Search criteria

8 vulnerabilities found for tapo_l530e_firmware by tp-link

CVE-2023-38907 (GCVE-0-2023-38907)

Vulnerability from nvd – Published: 2023-09-25 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.232Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://arxiv.org/abs/2308.09019"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-07T14:31:52.486653",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
        },
        {
          "url": "https://arxiv.org/abs/2308.09019"
        },
        {
          "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
        },
        {
          "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38907",
    "datePublished": "2023-09-25T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-08-02T17:54:39.232Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38909 (GCVE-0-2023-38909)

Vulnerability from nvd – Published: 2023-08-22 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.599Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://arxiv.org/abs/2308.09019"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://arxiv.org/pdf/2308.09019.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-07T14:26:21.306503",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
        },
        {
          "url": "https://arxiv.org/abs/2308.09019"
        },
        {
          "url": "https://arxiv.org/pdf/2308.09019.pdf"
        },
        {
          "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
        },
        {
          "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38909",
    "datePublished": "2023-08-22T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-08-02T17:54:39.599Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38908 (GCVE-0-2023-38908)

Vulnerability from nvd – Published: 2023-08-22 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.219Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://arxiv.org/abs/2308.09019"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://arxiv.org/pdf/2308.09019.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-07T14:18:59.022586",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
        },
        {
          "url": "https://arxiv.org/abs/2308.09019"
        },
        {
          "url": "https://arxiv.org/pdf/2308.09019.pdf"
        },
        {
          "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
        },
        {
          "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38908",
    "datePublished": "2023-08-22T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-08-02T17:54:39.219Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38906 (GCVE-0-2023-38906)

Vulnerability from nvd – Published: 2023-08-21 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.265Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://arxiv.org/abs/2308.09019"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-07T14:37:00.745727",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
        },
        {
          "url": "https://arxiv.org/abs/2308.09019"
        },
        {
          "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
        },
        {
          "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38906",
    "datePublished": "2023-08-21T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-08-02T17:54:39.265Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38907 (GCVE-0-2023-38907)

Vulnerability from cvelistv5 – Published: 2023-09-25 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.232Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://arxiv.org/abs/2308.09019"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-07T14:31:52.486653",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
        },
        {
          "url": "https://arxiv.org/abs/2308.09019"
        },
        {
          "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
        },
        {
          "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38907",
    "datePublished": "2023-09-25T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-08-02T17:54:39.232Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38908 (GCVE-0-2023-38908)

Vulnerability from cvelistv5 – Published: 2023-08-22 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.219Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://arxiv.org/abs/2308.09019"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://arxiv.org/pdf/2308.09019.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-07T14:18:59.022586",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
        },
        {
          "url": "https://arxiv.org/abs/2308.09019"
        },
        {
          "url": "https://arxiv.org/pdf/2308.09019.pdf"
        },
        {
          "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
        },
        {
          "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38908",
    "datePublished": "2023-08-22T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-08-02T17:54:39.219Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38909 (GCVE-0-2023-38909)

Vulnerability from cvelistv5 – Published: 2023-08-22 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.599Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://arxiv.org/abs/2308.09019"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://arxiv.org/pdf/2308.09019.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-07T14:26:21.306503",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
        },
        {
          "url": "https://arxiv.org/abs/2308.09019"
        },
        {
          "url": "https://arxiv.org/pdf/2308.09019.pdf"
        },
        {
          "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
        },
        {
          "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38909",
    "datePublished": "2023-08-22T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-08-02T17:54:39.599Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38906 (GCVE-0-2023-38906)

Vulnerability from cvelistv5 – Published: 2023-08-21 00:00 – Updated: 2024-08-02 17:54
VLAI?
Summary
An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.265Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://arxiv.org/abs/2308.09019"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-07T14:37:00.745727",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
        },
        {
          "url": "https://arxiv.org/abs/2308.09019"
        },
        {
          "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
        },
        {
          "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38906",
    "datePublished": "2023-08-21T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-08-02T17:54:39.265Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}