Search criteria

18 vulnerabilities found for scadapro_server by measuresoft

CVE-2024-3746 (GCVE-0-2024-3746)

Vulnerability from nvd – Published: 2024-04-30 19:45 – Updated: 2025-08-27 21:23
VLAI?
Title
Measuresoft ScadaPro Improper Access Control
Summary
The entire parent directory - C:\ScadaPro and its sub-directories and files are configured by default to allow user, including unprivileged users, to write or overwrite files.
CWE
Assigner
Impacted products
Vendor Product Version
Measuresoft ScadaPro Affected: 6.9.0.0
Create a notification for this product.
Credits
Sharon Brizinov of Claroty Team82 reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 7.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-3746",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-03T19:21:37.188099Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T21:23:00.955Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:20:01.065Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ScadaPro",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "6.9.0.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Sharon Brizinov of Claroty Team82 reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The entire parent directory - C:\\ScadaPro and its sub-directories and \nfiles are configured by default to allow user, including unprivileged \nusers, to write or overwrite files."
            }
          ],
          "value": "The entire parent directory - C:\\ScadaPro and its sub-directories and \nfiles are configured by default to allow user, including unprivileged \nusers, to write or overwrite files."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-28T16:38:27.985Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-01"
        }
      ],
      "source": {
        "advisory": "ICSA-24-107-01",
        "discovery": "EXTERNAL"
      },
      "title": "Measuresoft ScadaPro Improper Access Control",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Measuresoft recommends that users manually reconfigure the vulnerable directories so that they are not writable by everyone.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Measuresoft recommends that users manually reconfigure the vulnerable directories so that they are not writable by everyone."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-3746",
    "datePublished": "2024-04-30T19:45:21.951Z",
    "dateReserved": "2024-04-12T20:04:14.046Z",
    "dateUpdated": "2025-08-27T21:23:00.955Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-3263 (GCVE-0-2022-3263)

Vulnerability from nvd – Published: 2022-09-23 18:30 – Updated: 2025-04-16 17:47
VLAI?
Title
Measuresoft ScadaPro Server Improper Access Control
Summary
The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Credits
@rgod777, working with Trend Micro Zero Day Initiative, reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:07:05.988Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-265-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3263",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:10.852779Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:47:16.118Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "6.7"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "@rgod777, working with Trend Micro Zero Day Initiative, reported this vulnerability to CISA."
        }
      ],
      "datePublic": "2022-09-22T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-23T18:30:36.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-265-01"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Measuresoft ScadaPro Server Improper Access Control",
      "workarounds": [
        {
          "lang": "en",
          "value": "Measuresoft recommends the following steps to remove full access to the ORCHESTRATOR service:\n1. Open a command-line window (CMD) with \u0027run as administrator\u0027\n2. Use the following command to make the permission change to the ORCHESTRATOR service: sc sdset ORCHESTRATOR D:(A;;CCLCSWRPWPDTLOCRRC;;;SY)(A;;CCDCLCSWRPWPDTLOCRSDRCWDWO;;;BA)(A;;CCLCSWLOCRRC;;;IU)(A;;CCLCSWLOCRRC;;;SU)\n3. As a low-level user, attempt to shut down the ORCHESTRATOR service: sc stop ORCHESTRATOR. User will be denied. It will no longer be possible to edit the configuration of the service by a low-level user."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-09-22T20:45:00.000Z",
          "ID": "CVE-2022-3263",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server Improper Access Control"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "6.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "@rgod777, working with Trend Micro Zero Day Initiative, reported this vulnerability to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-265-01",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-265-01"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Measuresoft recommends the following steps to remove full access to the ORCHESTRATOR service:\n1. Open a command-line window (CMD) with \u0027run as administrator\u0027\n2. Use the following command to make the permission change to the ORCHESTRATOR service: sc sdset ORCHESTRATOR D:(A;;CCLCSWRPWPDTLOCRRC;;;SY)(A;;CCDCLCSWRPWPDTLOCRSDRCWDWO;;;BA)(A;;CCLCSWLOCRRC;;;IU)(A;;CCLCSWLOCRRC;;;SU)\n3. As a low-level user, attempt to shut down the ORCHESTRATOR service: sc stop ORCHESTRATOR. User will be denied. It will no longer be possible to edit the configuration of the service by a low-level user."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-3263",
    "datePublished": "2022-09-23T18:30:36.700Z",
    "dateReserved": "2022-09-21T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:47:16.118Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2898 (GCVE-0-2022-2898)

