Search

Find a vulnerability

Search criteria

    18 vulnerabilities found for oncell_g3150-hspa_firmware by moxa

    CVE-2018-11423 (GCVE-0-2018-11423)

    Vulnerability from nvd – Published: 2019-07-03 15:22 – Updated: 2024-08-05 08:10
    VLAI
    Summary
    There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:10:14.203Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-102.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-03T15:22:03.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-102.md"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11423",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-102.md",
                  "refsource": "MISC",
                  "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-102.md"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11423",
        "datePublished": "2019-07-03T15:22:03.000Z",
        "dateReserved": "2018-05-24T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:10:14.203Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11422 (GCVE-0-2018-11422)

    Vulnerability from nvd – Published: 2019-07-03 15:23 – Updated: 2024-08-05 08:10
    VLAI
    Summary
    Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands (including device reboot, configuration download or upload, or firmware upgrade) are accepted and executed by the device without authentication.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:10:14.136Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-104.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands (including device reboot, configuration download or upload, or firmware upgrade) are accepted and executed by the device without authentication."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-03T15:23:32.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-104.md"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11422",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands (including device reboot, configuration download or upload, or firmware upgrade) are accepted and executed by the device without authentication."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-104.md",
                  "refsource": "MISC",
                  "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-104.md"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11422",
        "datePublished": "2019-07-03T15:23:32.000Z",
        "dateReserved": "2018-05-24T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:10:14.136Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11421 (GCVE-0-2018-11421)

    Vulnerability from nvd – Published: 2019-07-03 15:24 – Updated: 2024-08-05 08:10
    VLAI
    Summary
    Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator's password. Under certain conditions, it's also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:10:14.054Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-103.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator\u0027s password. Under certain conditions, it\u0027s also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-03T15:24:45.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-103.md"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11421",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator\u0027s password. Under certain conditions, it\u0027s also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-103.md",
                  "refsource": "MISC",
                  "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-103.md"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11421",
        "datePublished": "2019-07-03T15:24:45.000Z",
        "dateReserved": "2018-05-24T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:10:14.054Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11420 (GCVE-0-2018-11420)

    Vulnerability from nvd – Published: 2019-07-03 15:25 – Updated: 2024-08-05 08:10
    VLAI
    Summary
    There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:10:13.854Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-101.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-03T15:25:58.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-101.md"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11420",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-101.md",
                  "refsource": "MISC",
                  "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-101.md"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11420",
        "datePublished": "2019-07-03T15:25:58.000Z",
        "dateReserved": "2018-05-24T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:10:13.854Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11427 (GCVE-0-2018-11427)

    Vulnerability from nvd – Published: 2019-07-03 14:46 – Updated: 2024-08-05 08:10
    VLAI
    Summary
    CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:10:14.139Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-106.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-03T14:46:54.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-106.md"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11427",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-106.md",
                  "refsource": "MISC",
                  "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-106.md"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11427",
        "datePublished": "2019-07-03T14:46:54.000Z",
        "dateReserved": "2018-05-24T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:10:14.139Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11426 (GCVE-0-2018-11426)

    Vulnerability from nvd – Published: 2019-07-03 14:50 – Updated: 2024-08-05 08:10
    VLAI
    Summary
    A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:10:14.334Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-105.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-03T14:50:09.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-105.md"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11426",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-105.md",
                  "refsource": "MISC",
                  "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-105.md"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11426",
        "datePublished": "2019-07-03T14:50:10.000Z",
        "dateReserved": "2018-05-24T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:10:14.334Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-5455 (GCVE-0-2018-5455)

    Vulnerability from nvd – Published: 2018-03-05 17:00 – Updated: 2024-08-05 05:33
    VLAI
    Summary
    A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa OnCell G3100-HSPA Series Affected: Moxa OnCell G3100-HSPA Series
    Date Public
    2018-03-05 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T05:33:44.372Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa OnCell G3100-HSPA Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa OnCell G3100-HSPA Series"
                }
              ]
            }
          ],
          "datePublic": "2018-03-05T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-565",
                  "description": "CWE-565",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-03-05T16:57:02.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2018-5455",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa OnCell G3100-HSPA Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa OnCell G3100-HSPA Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-565"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-5455",
        "datePublished": "2018-03-05T17:00:00.000Z",
        "dateReserved": "2018-01-12T00:00:00.000Z",
        "dateUpdated": "2024-08-05T05:33:44.372Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-5453 (GCVE-0-2018-5453)

