Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for tapo_l530e_firmware by tp-link

    CVE-2023-38907 (GCVE-0-2023-38907)

    Vulnerability from nvd – Published: 2023-09-25 00:00 – Updated: 2024-08-02 17:54
    VLAI
    Summary
    An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:54:39.232Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://arxiv.org/abs/2308.09019"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-07T14:31:52.486Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
            },
            {
              "url": "https://arxiv.org/abs/2308.09019"
            },
            {
              "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
            },
            {
              "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-38907",
        "datePublished": "2023-09-25T00:00:00.000Z",
        "dateReserved": "2023-07-25T00:00:00.000Z",
        "dateUpdated": "2024-08-02T17:54:39.232Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38909 (GCVE-0-2023-38909)

    Vulnerability from nvd – Published: 2023-08-22 00:00 – Updated: 2024-08-02 17:54
    VLAI
    Summary
    An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:54:39.599Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://arxiv.org/abs/2308.09019"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://arxiv.org/pdf/2308.09019.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-07T14:26:21.306Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
            },
            {
              "url": "https://arxiv.org/abs/2308.09019"
            },
            {
              "url": "https://arxiv.org/pdf/2308.09019.pdf"
            },
            {
              "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
            },
            {
              "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-38909",
        "datePublished": "2023-08-22T00:00:00.000Z",
        "dateReserved": "2023-07-25T00:00:00.000Z",
        "dateUpdated": "2024-08-02T17:54:39.599Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38908 (GCVE-0-2023-38908)

    Vulnerability from nvd – Published: 2023-08-22 00:00 – Updated: 2024-08-02 17:54
    VLAI
    Summary
    An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:54:39.219Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://arxiv.org/abs/2308.09019"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://arxiv.org/pdf/2308.09019.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-07T14:18:59.022Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
            },
            {
              "url": "https://arxiv.org/abs/2308.09019"
            },
            {
              "url": "https://arxiv.org/pdf/2308.09019.pdf"
            },
            {
              "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
            },
            {
              "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-38908",
        "datePublished": "2023-08-22T00:00:00.000Z",
        "dateReserved": "2023-07-25T00:00:00.000Z",
        "dateUpdated": "2024-08-02T17:54:39.219Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38906 (GCVE-0-2023-38906)

    Vulnerability from nvd – Published: 2023-08-21 00:00 – Updated: 2024-08-02 17:54
    VLAI
    Summary
    An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:54:39.265Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://arxiv.org/abs/2308.09019"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-07T14:37:00.745Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
            },
            {
              "url": "https://arxiv.org/abs/2308.09019"
            },
            {
              "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
            },
            {
              "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-38906",
        "datePublished": "2023-08-21T00:00:00.000Z",
        "dateReserved": "2023-07-25T00:00:00.000Z",
        "dateUpdated": "2024-08-02T17:54:39.265Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38907 (GCVE-0-2023-38907)

    Vulnerability from cvelistv5 – Published: 2023-09-25 00:00 – Updated: 2024-08-02 17:54
    VLAI
    Summary
    An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:54:39.232Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://arxiv.org/abs/2308.09019"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to replay old messages encrypted with a still valid session key."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-07T14:31:52.486Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
            },
            {
              "url": "https://arxiv.org/abs/2308.09019"
            },
            {
              "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
            },
            {
              "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-38907",
        "datePublished": "2023-09-25T00:00:00.000Z",
        "dateReserved": "2023-07-25T00:00:00.000Z",
        "dateUpdated": "2024-08-02T17:54:39.232Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38908 (GCVE-0-2023-38908)

    Vulnerability from cvelistv5 – Published: 2023-08-22 00:00 – Updated: 2024-08-02 17:54
    VLAI
    Summary
    An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:54:39.219Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://arxiv.org/abs/2308.09019"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://arxiv.org/pdf/2308.09019.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the TSKEP authentication function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-07T14:18:59.022Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
            },
            {
              "url": "https://arxiv.org/abs/2308.09019"
            },
            {
              "url": "https://arxiv.org/pdf/2308.09019.pdf"
            },
            {
              "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
            },
            {
              "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-38908",
        "datePublished": "2023-08-22T00:00:00.000Z",
        "dateReserved": "2023-07-25T00:00:00.000Z",
        "dateUpdated": "2024-08-02T17:54:39.219Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38909 (GCVE-0-2023-38909)

    Vulnerability from cvelistv5 – Published: 2023-08-22 00:00 – Updated: 2024-08-02 17:54
    VLAI
    Summary
    An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:54:39.599Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://arxiv.org/abs/2308.09019"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://arxiv.org/pdf/2308.09019.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in TPLink Smart Bulb Tapo series L530 before 1.2.4, L510E before 1.1.0, L630 before 1.0.4, P100 before 1.5.0, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the IV component in the AES128-CBC function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-07T14:26:21.306Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
            },
            {
              "url": "https://arxiv.org/abs/2308.09019"
            },
            {
              "url": "https://arxiv.org/pdf/2308.09019.pdf"
            },
            {
              "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
            },
            {
              "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-38909",
        "datePublished": "2023-08-22T00:00:00.000Z",
        "dateReserved": "2023-07-25T00:00:00.000Z",
        "dateUpdated": "2024-08-02T17:54:39.599Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38906 (GCVE-0-2023-38906)

    Vulnerability from cvelistv5 – Published: 2023-08-21 00:00 – Updated: 2024-08-02 17:54
    VLAI
    Summary
    An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:54:39.265Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://arxiv.org/abs/2308.09019"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-07T14:37:00.745Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=\u0026t=1"
            },
            {
              "url": "https://arxiv.org/abs/2308.09019"
            },
            {
              "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf"
            },
            {
              "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-38906",
        "datePublished": "2023-08-21T00:00:00.000Z",
        "dateReserved": "2023-07-25T00:00:00.000Z",
        "dateUpdated": "2024-08-02T17:54:39.265Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }