Search criteria

6 vulnerabilities found for rsnetworx by rockwellautomation

VAR-202005-0313

Vulnerability from variot - Updated: 2024-11-23 21:59

Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions. Rockwell Automation Provided by the company EDS Subsystem The following multiple vulnerabilities exist in. * SQL injection (CWE-89) - CVE-2020-12034 * Buffer error (CWE-199) - CVE-2020-12038The expected impact depends on each vulnerability, but it may be affected as follows. * Crafted by a third party on an adjacent network EDS Illegal by reading a file SQL Statement is executed and service operation is interrupted (DoS) Attack is triggered - CVE-2020-12034 * Crafted by a local third party EDS Memory corruption occurs by reading the file, which interferes with service operation. (DoS) Attack is triggered - CVE-2020-12038. An attacker can exploit this vulnerability with a specially crafted EDS file to cause a denial of service

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0313",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "eds subsystem",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "28.0.1"
      },
      {
        "model": "rslinx enterprise",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "6.00.00"
      },
      {
        "model": "rslinx enterprise",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "6.11.00"
      },
      {
        "model": "rsnetworx",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "28.00.00"
      },
      {
        "model": "studio 5000 logix designer",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "32.0"
      },
      {
        "model": "rslinx",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "4.11.00"
      },
      {
        "model": "rslinx enterprise",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "6.10.00"
      },
      {
        "model": "factorytalk",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": "linx software (\u65e7\u79f0 rslinx enterprise) version 6.00\u3001 6.10 \u304a\u3088\u3073 6.11"
      },
      {
        "model": "rslinx classic",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": "version 4.11.00"
      },
      {
        "model": "rsnetworx",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": "software version 28.00.00"
      },
      {
        "model": "studio 5000 logix designer",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": "software version 32"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12034"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:rockwellautomation:factorytalk",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:rockwellautomation:rslinx_classic",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:rockwellautomation:rsnetworx",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:rockwellautomation:studio_5000_logix_designer",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      }
    ]
  },
  "cve": "CVE-2020-12034",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CVE-2020-12034",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.1,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "VHN-164672",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:N/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2020-12034",
            "impactScore": 4.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "IPA score",
            "availabilityImpact": "High",
            "baseScore": 8.2,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-004590",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "None",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "IPA score",
            "availabilityImpact": "High",
            "baseScore": 6.7,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-004590",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "Low",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:L/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-12034",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "IPA",
            "id": "JVNDB-2020-004590",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "IPA",
            "id": "JVNDB-2020-004590",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-935",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-164672",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-12034",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-164672"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-12034"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-935"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12034"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions. Rockwell Automation Provided by the company EDS Subsystem The following multiple vulnerabilities exist in. * SQL injection (CWE-89) - CVE-2020-12034 * Buffer error (CWE-199) - CVE-2020-12038The expected impact depends on each vulnerability, but it may be affected as follows. * Crafted by a third party on an adjacent network EDS Illegal by reading a file SQL Statement is executed and service operation is interrupted (DoS) Attack is triggered - CVE-2020-12034 * Crafted by a local third party EDS Memory corruption occurs by reading the file, which interferes with service operation. (DoS) Attack is triggered - CVE-2020-12038. An attacker can exploit this vulnerability with a specially crafted EDS file to cause a denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-12034"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "VULHUB",
        "id": "VHN-164672"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-12034"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "ICS CERT",
        "id": "ICSA-20-140-01",
        "trust": 2.6
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12034",
        "trust": 2.6
      },
      {
        "db": "JVN",
        "id": "JVNVU92757733",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-935",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-164672",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-12034",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-164672"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-12034"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-935"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12034"
      }
    ]
  },
  "id": "VAR-202005-0313",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-164672"
      }
    ],
    "trust": 0.7666666999999999
  },
  "last_update_date": "2024-11-23T21:59:18.827000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "RAid 1125928 \uff08\u8981\u30ed\u30b0\u30a4\u30f3\uff09",
        "trust": 0.8,
        "url": "https://idp.rockwellautomation.com/adfs/ls/idpinitiatedsignon.aspx?RelayState=RPID%3Drockwellautomation.custhelp.com%26RelayState%3Danswers%2Fanswer_view%2Fa_id%2F1125928"
      },
      {
        "title": "Rockwell Automation EDS Subsystem SQL Repair measures for injecting vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=119473"
      },
      {
        "title": "winafl-powermopt",
        "trust": 0.1,
        "url": "https://github.com/hardik05/winafl-powermopt "
      },
      {
        "title": "WinAFL",
        "trust": 0.1,
        "url": "https://github.com/pranav0408/WinAFL "
      },
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/DanielEbert/winafl "
      },
      {
        "title": "winafl",
        "trust": 0.1,
        "url": "https://github.com/googleprojectzero/winafl "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2020-12034"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-935"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-89",
        "trust": 1.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-164672"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12034"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12038"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12034"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/cert/jvnvu92757733"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-12034"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/89.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/hardik05/winafl-powermopt"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-164672"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-12034"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-935"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12034"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-164672"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-12034"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-935"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12034"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-05-20T00:00:00",
        "db": "VULHUB",
        "id": "VHN-164672"
      },
      {
        "date": "2020-05-20T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-12034"
      },
      {
        "date": "2020-05-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "date": "2020-05-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-935"
      },
      {
        "date": "2020-05-20T03:15:09.960000",
        "db": "NVD",
        "id": "CVE-2020-12034"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-05-22T00:00:00",
        "db": "VULHUB",
        "id": "VHN-164672"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-12034"
      },
      {
        "date": "2020-05-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "date": "2021-01-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-935"
      },
      {
        "date": "2024-11-21T04:59:09.277000",
        "db": "NVD",
        "id": "CVE-2020-12034"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-935"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Rockwell Automation Made  EDS Subsystem Multiple vulnerabilities in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SQL injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-935"
      }
    ],
    "trust": 0.6
  }
}

