Search

Find a vulnerability

Search criteria

    12 vulnerabilities found for skybridge_mb-a200_firmware by seiko-sol

    CVE-2023-25184 (GCVE-0-2023-25184)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:38
    VLAI
    Summary
    Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Use of weak credentials
    • CWE-521 - Weak Password Requirements
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200, SkyBridge BASIC MB-A130, and SkySpider MB-R210 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:18:36.052Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 5.3,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25184",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:38:12.856689Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-521",
                    "description": "CWE-521 Weak Password Requirements",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:38:27.351Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200, SkyBridge BASIC MB-A130, and SkySpider MB-R210",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Use of weak credentials",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-25184",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:38:27.351Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23901 (GCVE-0-2023-23901)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:51
    VLAI
    Summary
    Improper following of a certificate's chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Improper following of a certificate's chain of trust
    • CWE-295 - Improper Certificate Validation
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC MB-A130 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:42:27.068Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.8,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23901",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:50:59.945196Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-295",
                    "description": "CWE-295 Improper Certificate Validation",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:51:04.065Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200 and SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper following of a certificate\u0027s chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper following of a certificate\u0027s chain of trust",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-23901",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:51:04.065Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23578 (GCVE-0-2023-23578)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 16:52
    VLAI
    Summary
    Improper access control vulnerability in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier allows a remote unauthenticated attacker to connect to the product's ADB port.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Improper access control
    • CWE-346 - Origin Validation Error
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 Affected: firmware Ver. 01.00.05 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:35:33.394Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23578",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T16:52:26.103518Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-346",
                    "description": "CWE-346 Origin Validation Error",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T16:52:34.243Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 01.00.05 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper access control vulnerability in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier allows a remote unauthenticated attacker to connect to the product\u0027s ADB port."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper access control",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-23578",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T16:52:34.243Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-22441 (GCVE-0-2023-22441)

    Vulnerability from nvd – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:51
    VLAI
    Summary
    Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Missing authentication for critical function
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC MB-A130 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:07:06.550Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.6,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-22441",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:51:52.775799Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-306",
                    "description": "CWE-306 Missing Authentication for Critical Function",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:51:57.223Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200 and SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Missing authentication for critical function",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-22441",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:51:57.223Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-36560 (GCVE-0-2022-36560)

    Vulnerability from nvd – Published: 2022-08-29 22:46 – Updated: 2024-08-03 10:07
    VLAI
    Summary
    Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:07:34.482Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-08-29T22:46:22.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-36560",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e",
                  "refsource": "MISC",
                  "url": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e"
                },
                {
                  "name": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/",
                  "refsource": "MISC",
                  "url": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-36560",
        "datePublished": "2022-08-29T22:46:22.000Z",
        "dateReserved": "2022-07-25T00:00:00.000Z",
        "dateUpdated": "2024-08-03T10:07:34.482Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-36559 (GCVE-0-2022-36559)

