Search criteria
12 vulnerabilities found for poweredge_r630_firmware by dell
CVE-2024-25942 (GCVE-0-2024-25942)
Vulnerability from nvd – Published: 2024-03-19 07:52 – Updated: 2024-08-12 13:53
VLAI?
Summary
Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.
Severity ?
4.4 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.19.0
(semver)
Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) |
Credits
Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.241Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223210/dsa-2024-104-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25942",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-12T13:53:19.426811Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T13:53:37.973Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue."
}
],
"datePublic": "2024-03-18T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"value": "Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "LOW",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-19T07:52:29.228Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223210/dsa-2024-104-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25942",
"datePublished": "2024-03-19T07:52:29.228Z",
"dateReserved": "2024-02-13T05:29:58.481Z",
"dateUpdated": "2024-08-12T13:53:37.973Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22453 (GCVE-0-2024-22453)
Vulnerability from nvd – Published: 2024-03-19 07:42 – Updated: 2024-08-01 22:43
VLAI?
Summary
Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory.
Severity ?
7.2 (High)
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.19.0
(semver)
Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) |
Credits
Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-22453",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-19T14:44:45.916921Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:52:52.907Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:43:34.929Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223209/dsa-2024-105-security-update-for-dell-poweredge-server-bios-for-a-heap-based-buffer-overflow-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue"
}
],
"datePublic": "2024-03-18T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory."
}
],
"value": "Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-19T07:42:27.785Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223209/dsa-2024-105-security-update-for-dell-poweredge-server-bios-for-a-heap-based-buffer-overflow-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-22453",
"datePublished": "2024-03-19T07:42:27.785Z",
"dateReserved": "2024-01-10T15:26:10.251Z",
"dateUpdated": "2024-08-01T22:43:34.929Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0173 (GCVE-0-2024-0173)
Vulnerability from nvd – Published: 2024-03-13 16:52 – Updated: 2024-08-01 17:41
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
Severity ?
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.0.0
(semver)
Affected: N/A , < 1.7.6 (semver) Affected: N/A , < 1.7.2 (semver) Affected: N/A , < 1.2.3 (semver) Affected: N/A , < 1.13.2 (semver) Affected: N/A , < 1.14.1 (semver) Affected: N/A , < 1.9.1 (semver) Affected: N/A , < 2.14.1 (semver) Affected: N/A , < 2.21.2 (semver) Affected: N/A , < 2.21.1 (semver) Affected: N/A , < 2.21.0 (semver) Affected: N/A , < 2.16.0 (semver) Affected: N/A , < 2.19.0 (semver) Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) Affected: N/A , < 2.20.0 (semver) |
Credits
Dell would like to thank codebreaker1337 for reporting this issue.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0173",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-13T20:00:50.556667Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:58:23.919Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:16.066Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform\t",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.2.3",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.16.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0\u202f\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T16:52:21.293Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-0173",
"datePublished": "2024-03-13T16:52:21.293Z",
"dateReserved": "2023-12-14T05:35:37.836Z",
"dateUpdated": "2024-08-01T17:41:16.066Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0154 (GCVE-0-2024-0154)
Vulnerability from nvd – Published: 2024-03-13 16:41 – Updated: 2024-08-01 17:41
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
Severity ?
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.0.0
(semver)
Affected: N/A , < 1.7.6 (semver) Affected: N/A , < 1.7.2 (semver) Affected: N/A , < 1.2.3 (semver) Affected: N/A , < 1.13.2 (semver) Affected: N/A , < 1.14.1 (semver) Affected: N/A , < 1.9.1 (semver) Affected: N/A , < 2.14.1 (semver) Affected: N/A , < 2.21.2 (semver) Affected: N/A , < 2.21.1 (semver) Affected: N/A , < 2.21.0 (semver) Affected: N/A , < 2.16.0 (semver) Affected: N/A , < 2.19.0 (semver) Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) Affected: N/A , < 2.20.0 (semver) |
Credits
Dell would like to thank codebreaker1337 for reporting this issue.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0154",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-13T19:40:48.987776Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:58:45.175Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:16.006Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.2.3",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.16.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0\u202f",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T16:41:09.360Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-0154",
"datePublished": "2024-03-13T16:41:09.360Z",
"dateReserved": "2023-12-14T05:29:25.760Z",
"dateUpdated": "2024-08-01T17:41:16.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0161 (GCVE-0-2024-0161)
Vulnerability from nvd – Published: 2024-03-13 16:04 – Updated: 2024-08-12 13:56
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.