VAR-202005-0314

Vulnerability from variot - Updated: 2024-11-23 21:59

Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions. Rockwell Automation Provided by the company EDS Subsystem The following multiple vulnerabilities exist in. * SQL injection (CWE-89) - CVE-2020-12034 * Buffer error (CWE-199) - CVE-2020-12038The expected impact depends on each vulnerability, but it may be affected as follows. * Crafted by a third party on an adjacent network EDS Illegal by reading a file SQL Statement is executed and service operation is interrupted (DoS) Attack is triggered - CVE-2020-12034 * Crafted by a local third party EDS Memory corruption occurs by reading the file, which interferes with service operation. (DoS) Attack is triggered - CVE-2020-12038

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0314",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "eds subsystem",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "28.0.1"
      },
      {
        "model": "rslinx enterprise",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "6.00.00"
      },
      {
        "model": "rslinx enterprise",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "6.11.00"
      },
      {
        "model": "rsnetworx",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "28.00.00"
      },
      {
        "model": "studio 5000 logix designer",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "32.0"
      },
      {
        "model": "rslinx",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "4.11.00"
      },
      {
        "model": "rslinx enterprise",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "6.10.00"
      },
      {
        "model": "factorytalk",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": "linx software (\u65e7\u79f0 rslinx enterprise) version 6.00\u3001 6.10 \u304a\u3088\u3073 6.11"
      },
      {
        "model": "rslinx classic",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": "version 4.11.00"
      },
      {
        "model": "rsnetworx",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": "software version 28.00.00"
      },
      {
        "model": "studio 5000 logix designer",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": "software version 32"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12038"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:rockwellautomation:factorytalk",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:rockwellautomation:rslinx_classic",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:rockwellautomation:rsnetworx",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:rockwellautomation:studio_5000_logix_designer",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      }
    ]
  },
  "cve": "CVE-2020-12038",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2020-12038",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.1,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "VHN-164676",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 1.8,
            "id": "CVE-2020-12038",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "IPA score",
            "availabilityImpact": "High",
            "baseScore": 8.2,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-004590",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "None",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "IPA score",
            "availabilityImpact": "High",
            "baseScore": 6.7,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-004590",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "Low",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:L/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-12038",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "IPA",
            "id": "JVNDB-2020-004590",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "IPA",
            "id": "JVNDB-2020-004590",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-942",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-164676",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-12038",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-164676"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-12038"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-942"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12038"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions. Rockwell Automation Provided by the company EDS Subsystem The following multiple vulnerabilities exist in. * SQL injection (CWE-89) - CVE-2020-12034 * Buffer error (CWE-199) - CVE-2020-12038The expected impact depends on each vulnerability, but it may be affected as follows. * Crafted by a third party on an adjacent network EDS Illegal by reading a file SQL Statement is executed and service operation is interrupted (DoS) Attack is triggered - CVE-2020-12034 * Crafted by a local third party EDS Memory corruption occurs by reading the file, which interferes with service operation. (DoS) Attack is triggered - CVE-2020-12038",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-12038"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "VULHUB",
        "id": "VHN-164676"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-12038"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-12038",
        "trust": 2.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-20-140-01",
        "trust": 2.6
      },
      {
        "db": "JVN",
        "id": "JVNVU92757733",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-942",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-164676",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-12038",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-164676"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-12038"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-942"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12038"
      }
    ]
  },
  "id": "VAR-202005-0314",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-164676"
      }
    ],
    "trust": 0.7666666999999999
  },
  "last_update_date": "2024-11-23T21:59:18.798000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "RAid 1125928 \uff08\u8981\u30ed\u30b0\u30a4\u30f3\uff09",
        "trust": 0.8,
        "url": "https://idp.rockwellautomation.com/adfs/ls/idpinitiatedsignon.aspx?RelayState=RPID%3Drockwellautomation.custhelp.com%26RelayState%3Danswers%2Fanswer_view%2Fa_id%2F1125928"
      },
      {
        "title": "Rockwell Automation EDS Subsystem Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=119474"
      },
      {
        "title": "winafl-powermopt",
        "trust": 0.1,
        "url": "https://github.com/hardik05/winafl-powermopt "
      },
      {
        "title": "WinAFL",
        "trust": 0.1,
        "url": "https://github.com/pranav0408/WinAFL "
      },
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/DanielEbert/winafl "
      },
      {
        "title": "winafl",
        "trust": 0.1,
        "url": "https://github.com/googleprojectzero/winafl "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2020-12038"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-942"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-164676"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12038"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12038"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12034"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/cert/jvnvu92757733"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-12038"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/hardik05/winafl-powermopt"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-164676"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-12038"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-942"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12038"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-164676"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-12038"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-942"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-12038"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-05-19T00:00:00",
        "db": "VULHUB",
        "id": "VHN-164676"
      },
      {
        "date": "2020-05-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-12038"
      },
      {
        "date": "2020-05-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "date": "2020-05-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-942"
      },
      {
        "date": "2020-05-19T22:15:12.013000",
        "db": "NVD",
        "id": "CVE-2020-12038"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-09-23T00:00:00",
        "db": "VULHUB",
        "id": "VHN-164676"
      },
      {
        "date": "2021-09-23T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-12038"
      },
      {
        "date": "2020-05-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      },
      {
        "date": "2021-09-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-942"
      },
      {
        "date": "2024-11-21T04:59:09.737000",
        "db": "NVD",
        "id": "CVE-2020-12038"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-942"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Rockwell Automation Made  EDS Subsystem Multiple vulnerabilities in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-004590"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-942"
      }
    ],
    "trust": 0.6
  }
}

