    CVE-2021-35402 (GCVE-0-2021-35402)

    Vulnerability from nvd – Published: 2026-02-20 00:00 – Updated: 2026-02-23 20:48
    VLAI
    Summary
    PROLiNK PRC2402M 20190909 before 2021-06-13 allows live_api.cgi?page=satellite_list OS command injection via shell metacharacters in the ip parameter (for satellite_status).
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    PROLiNK PRC2402M Affected: 20190909 , < 2021-06-13 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-35402",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T20:47:08.257712Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T20:48:11.839Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "PRC2402M",
              "vendor": "PROLiNK",
              "versions": [
                {
                  "lessThan": "2021-06-13",
                  "status": "affected",
                  "version": "20190909",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "PROLiNK PRC2402M 20190909 before 2021-06-13 allows live_api.cgi?page=satellite_list OS command injection via shell metacharacters in the ip parameter (for satellite_status)."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-20T18:23:31.742Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://starlabs.sg/advisories/21/21-35402/"
            }
          ],
          "x_generator": {
            "engine": "enrichogram 0.0.1"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-35402",
        "datePublished": "2026-02-20T00:00:00.000Z",
        "dateReserved": "2021-06-23T00:00:00.000Z",
        "dateUpdated": "2026-02-23T20:48:11.839Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-35402 (GCVE-0-2021-35402)

    Vulnerability from cvelistv5 – Published: 2026-02-20 00:00 – Updated: 2026-02-23 20:48
    VLAI
    Summary
    PROLiNK PRC2402M 20190909 before 2021-06-13 allows live_api.cgi?page=satellite_list OS command injection via shell metacharacters in the ip parameter (for satellite_status).
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    PROLiNK PRC2402M Affected: 20190909 , < 2021-06-13 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-35402",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T20:47:08.257712Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T20:48:11.839Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "PRC2402M",
              "vendor": "PROLiNK",
              "versions": [
                {
                  "lessThan": "2021-06-13",
                  "status": "affected",
                  "version": "20190909",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "PROLiNK PRC2402M 20190909 before 2021-06-13 allows live_api.cgi?page=satellite_list OS command injection via shell metacharacters in the ip parameter (for satellite_status)."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-20T18:23:31.742Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://starlabs.sg/advisories/21/21-35402/"
            }
          ],
          "x_generator": {
            "engine": "enrichogram 0.0.1"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-35402",
        "datePublished": "2026-02-20T00:00:00.000Z",
        "dateReserved": "2021-06-23T00:00:00.000Z",
        "dateUpdated": "2026-02-23T20:48:11.839Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    VAR-202108-1798

    Vulnerability from variot - Updated: 2024-08-14 15:37

    In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system. ProLink PRC2402M Contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. ProLink PRC2402M is a router of Singapore ProLink company.

    The set_ledonoff function in the adm.cgi binary file of ProLink PRC2402M 1.0.18 and earlier versions has a command injection vulnerability

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202108-1798",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "prc2402m",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "prolink",
            "version": "1.0.18"
          },
          {
            "model": "prc2402m",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "prolink",
            "version": null
          },
          {
            "model": "prc2402m",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "prolink",
            "version": "prc2402m  firmware  1.0.18  and earlier"
          },
          {
            "model": "prc2402m",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "prolink",
            "version": "\u003c=1.0.18"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68448"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009442"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36707"
          }
        ]
      },
      "cve": "CVE-2021-36707",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2021-36707",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2021-68448",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2021-36707",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-36707",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-36707",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-36707",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-68448",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202108-665",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-36707",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68448"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36707"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009442"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-665"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36707"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system. ProLink PRC2402M Contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted  (DoS) It may be put into a state. ProLink PRC2402M is a router of Singapore ProLink company. \n\r\n\r\nThe set_ledonoff function in the adm.cgi binary file of ProLink PRC2402M 1.0.18 and earlier versions has a command injection vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-36707"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009442"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-68448"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36707"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-36707",
            "trust": 3.9
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009442",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-68448",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-665",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36707",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68448"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36707"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009442"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-665"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36707"
          }
        ]
      },
      "id": "VAR-202108-1798",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68448"
          }
        ],
        "trust": 1.2666667
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68448"
          }
        ]
      },
      "last_update_date": "2024-08-14T15:37:58.403000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://prolink2u.com/"
          },
          {
            "title": "Patch for ProLink PRC2402M command injection vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/287536"
          },
          {
            "title": "ProLink PRC2402M Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=159903"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68448"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009442"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-665"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009442"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36707"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#ledonoff-command-injection"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-36707"
          },
          {
            "trust": 0.8,
            "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#sysinit-password-reset"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68448"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36707"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009442"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-665"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36707"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68448"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36707"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009442"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-665"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36707"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-08-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-68448"
          },
          {
            "date": "2021-08-06T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-36707"
          },
          {
            "date": "2022-04-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-009442"
          },
          {
            "date": "2021-08-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202108-665"
          },
          {
            "date": "2021-08-06T14:15:07.877000",
            "db": "NVD",
            "id": "CVE-2021-36707"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-09-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-68448"
          },
          {
            "date": "2021-08-12T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-36707"
          },
          {
            "date": "2022-04-27T03:14:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-009442"
          },
          {
            "date": "2021-08-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202108-665"
          },
          {
            "date": "2021-08-12T23:03:15.557000",
            "db": "NVD",
            "id": "CVE-2021-36707"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-665"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "ProLink PRC2402M command injection vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68448"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-665"
          }
        ],
        "trust": 1.2
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-665"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202108-1796

    Vulnerability from variot - Updated: 2024-08-14 15:33

    In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system. ProLink PRC2402M Contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. ProLink PRC2402M is a router of Singapore ProLink company.

    The set_TR069 function in the adm.cgi binary file of ProLink PRC2402M 1.0.18 and earlier versions has a command injection vulnerability

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202108-1796",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "prc2402m",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "prolink",
            "version": "1.0.18"
          },
          {
            "model": "prc2402m",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "prolink",
            "version": null
          },
          {
            "model": "prc2402m",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "prolink",
            "version": "prc2402m  firmware  1.0.18  and earlier"
          },
          {
            "model": "prc2402m",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "prolink",
            "version": "\u003c=1.0.18"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68446"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009444"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36705"
          }
        ]
      },
      "cve": "CVE-2021-36705",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2021-36705",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2021-68446",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2021-36705",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-36705",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-36705",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-36705",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-68446",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202108-661",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-36705",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68446"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36705"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009444"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-661"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36705"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page parameter value of TR069 contains a trivial command injection where the value of the TR069_local_port parameter is passed directly to system. ProLink PRC2402M Contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted  (DoS) It may be put into a state. ProLink PRC2402M is a router of Singapore ProLink company. \n\r\n\r\nThe set_TR069 function in the adm.cgi binary file of ProLink PRC2402M 1.0.18 and earlier versions has a command injection vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-36705"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009444"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-68446"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36705"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-36705",
            "trust": 3.9
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009444",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-68446",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-661",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36705",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68446"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36705"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009444"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-661"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36705"
          }
        ]
      },
      "id": "VAR-202108-1796",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68446"
          }
        ],
        "trust": 1.2666667
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68446"
          }
        ]
      },
      "last_update_date": "2024-08-14T15:33:04.845000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://prolink2u.com/"
          },
          {
            "title": "Patch for ProLink PRC2402M command injection vulnerability (CNVD-2021-68446)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/287526"
          },
          {
            "title": "ProLink PRC2402M Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=159899"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68446"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009444"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-661"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009444"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36705"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#tr069-command-injection"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-36705"
          },
          {
            "trust": 0.8,
            "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#sysinit-password-reset"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68446"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36705"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009444"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-661"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36705"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68446"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36705"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009444"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-661"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36705"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-08-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-68446"
          },
          {
            "date": "2021-08-06T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-36705"
          },
          {
            "date": "2022-04-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-009444"
          },
          {
            "date": "2021-08-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202108-661"
          },
          {
            "date": "2021-08-06T14:15:07.790000",
            "db": "NVD",
            "id": "CVE-2021-36705"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-09-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-68446"
          },
          {
            "date": "2021-08-12T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-36705"
          },
          {
            "date": "2022-04-27T03:14:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-009444"
          },
          {
            "date": "2021-08-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202108-661"
          },
          {
            "date": "2022-06-28T14:11:45.273000",
            "db": "NVD",
            "id": "CVE-2021-36705"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-661"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "ProLink\u00a0PRC2402M\u00a0 Command injection vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009444"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-661"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202108-1797

    Vulnerability from variot - Updated: 2024-08-14 13:43

    In ProLink PRC2402M V1.0.18 and older, the set_sys_cmd function in the adm.cgi binary, accessible with a page parameter value of sysCMD contains a trivial command injection where the value of the command parameter is passed directly to system. ProLink PRC2402M Contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. ProLink PRC2402M is a router of Singapore ProLink company