Severity ?
7.2 (High)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 1.1.1
(semver)
Affected: N/A , < 1.13.2 (semver) Affected: N/A , < 1.14.1 (semver) Affected: N/A , < 1.9.1 (semver) Affected: N/A , < 2.21.2 (semver) Affected: N/A , < 2.21.1 (semver) Affected: N/A , < 2.21.0 (semver) Affected: N/A , < 2.19.0 (semver) Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) Affected: N/A , < 2.20.0 (semver) |
Credits
Dell would like to thank codebreaker1337 as well as schur of BUPT, Dubhe Lab for reporting this issue.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:15.986Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222979/dsa-2024-006-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0161",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-12T13:56:13.395413Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T13:56:29.418Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.1.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 as well as schur of BUPT, Dubhe Lab for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T16:04:12.678Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222979/dsa-2024-006-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-0161",
"datePublished": "2024-03-13T16:04:12.678Z",
"dateReserved": "2023-12-14T05:30:39.766Z",
"dateUpdated": "2024-08-12T13:56:29.418Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32460 (GCVE-0-2023-32460)
Vulnerability from nvd – Published: 2023-12-08 05:37 – Updated: 2024-08-02 15:18
VLAI?
Summary
Dell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.
Severity ?
8.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
Versions prior to 1.6.6
Affected: Versions prior to 1.3.6 Affected: Versions prior to 1.1.2 Affected: Versions prior to 1.12.1 Affected: Versions prior to 1.8.1 Affected: Versions prior to 1.13.3 Affected: Versions prior to 2.13.3 Affected: Versions prior to 2.20.1 Affected: Versions prior to 2.20.0 Affected: Versions prior to 2.15.1 Affected: Versions prior to 1.21.0 Affected: Versions prior to 2.18.1 Affected: Versions prior to 2.13.0 Affected: Versions prior to 2.18.2 Affected: Versions prior to 1.18.1 Affected: Versions prior to 2.19.1 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:18:37.251Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000219550/dsa-2023-361-security-update-for-dell-poweredge-server-bios-for-an-improper-privilege-management-security-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"BIOS"
],
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 1.6.6"
},
{
"status": "affected",
"version": "Versions prior to 1.3.6"
},
{
"status": "affected",
"version": "Versions prior to 1.1.2"
},
{
"status": "affected",
"version": "Versions prior to 1.12.1"
},
{
"status": "affected",
"version": "Versions prior to 1.8.1"
},
{
"status": "affected",
"version": "Versions prior to 1.13.3"
},
{
"status": "affected",
"version": "Versions prior to 2.13.3"
},
{
"status": "affected",
"version": "Versions prior to 2.20.1"
},
{
"status": "affected",
"version": "Versions prior to 2.20.0"
},
{
"status": "affected",
"version": "Versions prior to 2.15.1"
},
{
"status": "affected",
"version": "Versions prior to 1.21.0"
},
{
"status": "affected",
"version": "Versions prior to 2.18.1 "
},
{
"status": "affected",
"version": "Versions prior to 2.13.0\u202f "
},
{
"status": "affected",
"version": "Versions prior to 2.18.2 "
},
{
"status": "affected",
"version": "Versions prior to 1.18.1\u202f "
},
{
"status": "affected",
"version": "Versions prior to 2.19.1\u202f "
}
]
}
],
"datePublic": "2023-12-07T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.\u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-08T05:37:52.680Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000219550/dsa-2023-361-security-update-for-dell-poweredge-server-bios-for-an-improper-privilege-management-security-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-32460",
"datePublished": "2023-12-08T05:37:52.680Z",
"dateReserved": "2023-05-09T06:05:24.994Z",
"dateUpdated": "2024-08-02T15:18:37.251Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-25942 (GCVE-0-2024-25942)
Vulnerability from cvelistv5 – Published: 2024-03-19 07:52 – Updated: 2024-08-12 13:53
VLAI?
Summary
Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.
Severity ?
4.4 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.19.0
(semver)
Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) |
Credits
Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.241Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223210/dsa-2024-104-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25942",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-12T13:53:19.426811Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T13:53:37.973Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue."