Vulnerability from nvd – Published: 2022-08-31 20:54 – Updated: 2025-04-16 16:10
VLAI?
Title
Measuresoft ScadaPro Server and Client Link Following
Summary
Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow a denial-of-service condition.
CWE
  • CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:59.859Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2898",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:50:09.511855Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:10:51.543Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server and Client",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow a denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-59",
              "description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:54:55.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Measuresoft ScadaPro Server and Client Link Following",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
          "ID": "CVE-2022-2898",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server and Client Link Following"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server and Client",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow a denial-of-service condition."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2898",
    "datePublished": "2022-08-31T20:54:55.611Z",
    "dateReserved": "2022-08-18T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:10:51.543Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2897 (GCVE-0-2022-2897)

Vulnerability from nvd – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Title
Measuresoft ScadaPro Server and Client Link Following
Summary
Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow privilege escalation..
CWE
  • CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:59.807Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2897",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:28.086217Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:48:20.720Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server and Client",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow privilege escalation.."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-59",
              "description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:54:55.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Measuresoft ScadaPro Server and Client Link Following",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
          "ID": "CVE-2022-2897",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server and Client Link Following"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server and Client",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow privilege escalation.."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2897",
    "datePublished": "2022-08-31T20:54:55.020Z",
    "dateReserved": "2022-08-18T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:48:20.720Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2896 (GCVE-0-2022-2896)

Vulnerability from nvd – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Title
Measuresoft ScadaPro Server Use After Free
Summary
Measuresoft ScadaPro Server (All Versions) allows use after free while processing a specific project file.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Measuresoft ScadaPro Server Affected: All Versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:59.889Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2896",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:22.611560Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:48:01.170Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Measuresoft ScadaPro Server (All Versions) allows use after free while processing a specific project file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:54:55.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Measuresoft ScadaPro Server Use After Free",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
          "ID": "CVE-2022-2896",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server Use After Free"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Measuresoft ScadaPro Server (All Versions) allows use after free while processing a specific project file."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2896",
    "datePublished": "2022-08-31T20:54:55.401Z",
    "dateReserved": "2022-08-18T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:48:01.170Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2895 (GCVE-0-2022-2895)

Vulnerability from nvd – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Title
Measuresoft ScadaPro Server Stack-based Buffer Overflow
Summary
Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. These controls may allow two stack-based buffer overflow instances while processing a specific project file.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Measuresoft ScadaPro Server Affected: All Versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:53:00.462Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2895",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:31.880992Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:48:31.475Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. These controls may allow two stack-based buffer overflow instances while processing a specific project file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:54:54.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Measuresoft ScadaPro Server Stack-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
          "ID": "CVE-2022-2895",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server Stack-based Buffer Overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. These controls may allow two stack-based buffer overflow instances while processing a specific project file."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2895",
    "datePublished": "2022-08-31T20:54:54.819Z",
    "dateReserved": "2022-08-18T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:48:31.475Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2894 (GCVE-0-2022-2894)

Vulnerability from nvd – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Title
Measuresoft ScadaPro Server Untrusted Pointer Dereference
Summary
Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. The controls may allow seven untrusted pointer deference instances while processing a specific project file.
CWE
  • CWE-822 - Untrusted Pointer Dereference
Assigner
References
Impacted products
Vendor Product Version
Measuresoft ScadaPro Server Affected: All Versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:59.982Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2894",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:25.266972Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:48:12.800Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. The controls may allow seven untrusted pointer deference instances while processing a specific project file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "CWE-822 Untrusted Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:54:55.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Measuresoft ScadaPro Server Untrusted Pointer Dereference",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
          "ID": "CVE-2022-2894",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server Untrusted Pointer Dereference"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. The controls may allow seven untrusted pointer deference instances while processing a specific project file."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-822 Untrusted Pointer Dereference"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2894",
    "datePublished": "2022-08-31T20:54:55.197Z",
    "dateReserved": "2022-08-18T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:48:12.800Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2892 (GCVE-0-2022-2892)

Vulnerability from nvd – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Title
Measuresoft ScadaPro Server Out-of-bounds Write
Summary
Measuresoft ScadaPro Server (Versions prior to 6.8.0.1) uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file.
CWE
Assigner
References
Impacted products
Vendor Product Version
Measuresoft ScadaPro Server Affected: All , < 6.8.0.1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:59.497Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-05"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2892",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:34.723614Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:48:40.246Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server",
          "vendor": "Measuresoft",
          "versions": [
            {
              "lessThan": "6.8.0.1",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Measuresoft ScadaPro Server (Versions prior to 6.8.0.1) uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:54:54.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Measuresoft ScadaPro Server Out-of-bounds Write",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
          "ID": "CVE-2022-2892",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server Out-of-bounds Write"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "6.8.0.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Measuresoft ScadaPro Server (Versions prior to 6.8.0.1) uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787 Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-05",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-05"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2892",
    "datePublished": "2022-08-31T20:54:54.536Z",
    "dateReserved": "2022-08-18T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:48:40.246Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-1824 (GCVE-0-2012-1824)