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202108-1797",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "prc2402m",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "prolink",
            "version": "1.0.18"
          },
          {
            "model": "prc2402m",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "prolink",
            "version": null
          },
          {
            "model": "prc2402m",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "prolink",
            "version": "prc2402m  firmware  1.0.18  and earlier"
          },
          {
            "model": "prc2402m",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "prolink",
            "version": "\u003c=1.0.18"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68447"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009443"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36706"
          }
        ]
      },
      "cve": "CVE-2021-36706",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2021-36706",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2021-68447",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2021-36706",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-36706",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-36706",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-36706",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-68447",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202108-666",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-36706",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68447"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36706"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009443"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-666"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36706"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In ProLink PRC2402M V1.0.18 and older, the set_sys_cmd function in the adm.cgi binary, accessible with a page parameter value of sysCMD contains a trivial command injection where the value of the command parameter is passed directly to system. ProLink PRC2402M Contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted  (DoS) It may be put into a state. ProLink PRC2402M is a router of Singapore ProLink company",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-36706"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009443"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-68447"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36706"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-36706",
            "trust": 3.9
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009443",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-68447",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-666",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36706",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68447"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36706"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009443"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-666"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36706"
          }
        ]
      },
      "id": "VAR-202108-1797",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68447"
          }
        ],
        "trust": 1.2666667
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68447"
          }
        ]
      },
      "last_update_date": "2024-08-14T13:43:24.977000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://prolink2u.com/"
          },
          {
            "title": "Patch for ProLink PRC2402M command injection vulnerability (CNVD-2021-68447)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/287531"
          },
          {
            "title": "ProLink PRC2402M Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=159904"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68447"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009443"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-666"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009443"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36706"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#syscmd-command-injection"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-36706"
          },
          {
            "trust": 0.8,
            "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#sysinit-password-reset"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68447"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36706"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009443"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-666"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36706"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68447"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36706"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009443"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-666"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36706"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-08-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-68447"
          },
          {
            "date": "2021-08-06T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-36706"
          },
          {
            "date": "2022-04-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-009443"
          },
          {
            "date": "2021-08-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202108-666"
          },
          {
            "date": "2021-08-06T14:15:07.837000",
            "db": "NVD",
            "id": "CVE-2021-36706"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-09-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-68447"
          },
          {
            "date": "2021-08-12T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-36706"
          },
          {
            "date": "2022-04-27T03:14:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-009443"
          },
          {
            "date": "2021-08-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202108-666"
          },
          {
            "date": "2022-06-28T14:11:45.273000",
            "db": "NVD",
            "id": "CVE-2021-36706"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-666"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "ProLink\u00a0PRC2402M\u00a0 Command injection vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009443"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-666"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202108-1799

    Vulnerability from variot - Updated: 2024-08-14 13:23

    In ProLink PRC2402M V1.0.18 and older, the set_sys_init function in the login.cgi binary allows an attacker to reset the password to the administrative interface of the router. ProLink PRC2402M Contains a vulnerability in the password management function.Information may be obtained. ProLink PRC2402M is a router of Singapore ProLink company.

    The set_sys_init function in the login.cgi binary file of ProLink PRC2402M 1.0.18 and earlier versions has an information disclosure vulnerability

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202108-1799",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "prc2402m",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "prolink",
            "version": "1.0.18"
          },
          {
            "model": "prc2402m",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "prolink",
            "version": null
          },
          {
            "model": "prc2402m",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "prolink",
            "version": "prc2402m  firmware  1.0.18  and earlier"
          },
          {
            "model": "prc2402m",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "prolink",
            "version": "\u003c=1.0.18"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68449"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009441"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36708"
          }
        ]
      },
      "cve": "CVE-2021-36708",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2021-36708",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2021-68449",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2021-36708",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-36708",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-36708",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-36708",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-68449",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202108-657",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-36708",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68449"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36708"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009441"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-657"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36708"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In ProLink PRC2402M V1.0.18 and older, the set_sys_init function in the login.cgi binary allows an attacker to reset the password to the administrative interface of the router. ProLink PRC2402M Contains a vulnerability in the password management function.Information may be obtained. ProLink PRC2402M is a router of Singapore ProLink company. \n\r\n\r\nThe set_sys_init function in the login.cgi binary file of ProLink PRC2402M 1.0.18 and earlier versions has an information disclosure vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-36708"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009441"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-68449"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36708"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-36708",
            "trust": 3.9
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009441",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-68449",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-657",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36708",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68449"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36708"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009441"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-657"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36708"
          }
        ]
      },
      "id": "VAR-202108-1799",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68449"
          }
        ],
        "trust": 1.2666667
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68449"
          }
        ]
      },
      "last_update_date": "2024-08-14T13:23:23.896000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://prolink2u.com/"
          },
          {
            "title": "Patch for ProLink PRC2402M Information Disclosure Vulnerability (CVE-2021-36708)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/287541"
          },
          {
            "title": "ProLink PRC2402M Remediation measures for authorization problem vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=159895"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68449"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009441"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-657"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-640",
            "trust": 1.0
          },
          {
            "problemtype": "Weak password recovery mechanism when you forget your password (CWE-640) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009441"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36708"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://www.ayrx.me/prolink-prc2402m-multiple-vulnerabilities/#sysinit-password-reset"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-36708"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/640.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68449"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36708"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009441"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-657"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36708"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-68449"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-36708"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009441"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-657"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-36708"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-08-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-68449"
          },
          {
            "date": "2021-08-06T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-36708"
          },
          {
            "date": "2022-04-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-009441"
          },
          {
            "date": "2021-08-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202108-657"
          },
          {
            "date": "2021-08-06T14:15:07.917000",
            "db": "NVD",
            "id": "CVE-2021-36708"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-09-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-68449"
          },
          {
            "date": "2021-08-12T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-36708"
          },
          {
            "date": "2022-04-27T03:14:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-009441"
          },
          {
            "date": "2021-08-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202108-657"
          },
          {
            "date": "2021-08-12T23:01:52.530000",
            "db": "NVD",
            "id": "CVE-2021-36708"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-657"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "ProLink\u00a0PRC2402M\u00a0 Vulnerability in password management function",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-009441"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "authorization issue",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202108-657"
          }
        ],
        "trust": 0.6
      }
    }