Search criteria

15 vulnerabilities found for n300rh by totolink

VAR-202506-1056

Vulnerability from variot - Updated: 2025-08-09 23:19

A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been classified as problematic. This affects an unknown part of the file /boafrm/formFilter of the component HTTP POST Message Handler. The manipulation of the argument url leads to denial of service. The exploit has been disclosed to the public and may be used. TOTOLINK of N300RH A vulnerability exists in firmware related to improper shutdown and release of resources.Service operation interruption (DoS) It may be in a state. The TOTOLINK N300RH is a long-range wireless router released by China's TOTOLINK Electronics. It supports the IEEE 802.11n standard and offers a maximum wireless transmission rate of 300Mbps

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202506-1056",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "totolink",
        "version": "6.1c.1390_b20191101"
      },
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": "n300rh  firmware  6.1c.1390 b20191101"
      },
      {
        "model": "n300rh",
        "scope": null,
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "n300rh 6.1c.1390 b20191101",
        "scope": null,
        "trust": 0.6,
        "vendor": "totolink",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17706"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-009682"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-6401"
      }
    ]
  },
  "cve": "CVE-2025-6401",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 2.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 4.4,
            "id": "CVE-2025-6401",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 1.0,
            "vectorString": "AV:A/AC:M/Au:S/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Adjacent Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Partial",
            "baseScore": 2.3,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-009682",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Low",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:A/AC:M/Au:S/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 2.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 4.4,
            "id": "CNVD-2025-17706",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:A/AC:M/Au:S/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.1,
            "id": "CVE-2025-6401",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "OTHER",
            "availabilityImpact": "Low",
            "baseScore": 3.5,
            "baseSeverity": "Low",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-009682",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2025-6401",
            "trust": 1.0,
            "value": "Low"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-009682",
            "trust": 0.8,
            "value": "Low"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-17706",
            "trust": 0.6,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17706"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-009682"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-6401"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been classified as problematic. This affects an unknown part of the file /boafrm/formFilter of the component HTTP POST Message Handler. The manipulation of the argument url leads to denial of service. The exploit has been disclosed to the public and may be used. TOTOLINK of N300RH A vulnerability exists in firmware related to improper shutdown and release of resources.Service operation interruption (DoS) It may be in a state. The TOTOLINK N300RH is a long-range wireless router released by China\u0027s TOTOLINK Electronics. It supports the IEEE 802.11n standard and offers a maximum wireless transmission rate of 300Mbps",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-6401"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-009682"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-17706"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-6401",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "313395",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-009682",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-17706",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17706"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-009682"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-6401"
      }
    ]
  },
  "id": "VAR-202506-1056",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17706"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17706"
      }
    ]
  },
  "last_update_date": "2025-08-09T23:19:01.833000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-404",
        "trust": 1.0
      },
      {
        "problemtype": "Improper shutdown and release of resources (CWE-404) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-009682"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-6401"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/d2pq/cve/blob/main/616/21.md"
      },
      {
        "trust": 1.8,
        "url": "https://github.com/d2pq/cve/blob/main/616/21.md#poc"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.313395"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.597688"
      },
      {
        "trust": 1.8,
        "url": "https://www.totolink.net/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-6401"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.313395"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17706"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-009682"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-6401"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17706"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-009682"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-6401"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-08-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-17706"
      },
      {
        "date": "2025-07-23T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-009682"
      },
      {
        "date": "2025-06-21T07:15:23.197000",
        "db": "NVD",
        "id": "CVE-2025-6401"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-08-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-17706"
      },
      {
        "date": "2025-07-23T08:41:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-009682"
      },
      {
        "date": "2025-06-25T20:14:01.440000",
        "db": "NVD",
        "id": "CVE-2025-6401"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "TOTOLINK\u00a0 of \u00a0N300RH\u00a0 Improper Shutdown and Release of Resources in Firmware Vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-009682"
      }
    ],
    "trust": 0.8
  }
}

VAR-202506-1063

Vulnerability from variot - Updated: 2025-07-04 23:50

A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101 and classified as critical. Affected by this issue is some unknown functionality of the file /boafrm/formPortFw of the component HTTP POST Message Handler. The manipulation of the argument service_type leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. TOTOLINK of N300RH The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK N300RH is a long-distance wireless router from China's TOTOLINK Electronics.

TOTOLINK N300RH has a buffer overflow vulnerability, which is caused by the parameter service_type in the file /boafrm/formPortFw failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202506-1063",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "totolink",
        "version": "6.1c.1390_b20191101"
      },
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": "n300rh  firmware  6.1c.1390 b20191101"
      },
      {
        "model": "n300rh",
        "scope": null,
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "n300rh 6.1c.1390 b20191101",
        "scope": null,
        "trust": 0.6,
        "vendor": "totolink",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-14223"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007617"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-6400"
      }
    ]
  },
  "cve": "CVE-2025-6400",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2025-6400",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-007617",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2025-14223",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-6400",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-007617",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2025-6400",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-007617",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-14223",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-14223"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007617"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-6400"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101 and classified as critical. Affected by this issue is some unknown functionality of the file /boafrm/formPortFw of the component HTTP POST Message Handler. The manipulation of the argument service_type leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. TOTOLINK of N300RH The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK N300RH is a long-distance wireless router from China\u0027s TOTOLINK Electronics. \n\nTOTOLINK N300RH has a buffer overflow vulnerability, which is caused by the parameter service_type in the file /boafrm/formPortFw failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-6400"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007617"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-14223"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-6400",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "313394",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007617",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-14223",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-14223"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007617"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-6400"
      }
    ]
  },
  "id": "VAR-202506-1063",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-14223"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-14223"
      }
    ]
  },
  "last_update_date": "2025-07-04T23:50:29.648000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Buffer error (CWE-119) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Classic buffer overflow (CWE-120) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007617"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-6400"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/d2pq/cve/blob/main/616/20.md"
      },
      {
        "trust": 1.8,
        "url": "https://github.com/d2pq/cve/blob/main/616/20.md#poc"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.313394"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.597687"
      },
      {
        "trust": 1.8,
        "url": "https://www.totolink.net/"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.313394"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-6400"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-14223"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007617"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-6400"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-14223"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007617"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-6400"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-06-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-14223"
      },
      {
        "date": "2025-07-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-007617"
      },
      {
        "date": "2025-06-21T06:15:19.577000",
        "db": "NVD",
        "id": "CVE-2025-6400"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-06-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-14223"
      },
      {
        "date": "2025-07-01T03:28:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-007617"
      },
      {
        "date": "2025-06-25T20:13:52.420000",
        "db": "NVD",
        "id": "CVE-2025-6400"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "TOTOLINK\u00a0 of \u00a0N300RH\u00a0 Buffer error vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007617"
      }
    ],
    "trust": 0.8
  }
}

VAR-202505-1806

Vulnerability from variot - Updated: 2025-05-29 23:39

A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been rated as critical. Affected by this issue is the function CloudACMunualUpdateUserdata of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument url leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. TOTOLINK of N300RH The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK N300RH is a long-distance wireless router from China's TOTOLINK Electronics.

TOTOLINK N300RH has a command injection vulnerability, which is caused by the failure of the parameter url in the file /cgi-bin/cstecgi.cgi to properly filter special characters and commands in the constructed command. No detailed vulnerability details are currently provided

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202505-1806",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "totolink",
        "version": "6.1c.1390_b20191101"
      },
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": "n300rh  firmware  6.1c.1390 b20191101"
      },
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "n300rh",
        "scope": null,
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "n300rh 6.1c.1390 b20191101",
        "scope": null,
        "trust": 0.6,
        "vendor": "totolink",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10919"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005680"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4849"
      }
    ]
  },
  "cve": "CVE-2025-4849",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CVE-2025-4849",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Partial",
            "baseScore": 6.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-005680",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2025-10919",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-4849",
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2025-4849",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-005680",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2025-4849",
            "trust": 1.0,
            "value": "Medium"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2025-4849",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-005680",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-10919",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10919"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005680"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4849"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4849"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been rated as critical. Affected by this issue is the function CloudACMunualUpdateUserdata of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument url leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. TOTOLINK of N300RH The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK N300RH is a long-distance wireless router from China\u0027s TOTOLINK Electronics. \n\nTOTOLINK N300RH has a command injection vulnerability, which is caused by the failure of the parameter url in the file /cgi-bin/cstecgi.cgi to properly filter special characters and commands in the constructed command. No detailed vulnerability details are currently provided",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-4849"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005680"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-10919"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-4849",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "309320",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005680",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-10919",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10919"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005680"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4849"
      }
    ]
  },
  "id": "VAR-202505-1806",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10919"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10919"
      }
    ]
  },
  "last_update_date": "2025-05-29T23:39:39.242000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-74",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-77",
        "trust": 1.0
      },
      {
        "problemtype": "injection (CWE-74) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Command injection (CWE-77) [NVD evaluation ]",
        "trust": 0.8
      },
      {
        "problemtype": " Command injection (CWE-77) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005680"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4849"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.309320"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.575072"
      },
      {
        "trust": 1.8,
        "url": "https://www.totolink.net/"
      },
      {
        "trust": 1.6,
        "url": "https://github.com/ch13hh/tmp_store_cc/blob/main/tt/ta/m1.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.309320"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-4849"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10919"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005680"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4849"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10919"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005680"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4849"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-10919"
      },
      {
        "date": "2025-05-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-005680"
      },
      {
        "date": "2025-05-18T03:15:23.087000",
        "db": "NVD",
        "id": "CVE-2025-4849"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-10919"
      },
      {
        "date": "2025-05-26T08:44:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-005680"
      },
      {
        "date": "2025-05-24T00:55:22.313000",
        "db": "NVD",
        "id": "CVE-2025-4849"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "TOTOLINK\u00a0 of \u00a0N300RH\u00a0 Injection Vulnerability in Firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005680"
      }
    ],
    "trust": 0.8
  }
}

