Search
Find a vulnerability
Search criteria
8 vulnerabilities found for sun_zfs_storage_appliance_kit_software by oracle
CVE-2020-3909 (GCVE-0-2020-3909)
Vulnerability from nvd – Published: 2020-04-01 17:53 – Updated: 2024-08-04 07:52
VLAI
Summary
A buffer overflow was addressed with improved bounds checking. This issue is fixed in iOS 13.4 and iPadOS 13.4, macOS Catalina 10.15.4, tvOS 13.4, watchOS 6.2, iTunes for Windows 12.10.5, iCloud for Windows 10.9.3, iCloud for Windows 7.18. Multiple issues in libxml2.
Severity
No CVSS data available.
CWE
- Multiple issues in libxml2
Assigner
References
8 references
| URL | Tags |
|---|---|
| https://support.apple.com/HT211100 | x_refsource_MISC |
| https://support.apple.com/HT211102 | x_refsource_MISC |
| https://support.apple.com/HT211101 | x_refsource_MISC |
| https://support.apple.com/HT211103 | x_refsource_MISC |
| https://support.apple.com/HT211105 | x_refsource_MISC |
| https://support.apple.com/HT211106 | x_refsource_MISC |
| https://support.apple.com/HT211107 | x_refsource_MISC |
| https://www.oracle.com/security-alerts/cpuoct2020.html | x_refsource_MISC |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Apple | iOS |
Affected:
unspecified , < iOS 13.4 and iPadOS 13.4
(custom)
|
|
| Apple | macOS |
Affected:
unspecified , < macOS Catalina 10.15.4
(custom)
|
|
| Apple | tvOS |
Affected:
unspecified , < tvOS 13.4
(custom)
|
|
| Apple | watchOS |
Affected:
unspecified , < watchOS 6.2
(custom)
|
|
| Apple | iTunes for Windows |
Affected:
unspecified , < iTunes for Windows 12.10.5
(custom)
|
|
| Apple | iCloud for Windows |
Affected:
unspecified , < iCloud for Windows 10.9.3
(custom)
|
|
| Apple | iCloud for Windows (Legacy) |
Affected:
unspecified , < iCloud for Windows 7.18
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T07:52:20.628Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211100"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211102"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211101"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211103"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211105"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211106"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211107"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuoct2020.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iOS",
"vendor": "Apple",
"versions": [
{
"lessThan": "iOS 13.4 and iPadOS 13.4",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "macOS",
"vendor": "Apple",
"versions": [
{
"lessThan": "macOS Catalina 10.15.4",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "tvOS",
"vendor": "Apple",
"versions": [
{
"lessThan": "tvOS 13.4",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "watchOS",
"vendor": "Apple",
"versions": [
{
"lessThan": "watchOS 6.2",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "iTunes for Windows",
"vendor": "Apple",
"versions": [
{
"lessThan": "iTunes for Windows 12.10.5",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "iCloud for Windows",
"vendor": "Apple",
"versions": [
{
"lessThan": "iCloud for Windows 10.9.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "iCloud for Windows (Legacy)",
"vendor": "Apple",
"versions": [
{
"lessThan": "iCloud for Windows 7.18",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A buffer overflow was addressed with improved bounds checking. This issue is fixed in iOS 13.4 and iPadOS 13.4, macOS Catalina 10.15.4, tvOS 13.4, watchOS 6.2, iTunes for Windows 12.10.5, iCloud for Windows 10.9.3, iCloud for Windows 7.18. Multiple issues in libxml2."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple issues in libxml2",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-20T21:15:04.000Z",
"orgId": "286789f9-fbc2-4510-9f9a-43facdede74c",
"shortName": "apple"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211100"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211102"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211101"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211103"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211105"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211106"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211107"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.oracle.com/security-alerts/cpuoct2020.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "product-security@apple.com",
"ID": "CVE-2020-3909",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iOS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "iOS 13.4 and iPadOS 13.4"
}
]
}
},
{
"product_name": "macOS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "macOS Catalina 10.15.4"
}
]
}
},
{
"product_name": "tvOS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "tvOS 13.4"
}
]
}
},
{
"product_name": "watchOS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "watchOS 6.2"
}
]
}
},
{
"product_name": "iTunes for Windows",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "iTunes for Windows 12.10.5"
}
]
}
},
{
"product_name": "iCloud for Windows",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "iCloud for Windows 10.9.3"
}
]
}
},
{
"product_name": "iCloud for Windows (Legacy)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "iCloud for Windows 7.18"
}
]
}
}
]
},
"vendor_name": "Apple"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A buffer overflow was addressed with improved bounds checking. This issue is fixed in iOS 13.4 and iPadOS 13.4, macOS Catalina 10.15.4, tvOS 13.4, watchOS 6.2, iTunes for Windows 12.10.5, iCloud for Windows 10.9.3, iCloud for Windows 7.18. Multiple issues in libxml2."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple issues in libxml2"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.apple.com/HT211100",
"refsource": "MISC",
"url": "https://support.apple.com/HT211100"
},
{
"name": "https://support.apple.com/HT211102",
"refsource": "MISC",
"url": "https://support.apple.com/HT211102"
},
{
"name": "https://support.apple.com/HT211101",
"refsource": "MISC",
"url": "https://support.apple.com/HT211101"
},
{
"name": "https://support.apple.com/HT211103",
"refsource": "MISC",
"url": "https://support.apple.com/HT211103"
},
{
"name": "https://support.apple.com/HT211105",
"refsource": "MISC",
"url": "https://support.apple.com/HT211105"
},
{
"name": "https://support.apple.com/HT211106",
"refsource": "MISC",
"url": "https://support.apple.com/HT211106"
},
{
"name": "https://support.apple.com/HT211107",
"refsource": "MISC",
"url": "https://support.apple.com/HT211107"
},
{
"name": "https://www.oracle.com/security-alerts/cpuoct2020.html",
"refsource": "MISC",
"url": "https://www.oracle.com/security-alerts/cpuoct2020.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "286789f9-fbc2-4510-9f9a-43facdede74c",
"assignerShortName": "apple",
"cveId": "CVE-2020-3909",
"datePublished": "2020-04-01T17:53:04.000Z",
"dateReserved": "2019-12-18T00:00:00.000Z",
"dateUpdated": "2024-08-04T07:52:20.628Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-10016 (GCVE-0-2017-10016)
Vulnerability from nvd – Published: 2017-08-08 15:00 – Updated: 2024-10-04 19:13
VLAI
Summary
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 7.5 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H).
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/99855 | vdb-entryx_refsource_BID |
| http://www.oracle.com/technetwork/security-adviso… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Oracle Corporation | Sun ZFS Storage Appliance Kit (AK) Software |
Affected:
AK 2013
|
Date Public
2017-07-18 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T17:25:00.567Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "99855",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/99855"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-10016",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-04T15:39:58.016951Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-04T19:13:08.104Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Sun ZFS Storage Appliance Kit (AK) Software",
"vendor": "Oracle Corporation",
"versions": [
{
"status": "affected",
"version": "AK 2013"
}
]
}
],
"datePublic": "2017-07-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 7.5 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-09T09:57:01.000Z",
"orgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"shortName": "oracle"
},
"references": [
{
"name": "99855",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/99855"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert_us@oracle.com",
"ID": "CVE-2017-10016",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Sun ZFS Storage Appliance Kit (AK) Software",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "AK 2013"
}
]
}
}
]
},
"vendor_name": "Oracle Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 7.5 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK)."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "99855",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/99855"
},
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"assignerShortName": "oracle",
"cveId": "CVE-2017-10016",
"datePublished": "2017-08-08T15:00:00.000Z",
"dateReserved": "2017-06-21T00:00:00.000Z",
"dateUpdated": "2024-10-04T19:13:08.104Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-10013 (GCVE-0-2017-10013)
Vulnerability from nvd – Published: 2017-08-08 15:00 – Updated: 2024-10-04 19:13
VLAI
Summary
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H).
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/99833 | vdb-entryx_refsource_BID |
| http://www.oracle.com/technetwork/security-adviso… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Oracle Corporation | Sun ZFS Storage Appliance Kit (AK) Software |
Affected:
AK 2013
|
Date Public
2017-07-18 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T17:25:00.456Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "99833",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/99833"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-10013",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-04T15:39:59.176549Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-04T19:13:24.725Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Sun ZFS Storage Appliance Kit (AK) Software",
"vendor": "Oracle Corporation",
"versions": [
{
"status": "affected",
"version": "AK 2013"
}
]
}
],
"datePublic": "2017-07-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-09T09:57:01.000Z",
"orgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"shortName": "oracle"
},
"references": [
{
"name": "99833",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/99833"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert_us@oracle.com",
"ID": "CVE-2017-10013",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Sun ZFS Storage Appliance Kit (AK) Software",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "AK 2013"
}
]
}
}
]
},
"vendor_name": "Oracle Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK)."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "99833",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/99833"
},
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"assignerShortName": "oracle",
"cveId": "CVE-2017-10013",
"datePublished": "2017-08-08T15:00:00.000Z",
"dateReserved": "2017-06-21T00:00:00.000Z",
"dateUpdated": "2024-10-04T19:13:24.725Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-3578 (GCVE-0-2017-3578)
Vulnerability from nvd – Published: 2017-04-24 19:00 – Updated: 2024-10-04 19:20
VLAI
Summary
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Easily "exploitable" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- Easily "exploitable" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).
