Search criteria

10 vulnerabilities found for nj-pd3001_firmware by omron

CVE-2024-33687 (GCVE-0-2024-33687)

Vulnerability from nvd – Published: 2024-06-24 15:03 – Updated: 2025-03-13 14:36
VLAI?
Summary
Insufficient verification of data authenticity issue exists in NJ Series CPU Unit all versions and NX Series CPU Unit all versions. If a user program in the affected product is altered, the product may not be able to detect the alteration.
CWE
  • Insufficient verification of data authenticity
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-33687",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-24T20:23:44.445669Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-345",
                "description": "CWE-345 Insufficient Verification of Data Authenticity",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-13T14:36:56.825Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:36:04.543Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.fa.omron.co.jp/product/security/assets/pdf/en/OMSR-2024-004_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU92504444/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NJ Series CPU Unit",
          "vendor": "OMRON Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "NX Series CPU Unit",
          "vendor": "OMRON Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Insufficient verification of data authenticity issue exists in NJ Series CPU Unit all versions and NX Series CPU Unit all versions. If a user program in the affected product is altered, the product may not be able to detect the alteration."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Insufficient verification of data authenticity",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-24T15:03:05.467Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.fa.omron.co.jp/product/security/assets/pdf/en/OMSR-2024-004_en.pdf"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU92504444/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2024-33687",
    "datePublished": "2024-06-24T15:03:05.467Z",
    "dateReserved": "2024-04-26T07:55:08.563Z",
    "dateUpdated": "2025-03-13T14:36:56.825Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-27396 (GCVE-0-2023-27396)

Vulnerability from nvd – Published: 2023-06-19 00:00 – Updated: 2024-12-24 16:45
VLAI?
Summary
FINS (Factory Interface Network Service) is a message communication protocol, which is designed to be used in closed FA (Factory Automation) networks, and is used in FA networks composed of OMRON products. Multiple OMRON products that implement FINS protocol contain following security issues -- (1)Plaintext communication, and (2)No authentication required. When FINS messages are intercepted, the contents may be retrieved. When arbitrary FINS messages are injected, any commands may be executed on, or the system information may be retrieved from, the affected device. Affected products and versions are as follows: SYSMAC CS-series CPU Units, all versions, SYSMAC CJ-series CPU Units, all versions, SYSMAC CP-series CPU Units, all versions, SYSMAC NJ-series CPU Units, all versions, SYSMAC NX1P-series CPU Units, all versions, SYSMAC NX102-series CPU Units, all versions, and SYSMAC NX7 Database Connection CPU Units (Ver.1.16 or later)
CWE
  • Insecure Design
Assigner
Impacted products
Vendor Product Version
OMRON Corporation Multiple OMRON products which implement FINS protocol Affected: SYSMAC CS-series CPU Units all versions, SYSMAC CJ-series CPU Units all versions, SYSMAC CP-series CPU Units all versions, SYSMAC NJ-series CPU Units all versions, SYSMAC NX1P-series CPU Units all versions, SYSMAC NX102-series CPU Units all versions, and SYSMAC NX7 Database Connection CPU Units Ver.1.16 or later
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:09:43.381Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-346-02"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2023-003_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.fa.omron.co.jp/product/vulnerability/OMSR-2023-003_ja.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/ta/JVNTA91513661/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/ta/JVNTA91513661/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-063-03"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-27396",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-24T16:45:15.508549Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-306",
                "description": "CWE-306 Missing Authentication for Critical Function",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-24T16:45:20.428Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Multiple OMRON products which implement FINS protocol",
          "vendor": "OMRON Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "SYSMAC CS-series CPU Units all versions, SYSMAC CJ-series CPU Units all versions, SYSMAC CP-series CPU Units all versions, SYSMAC NJ-series CPU Units all versions, SYSMAC NX1P-series CPU Units all versions, SYSMAC NX102-series CPU Units all versions, and SYSMAC NX7 Database Connection CPU Units Ver.1.16 or later"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "FINS (Factory Interface Network Service) is a message communication protocol, which is designed to be used in closed FA (Factory Automation) networks, and is used in FA networks composed of OMRON products. Multiple OMRON products that implement FINS protocol contain following security issues -- (1)Plaintext communication, and (2)No authentication required. When FINS messages are intercepted, the contents may be retrieved. When arbitrary FINS messages are injected, any commands may be executed on, or the system information may be retrieved from, the affected device. Affected products and versions are as follows: SYSMAC CS-series CPU Units, all versions, SYSMAC CJ-series CPU Units, all versions, SYSMAC CP-series CPU Units, all versions, SYSMAC NJ-series CPU Units, all versions, SYSMAC NX1P-series CPU Units, all versions, SYSMAC NX102-series CPU Units, all versions, and SYSMAC NX7 Database Connection CPU Units (Ver.1.16 or later)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Insecure Design",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-19T00:00:00",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-346-02"
        },
        {
          "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2023-003_en.pdf"
        },
        {
          "url": "https://www.fa.omron.co.jp/product/vulnerability/OMSR-2023-003_ja.pdf"
        },
        {
          "url": "https://jvn.jp/en/ta/JVNTA91513661/"
        },
        {
          "url": "https://jvn.jp/ta/JVNTA91513661/"
        },
        {
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-063-03"
        },
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2023-27396",
    "datePublished": "2023-06-19T00:00:00",
    "dateReserved": "2023-03-15T00:00:00",
    "dateUpdated": "2024-12-24T16:45:20.428Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34151 (GCVE-0-2022-34151)