VAR-202505-1841

Vulnerability from variot - Updated: 2025-05-29 23:29

A vulnerability classified as critical has been found in TOTOLINK N300RH 6.1c.1390_B20191101. This affects the function setUnloadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument plugin_name leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. TOTOLINK of N300RH The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK N300RH is a long-distance wireless router from China's TOTOLINK Electronics.

TOTOLINK N300RH has a command injection vulnerability, which is caused by the parameter plugin_name in the file /cgi-bin/cstecgi.cgi failing to properly filter special characters and commands in the constructed command. No detailed vulnerability details are currently provided

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202505-1841",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "totolink",
        "version": "6.1c.1390_b20191101"
      },
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": "n300rh  firmware  6.1c.1390 b20191101"
      },
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "n300rh",
        "scope": null,
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "n300rh 6.1c.1390 b20191101",
        "scope": null,
        "trust": 0.6,
        "vendor": "totolink",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10918"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005654"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4850"
      }
    ]
  },
  "cve": "CVE-2025-4850",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CVE-2025-4850",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Partial",
            "baseScore": 6.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-005654",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2025-10918",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-4850",
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "Low",
            "baseScore": 6.3,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-005654",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2025-4850",
            "trust": 1.0,
            "value": "Medium"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-005654",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-10918",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10918"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005654"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4850"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability classified as critical has been found in TOTOLINK N300RH 6.1c.1390_B20191101. This affects the function setUnloadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument plugin_name leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. TOTOLINK of N300RH The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK N300RH is a long-distance wireless router from China\u0027s TOTOLINK Electronics. \n\nTOTOLINK N300RH has a command injection vulnerability, which is caused by the parameter plugin_name in the file /cgi-bin/cstecgi.cgi failing to properly filter special characters and commands in the constructed command. No detailed vulnerability details are currently provided",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-4850"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005654"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-10918"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-4850",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "309321",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005654",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-10918",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10918"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005654"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4850"
      }
    ]
  },
  "id": "VAR-202505-1841",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10918"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10918"
      }
    ]
  },
  "last_update_date": "2025-05-29T23:29:02.559000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-74",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-77",
        "trust": 1.0
      },
      {
        "problemtype": "injection (CWE-74) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Command injection (CWE-77) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Command injection (CWE-77) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005654"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4850"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.309321"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.575073"
      },
      {
        "trust": 1.8,
        "url": "https://www.totolink.net/"
      },
      {
        "trust": 1.6,
        "url": "https://github.com/ch13hh/tmp_store_cc/blob/main/tt/ta/m2.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.309321"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-4850"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10918"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005654"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4850"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10918"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005654"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4850"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-10918"
      },
      {
        "date": "2025-05-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-005654"
      },
      {
        "date": "2025-05-18T03:15:23.280000",
        "db": "NVD",
        "id": "CVE-2025-4850"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-10918"
      },
      {
        "date": "2025-05-26T04:58:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-005654"
      },
      {
        "date": "2025-05-24T00:57:35.620000",
        "db": "NVD",
        "id": "CVE-2025-4850"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "TOTOLINK\u00a0 of \u00a0N300RH\u00a0 Injection Vulnerability in Firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005654"
      }
    ],
    "trust": 0.8
  }
}

VAR-202505-1840

Vulnerability from variot - Updated: 2025-05-29 19:32

A vulnerability classified as critical was found in TOTOLINK N300RH 6.1c.1390_B20191101. This vulnerability affects the function setUploadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. TOTOLINK of N300RH The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK N300RH is a long-distance wireless router from China's TOTOLINK Electronics.