}
],
"datePublic": "2024-03-18T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"value": "Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "LOW",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-19T07:52:29.228Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223210/dsa-2024-104-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25942",
"datePublished": "2024-03-19T07:52:29.228Z",
"dateReserved": "2024-02-13T05:29:58.481Z",
"dateUpdated": "2024-08-12T13:53:37.973Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22453 (GCVE-0-2024-22453)
Vulnerability from cvelistv5 – Published: 2024-03-19 07:42 – Updated: 2024-08-01 22:43
VLAI?
Summary
Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory.
Severity ?
7.2 (High)
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.19.0
(semver)
Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) |
Credits
Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-22453",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-19T14:44:45.916921Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:52:52.907Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:43:34.929Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223209/dsa-2024-105-security-update-for-dell-poweredge-server-bios-for-a-heap-based-buffer-overflow-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank schur of BUPT, Dubhe Lab for reporting this issue"
}
],
"datePublic": "2024-03-18T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory."
}
],
"value": "Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-19T07:42:27.785Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223209/dsa-2024-105-security-update-for-dell-poweredge-server-bios-for-a-heap-based-buffer-overflow-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-22453",
"datePublished": "2024-03-19T07:42:27.785Z",
"dateReserved": "2024-01-10T15:26:10.251Z",
"dateUpdated": "2024-08-01T22:43:34.929Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0173 (GCVE-0-2024-0173)
Vulnerability from cvelistv5 – Published: 2024-03-13 16:52 – Updated: 2024-08-01 17:41
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
Severity ?
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.0.0
(semver)
Affected: N/A , < 1.7.6 (semver) Affected: N/A , < 1.7.2 (semver) Affected: N/A , < 1.2.3 (semver) Affected: N/A , < 1.13.2 (semver) Affected: N/A , < 1.14.1 (semver) Affected: N/A , < 1.9.1 (semver) Affected: N/A , < 2.14.1 (semver) Affected: N/A , < 2.21.2 (semver) Affected: N/A , < 2.21.1 (semver) Affected: N/A , < 2.21.0 (semver) Affected: N/A , < 2.16.0 (semver) Affected: N/A , < 2.19.0 (semver) Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) Affected: N/A , < 2.20.0 (semver) |
Credits
Dell would like to thank codebreaker1337 for reporting this issue.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0173",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-13T20:00:50.556667Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:58:23.919Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:16.066Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform\t",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.2.3",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.16.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0\u202f\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T16:52:21.293Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-0173",
"datePublished": "2024-03-13T16:52:21.293Z",
"dateReserved": "2023-12-14T05:35:37.836Z",
"dateUpdated": "2024-08-01T17:41:16.066Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0154 (GCVE-0-2024-0154)
Vulnerability from cvelistv5 – Published: 2024-03-13 16:41 – Updated: 2024-08-01 17:41
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory.
Severity ?
CWE
- CWE-788 - Access of Memory Location After End of Buffer
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 2.0.0
(semver)
Affected: N/A , < 1.7.6 (semver) Affected: N/A , < 1.7.2 (semver) Affected: N/A , < 1.2.3 (semver) Affected: N/A , < 1.13.2 (semver) Affected: N/A , < 1.14.1 (semver) Affected: N/A , < 1.9.1 (semver) Affected: N/A , < 2.14.1 (semver) Affected: N/A , < 2.21.2 (semver) Affected: N/A , < 2.21.1 (semver) Affected: N/A , < 2.21.0 (semver) Affected: N/A , < 2.16.0 (semver) Affected: N/A , < 2.19.0 (semver) Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) Affected: N/A , < 2.20.0 (semver) |
Credits
Dell would like to thank codebreaker1337 for reporting this issue.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0154",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-13T19:40:48.987776Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:58:45.175Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:16.006Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.7.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.2.3",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.16.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0\u202f",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. A local low privileged attacker could potentially exploit this vulnerability to read the contents of non-SMM stack memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-788",
"description": "CWE-788: Access of Memory Location After End of Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T16:41:09.360Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222898/dsa-2024-034-security-update-for-dell-poweredge-server-bios-for-an-improper-parameter-initialization-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-0154",
"datePublished": "2024-03-13T16:41:09.360Z",
"dateReserved": "2023-12-14T05:29:25.760Z",
"dateUpdated": "2024-08-01T17:41:16.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0161 (GCVE-0-2024-0161)
Vulnerability from cvelistv5 – Published: 2024-03-13 16:04 – Updated: 2024-08-12 13:56
VLAI?