Vulnerability from nvd – Published: 2022-07-04 01:51 – Updated: 2024-08-03 08:16
VLAI?
Summary
Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller.
Severity ?
No CVSS data available.
CWE
  • Use of Hard-coded Credentials
Assigner
Impacted products
Vendor Product Version
OMRON Corporation Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series Affected: Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:16:17.136Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
          "vendor": "OMRON Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Use of Hard-coded Credentials",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-04T02:25:19",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2022-34151",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "OMRON Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf",
              "refsource": "MISC",
              "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
            },
            {
              "name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-34151",
    "datePublished": "2022-07-04T01:51:00",
    "dateReserved": "2022-06-21T00:00:00",
    "dateUpdated": "2024-08-03T08:16:17.136Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-33971 (GCVE-0-2022-33971)

Vulnerability from nvd – Published: 2022-07-04 01:50 – Updated: 2024-08-03 08:16
VLAI?
Summary
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication between the controller and the specific software used by OMRON internally to cause a denial-of-service (DoS) condition or execute a malicious program.
Severity ?
No CVSS data available.
CWE
  • Authentication Bypass by Capture-replay
Assigner
Impacted products
Vendor Product Version
OMRON Corporation Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series Affected: Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:16:16.110Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-002_en.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
          "vendor": "OMRON Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication between the controller and the specific software used by OMRON internally to cause a denial-of-service (DoS) condition or execute a malicious program."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Authentication Bypass by Capture-replay",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-04T01:50:54",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-002_en.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2022-33971",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "OMRON Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication between the controller and the specific software used by OMRON internally to cause a denial-of-service (DoS) condition or execute a malicious program."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Authentication Bypass by Capture-replay"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
            },
            {
              "name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-002_en.pdf",
              "refsource": "MISC",
              "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-002_en.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-33971",
    "datePublished": "2022-07-04T01:50:54",
    "dateReserved": "2022-06-21T00:00:00",
    "dateUpdated": "2024-08-03T08:16:16.110Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-33208 (GCVE-0-2022-33208)

Vulnerability from nvd – Published: 2022-07-04 01:50 – Updated: 2024-08-03 08:01
VLAI?
Summary
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software 'Sysmac Studio' and/or a Programmable Terminal (PT) to access the controller.
Severity ?
No CVSS data available.
CWE
  • Authentication Bypass by Capture-replay
Assigner
Impacted products
Vendor Product Version
OMRON Corporation Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series Affected: Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:01:20.422Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
          "vendor": "OMRON Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software \u0027Sysmac Studio\u0027 and/or a Programmable Terminal (PT) to access the controller."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Authentication Bypass by Capture-replay",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-04T02:25:11",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2022-33208",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "OMRON Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software \u0027Sysmac Studio\u0027 and/or a Programmable Terminal (PT) to access the controller."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Authentication Bypass by Capture-replay"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf",
              "refsource": "MISC",
              "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
            },
            {
              "name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-33208",
    "datePublished": "2022-07-04T01:50:44",
    "dateReserved": "2022-06-21T00:00:00",
    "dateUpdated": "2024-08-03T08:01:20.422Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-33687 (GCVE-0-2024-33687)