TOTOLINK N300RH has a command injection vulnerability, which is caused by the parameter FileName in the file /cgi-bin/cstecgi.cgi failing to properly filter special characters and commands in the constructed command. No detailed vulnerability details are currently provided

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202505-1840",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "totolink",
        "version": "6.1c.1390_b20191101"
      },
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": "n300rh  firmware  6.1c.1390 b20191101"
      },
      {
        "model": "n300rh",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "n300rh",
        "scope": null,
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "n300rh 6.1c.1390 b20191101",
        "scope": null,
        "trust": 0.6,
        "vendor": "totolink",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10917"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005681"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4851"
      }
    ]
  },
  "cve": "CVE-2025-4851",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CVE-2025-4851",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Partial",
            "baseScore": 6.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-005681",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2025-10917",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-4851",
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2025-4851",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-005681",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2025-4851",
            "trust": 1.0,
            "value": "Medium"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2025-4851",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-005681",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-10917",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10917"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005681"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4851"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4851"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability classified as critical was found in TOTOLINK N300RH 6.1c.1390_B20191101. This vulnerability affects the function setUploadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. TOTOLINK of N300RH The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK N300RH is a long-distance wireless router from China\u0027s TOTOLINK Electronics. \n\nTOTOLINK N300RH has a command injection vulnerability, which is caused by the parameter FileName in the file /cgi-bin/cstecgi.cgi failing to properly filter special characters and commands in the constructed command. No detailed vulnerability details are currently provided",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-4851"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005681"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-10917"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-4851",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "309322",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005681",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-10917",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10917"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005681"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4851"
      }
    ]
  },
  "id": "VAR-202505-1840",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10917"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10917"
      }
    ]
  },
  "last_update_date": "2025-05-29T19:32:18.154000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-74",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-77",
        "trust": 1.0
      },
      {
        "problemtype": "injection (CWE-74) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Command injection (CWE-77) [NVD evaluation ]",
        "trust": 0.8
      },
      {
        "problemtype": " Command injection (CWE-77) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005681"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4851"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.309322"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.575074"
      },
      {
        "trust": 1.8,
        "url": "https://www.totolink.net/"
      },
      {
        "trust": 1.6,
        "url": "https://github.com/ch13hh/tmp_store_cc/blob/main/tt/ta/m3.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.309322"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-4851"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10917"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005681"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4851"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10917"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005681"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-4851"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-10917"
      },
      {
        "date": "2025-05-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-005681"
      },
      {
        "date": "2025-05-18T04:15:23.360000",
        "db": "NVD",
        "id": "CVE-2025-4851"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-10917"
      },
      {
        "date": "2025-05-26T08:46:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-005681"
      },
      {
        "date": "2025-05-24T01:03:29.400000",
        "db": "NVD",
        "id": "CVE-2025-4851"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "TOTOLINK\u00a0 of \u00a0N300RH\u00a0 Injection Vulnerability in Firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-005681"
      }
    ],
    "trust": 0.8
  }
}

CVE-2025-6401 (GCVE-0-2025-6401)

Vulnerability from nvd – Published: 2025-06-21 06:31 – Updated: 2025-06-23 19:27
VLAI?
Title
TOTOLINK N300RH HTTP POST Message formFilter denial of service
Summary
A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been classified as problematic. This affects an unknown part of the file /boafrm/formFilter of the component HTTP POST Message Handler. The manipulation of the argument url leads to denial of service. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
TOTOLINK N300RH Affected: 6.1c.1390_B20191101
Create a notification for this product.
Credits
yuhongxiang (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-6401",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-23T16:09:27.308682Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-23T19:27:48.226Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/d2pq/cve/blob/main/616/21.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP POST Message Handler"
          ],
          "product": "N300RH",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "6.1c.1390_B20191101"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yuhongxiang (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been classified as problematic. This affects an unknown part of the file /boafrm/formFilter of the component HTTP POST Message Handler. The manipulation of the argument url leads to denial of service. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in TOTOLINK N300RH 6.1c.1390_B20191101 ausgemacht. Sie wurde als problematisch eingestuft. Es betrifft eine unbekannte Funktion der Datei /boafrm/formFilter der Komponente HTTP POST Message Handler. Mittels dem Manipulieren des Arguments url mit unbekannten Daten kann eine denial of service-Schwachstelle ausgenutzt werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 2.3,
            "vectorString": "AV:A/AC:M/Au:S/C:N/I:N/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-404",
              "description": "Denial of Service",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-21T06:31:08.227Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-313395 | TOTOLINK N300RH HTTP POST Message formFilter denial of service",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.313395"
        },
        {
          "name": "VDB-313395 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.313395"
        },
        {
          "name": "Submit #597688 | TOTOLINK  N300RH_V4 V6.1c.1390_B20191101 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.597688"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/d2pq/cve/blob/main/616/21.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/d2pq/cve/blob/main/616/21.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-20T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-20T12:43:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK N300RH HTTP POST Message formFilter denial of service"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-6401",
    "datePublished": "2025-06-21T06:31:08.227Z",
    "dateReserved": "2025-06-20T10:38:48.055Z",
    "dateUpdated": "2025-06-23T19:27:48.226Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-6400 (GCVE-0-2025-6400)

