Search criteria

2 vulnerabilities found for qca7005_firmware by qualcomm

CVE-2025-47324 (GCVE-0-2025-47324)

Vulnerability from nvd – Published: 2025-08-06 07:26 – Updated: 2025-08-06 13:28
VLAI?
Title
Exposure of Sensitive Information Through Metadata in Powerline Communication Firmware
Summary
Information disclosure while accessing and modifying the PIB file of a remote device via powerline.
CWE
  • CWE-1230 - Exposure of Sensitive Information Through Metadata
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-47324",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-06T13:28:18.786501Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-06T13:28:25.502Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Snapdragon Auto"
          ],
          "product": "Snapdragon",
          "vendor": "Qualcomm, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "QCA7005"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Information disclosure while accessing and modifying the PIB file of a remote device via powerline."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1230",
              "description": "CWE-1230: Exposure of Sensitive Information Through Metadata",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-06T07:26:12.864Z",
        "orgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
        "shortName": "qualcomm"
      },
      "references": [
        {
          "url": "https://docs.qualcomm.com/product/publicresources/securitybulletin/august-2025-bulletin.html"
        }
      ],
      "title": "Exposure of Sensitive Information Through Metadata in Powerline Communication Firmware"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
    "assignerShortName": "qualcomm",
    "cveId": "CVE-2025-47324",
    "datePublished": "2025-08-06T07:26:12.864Z",
    "dateReserved": "2025-05-06T08:33:16.260Z",
    "dateUpdated": "2025-08-06T13:28:25.502Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-47324 (GCVE-0-2025-47324)

Vulnerability from cvelistv5 – Published: 2025-08-06 07:26 – Updated: 2025-08-06 13:28
VLAI?
Title
Exposure of Sensitive Information Through Metadata in Powerline Communication Firmware
Summary
Information disclosure while accessing and modifying the PIB file of a remote device via powerline.
CWE
  • CWE-1230 - Exposure of Sensitive Information Through Metadata
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-47324",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-06T13:28:18.786501Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-06T13:28:25.502Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Snapdragon Auto"
          ],
          "product": "Snapdragon",
          "vendor": "Qualcomm, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "QCA7005"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Information disclosure while accessing and modifying the PIB file of a remote device via powerline."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1230",
              "description": "CWE-1230: Exposure of Sensitive Information Through Metadata",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-06T07:26:12.864Z",
        "orgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
        "shortName": "qualcomm"
      },
      "references": [
        {
          "url": "https://docs.qualcomm.com/product/publicresources/securitybulletin/august-2025-bulletin.html"
        }
      ],
      "title": "Exposure of Sensitive Information Through Metadata in Powerline Communication Firmware"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
    "assignerShortName": "qualcomm",
    "cveId": "CVE-2025-47324",
    "datePublished": "2025-08-06T07:26:12.864Z",
    "dateReserved": "2025-05-06T08:33:16.260Z",
    "dateUpdated": "2025-08-06T13:28:25.502Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}