CVE-2020-12034 (GCVE-0-2020-12034)

Vulnerability from nvd – Published: 2020-05-20 02:38 – Updated: 2024-08-04 11:48
VLAI?
Summary
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.
Severity ?
No CVSS data available.
CWE
  • CWE-89 - IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND ('SQL INJECTION') CWE-89
Assigner
References
Impacted products
Vendor Product Version
n/a EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software Affected: EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:57.791Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND (\u0027SQL INJECTION\u0027) CWE-89",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-20T02:38:00",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-12034",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND (\u0027SQL INJECTION\u0027) CWE-89"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-12034",
    "datePublished": "2020-05-20T02:38:00",
    "dateReserved": "2020-04-21T00:00:00",
    "dateUpdated": "2024-08-04T11:48:57.791Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12038 (GCVE-0-2020-12038)

Vulnerability from nvd – Published: 2020-05-19 21:36 – Updated: 2024-08-04 11:48
VLAI?
Summary
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions.
Severity ?
No CVSS data available.
CWE
  • CWE-119 - IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119
Assigner
References
Impacted products
Vendor Product Version
n/a EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software Affected: EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:58.157Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-19T21:36:54",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-12038",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-12038",
    "datePublished": "2020-05-19T21:36:54",
    "dateReserved": "2020-04-21T00:00:00",
    "dateUpdated": "2024-08-04T11:48:58.157Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12034 (GCVE-0-2020-12034)

Vulnerability from cvelistv5 – Published: 2020-05-20 02:38 – Updated: 2024-08-04 11:48
VLAI?
Summary
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.
Severity ?
No CVSS data available.
CWE
  • CWE-89 - IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND ('SQL INJECTION') CWE-89
Assigner
References
Impacted products
Vendor Product Version
n/a EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software Affected: EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:57.791Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND (\u0027SQL INJECTION\u0027) CWE-89",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-20T02:38:00",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-12034",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND (\u0027SQL INJECTION\u0027) CWE-89"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-12034",
    "datePublished": "2020-05-20T02:38:00",
    "dateReserved": "2020-04-21T00:00:00",
    "dateUpdated": "2024-08-04T11:48:57.791Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12038 (GCVE-0-2020-12038)

Vulnerability from cvelistv5 – Published: 2020-05-19 21:36 – Updated: 2024-08-04 11:48
VLAI?
Summary
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions.
Severity ?
No CVSS data available.
CWE
  • CWE-119 - IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119
Assigner
References
Impacted products
Vendor Product Version
n/a EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software Affected: EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:58.157Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-19T21:36:54",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-12038",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-12038",
    "datePublished": "2020-05-19T21:36:54",
    "dateReserved": "2020-04-21T00:00:00",
    "dateUpdated": "2024-08-04T11:48:58.157Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}