Vulnerability from nvd – Published: 2012-05-25 19:00 – Updated: 2024-09-16 19:19
VLAI?
Summary
Untrusted search path vulnerability in Measuresoft ScadaPro Client before 4.0.0 and ScadaPro Server before 4.0.0 allows local users to gain privileges via a Trojan horse DLL in the current working directory.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:08:38.554Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Client/DOCUMENTATION/ReleaseNotes.doc"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-145-01.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Server/DOCUMENTATION/ReleaseNotes.doc"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Untrusted search path vulnerability in Measuresoft ScadaPro Client before 4.0.0 and ScadaPro Server before 4.0.0 allows local users to gain privileges via a Trojan horse DLL in the current working directory."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-05-25T19:00:00Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Client/DOCUMENTATION/ReleaseNotes.doc"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-145-01.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Server/DOCUMENTATION/ReleaseNotes.doc"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2012-1824",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Untrusted search path vulnerability in Measuresoft ScadaPro Client before 4.0.0 and ScadaPro Server before 4.0.0 allows local users to gain privileges via a Trojan horse DLL in the current working directory."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Client/DOCUMENTATION/ReleaseNotes.doc",
              "refsource": "MISC",
              "url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Client/DOCUMENTATION/ReleaseNotes.doc"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-145-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-145-01.pdf"
            },
            {
              "name": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Server/DOCUMENTATION/ReleaseNotes.doc",
              "refsource": "MISC",
              "url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Server/DOCUMENTATION/ReleaseNotes.doc"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2012-1824",
    "datePublished": "2012-05-25T19:00:00Z",
    "dateReserved": "2012-03-21T00:00:00Z",
    "dateUpdated": "2024-09-16T19:19:14.083Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-3746 (GCVE-0-2024-3746)

Vulnerability from cvelistv5 – Published: 2024-04-30 19:45 – Updated: 2025-08-27 21:23
VLAI?
Title
Measuresoft ScadaPro Improper Access Control
Summary
The entire parent directory - C:\ScadaPro and its sub-directories and files are configured by default to allow user, including unprivileged users, to write or overwrite files.
CWE
Assigner
Impacted products
Vendor Product Version
Measuresoft ScadaPro Affected: 6.9.0.0
Create a notification for this product.
Credits
Sharon Brizinov of Claroty Team82 reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 7.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-3746",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-03T19:21:37.188099Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T21:23:00.955Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:20:01.065Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ScadaPro",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "6.9.0.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Sharon Brizinov of Claroty Team82 reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The entire parent directory - C:\\ScadaPro and its sub-directories and \nfiles are configured by default to allow user, including unprivileged \nusers, to write or overwrite files."
            }
          ],
          "value": "The entire parent directory - C:\\ScadaPro and its sub-directories and \nfiles are configured by default to allow user, including unprivileged \nusers, to write or overwrite files."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-28T16:38:27.985Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-01"
        }
      ],
      "source": {
        "advisory": "ICSA-24-107-01",
        "discovery": "EXTERNAL"
      },
      "title": "Measuresoft ScadaPro Improper Access Control",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Measuresoft recommends that users manually reconfigure the vulnerable directories so that they are not writable by everyone.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Measuresoft recommends that users manually reconfigure the vulnerable directories so that they are not writable by everyone."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-3746",
    "datePublished": "2024-04-30T19:45:21.951Z",
    "dateReserved": "2024-04-12T20:04:14.046Z",
    "dateUpdated": "2025-08-27T21:23:00.955Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-3263 (GCVE-0-2022-3263)

Vulnerability from cvelistv5 – Published: 2022-09-23 18:30 – Updated: 2025-04-16 17:47
VLAI?
Title
Measuresoft ScadaPro Server Improper Access Control
Summary
The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Credits
@rgod777, working with Trend Micro Zero Day Initiative, reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:07:05.988Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-265-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3263",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:10.852779Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:47:16.118Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "6.7"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "@rgod777, working with Trend Micro Zero Day Initiative, reported this vulnerability to CISA."
        }
      ],
      "datePublic": "2022-09-22T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-23T18:30:36.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-265-01"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Measuresoft ScadaPro Server Improper Access Control",
      "workarounds": [
        {
          "lang": "en",
          "value": "Measuresoft recommends the following steps to remove full access to the ORCHESTRATOR service:\n1. Open a command-line window (CMD) with \u0027run as administrator\u0027\n2. Use the following command to make the permission change to the ORCHESTRATOR service: sc sdset ORCHESTRATOR D:(A;;CCLCSWRPWPDTLOCRRC;;;SY)(A;;CCDCLCSWRPWPDTLOCRSDRCWDWO;;;BA)(A;;CCLCSWLOCRRC;;;IU)(A;;CCLCSWLOCRRC;;;SU)\n3. As a low-level user, attempt to shut down the ORCHESTRATOR service: sc stop ORCHESTRATOR. User will be denied. It will no longer be possible to edit the configuration of the service by a low-level user."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-09-22T20:45:00.000Z",
          "ID": "CVE-2022-3263",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server Improper Access Control"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "6.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "@rgod777, working with Trend Micro Zero Day Initiative, reported this vulnerability to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-265-01",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-265-01"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Measuresoft recommends the following steps to remove full access to the ORCHESTRATOR service:\n1. Open a command-line window (CMD) with \u0027run as administrator\u0027\n2. Use the following command to make the permission change to the ORCHESTRATOR service: sc sdset ORCHESTRATOR D:(A;;CCLCSWRPWPDTLOCRRC;;;SY)(A;;CCDCLCSWRPWPDTLOCRSDRCWDWO;;;BA)(A;;CCLCSWLOCRRC;;;IU)(A;;CCLCSWLOCRRC;;;SU)\n3. As a low-level user, attempt to shut down the ORCHESTRATOR service: sc stop ORCHESTRATOR. User will be denied. It will no longer be possible to edit the configuration of the service by a low-level user."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-3263",
    "datePublished": "2022-09-23T18:30:36.700Z",
    "dateReserved": "2022-09-21T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:47:16.118Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2898 (GCVE-0-2022-2898)

Vulnerability from cvelistv5 – Published: 2022-08-31 20:54 – Updated: 2025-04-16 16:10
VLAI?
Title
Measuresoft ScadaPro Server and Client Link Following
Summary
Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow a denial-of-service condition.
CWE
  • CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:59.859Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2898",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:50:09.511855Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:10:51.543Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server and Client",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow a denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-59",
              "description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:54:55.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Measuresoft ScadaPro Server and Client Link Following",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
          "ID": "CVE-2022-2898",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server and Client Link Following"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server and Client",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow a denial-of-service condition."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2898",
    "datePublished": "2022-08-31T20:54:55.611Z",
    "dateReserved": "2022-08-18T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:10:51.543Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2896 (GCVE-0-2022-2896)

Vulnerability from cvelistv5 – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Title
Measuresoft ScadaPro Server Use After Free
Summary
Measuresoft ScadaPro Server (All Versions) allows use after free while processing a specific project file.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Measuresoft ScadaPro Server Affected: All Versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:59.889Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2896",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:22.611560Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:48:01.170Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Measuresoft ScadaPro Server (All Versions) allows use after free while processing a specific project file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:54:55.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Measuresoft ScadaPro Server Use After Free",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
          "ID": "CVE-2022-2896",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server Use After Free"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Measuresoft ScadaPro Server (All Versions) allows use after free while processing a specific project file."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2896",
    "datePublished": "2022-08-31T20:54:55.401Z",
    "dateReserved": "2022-08-18T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:48:01.170Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2894 (GCVE-0-2022-2894)

Vulnerability from cvelistv5 – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Title
Measuresoft ScadaPro Server Untrusted Pointer Dereference
Summary
Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. The controls may allow seven untrusted pointer deference instances while processing a specific project file.
CWE
  • CWE-822 - Untrusted Pointer Dereference
Assigner
References
Impacted products
Vendor Product Version
Measuresoft ScadaPro Server Affected: All Versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:59.982Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2894",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:25.266972Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:48:12.800Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. The controls may allow seven untrusted pointer deference instances while processing a specific project file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "CWE-822 Untrusted Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:54:55.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Measuresoft ScadaPro Server Untrusted Pointer Dereference",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
          "ID": "CVE-2022-2894",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server Untrusted Pointer Dereference"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. The controls may allow seven untrusted pointer deference instances while processing a specific project file."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-822 Untrusted Pointer Dereference"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2894",
    "datePublished": "2022-08-31T20:54:55.197Z",
    "dateReserved": "2022-08-18T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:48:12.800Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2897 (GCVE-0-2022-2897)