    Vulnerability from nvd – Published: 2018-03-05 17:00 – Updated: 2024-08-05 05:33
    VLAI
    Summary
    An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa OnCell G3100-HSPA Series Affected: Moxa OnCell G3100-HSPA Series
    Date Public
    2018-03-05 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T05:33:44.390Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa OnCell G3100-HSPA Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa OnCell G3100-HSPA Series"
                }
              ]
            }
          ],
          "datePublic": "2018-03-05T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-130",
                  "description": "CWE-130",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-03-05T16:57:02.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2018-5453",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa OnCell G3100-HSPA Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa OnCell G3100-HSPA Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-130"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-5453",
        "datePublished": "2018-03-05T17:00:00.000Z",
        "dateReserved": "2018-01-12T00:00:00.000Z",
        "dateUpdated": "2024-08-05T05:33:44.390Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-5449 (GCVE-0-2018-5449)

    Vulnerability from nvd – Published: 2018-03-05 17:00 – Updated: 2024-08-05 05:33
    VLAI
    Summary
    A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does not check for a NULL value, allowing for an attacker to perform a denial of service attack.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa OnCell G3100-HSPA Series Affected: Moxa OnCell G3100-HSPA Series
    Date Public
    2018-03-05 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T05:33:44.399Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa OnCell G3100-HSPA Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa OnCell G3100-HSPA Series"
                }
              ]
            }
          ],
          "datePublic": "2018-03-05T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does not check for a NULL value, allowing for an attacker to perform a denial of service attack."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-476",
                  "description": "CWE-476",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-03-05T16:57:02.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2018-5449",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa OnCell G3100-HSPA Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa OnCell G3100-HSPA Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does not check for a NULL value, allowing for an attacker to perform a denial of service attack."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-476"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-5449",
        "datePublished": "2018-03-05T17:00:00.000Z",
        "dateReserved": "2018-01-12T00:00:00.000Z",
        "dateUpdated": "2024-08-05T05:33:44.399Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11420 (GCVE-0-2018-11420)

    Vulnerability from cvelistv5 – Published: 2019-07-03 15:25 – Updated: 2024-08-05 08:10
    VLAI
    Summary
    There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:10:13.854Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-101.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-03T15:25:58.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-101.md"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11420",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-101.md",
                  "refsource": "MISC",
                  "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-101.md"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11420",
        "datePublished": "2019-07-03T15:25:58.000Z",
        "dateReserved": "2018-05-24T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:10:13.854Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11421 (GCVE-0-2018-11421)

    Vulnerability from cvelistv5 – Published: 2019-07-03 15:24 – Updated: 2024-08-05 08:10
    VLAI
    Summary
    Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator's password. Under certain conditions, it's also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:10:14.054Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-103.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator\u0027s password. Under certain conditions, it\u0027s also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-03T15:24:45.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-103.md"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11421",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator\u0027s password. Under certain conditions, it\u0027s also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-103.md",
                  "refsource": "MISC",
                  "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-103.md"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11421",
        "datePublished": "2019-07-03T15:24:45.000Z",
        "dateReserved": "2018-05-24T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:10:14.054Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11422 (GCVE-0-2018-11422)

    Vulnerability from cvelistv5 – Published: 2019-07-03 15:23 – Updated: 2024-08-05 08:10
    VLAI
    Summary
    Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands (including device reboot, configuration download or upload, or firmware upgrade) are accepted and executed by the device without authentication.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:10:14.136Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-104.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands (including device reboot, configuration download or upload, or firmware upgrade) are accepted and executed by the device without authentication."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-03T15:23:32.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-104.md"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11422",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands (including device reboot, configuration download or upload, or firmware upgrade) are accepted and executed by the device without authentication."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-104.md",
                  "refsource": "MISC",
                  "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-104.md"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11422",
        "datePublished": "2019-07-03T15:23:32.000Z",
        "dateReserved": "2018-05-24T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:10:14.136Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11423 (GCVE-0-2018-11423)