Vulnerability from nvd – Published: 2025-06-21 05:31 – Updated: 2025-06-23 19:27
VLAI?
Title
TOTOLINK N300RH HTTP POST Message formPortFw buffer overflow
Summary
A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101 and classified as critical. Affected by this issue is some unknown functionality of the file /boafrm/formPortFw of the component HTTP POST Message Handler. The manipulation of the argument service_type leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
TOTOLINK N300RH Affected: 6.1c.1390_B20191101
Create a notification for this product.
Credits
yuhongxiang (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-6400",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-23T16:09:32.157775Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-23T19:27:53.229Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/d2pq/cve/blob/main/616/20.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP POST Message Handler"
          ],
          "product": "N300RH",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "6.1c.1390_B20191101"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yuhongxiang (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101 and classified as critical. Affected by this issue is some unknown functionality of the file /boafrm/formPortFw of the component HTTP POST Message Handler. The manipulation of the argument service_type leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in TOTOLINK N300RH 6.1c.1390_B20191101 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um eine nicht exakt ausgemachte Funktion der Datei /boafrm/formPortFw der Komponente HTTP POST Message Handler. Durch Manipulation des Arguments service_type mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-21T05:31:08.158Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-313394 | TOTOLINK N300RH HTTP POST Message formPortFw buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.313394"
        },
        {
          "name": "VDB-313394 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.313394"
        },
        {
          "name": "Submit #597687 | TOTOLINK N300RH_V4 V6.1c.1390_B20191101 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.597687"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/d2pq/cve/blob/main/616/20.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/d2pq/cve/blob/main/616/20.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-20T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-20T12:43:52.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK N300RH HTTP POST Message formPortFw buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-6400",
    "datePublished": "2025-06-21T05:31:08.158Z",
    "dateReserved": "2025-06-20T10:38:45.469Z",
    "dateUpdated": "2025-06-23T19:27:53.229Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-4851 (GCVE-0-2025-4851)

Vulnerability from nvd – Published: 2025-05-18 03:31 – Updated: 2025-05-19 14:28
VLAI?
Title
TOTOLINK N300RH cstecgi.cgi setUploadUserData command injection
Summary
A vulnerability classified as critical was found in TOTOLINK N300RH 6.1c.1390_B20191101. This vulnerability affects the function setUploadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
https://vuldb.com/?id.309322 vdb-entrytechnical-description
https://vuldb.com/?ctiid.309322 signaturepermissions-required
https://vuldb.com/?submit.575074 third-party-advisory
https://github.com/CH13hh/tmp_store_cc/blob/main/… broken-linkexploit
https://www.totolink.net/ product
Impacted products
Vendor Product Version
TOTOLINK N300RH Affected: 6.1c.1390_B20191101
Create a notification for this product.
Credits
DaddyShark (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-4851",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-19T14:28:49.457478Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-19T14:28:55.806Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "N300RH",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "6.1c.1390_B20191101"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "DaddyShark (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in TOTOLINK N300RH 6.1c.1390_B20191101. This vulnerability affects the function setUploadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In TOTOLINK N300RH 6.1c.1390_B20191101 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion setUploadUserData der Datei /cgi-bin/cstecgi.cgi. Mit der Manipulation des Arguments FileName mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-18T03:31:05.521Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-309322 | TOTOLINK N300RH cstecgi.cgi setUploadUserData command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.309322"
        },
        {
          "name": "VDB-309322 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.309322"
        },
        {
          "name": "Submit #575074 | TOTOLINK N300RH_V4 V6.1c.1390_B20191101 Command execution",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.575074"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://github.com/CH13hh/tmp_store_cc/blob/main/tt/ta/m3.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-05-16T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-05-16T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-05-16T17:21:58.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK N300RH cstecgi.cgi setUploadUserData command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-4851",
    "datePublished": "2025-05-18T03:31:05.521Z",
    "dateReserved": "2025-05-16T15:16:21.822Z",
    "dateUpdated": "2025-05-19T14:28:55.806Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-4850 (GCVE-0-2025-4850)

