow disclosure of confidential data."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Reflected Cross-Site Scripting.",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-22T11:08:03.000Z",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7025169"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2021-22522",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Verastream Host Integrator.",
"version": {
"version_data": [
{
"version_value": "version 7.8 Update 1 and earlier versions."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Reflected Cross-Site Scripting vulnerability in Micro Focus Verastream Host Integrator, affecting version version 7.8 Update 1 and earlier versions. The vulnerability could allow disclosure of confidential data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Reflected Cross-Site Scripting."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.microfocus.com/kb/doc.php?id=7025169",
"refsource": "MISC",
"url": "https://support.microfocus.com/kb/doc.php?id=7025169"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2021-22522",
"datePublished": "2021-07-22T11:08:03.000Z",
"dateReserved": "2021-01-05T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:44:14.135Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-11842 (GCVE-0-2020-11842)
Vulnerability from cvelistv5 – Published: 2020-05-04 12:31 – Updated: 2024-08-04 11:42
VLAI?
Summary
Information disclosure vulnerability in Micro Focus Verastream Host Integrator (VHI) product, affecting versions earlier than 7.8 Update 1 (7.8.49 or 7.8.0.49). The vulnerability allows an unauthenticated attackers to view information they may not have been authorized to view.
Severity ?
No CVSS data available.
CWE
- Information disclosure vulnerability
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Verastream Host Integrator (VHI) |
Affected:
versions earlier than 7.8 Update 1 (7.8.49 or 7.8.0.49).
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:42:00.557Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7024567"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Verastream Host Integrator (VHI)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "versions earlier than 7.8 Update 1 (7.8.49 or 7.8.0.49)."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Information disclosure vulnerability in Micro Focus Verastream Host Integrator (VHI) product, affecting versions earlier than 7.8 Update 1 (7.8.49 or 7.8.0.49). The vulnerability allows an unauthenticated attackers to view information they may not have been authorized to view."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information disclosure vulnerability",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-05-04T12:31:13.000Z",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7024567"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2020-11842",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Verastream Host Integrator (VHI)",
"version": {
"version_data": [
{
"version_value": "versions earlier than 7.8 Update 1 (7.8.49 or 7.8.0.49)."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Information disclosure vulnerability in Micro Focus Verastream Host Integrator (VHI) product, affecting versions earlier than 7.8 Update 1 (7.8.49 or 7.8.0.49). The vulnerability allows an unauthenticated attackers to view information they may not have been authorized to view."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information disclosure vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.microfocus.com/kb/doc.php?id=7024567",
"refsource": "MISC",
"url": "https://support.microfocus.com/kb/doc.php?id=7024567"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2020-11842",
"datePublished": "2020-05-04T12:31:13.000Z",
"dateReserved": "2020-04-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:42:00.557Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11654 (GCVE-0-2019-11654)
Vulnerability from cvelistv5 – Published: 2019-08-23 17:20 – Updated: 2024-08-04 23:03
VLAI?
Title
A path traversal vulnerability has been identified in Verastream Host Integrator
Summary
Path traversal vulnerability in Micro Focus Verastream Host Integrator (VHI), versions 7.7 SP2 and earlier, The vulnerability allows remote unauthenticated attackers to read arbitrary files.
Severity ?
8.6 (High)
CWE
- A path traversal vulnerability has been identified in Verastream Host Integrator (VHI). The vulnerability allows remote unauthenticated attackers to read arbitrary files.
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Micro Focus | Verastream Host Integrator |
Affected:
unspecified , < 7.7 SP2
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:03:31.538Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7024061"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Verastream Host Integrator",
"vendor": "Micro Focus",
"versions": [
{
"lessThan": "7.7 SP2",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Path traversal vulnerability in Micro Focus Verastream Host Integrator (VHI), versions 7.7 SP2 and earlier, The vulnerability allows remote unauthenticated attackers to read arbitrary files."
}
],
"exploits": [
{
"lang": "en",
"value": "Path traversal"
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "A path traversal vulnerability has been identified in Verastream Host Integrator (VHI). The vulnerability allows remote unauthenticated attackers to read arbitrary files.",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-06T16:15:33.000Z",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "microfocus"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.microfocus.com/kb/doc.php?id=7024061"
}
],
"solutions": [
{
"lang": "en",
"value": "An update, VHI 7.7 SP2 Update 1, that fixes this vulnerability is available to maintained customers through the download website, https://download.attachmate.com/upgrades. Micro Focus recommends that customers upgrade as soon as possible."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "A path traversal vulnerability has been identified in Verastream Host Integrator",
"x_generator": {
"engine": "Vulnogram 0.0.7"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@microfocus.com",
"ID": "CVE-2019-11654",
"STATE": "PUBLIC",
"TITLE": "A path traversal vulnerability has been identified in Verastream Host Integrator"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Verastream Host Integrator",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "7.7 SP2"
}
]
}
}
]
},
"vendor_name": "Micro Focus"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Path traversal vulnerability in Micro Focus Verastream Host Integrator (VHI), versions 7.7 SP2 and earlier, The vulnerability allows remote unauthenticated attackers to read arbitrary files."
}
]
},
"exploit": [
{
"lang": "en",
"value": "Path traversal"
}
],
"generator": {
"engine": "Vulnogram 0.0.7"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "A path traversal vulnerability has been identified in Verastream Host Integrator (VHI). The vulnerability allows remote unauthenticated attackers to read arbitrary files."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.microfocus.com/kb/doc.php?id=7024061",
"refsource": "CONFIRM",
"url": "https://support.microfocus.com/kb/doc.php?id=7024061"
}
]
},
"solution": [
{
"lang": "en",
"value": "An update, VHI 7.7 SP2 Update 1, that fixes this vulnerability is available to maintained customers through the download website, https://download.attachmate.com/upgrades. Micro Focus recommends that customers upgrade as soon as possible."
}
],
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "microfocus",
"cveId": "CVE-2019-11654",
"datePublished": "2019-08-23T17:20:11.000Z",
"dateReserved": "2019-05-01T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:03:31.538Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}