Vulnerability from cvelistv5 – Published: 2024-06-24 15:03 – Updated: 2025-03-13 14:36
VLAI?
Summary
Insufficient verification of data authenticity issue exists in NJ Series CPU Unit all versions and NX Series CPU Unit all versions. If a user program in the affected product is altered, the product may not be able to detect the alteration.
CWE
  • Insufficient verification of data authenticity
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-33687",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-24T20:23:44.445669Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-345",
                "description": "CWE-345 Insufficient Verification of Data Authenticity",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-13T14:36:56.825Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:36:04.543Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.fa.omron.co.jp/product/security/assets/pdf/en/OMSR-2024-004_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU92504444/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NJ Series CPU Unit",
          "vendor": "OMRON Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "NX Series CPU Unit",
          "vendor": "OMRON Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Insufficient verification of data authenticity issue exists in NJ Series CPU Unit all versions and NX Series CPU Unit all versions. If a user program in the affected product is altered, the product may not be able to detect the alteration."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Insufficient verification of data authenticity",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-24T15:03:05.467Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.fa.omron.co.jp/product/security/assets/pdf/en/OMSR-2024-004_en.pdf"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU92504444/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2024-33687",
    "datePublished": "2024-06-24T15:03:05.467Z",
    "dateReserved": "2024-04-26T07:55:08.563Z",
    "dateUpdated": "2025-03-13T14:36:56.825Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-27396 (GCVE-0-2023-27396)

Vulnerability from cvelistv5 – Published: 2023-06-19 00:00 – Updated: 2024-12-24 16:45
VLAI?
Summary
FINS (Factory Interface Network Service) is a message communication protocol, which is designed to be used in closed FA (Factory Automation) networks, and is used in FA networks composed of OMRON products. Multiple OMRON products that implement FINS protocol contain following security issues -- (1)Plaintext communication, and (2)No authentication required. When FINS messages are intercepted, the contents may be retrieved. When arbitrary FINS messages are injected, any commands may be executed on, or the system information may be retrieved from, the affected device. Affected products and versions are as follows: SYSMAC CS-series CPU Units, all versions, SYSMAC CJ-series CPU Units, all versions, SYSMAC CP-series CPU Units, all versions, SYSMAC NJ-series CPU Units, all versions, SYSMAC NX1P-series CPU Units, all versions, SYSMAC NX102-series CPU Units, all versions, and SYSMAC NX7 Database Connection CPU Units (Ver.1.16 or later)
CWE
  • Insecure Design
Assigner
Impacted products
Vendor Product Version
OMRON Corporation Multiple OMRON products which implement FINS protocol Affected: SYSMAC CS-series CPU Units all versions, SYSMAC CJ-series CPU Units all versions, SYSMAC CP-series CPU Units all versions, SYSMAC NJ-series CPU Units all versions, SYSMAC NX1P-series CPU Units all versions, SYSMAC NX102-series CPU Units all versions, and SYSMAC NX7 Database Connection CPU Units Ver.1.16 or later
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:09:43.381Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-346-02"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2023-003_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.fa.omron.co.jp/product/vulnerability/OMSR-2023-003_ja.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/ta/JVNTA91513661/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/ta/JVNTA91513661/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-063-03"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-27396",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-24T16:45:15.508549Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-306",
                "description": "CWE-306 Missing Authentication for Critical Function",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-24T16:45:20.428Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Multiple OMRON products which implement FINS protocol",
          "vendor": "OMRON Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "SYSMAC CS-series CPU Units all versions, SYSMAC CJ-series CPU Units all versions, SYSMAC CP-series CPU Units all versions, SYSMAC NJ-series CPU Units all versions, SYSMAC NX1P-series CPU Units all versions, SYSMAC NX102-series CPU Units all versions, and SYSMAC NX7 Database Connection CPU Units Ver.1.16 or later"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "FINS (Factory Interface Network Service) is a message communication protocol, which is designed to be used in closed FA (Factory Automation) networks, and is used in FA networks composed of OMRON products. Multiple OMRON products that implement FINS protocol contain following security issues -- (1)Plaintext communication, and (2)No authentication required. When FINS messages are intercepted, the contents may be retrieved. When arbitrary FINS messages are injected, any commands may be executed on, or the system information may be retrieved from, the affected device. Affected products and versions are as follows: SYSMAC CS-series CPU Units, all versions, SYSMAC CJ-series CPU Units, all versions, SYSMAC CP-series CPU Units, all versions, SYSMAC NJ-series CPU Units, all versions, SYSMAC NX1P-series CPU Units, all versions, SYSMAC NX102-series CPU Units, all versions, and SYSMAC NX7 Database Connection CPU Units (Ver.1.16 or later)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Insecure Design",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-19T00:00:00",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-346-02"
        },
        {
          "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2023-003_en.pdf"
        },
        {
          "url": "https://www.fa.omron.co.jp/product/vulnerability/OMSR-2023-003_ja.pdf"
        },
        {
          "url": "https://jvn.jp/en/ta/JVNTA91513661/"
        },
        {
          "url": "https://jvn.jp/ta/JVNTA91513661/"
        },
        {
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-063-03"
        },
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-02"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2023-27396",
    "datePublished": "2023-06-19T00:00:00",
    "dateReserved": "2023-03-15T00:00:00",
    "dateUpdated": "2024-12-24T16:45:20.428Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34151 (GCVE-0-2022-34151)