    Vulnerability from nvd – Published: 2022-08-29 22:46 – Updated: 2024-08-03 10:07
    VLAI Shadowserver
    Summary
    Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain a command injection vulnerability via the Ping parameter at ping_exec.cgi.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:07:34.470Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain a command injection vulnerability via the Ping parameter at ping_exec.cgi."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-08-29T22:46:21.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-36559",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain a command injection vulnerability via the Ping parameter at ping_exec.cgi."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e",
                  "refsource": "MISC",
                  "url": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e"
                },
                {
                  "name": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/",
                  "refsource": "MISC",
                  "url": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-36559",
        "datePublished": "2022-08-29T22:46:21.000Z",
        "dateReserved": "2022-07-25T00:00:00.000Z",
        "dateUpdated": "2024-08-03T10:07:34.470Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23901 (GCVE-0-2023-23901)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:51
    VLAI
    Summary
    Improper following of a certificate's chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Improper following of a certificate's chain of trust
    • CWE-295 - Improper Certificate Validation
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC MB-A130 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:42:27.068Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.8,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23901",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:50:59.945196Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-295",
                    "description": "CWE-295 Improper Certificate Validation",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:51:04.065Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200 and SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper following of a certificate\u0027s chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper following of a certificate\u0027s chain of trust",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-23901",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:51:04.065Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-25184 (GCVE-0-2023-25184)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:38
    VLAI
    Summary
    Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Use of weak credentials
    • CWE-521 - Weak Password Requirements
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200, SkyBridge BASIC MB-A130, and SkySpider MB-R210 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T11:18:36.052Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 5.3,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-25184",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:38:12.856689Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-521",
                    "description": "CWE-521 Weak Password Requirements",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:38:27.351Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200, SkyBridge BASIC MB-A130, and SkySpider MB-R210",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Use of weak credentials",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-25184",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:38:27.351Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23578 (GCVE-0-2023-23578)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 16:52
    VLAI
    Summary
    Improper access control vulnerability in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier allows a remote unauthenticated attacker to connect to the product's ADB port.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Improper access control
    • CWE-346 - Origin Validation Error
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 Affected: firmware Ver. 01.00.05 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:35:33.394Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23578",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T16:52:26.103518Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-346",
                    "description": "CWE-346 Origin Validation Error",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T16:52:34.243Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "firmware Ver. 01.00.05 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper access control vulnerability in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier allows a remote unauthenticated attacker to connect to the product\u0027s ADB port."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper access control",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-23578",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T16:52:34.243Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-22441 (GCVE-0-2023-22441)

    Vulnerability from cvelistv5 – Published: 2023-05-10 00:00 – Updated: 2025-01-28 14:51
    VLAI
    Summary
    Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Missing authentication for critical function
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    Seiko Solutions Inc. SkyBridge MB-A200 and SkyBridge BASIC MB-A130 Affected: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:07:06.550Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/archives/73969/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN40604023/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.6,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-22441",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-28T14:51:52.775799Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-306",
                    "description": "CWE-306 Missing Authentication for Critical Function",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-28T14:51:57.223Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SkyBridge MB-A200 and SkyBridge BASIC MB-A130",
              "vendor": "Seiko Solutions Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Missing authentication for critical function",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T00:00:00.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.seiko-sol.co.jp/archives/73969/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a100/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a200/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skybridge/skybridge_download/mb-a130/"
            },
            {
              "url": "https://www.seiko-sol.co.jp/products/skyspider/skyspider_download/mb-r210/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN40604023/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2023-22441",
        "datePublished": "2023-05-10T00:00:00.000Z",
        "dateReserved": "2023-03-15T00:00:00.000Z",
        "dateUpdated": "2025-01-28T14:51:57.223Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-36560 (GCVE-0-2022-36560)

    Vulnerability from cvelistv5 – Published: 2022-08-29 22:46 – Updated: 2024-08-03 10:07
    VLAI
    Summary
    Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:07:34.482Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-08-29T22:46:22.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-36560",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e",
                  "refsource": "MISC",
                  "url": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e"
                },
                {
                  "name": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/",
                  "refsource": "MISC",
                  "url": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-36560",
        "datePublished": "2022-08-29T22:46:22.000Z",
        "dateReserved": "2022-07-25T00:00:00.000Z",
        "dateUpdated": "2024-08-03T10:07:34.482Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-36559 (GCVE-0-2022-36559)

    Vulnerability from cvelistv5 – Published: 2022-08-29 22:46 – Updated: 2024-08-03 10:07
    VLAI Shadowserver
    Summary
    Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain a command injection vulnerability via the Ping parameter at ping_exec.cgi.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:07:34.470Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain a command injection vulnerability via the Ping parameter at ping_exec.cgi."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-08-29T22:46:21.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-36559",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain a command injection vulnerability via the Ping parameter at ping_exec.cgi."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e",
                  "refsource": "MISC",
                  "url": "https://gist.github.com/Nwqda/0db1fc6cfa39d7f0592d44e18c40146e"
                },
                {
                  "name": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/",
                  "refsource": "MISC",
                  "url": "https://www.seiko-sol.co.jp/products/skybridge/lineup/mb-a200/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-36559",
        "datePublished": "2022-08-29T22:46:21.000Z",
        "dateReserved": "2022-07-25T00:00:00.000Z",
        "dateUpdated": "2024-08-03T10:07:34.470Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }