Search

Find a vulnerability

Search criteria

    116 vulnerabilities found for mbconnect24 by mbconnectline

    FKIE_CVE-2026-33614

    Vulnerability from fkie_nvd - Published: 2026-04-02 10:16 - Updated: 2026-10-26 21:10
    Summary
    An unauthenticated remote attacker can exploit an unauthenticated SQL Injection vulnerability in the getinfo endpoint due to improper neutralization of special elements in a SQL SELECT command. This can result in a total loss of confidentiality.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.19.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.19.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FF88F461-51FB-482C-A406-07F72FC10D79",
                  "versionEndIncluding": "2.19.4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "36E8693F-94C4-46A4-BD83-D87B71B89F12",
                  "versionEndIncluding": "2.19.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated remote attacker can exploit an unauthenticated SQL Injection vulnerability in the getinfo endpoint due to improper neutralization of special elements in a SQL SELECT command. This can result in a total loss of confidentiality."
        },
        {
          "lang": "es",
          "value": "Un atacante remoto no autenticado puede explotar una vulnerabilidad de inyecci\u00f3n SQL no autenticada en el endpoint getinfo debido a la neutralizaci\u00f3n inadecuada de elementos especiales en un comando SQL SELECT. Esto puede resultar en una p\u00e9rdida total de confidencialidad."
        }
      ],
      "id": "CVE-2026-33614",
      "lastModified": "2026-10-26T21:10:00.170",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-33614",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-04-02T13:29:54.050449Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-04-02T10:16:16.723",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://certvde.com/de/advisories/VDE-2026-030"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-030.json"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-89"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-33615

    Vulnerability from fkie_nvd - Published: 2026-04-02 10:16 - Updated: 2026-10-26 21:10
    Summary
    An unauthenticated remote attacker can exploit an unauthenticated SQL Injection vulnerability in the setinfo endpoint due to improper neutralization of special elements in a SQL UPDATE command. This can result in a total loss of integrity and availability.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.19.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.19.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FF88F461-51FB-482C-A406-07F72FC10D79",
                  "versionEndIncluding": "2.19.4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "36E8693F-94C4-46A4-BD83-D87B71B89F12",
                  "versionEndIncluding": "2.19.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated remote attacker can exploit an unauthenticated SQL Injection vulnerability in the setinfo endpoint due to improper neutralization of special elements in a SQL UPDATE command. This can result in a total loss of integrity and availability."
        },
        {
          "lang": "es",
          "value": "Un atacante remoto no autenticado puede explotar una vulnerabilidad de inyecci\u00f3n SQL no autenticada en el endpoint setinfo debido a la neutralizaci\u00f3n inadecuada de elementos especiales en un comando SQL UPDATE. Esto puede resultar en una p\u00e9rdida total de integridad y disponibilidad."
        }
      ],
      "id": "CVE-2026-33615",
      "lastModified": "2026-10-26T21:10:00.170",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.1,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.2,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-33615",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-04-02T14:29:33.756162Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-04-02T10:16:16.910",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://certvde.com/de/advisories/VDE-2026-030"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-030.json"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-89"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-33617

    Vulnerability from fkie_nvd - Published: 2026-04-02 10:16 - Updated: 2026-10-26 21:10
    Summary
    An unauthenticated remote attacker can access a configuration file containing database credentials. This can result in a some loss of confidentiality, but there is no endpoint exposed to use these credentials.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.19.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.19.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FF88F461-51FB-482C-A406-07F72FC10D79",
                  "versionEndIncluding": "2.19.4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "36E8693F-94C4-46A4-BD83-D87B71B89F12",
                  "versionEndIncluding": "2.19.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated remote attacker can access a configuration file containing database credentials. This can result in a some loss of confidentiality, but there is no endpoint exposed to use these credentials."
        },
        {
          "lang": "es",
          "value": "Un atacante remoto no autenticado puede acceder a un archivo de configuraci\u00f3n que contiene credenciales de la base de datos. Esto puede resultar en cierta p\u00e9rdida de confidencialidad, pero no hay ning\u00fan endpoint expuesto para usar estas credenciales."
        }
      ],
      "id": "CVE-2026-33617",
      "lastModified": "2026-10-26T21:10:00.170",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-33617",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-04-03T17:21:45.412589Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-04-02T10:16:17.260",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://certvde.com/de/advisories/VDE-2026-030"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-030.json"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-497"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-33613

    Vulnerability from fkie_nvd - Published: 2026-04-02 10:16 - Updated: 2026-10-26 21:10
    Summary
    Due to the improper neutralisation of special elements used in an OS command, a remote attacker can exploit an RCE vulnerability in the generateSrpArray function, resulting in full system compromise. This vulnerability can only be attacked if the attacker has some other way to write arbitrary data to the user table.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.19.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.19.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FF88F461-51FB-482C-A406-07F72FC10D79",
                  "versionEndIncluding": "2.19.4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "36E8693F-94C4-46A4-BD83-D87B71B89F12",
                  "versionEndIncluding": "2.19.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Due to the improper neutralisation of special elements used in an OS command, a remote attacker can exploit an RCE vulnerability in the generateSrpArray function, resulting in full system compromise.\nThis vulnerability can only be attacked if the attacker has some other way to write arbitrary data to the user table."
        },
        {
          "lang": "es",
          "value": "Debido a la neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando del sistema operativo, un atacante remoto puede explotar una vulnerabilidad RCE en la funci\u00f3n generateSrpArray, lo que resulta en un compromiso total del sistema.\nEsta vulnerabilidad solo puede ser atacada si el atacante tiene alguna otra forma de escribir datos arbitrarios en la tabla de usuarios."
        }
      ],
      "id": "CVE-2026-33613",
      "lastModified": "2026-10-26T21:10:00.170",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.2,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.2,
            "impactScore": 5.9,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-33613",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-04-02T13:41:33.794559Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-04-02T10:16:15.727",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://certvde.com/de/advisories/VDE-2026-030"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-030.json"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-78"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-33616

    Vulnerability from fkie_nvd - Published: 2026-04-02 10:16 - Updated: 2026-10-25 23:10
    Summary
    An unauthenticated remote attacker can exploit an unauthenticated blind SQL Injection vulnerability in the mb24api endpoint due to improper neutralization of special elements in a SQL SELECT command. This can result in a total loss of confidentiality.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.19.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.19.4",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FF88F461-51FB-482C-A406-07F72FC10D79",
                  "versionEndIncluding": "2.19.4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "36E8693F-94C4-46A4-BD83-D87B71B89F12",
                  "versionEndIncluding": "2.19.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated remote attacker can exploit an unauthenticated blind SQL Injection vulnerability in the mb24api endpoint due to improper neutralization of special elements in a SQL SELECT command. This can result in a total loss of confidentiality."
        },
        {
          "lang": "es",
          "value": "Un atacante remoto no autenticado puede explotar una vulnerabilidad de inyecci\u00f3n SQL ciega no autenticada en el endpoint mb24api debido a la neutralizaci\u00f3n incorrecta de elementos especiales en un comando SQL SELECT. Esto puede resultar en una p\u00e9rdida total de confidencialidad."
        }
      ],
      "id": "CVE-2026-33616",
      "lastModified": "2026-10-25T23:10:00.167",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-33616",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-04-02T13:08:03.527993Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-04-02T10:16:17.080",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://certvde.com/de/advisories/VDE-2026-030"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-030.json"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-89"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2024-45273