Vulnerability from cvelistv5 – Published: 2022-07-04 01:51 – Updated: 2024-08-03 08:16
VLAI?
Summary
Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller.
Severity ?
No CVSS data available.
CWE
  • Use of Hard-coded Credentials
Assigner
Impacted products
Vendor Product Version
OMRON Corporation Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series Affected: Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:16:17.136Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
          "vendor": "OMRON Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Use of Hard-coded Credentials",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-04T02:25:19",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2022-34151",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "OMRON Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf",
              "refsource": "MISC",
              "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
            },
            {
              "name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-34151",
    "datePublished": "2022-07-04T01:51:00",
    "dateReserved": "2022-06-21T00:00:00",
    "dateUpdated": "2024-08-03T08:16:17.136Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-33971 (GCVE-0-2022-33971)

Vulnerability from cvelistv5 – Published: 2022-07-04 01:50 – Updated: 2024-08-03 08:16
VLAI?
Summary
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication between the controller and the specific software used by OMRON internally to cause a denial-of-service (DoS) condition or execute a malicious program.
Severity ?
No CVSS data available.
CWE
  • Authentication Bypass by Capture-replay
Assigner
Impacted products
Vendor Product Version
OMRON Corporation Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series Affected: Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:16:16.110Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-002_en.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
          "vendor": "OMRON Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication between the controller and the specific software used by OMRON internally to cause a denial-of-service (DoS) condition or execute a malicious program."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Authentication Bypass by Capture-replay",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-04T01:50:54",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-002_en.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2022-33971",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "OMRON Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication between the controller and the specific software used by OMRON internally to cause a denial-of-service (DoS) condition or execute a malicious program."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Authentication Bypass by Capture-replay"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
            },
            {
              "name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-002_en.pdf",
              "refsource": "MISC",
              "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-002_en.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-33971",
    "datePublished": "2022-07-04T01:50:54",
    "dateReserved": "2022-06-21T00:00:00",
    "dateUpdated": "2024-08-03T08:16:16.110Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-33208 (GCVE-0-2022-33208)

Vulnerability from cvelistv5 – Published: 2022-07-04 01:50 – Updated: 2024-08-03 08:01
VLAI?
Summary
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software 'Sysmac Studio' and/or a Programmable Terminal (PT) to access the controller.
Severity ?
No CVSS data available.
CWE
  • Authentication Bypass by Capture-replay
Assigner
Impacted products
Vendor Product Version
OMRON Corporation Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series Affected: Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:01:20.422Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
          "vendor": "OMRON Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software \u0027Sysmac Studio\u0027 and/or a Programmable Terminal (PT) to access the controller."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Authentication Bypass by Capture-replay",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-04T02:25:11",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2022-33208",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "OMRON Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software \u0027Sysmac Studio\u0027 and/or a Programmable Terminal (PT) to access the controller."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Authentication Bypass by Capture-replay"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf",
              "refsource": "MISC",
              "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
            },
            {
              "name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2022-33208",
    "datePublished": "2022-07-04T01:50:44",
    "dateReserved": "2022-06-21T00:00:00",
    "dateUpdated": "2024-08-03T08:01:20.422Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",