Vulnerability from nvd – Published: 2025-05-18 03:00 – Updated: 2025-05-19 14:29
VLAI?
Title
TOTOLINK N300RH cstecgi.cgi setUnloadUserData command injection
Summary
A vulnerability classified as critical has been found in TOTOLINK N300RH 6.1c.1390_B20191101. This affects the function setUnloadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument plugin_name leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
https://vuldb.com/?id.309321 vdb-entrytechnical-description
https://vuldb.com/?ctiid.309321 signaturepermissions-required
https://vuldb.com/?submit.575073 third-party-advisory
https://github.com/CH13hh/tmp_store_cc/blob/main/… broken-linkexploit
https://www.totolink.net/ product
Impacted products
Vendor Product Version
TOTOLINK N300RH Affected: 6.1c.1390_B20191101
Create a notification for this product.
Credits
DaddyShark (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-4850",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-19T14:29:32.930399Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-19T14:29:39.205Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "N300RH",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "6.1c.1390_B20191101"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "DaddyShark (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in TOTOLINK N300RH 6.1c.1390_B20191101. This affects the function setUnloadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument plugin_name leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in TOTOLINK N300RH 6.1c.1390_B20191101 entdeckt. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion setUnloadUserData der Datei /cgi-bin/cstecgi.cgi. Dank Manipulation des Arguments plugin_name mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-18T03:00:09.448Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-309321 | TOTOLINK N300RH cstecgi.cgi setUnloadUserData command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.309321"
        },
        {
          "name": "VDB-309321 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.309321"
        },
        {
          "name": "Submit #575073 | TOTOLINK N300RH_V4 V6.1c.1390_B20191101 Command execution",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.575073"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://github.com/CH13hh/tmp_store_cc/blob/main/tt/ta/m2.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-05-16T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-05-16T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-05-16T17:21:33.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK N300RH cstecgi.cgi setUnloadUserData command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-4850",
    "datePublished": "2025-05-18T03:00:09.448Z",
    "dateReserved": "2025-05-16T15:16:18.882Z",
    "dateUpdated": "2025-05-19T14:29:39.205Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-4849 (GCVE-0-2025-4849)

Vulnerability from nvd – Published: 2025-05-18 02:31 – Updated: 2025-05-19 14:33
VLAI?
Title
TOTOLINK N300RH cstecgi.cgi CloudACMunualUpdateUserdata command injection
Summary
A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been rated as critical. Affected by this issue is the function CloudACMunualUpdateUserdata of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument url leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
https://vuldb.com/?id.309320 vdb-entrytechnical-description
https://vuldb.com/?ctiid.309320 signaturepermissions-required
https://vuldb.com/?submit.575072 third-party-advisory
https://github.com/CH13hh/tmp_store_cc/blob/main/… broken-linkexploit
https://www.totolink.net/ product
Impacted products
Vendor Product Version
TOTOLINK N300RH Affected: 6.1c.1390_B20191101
Create a notification for this product.
Credits
DaddyShark (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-4849",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-19T14:33:13.441865Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-19T14:33:20.620Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "N300RH",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "6.1c.1390_B20191101"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "DaddyShark (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been rated as critical. Affected by this issue is the function CloudACMunualUpdateUserdata of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument url leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in TOTOLINK N300RH 6.1c.1390_B20191101 ausgemacht. Davon betroffen ist die Funktion CloudACMunualUpdateUserdata der Datei /cgi-bin/cstecgi.cgi. Dank der Manipulation des Arguments url mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-18T02:31:07.150Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-309320 | TOTOLINK N300RH cstecgi.cgi CloudACMunualUpdateUserdata command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.309320"
        },
        {
          "name": "VDB-309320 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.309320"
        },
        {
          "name": "Submit #575072 | TOTOLINK N300RH_V4 V6.1c.1390_B20191101 Command execution",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.575072"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://github.com/CH13hh/tmp_store_cc/blob/main/tt/ta/m1.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-05-16T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-05-16T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-05-16T17:21:31.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK N300RH cstecgi.cgi CloudACMunualUpdateUserdata command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-4849",
    "datePublished": "2025-05-18T02:31:07.150Z",
    "dateReserved": "2025-05-16T15:16:15.738Z",
    "dateUpdated": "2025-05-19T14:33:20.620Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-6401 (GCVE-0-2025-6401)

Vulnerability from cvelistv5 – Published: 2025-06-21 06:31 – Updated: 2025-06-23 19:27
VLAI?
Title
TOTOLINK N300RH HTTP POST Message formFilter denial of service
Summary
A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been classified as problematic. This affects an unknown part of the file /boafrm/formFilter of the component HTTP POST Message Handler. The manipulation of the argument url leads to denial of service. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
TOTOLINK N300RH Affected: 6.1c.1390_B20191101
Create a notification for this product.
Credits
yuhongxiang (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-6401",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-23T16:09:27.308682Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-23T19:27:48.226Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/d2pq/cve/blob/main/616/21.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP POST Message Handler"
          ],
          "product": "N300RH",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "6.1c.1390_B20191101"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yuhongxiang (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been classified as problematic. This affects an unknown part of the file /boafrm/formFilter of the component HTTP POST Message Handler. The manipulation of the argument url leads to denial of service. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in TOTOLINK N300RH 6.1c.1390_B20191101 ausgemacht. Sie wurde als problematisch eingestuft. Es betrifft eine unbekannte Funktion der Datei /boafrm/formFilter der Komponente HTTP POST Message Handler. Mittels dem Manipulieren des Arguments url mit unbekannten Daten kann eine denial of service-Schwachstelle ausgenutzt werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 2.3,
            "vectorString": "AV:A/AC:M/Au:S/C:N/I:N/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-404",
              "description": "Denial of Service",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-21T06:31:08.227Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-313395 | TOTOLINK N300RH HTTP POST Message formFilter denial of service",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.313395"
        },
        {
          "name": "VDB-313395 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.313395"
        },
        {
          "name": "Submit #597688 | TOTOLINK  N300RH_V4 V6.1c.1390_B20191101 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.597688"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/d2pq/cve/blob/main/616/21.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/d2pq/cve/blob/main/616/21.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-20T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-20T12:43:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK N300RH HTTP POST Message formFilter denial of service"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-6401",
    "datePublished": "2025-06-21T06:31:08.227Z",
    "dateReserved": "2025-06-20T10:38:48.055Z",
    "dateUpdated": "2025-06-23T19:27:48.226Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-6400 (GCVE-0-2025-6400)

Vulnerability from cvelistv5 – Published: 2025-06-21 05:31 – Updated: 2025-06-23 19:27
VLAI?
Title
TOTOLINK N300RH HTTP POST Message formPortFw buffer overflow
Summary
A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101 and classified as critical. Affected by this issue is some unknown functionality of the file /boafrm/formPortFw of the component HTTP POST Message Handler. The manipulation of the argument service_type leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
TOTOLINK N300RH Affected: 6.1c.1390_B20191101
Create a notification for this product.
Credits
yuhongxiang (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-6400",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-23T16:09:32.157775Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-23T19:27:53.229Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/d2pq/cve/blob/main/616/20.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP POST Message Handler"
          ],
          "product": "N300RH",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "6.1c.1390_B20191101"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yuhongxiang (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101 and classified as critical. Affected by this issue is some unknown functionality of the file /boafrm/formPortFw of the component HTTP POST Message Handler. The manipulation of the argument service_type leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in TOTOLINK N300RH 6.1c.1390_B20191101 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um eine nicht exakt ausgemachte Funktion der Datei /boafrm/formPortFw der Komponente HTTP POST Message Handler. Durch Manipulation des Arguments service_type mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-21T05:31:08.158Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-313394 | TOTOLINK N300RH HTTP POST Message formPortFw buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.313394"
        },
        {
          "name": "VDB-313394 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.313394"
        },
        {
          "name": "Submit #597687 | TOTOLINK N300RH_V4 V6.1c.1390_B20191101 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.597687"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/d2pq/cve/blob/main/616/20.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/d2pq/cve/blob/main/616/20.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-20T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-20T12:43:52.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK N300RH HTTP POST Message formPortFw buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-6400",
    "datePublished": "2025-06-21T05:31:08.158Z",
    "dateReserved": "2025-06-20T10:38:45.469Z",
    "dateUpdated": "2025-06-23T19:27:53.229Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-4851 (GCVE-0-2025-4851)

Vulnerability from cvelistv5 – Published: 2025-05-18 03:31 – Updated: 2025-05-19 14:28
VLAI?
Title
TOTOLINK N300RH cstecgi.cgi setUploadUserData command injection
Summary
A vulnerability classified as critical was found in TOTOLINK N300RH 6.1c.1390_B20191101. This vulnerability affects the function setUploadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
https://vuldb.com/?id.309322 vdb-entrytechnical-description
https://vuldb.com/?ctiid.309322 signaturepermissions-required
https://vuldb.com/?submit.575074 third-party-advisory
https://github.com/CH13hh/tmp_store_cc/blob/main/… broken-linkexploit
https://www.totolink.net/ product
Impacted products
Vendor Product Version
TOTOLINK N300RH Affected: 6.1c.1390_B20191101
Create a notification for this product.
Credits
DaddyShark (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-4851",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-19T14:28:49.457478Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-19T14:28:55.806Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "N300RH",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "6.1c.1390_B20191101"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "DaddyShark (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in TOTOLINK N300RH 6.1c.1390_B20191101. This vulnerability affects the function setUploadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In TOTOLINK N300RH 6.1c.1390_B20191101 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion setUploadUserData der Datei /cgi-bin/cstecgi.cgi. Mit der Manipulation des Arguments FileName mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-18T03:31:05.521Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-309322 | TOTOLINK N300RH cstecgi.cgi setUploadUserData command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.309322"
        },
        {
          "name": "VDB-309322 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.309322"
        },
        {
          "name": "Submit #575074 | TOTOLINK N300RH_V4 V6.1c.1390_B20191101 Command execution",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.575074"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://github.com/CH13hh/tmp_store_cc/blob/main/tt/ta/m3.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-05-16T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-05-16T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-05-16T17:21:58.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK N300RH cstecgi.cgi setUploadUserData command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-4851",
    "datePublished": "2025-05-18T03:31:05.521Z",
    "dateReserved": "2025-05-16T15:16:21.822Z",
    "dateUpdated": "2025-05-19T14:28:55.806Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-4850 (GCVE-0-2025-4850)