Assigner
References
3 references
| URL | Tags |
|---|---|
| http://www.oracle.com/technetwork/security-adviso… | x_refsource_CONFIRM |
| http://www.securitytracker.com/id/1038292 | vdb-entryx_refsource_SECTRACK |
| http://www.securityfocus.com/bid/97810 | vdb-entryx_refsource_BID |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Oracle Corporation | Sun ZFS Storage Appliance Kit (AK) Software |
Affected:
AK 2013
|
Date Public
2017-04-18 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:30:57.994Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"name": "1038292",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038292"
},
{
"name": "97810",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/97810"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-3578",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-04T16:22:07.505492Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-04T19:20:10.767Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Sun ZFS Storage Appliance Kit (AK) Software",
"vendor": "Oracle Corporation",
"versions": [
{
"status": "affected",
"version": "AK 2013"
}
]
}
],
"datePublic": "2017-04-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Easily \"exploitable\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Easily \"exploitable\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-07-10T09:57:01.000Z",
"orgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"shortName": "oracle"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"name": "1038292",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038292"
},
{
"name": "97810",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/97810"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert_us@oracle.com",
"ID": "CVE-2017-3578",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Sun ZFS Storage Appliance Kit (AK) Software",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "AK 2013"
}
]
}
}
]
},
"vendor_name": "Oracle Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Easily \"exploitable\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Easily \"exploitable\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK)."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"name": "1038292",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1038292"
},
{
"name": "97810",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/97810"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"assignerShortName": "oracle",
"cveId": "CVE-2017-3578",
"datePublished": "2017-04-24T19:00:00.000Z",
"dateReserved": "2016-12-06T00:00:00.000Z",
"dateUpdated": "2024-10-04T19:20:10.767Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-3909 (GCVE-0-2020-3909)
Vulnerability from cvelistv5 – Published: 2020-04-01 17:53 – Updated: 2024-08-04 07:52
VLAI
Summary
A buffer overflow was addressed with improved bounds checking. This issue is fixed in iOS 13.4 and iPadOS 13.4, macOS Catalina 10.15.4, tvOS 13.4, watchOS 6.2, iTunes for Windows 12.10.5, iCloud for Windows 10.9.3, iCloud for Windows 7.18. Multiple issues in libxml2.
Severity
No CVSS data available.
CWE
- Multiple issues in libxml2
Assigner
References
8 references
| URL | Tags |
|---|---|
| https://support.apple.com/HT211100 | x_refsource_MISC |
| https://support.apple.com/HT211102 | x_refsource_MISC |
| https://support.apple.com/HT211101 | x_refsource_MISC |
| https://support.apple.com/HT211103 | x_refsource_MISC |
| https://support.apple.com/HT211105 | x_refsource_MISC |
| https://support.apple.com/HT211106 | x_refsource_MISC |
| https://support.apple.com/HT211107 | x_refsource_MISC |
| https://www.oracle.com/security-alerts/cpuoct2020.html | x_refsource_MISC |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Apple | iOS |
Affected:
unspecified , < iOS 13.4 and iPadOS 13.4
(custom)
|
|
| Apple | macOS |
Affected:
unspecified , < macOS Catalina 10.15.4
(custom)
|
|
| Apple | tvOS |
Affected:
unspecified , < tvOS 13.4
(custom)
|
|
| Apple | watchOS |
Affected:
unspecified , < watchOS 6.2
(custom)
|
|
| Apple | iTunes for Windows |
Affected:
unspecified , < iTunes for Windows 12.10.5
(custom)
|
|
| Apple | iCloud for Windows |
Affected:
unspecified , < iCloud for Windows 10.9.3
(custom)
|
|
| Apple | iCloud for Windows (Legacy) |
Affected:
unspecified , < iCloud for Windows 7.18
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T07:52:20.628Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211100"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211102"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211101"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211103"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211105"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211106"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.apple.com/HT211107"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuoct2020.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iOS",
"vendor": "Apple",
"versions": [
{
"lessThan": "iOS 13.4 and iPadOS 13.4",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "macOS",
"vendor": "Apple",
"versions": [
{
"lessThan": "macOS Catalina 10.15.4",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "tvOS",
"vendor": "Apple",
"versions": [
{
"lessThan": "tvOS 13.4",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "watchOS",
"vendor": "Apple",
"versions": [
{
"lessThan": "watchOS 6.2",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "iTunes for Windows",
"vendor": "Apple",
"versions": [
{
"lessThan": "iTunes for Windows 12.10.5",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "iCloud for Windows",
"vendor": "Apple",
"versions": [
{
"lessThan": "iCloud for Windows 10.9.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "iCloud for Windows (Legacy)",
"vendor": "Apple",
"versions": [
{
"lessThan": "iCloud for Windows 7.18",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A buffer overflow was addressed with improved bounds checking. This issue is fixed in iOS 13.4 and iPadOS 13.4, macOS Catalina 10.15.4, tvOS 13.4, watchOS 6.2, iTunes for Windows 12.10.5, iCloud for Windows 10.9.3, iCloud for Windows 7.18. Multiple issues in libxml2."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple issues in libxml2",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-20T21:15:04.000Z",
"orgId": "286789f9-fbc2-4510-9f9a-43facdede74c",
"shortName": "apple"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211100"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211102"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211101"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211103"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211105"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211106"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.apple.com/HT211107"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.oracle.com/security-alerts/cpuoct2020.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "product-security@apple.com",
"ID": "CVE-2020-3909",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iOS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "iOS 13.4 and iPadOS 13.4"
}
]
}
},
{
"product_name": "macOS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "macOS Catalina 10.15.4"
}
]
}
},
{
"product_name": "tvOS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "tvOS 13.4"
}
]
}
},
{
"product_name": "watchOS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "watchOS 6.2"
}
]
}
},
{
"product_name": "iTunes for Windows",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "iTunes for Windows 12.10.5"
}
]
}
},
{
"product_name": "iCloud for Windows",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "iCloud for Windows 10.9.3"
}
]
}
},
{
"product_name": "iCloud for Windows (Legacy)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "iCloud for Windows 7.18"
}
]
}
}
]
},
"vendor_name": "Apple"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A buffer overflow was addressed with improved bounds checking. This issue is fixed in iOS 13.4 and iPadOS 13.4, macOS Catalina 10.15.4, tvOS 13.4, watchOS 6.2, iTunes for Windows 12.10.5, iCloud for Windows 10.9.3, iCloud for Windows 7.18. Multiple issues in libxml2."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple issues in libxml2"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.apple.com/HT211100",
"refsource": "MISC",
"url": "https://support.apple.com/HT211100"
},
{
"name": "https://support.apple.com/HT211102",
"refsource": "MISC",
"url": "https://support.apple.com/HT211102"
},
{
"name": "https://support.apple.com/HT211101",
"refsource": "MISC",
"url": "https://support.apple.com/HT211101"
},
{
"name": "https://support.apple.com/HT211103",
"refsource": "MISC",
"url": "https://support.apple.com/HT211103"
},
{
"name": "https://support.apple.com/HT211105",
"refsource": "MISC",
"url": "https://support.apple.com/HT211105"
},
{
"name": "https://support.apple.com/HT211106",
"refsource": "MISC",
"url": "https://support.apple.com/HT211106"
},
{
"name": "https://support.apple.com/HT211107",
"refsource": "MISC",
"url": "https://support.apple.com/HT211107"
},
{
"name": "https://www.oracle.com/security-alerts/cpuoct2020.html",
"refsource": "MISC",
"url": "https://www.oracle.com/security-alerts/cpuoct2020.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "286789f9-fbc2-4510-9f9a-43facdede74c",
"assignerShortName": "apple",
"cveId": "CVE-2020-3909",
"datePublished": "2020-04-01T17:53:04.000Z",
"dateReserved": "2019-12-18T00:00:00.000Z",
"dateUpdated": "2024-08-04T07:52:20.628Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-10013 (GCVE-0-2017-10013)
Vulnerability from cvelistv5 – Published: 2017-08-08 15:00 – Updated: 2024-10-04 19:13
VLAI
Summary
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H).
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/99833 | vdb-entryx_refsource_BID |
| http://www.oracle.com/technetwork/security-adviso… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Oracle Corporation | Sun ZFS Storage Appliance Kit (AK) Software |
Affected:
AK 2013
|
Date Public
2017-07-18 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T17:25:00.456Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "99833",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/99833"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-10013",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-04T15:39:59.176549Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-04T19:13:24.725Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Sun ZFS Storage Appliance Kit (AK) Software",
"vendor": "Oracle Corporation",
"versions": [
{
"status": "affected",
"version": "AK 2013"
}
]
}
],
"datePublic": "2017-07-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-09T09:57:01.000Z",
"orgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"shortName": "oracle"
},
"references": [
{
"name": "99833",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/99833"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert_us@oracle.com",
"ID": "CVE-2017-10013",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Sun ZFS Storage Appliance Kit (AK) Software",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "AK 2013"
}
]
}
}
]
},
"vendor_name": "Oracle Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK)."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "99833",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/99833"
},
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"assignerShortName": "oracle",
"cveId": "CVE-2017-10013",
"datePublished": "2017-08-08T15:00:00.000Z",
"dateReserved": "2017-06-21T00:00:00.000Z",
"dateUpdated": "2024-10-04T19:13:24.725Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-10016 (GCVE-0-2017-10016)
Vulnerability from cvelistv5 – Published: 2017-08-08 15:00 – Updated: 2024-10-04 19:13
VLAI
Summary
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 7.5 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H).
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/99855 | vdb-entryx_refsource_BID |
| http://www.oracle.com/technetwork/security-adviso… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Oracle Corporation | Sun ZFS Storage Appliance Kit (AK) Software |
Affected:
AK 2013
|
Date Public
2017-07-18 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T17:25:00.567Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "99855",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/99855"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-10016",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-04T15:39:58.016951Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-04T19:13:08.104Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Sun ZFS Storage Appliance Kit (AK) Software",
"vendor": "Oracle Corporation",
"versions": [
{
"status": "affected",
"version": "AK 2013"
}
]
}
],
"datePublic": "2017-07-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 7.5 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-09T09:57:01.000Z",
"orgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"shortName": "oracle"
},
"references": [
{
"name": "99855",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/99855"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert_us@oracle.com",
"ID": "CVE-2017-10016",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Sun ZFS Storage Appliance Kit (AK) Software",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "AK 2013"
}
]
}
}
]
},
"vendor_name": "Oracle Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 7.5 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK)."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "99855",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/99855"
},
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"assignerShortName": "oracle",
"cveId": "CVE-2017-10016",
"datePublished": "2017-08-08T15:00:00.000Z",
"dateReserved": "2017-06-21T00:00:00.000Z",
"dateUpdated": "2024-10-04T19:13:08.104Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-3578 (GCVE-0-2017-3578)
Vulnerability from cvelistv5 – Published: 2017-04-24 19:00 – Updated: 2024-10-04 19:20
VLAI
Summary
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Easily "exploitable" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- Easily "exploitable" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).
Assigner
References
3 references
| URL | Tags |
|---|---|
| http://www.oracle.com/technetwork/security-adviso… | x_refsource_CONFIRM |
| http://www.securitytracker.com/id/1038292 | vdb-entryx_refsource_SECTRACK |
| http://www.securityfocus.com/bid/97810 | vdb-entryx_refsource_BID |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Oracle Corporation | Sun ZFS Storage Appliance Kit (AK) Software |
Affected:
AK 2013
|
Date Public
2017-04-18 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:30:57.994Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"name": "1038292",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038292"
},
{
"name": "97810",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/97810"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-3578",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-04T16:22:07.505492Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-04T19:20:10.767Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Sun ZFS Storage Appliance Kit (AK) Software",
"vendor": "Oracle Corporation",
"versions": [
{
"status": "affected",
"version": "AK 2013"
}
]
}
],
"datePublic": "2017-04-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Easily \"exploitable\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Easily \"exploitable\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK).",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-07-10T09:57:01.000Z",
"orgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"shortName": "oracle"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"name": "1038292",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038292"
},
{
"name": "97810",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/97810"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert_us@oracle.com",
"ID": "CVE-2017-3578",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Sun ZFS Storage Appliance Kit (AK) Software",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "AK 2013"
}
]
}
}
]
},
"vendor_name": "Oracle Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Easily \"exploitable\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Easily \"exploitable\" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK)."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2017-3236618.html"
},
{
"name": "1038292",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1038292"
},
{
"name": "97810",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/97810"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"assignerShortName": "oracle",
"cveId": "CVE-2017-3578",
"datePublished": "2017-04-24T19:00:00.000Z",
"dateReserved": "2016-12-06T00:00:00.000Z",
"dateUpdated": "2024-10-04T19:20:10.767Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}