Vulnerability from cvelistv5 – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Title
Measuresoft ScadaPro Server and Client Link Following
Summary
Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow privilege escalation..
CWE
  • CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:59.807Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2897",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:28.086217Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:48:20.720Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server and Client",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow privilege escalation.."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-59",
              "description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:54:55.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Measuresoft ScadaPro Server and Client Link Following",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
          "ID": "CVE-2022-2897",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server and Client Link Following"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server and Client",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow privilege escalation.."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2897",
    "datePublished": "2022-08-31T20:54:55.020Z",
    "dateReserved": "2022-08-18T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:48:20.720Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2895 (GCVE-0-2022-2895)

Vulnerability from cvelistv5 – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Title
Measuresoft ScadaPro Server Stack-based Buffer Overflow
Summary
Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. These controls may allow two stack-based buffer overflow instances while processing a specific project file.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Measuresoft ScadaPro Server Affected: All Versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:53:00.462Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2895",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:31.880992Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:48:31.475Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server",
          "vendor": "Measuresoft",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. These controls may allow two stack-based buffer overflow instances while processing a specific project file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:54:54.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Measuresoft ScadaPro Server Stack-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
          "ID": "CVE-2022-2895",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server Stack-based Buffer Overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. These controls may allow two stack-based buffer overflow instances while processing a specific project file."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121 Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2895",
    "datePublished": "2022-08-31T20:54:54.819Z",
    "dateReserved": "2022-08-18T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:48:31.475Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2892 (GCVE-0-2022-2892)

Vulnerability from cvelistv5 – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Title
Measuresoft ScadaPro Server Out-of-bounds Write
Summary
Measuresoft ScadaPro Server (Versions prior to 6.8.0.1) uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file.
CWE
Assigner
References
Impacted products
Vendor Product Version
Measuresoft ScadaPro Server Affected: All , < 6.8.0.1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:59.497Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-05"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2892",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:34.723614Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:48:40.246Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ScadaPro Server",
          "vendor": "Measuresoft",
          "versions": [
            {
              "lessThan": "6.8.0.1",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Measuresoft ScadaPro Server (Versions prior to 6.8.0.1) uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:54:54.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Measuresoft ScadaPro Server Out-of-bounds Write",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
          "ID": "CVE-2022-2892",
          "STATE": "PUBLIC",
          "TITLE": "Measuresoft ScadaPro Server Out-of-bounds Write"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ScadaPro Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "6.8.0.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Measuresoft"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Measuresoft ScadaPro Server (Versions prior to 6.8.0.1) uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787 Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-05",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-05"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2892",
    "datePublished": "2022-08-31T20:54:54.536Z",
    "dateReserved": "2022-08-18T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:48:40.246Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-1824 (GCVE-0-2012-1824)

Vulnerability from cvelistv5 – Published: 2012-05-25 19:00 – Updated: 2024-09-16 19:19
VLAI?
Summary
Untrusted search path vulnerability in Measuresoft ScadaPro Client before 4.0.0 and ScadaPro Server before 4.0.0 allows local users to gain privileges via a Trojan horse DLL in the current working directory.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:08:38.554Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Client/DOCUMENTATION/ReleaseNotes.doc"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-145-01.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Server/DOCUMENTATION/ReleaseNotes.doc"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Untrusted search path vulnerability in Measuresoft ScadaPro Client before 4.0.0 and ScadaPro Server before 4.0.0 allows local users to gain privileges via a Trojan horse DLL in the current working directory."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-05-25T19:00:00Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Client/DOCUMENTATION/ReleaseNotes.doc"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-145-01.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Server/DOCUMENTATION/ReleaseNotes.doc"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2012-1824",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Untrusted search path vulnerability in Measuresoft ScadaPro Client before 4.0.0 and ScadaPro Server before 4.0.0 allows local users to gain privileges via a Trojan horse DLL in the current working directory."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Client/DOCUMENTATION/ReleaseNotes.doc",
              "refsource": "MISC",
              "url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Client/DOCUMENTATION/ReleaseNotes.doc"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-145-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-145-01.pdf"
            },
            {
              "name": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Server/DOCUMENTATION/ReleaseNotes.doc",
              "refsource": "MISC",
              "url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Server/DOCUMENTATION/ReleaseNotes.doc"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2012-1824",
    "datePublished": "2012-05-25T19:00:00Z",
    "dateReserved": "2012-03-21T00:00:00Z",
    "dateUpdated": "2024-09-16T19:19:14.083Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}