Vulnerability from cvelistv5 – Published: 2025-05-18 03:00 – Updated: 2025-05-19 14:29
VLAI?
Title
TOTOLINK N300RH cstecgi.cgi setUnloadUserData command injection
Summary
A vulnerability classified as critical has been found in TOTOLINK N300RH 6.1c.1390_B20191101. This affects the function setUnloadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument plugin_name leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
https://vuldb.com/?id.309321 vdb-entrytechnical-description
https://vuldb.com/?ctiid.309321 signaturepermissions-required
https://vuldb.com/?submit.575073 third-party-advisory
https://github.com/CH13hh/tmp_store_cc/blob/main/… broken-linkexploit
https://www.totolink.net/ product
Impacted products
Vendor Product Version
TOTOLINK N300RH Affected: 6.1c.1390_B20191101
Create a notification for this product.
Credits
DaddyShark (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-4850",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-19T14:29:32.930399Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-19T14:29:39.205Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "N300RH",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "6.1c.1390_B20191101"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "DaddyShark (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in TOTOLINK N300RH 6.1c.1390_B20191101. This affects the function setUnloadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument plugin_name leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in TOTOLINK N300RH 6.1c.1390_B20191101 entdeckt. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion setUnloadUserData der Datei /cgi-bin/cstecgi.cgi. Dank Manipulation des Arguments plugin_name mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-18T03:00:09.448Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-309321 | TOTOLINK N300RH cstecgi.cgi setUnloadUserData command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.309321"
        },
        {
          "name": "VDB-309321 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.309321"
        },
        {
          "name": "Submit #575073 | TOTOLINK N300RH_V4 V6.1c.1390_B20191101 Command execution",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.575073"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://github.com/CH13hh/tmp_store_cc/blob/main/tt/ta/m2.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-05-16T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-05-16T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-05-16T17:21:33.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK N300RH cstecgi.cgi setUnloadUserData command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-4850",
    "datePublished": "2025-05-18T03:00:09.448Z",
    "dateReserved": "2025-05-16T15:16:18.882Z",
    "dateUpdated": "2025-05-19T14:29:39.205Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-4849 (GCVE-0-2025-4849)

Vulnerability from cvelistv5 – Published: 2025-05-18 02:31 – Updated: 2025-05-19 14:33
VLAI?
Title
TOTOLINK N300RH cstecgi.cgi CloudACMunualUpdateUserdata command injection
Summary
A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been rated as critical. Affected by this issue is the function CloudACMunualUpdateUserdata of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument url leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
https://vuldb.com/?id.309320 vdb-entrytechnical-description
https://vuldb.com/?ctiid.309320 signaturepermissions-required
https://vuldb.com/?submit.575072 third-party-advisory
https://github.com/CH13hh/tmp_store_cc/blob/main/… broken-linkexploit
https://www.totolink.net/ product
Impacted products
Vendor Product Version
TOTOLINK N300RH Affected: 6.1c.1390_B20191101
Create a notification for this product.
Credits
DaddyShark (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-4849",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-19T14:33:13.441865Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-19T14:33:20.620Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "N300RH",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "6.1c.1390_B20191101"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "DaddyShark (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been rated as critical. Affected by this issue is the function CloudACMunualUpdateUserdata of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument url leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in TOTOLINK N300RH 6.1c.1390_B20191101 ausgemacht. Davon betroffen ist die Funktion CloudACMunualUpdateUserdata der Datei /cgi-bin/cstecgi.cgi. Dank der Manipulation des Arguments url mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-18T02:31:07.150Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-309320 | TOTOLINK N300RH cstecgi.cgi CloudACMunualUpdateUserdata command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.309320"
        },
        {
          "name": "VDB-309320 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.309320"
        },
        {
          "name": "Submit #575072 | TOTOLINK N300RH_V4 V6.1c.1390_B20191101 Command execution",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.575072"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://github.com/CH13hh/tmp_store_cc/blob/main/tt/ta/m1.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-05-16T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-05-16T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-05-16T17:21:31.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK N300RH cstecgi.cgi CloudACMunualUpdateUserdata command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-4849",
    "datePublished": "2025-05-18T02:31:07.150Z",
    "dateReserved": "2025-05-16T15:16:15.738Z",
    "dateUpdated": "2025-05-19T14:33:20.620Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}