    Vulnerability from cvelistv5 – Published: 2019-07-03 15:22 – Updated: 2024-08-05 08:10
    VLAI
    Summary
    There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:10:14.203Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-102.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-03T15:22:03.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-102.md"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11423",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-102.md",
                  "refsource": "MISC",
                  "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-102.md"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11423",
        "datePublished": "2019-07-03T15:22:03.000Z",
        "dateReserved": "2018-05-24T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:10:14.203Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11426 (GCVE-0-2018-11426)

    Vulnerability from cvelistv5 – Published: 2019-07-03 14:50 – Updated: 2024-08-05 08:10
    VLAI
    Summary
    A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:10:14.334Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-105.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-03T14:50:09.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-105.md"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11426",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-105.md",
                  "refsource": "MISC",
                  "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-105.md"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11426",
        "datePublished": "2019-07-03T14:50:10.000Z",
        "dateReserved": "2018-05-24T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:10:14.334Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11427 (GCVE-0-2018-11427)

    Vulnerability from cvelistv5 – Published: 2019-07-03 14:46 – Updated: 2024-08-05 08:10
    VLAI
    Summary
    CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:10:14.139Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-106.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-03T14:46:54.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-106.md"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11427",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-106.md",
                  "refsource": "MISC",
                  "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-106.md"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11427",
        "datePublished": "2019-07-03T14:46:54.000Z",
        "dateReserved": "2018-05-24T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:10:14.139Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-5453 (GCVE-0-2018-5453)

    Vulnerability from cvelistv5 – Published: 2018-03-05 17:00 – Updated: 2024-08-05 05:33
    VLAI
    Summary
    An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa OnCell G3100-HSPA Series Affected: Moxa OnCell G3100-HSPA Series
    Date Public
    2018-03-05 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T05:33:44.390Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa OnCell G3100-HSPA Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa OnCell G3100-HSPA Series"
                }
              ]
            }
          ],
          "datePublic": "2018-03-05T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-130",
                  "description": "CWE-130",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-03-05T16:57:02.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2018-5453",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa OnCell G3100-HSPA Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa OnCell G3100-HSPA Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-130"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-5453",
        "datePublished": "2018-03-05T17:00:00.000Z",
        "dateReserved": "2018-01-12T00:00:00.000Z",
        "dateUpdated": "2024-08-05T05:33:44.390Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-5455 (GCVE-0-2018-5455)

    Vulnerability from cvelistv5 – Published: 2018-03-05 17:00 – Updated: 2024-08-05 05:33
    VLAI
    Summary
    A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa OnCell G3100-HSPA Series Affected: Moxa OnCell G3100-HSPA Series
    Date Public
    2018-03-05 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T05:33:44.372Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa OnCell G3100-HSPA Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa OnCell G3100-HSPA Series"
                }
              ]
            }
          ],
          "datePublic": "2018-03-05T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-565",
                  "description": "CWE-565",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-03-05T16:57:02.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2018-5455",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa OnCell G3100-HSPA Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa OnCell G3100-HSPA Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-565"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-5455",
        "datePublished": "2018-03-05T17:00:00.000Z",
        "dateReserved": "2018-01-12T00:00:00.000Z",
        "dateUpdated": "2024-08-05T05:33:44.372Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-5449 (GCVE-0-2018-5449)

    Vulnerability from cvelistv5 – Published: 2018-03-05 17:00 – Updated: 2024-08-05 05:33
    VLAI
    Summary
    A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does not check for a NULL value, allowing for an attacker to perform a denial of service attack.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa OnCell G3100-HSPA Series Affected: Moxa OnCell G3100-HSPA Series
    Date Public
    2018-03-05 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T05:33:44.399Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa OnCell G3100-HSPA Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa OnCell G3100-HSPA Series"
                }
              ]
            }
          ],
          "datePublic": "2018-03-05T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does not check for a NULL value, allowing for an attacker to perform a denial of service attack."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-476",
                  "description": "CWE-476",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-03-05T16:57:02.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2018-5449",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa OnCell G3100-HSPA Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa OnCell G3100-HSPA Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does not check for a NULL value, allowing for an attacker to perform a denial of service attack."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-476"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-060-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-5449",
        "datePublished": "2018-03-05T17:00:00.000Z",
        "dateReserved": "2018-01-12T00:00:00.000Z",
        "dateUpdated": "2024-08-05T05:33:44.399Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }