Search
Find a vulnerability
Search criteria
2 vulnerabilities found for tradfri_gateway_e1526_firmware by ikea
CVE-2022-39065 (GCVE-0-2022-39065)
Vulnerability from nvd – Published: 2022-10-14 00:00 – Updated: 2025-05-15 13:46
VLAI
Summary
A single malformed IEEE 802.15.4 (Zigbee) frame makes the TRÅDFRI gateway unresponsive, such that connected lighting cannot be controlled with the IKEA Home Smart app and TRÅDFRI remote control. The malformed Zigbee frame is an unauthenticated broadcast message, which means all vulnerable devices within radio range are affected. CVSS 3.1 Base Score: 6.5 Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-241 - Improper Handling of Unexpected Data Type
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Ikea | TRÅDFRI gateway system |
Affected:
< 1.19.26
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.391Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-ikea-tradfri-smart-lighting-gateway/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-39065",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-15T13:44:59.292209Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-15T13:46:29.965Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "TR\u00c5DFRI gateway system",
"vendor": "Ikea",
"versions": [
{
"status": "affected",
"version": "\u003c 1.19.26"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A single malformed IEEE 802.15.4 (Zigbee) frame makes the TR\u00c5DFRI gateway unresponsive, such that connected lighting cannot be controlled with the IKEA Home Smart app and TR\u00c5DFRI remote control. The malformed Zigbee frame is an unauthenticated broadcast message, which means all vulnerable devices within radio range are affected. CVSS 3.1 Base Score: 6.5 Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-241",
"description": "CWE-241: Improper Handling of Unexpected Data Type",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-14T00:00:00.000Z",
"orgId": "8cad7728-009c-4a3d-a95e-ca62e6ff8a0b",
"shortName": "SNPS"
},
"references": [
{
"url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-ikea-tradfri-smart-lighting-gateway/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8cad7728-009c-4a3d-a95e-ca62e6ff8a0b",
"assignerShortName": "SNPS",
"cveId": "CVE-2022-39065",
"datePublished": "2022-10-14T00:00:00.000Z",
"dateReserved": "2022-08-31T00:00:00.000Z",
"dateUpdated": "2025-05-15T13:46:29.965Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39065 (GCVE-0-2022-39065)
Vulnerability from cvelistv5 – Published: 2022-10-14 00:00 – Updated: 2025-05-15 13:46
VLAI
Summary
A single malformed IEEE 802.15.4 (Zigbee) frame makes the TRÅDFRI gateway unresponsive, such that connected lighting cannot be controlled with the IKEA Home Smart app and TRÅDFRI remote control. The malformed Zigbee frame is an unauthenticated broadcast message, which means all vulnerable devices within radio range are affected. CVSS 3.1 Base Score: 6.5 Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-241 - Improper Handling of Unexpected Data Type
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Ikea | TRÅDFRI gateway system |
Affected:
< 1.19.26
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.391Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-ikea-tradfri-smart-lighting-gateway/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-39065",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-15T13:44:59.292209Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-15T13:46:29.965Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "TR\u00c5DFRI gateway system",
"vendor": "Ikea",
"versions": [
{
"status": "affected",
"version": "\u003c 1.19.26"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A single malformed IEEE 802.15.4 (Zigbee) frame makes the TR\u00c5DFRI gateway unresponsive, such that connected lighting cannot be controlled with the IKEA Home Smart app and TR\u00c5DFRI remote control. The malformed Zigbee frame is an unauthenticated broadcast message, which means all vulnerable devices within radio range are affected. CVSS 3.1 Base Score: 6.5 Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-241",
"description": "CWE-241: Improper Handling of Unexpected Data Type",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-14T00:00:00.000Z",
"orgId": "8cad7728-009c-4a3d-a95e-ca62e6ff8a0b",
"shortName": "SNPS"
},
"references": [
{
"url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-ikea-tradfri-smart-lighting-gateway/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8cad7728-009c-4a3d-a95e-ca62e6ff8a0b",
"assignerShortName": "SNPS",
"cveId": "CVE-2022-39065",
"datePublished": "2022-10-14T00:00:00.000Z",
"dateReserved": "2022-08-31T00:00:00.000Z",
"dateUpdated": "2025-05-15T13:46:29.965Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}