Summary
Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.
Severity ?
7.2 (High)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
N/A , < 1.1.1
(semver)
Affected: N/A , < 1.13.2 (semver) Affected: N/A , < 1.14.1 (semver) Affected: N/A , < 1.9.1 (semver) Affected: N/A , < 2.21.2 (semver) Affected: N/A , < 2.21.1 (semver) Affected: N/A , < 2.21.0 (semver) Affected: N/A , < 2.19.0 (semver) Affected: N/A , < 2.14.0 (semver) Affected: N/A , < 1.19.0 (semver) Affected: N/A , < 2.20.0 (semver) |
Credits
Dell would like to thank codebreaker1337 as well as schur of BUPT, Dubhe Lab for reporting this issue.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:15.986Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222979/dsa-2024-006-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0161",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-12T13:56:13.395413Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T13:56:29.418Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.1.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.13.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.14.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.9.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.2",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.19.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.14.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.19.0\u00a0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "2.20.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell would like to thank codebreaker1337 as well as schur of BUPT, Dubhe Lab for reporting this issue."
}
],
"datePublic": "2024-03-12T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"value": "Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-13T16:04:12.678Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000222979/dsa-2024-006-security-update-for-dell-poweredge-server-bios-for-an-improper-smm-communication-buffer-verification-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-0161",
"datePublished": "2024-03-13T16:04:12.678Z",
"dateReserved": "2023-12-14T05:30:39.766Z",
"dateUpdated": "2024-08-12T13:56:29.418Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32460 (GCVE-0-2023-32460)
Vulnerability from cvelistv5 – Published: 2023-12-08 05:37 – Updated: 2024-08-02 15:18
VLAI?
Summary
Dell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.
Severity ?
8.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerEdge Platform |
Affected:
Versions prior to 1.6.6
Affected: Versions prior to 1.3.6 Affected: Versions prior to 1.1.2 Affected: Versions prior to 1.12.1 Affected: Versions prior to 1.8.1 Affected: Versions prior to 1.13.3 Affected: Versions prior to 2.13.3 Affected: Versions prior to 2.20.1 Affected: Versions prior to 2.20.0 Affected: Versions prior to 2.15.1 Affected: Versions prior to 1.21.0 Affected: Versions prior to 2.18.1 Affected: Versions prior to 2.13.0 Affected: Versions prior to 2.18.2 Affected: Versions prior to 1.18.1 Affected: Versions prior to 2.19.1 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:18:37.251Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000219550/dsa-2023-361-security-update-for-dell-poweredge-server-bios-for-an-improper-privilege-management-security-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"BIOS"
],
"product": "PowerEdge Platform",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 1.6.6"
},
{
"status": "affected",
"version": "Versions prior to 1.3.6"
},
{
"status": "affected",
"version": "Versions prior to 1.1.2"
},
{
"status": "affected",
"version": "Versions prior to 1.12.1"
},
{
"status": "affected",
"version": "Versions prior to 1.8.1"
},
{
"status": "affected",
"version": "Versions prior to 1.13.3"
},
{
"status": "affected",
"version": "Versions prior to 2.13.3"
},
{
"status": "affected",
"version": "Versions prior to 2.20.1"
},
{
"status": "affected",
"version": "Versions prior to 2.20.0"
},
{
"status": "affected",
"version": "Versions prior to 2.15.1"
},
{
"status": "affected",
"version": "Versions prior to 1.21.0"
},
{
"status": "affected",
"version": "Versions prior to 2.18.1 "
},
{
"status": "affected",
"version": "Versions prior to 2.13.0\u202f "
},
{
"status": "affected",
"version": "Versions prior to 2.18.2 "
},
{
"status": "affected",
"version": "Versions prior to 1.18.1\u202f "
},
{
"status": "affected",
"version": "Versions prior to 2.19.1\u202f "
}
]
}
],
"datePublic": "2023-12-07T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.\u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-08T05:37:52.680Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000219550/dsa-2023-361-security-update-for-dell-poweredge-server-bios-for-an-improper-privilege-management-security-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-32460",
"datePublished": "2023-12-08T05:37:52.680Z",
"dateReserved": "2023-05-09T06:05:24.994Z",
"dateUpdated": "2024-08-02T15:18:37.251Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}