    Vulnerability from fkie_nvd - Published: 2024-10-15 11:15 - Updated: 2026-06-17 07:53
    Summary
    An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "mbNET.mini",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET/mbNET.rokey",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "8.2.0",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbNET HW1",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "5.1.11",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbSPIDER",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.6.5",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX100",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.2.13",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX200/250",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 8.2.0",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24 V2",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "REX300",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "\u003c= 5.1.11",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "mbnet.mini",
              "vendor": "mb_connect_line",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "mbnet_mbnet.rokey",
              "vendor": "mbconnectline",
              "versions": [
                {
                  "lessThanOrEqual": "8.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "mbnet_hw1",
              "vendor": "mbconnectline",
              "versions": [
                {
                  "lessThanOrEqual": "5.1.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "mbspider",
              "vendor": "mbconnectline",
              "versions": [
                {
                  "lessThanOrEqual": "2.6.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "mbconnect24",
              "vendor": "mbconnectline",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "mymbconnect24",
              "vendor": "mbconnectline",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "rex100",
              "vendor": "helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "rex_200",
              "vendor": "helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "8.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "rex250",
              "vendor": "helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "8.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "myrex24_v2",
              "vendor": "helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "myrex24.virtual",
              "vendor": "helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "rex300",
              "vendor": "helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "5.1.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbnet.mini_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E4E80D53-0907-45AF-A03B-A093C5CEA33B",
                  "versionEndExcluding": "2.3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbnet.mini:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A1D1B769-DA91-4F0C-AD34-D735B7A8B8FF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24_v2_virtual_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5D5B73E2-38BA-415D-96AF-D0F835E3C9BC",
                  "versionEndExcluding": "2.16.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:helmholz:rex_300_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "05CB17C2-1B86-41AA-8737-718BA9464BB0",
                  "versionEndIncluding": "5.1.11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:helmholz:rex_300:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB65F958-3FF4-48A7-8007-406A7FDBA0E7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:helmholz:rex_200_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EE10F9E9-A0EE-4CF1-9F4B-6AF4179ED03E",
                  "versionEndExcluding": "8.2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "28B3785D-8EFF-4A67-88F1-8F9D0EC39D6C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:helmholz:rex_250_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "67ECB608-F99D-479C-95CC-349DCB530D98",
                  "versionEndExcluding": "8.2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:helmholz:rex_250:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "53454815-3E7A-4097-8FC7-2F7634DAF7E1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F226166A-1261-43F9-81EC-E1C0FC9CB6E6",
                  "versionEndExcluding": "2.3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:helmholz:rex_100:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7E8BE39-3C4A-484A-A34D-3CB4B46E41FA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9F017673-3A54-4D92-811F-AE395CCED7CF",
                  "versionEndExcluding": "2.16.3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "18BC8E52-E277-4D72-903A-A31FC658B6E2",
                  "versionEndExcluding": "2.16.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbspider_mdh_905_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "188A4550-AE25-459E-9624-97090842230B",
                  "versionEndIncluding": "2.6.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbspider_mdh_905:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5ABBF6FE-BF26-43B2-B54C-6ECE4234B3C9",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbspider_mdh_915_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CAEA6C5-27F5-4BA5-BEB4-DD2EDE66F877",
                  "versionEndIncluding": "2.6.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbspider_mdh_915:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ED665544-6D67-465A-8850-6FD7A44D9E6F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbspider_mdh_906_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E41557B9-9BE2-4286-A1FE-88CDAD14B824",
                  "versionEndIncluding": "2.6.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbspider_mdh_906:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "63B499C3-0C59-488D-89E7-2CBEEA42E1E9",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbspider_mdh_916_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "75321482-BFC4-4D37-AF03-9212AE6028A7",
                  "versionEndIncluding": "2.6.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbspider_mdh_916:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B74973FF-4DC9-4076-A161-28EC0A5F5E6D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbnet_hw1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7470E3A2-72C5-4743-ABC2-14FB4C9F02D8",
                  "versionEndIncluding": "5.1.11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbnet_hw1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "83E49632-8868-4BF8-A86D-E7F10130B378",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbnet_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "40166B67-481E-4B36-BBD8-4F5721B75B9E",
                  "versionEndExcluding": "8.2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbnet:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4D8CB051-1E1A-4014-9FB2-4473AC4CEE30",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbnet.rokey_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2AE59454-A9F9-44BE-8B06-9A631332A4E9",
                  "versionEndExcluding": "8.2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbnet.rokey:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CC7B6E4C-1AC2-4CD8-A056-2EF8845622CA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used."
        },
        {
          "lang": "es",
          "value": "Un atacante local no autenticado puede descifrar el archivo de configuraci\u00f3n del dispositivo y, por lo tanto, comprometer el dispositivo debido a una implementaci\u00f3n d\u00e9bil del cifrado utilizado."
        }
      ],
      "id": "CVE-2024-45273",
      "lastModified": "2026-06-17T07:53:55.560",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 8.4,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.5,
            "impactScore": 5.9,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2024-45273",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-10-15T18:22:26.955543Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-10-15T11:15:11.940",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2024-056"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2024-066"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2024-068"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2024-069"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-062.txt"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-261"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-326"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2024-45272

    Vulnerability from fkie_nvd - Published: 2024-10-15 11:15 - Updated: 2026-06-17 07:53

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24 V2",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "mbconnect24",
              "vendor": "mbconnectline",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "mymbconnect24",
              "vendor": "mbconnectline",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "myrex24_v2",
              "vendor": "helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unaffected",
              "product": "myrex24.virtual",
              "vendor": "helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.16.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24_v2_virtual_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5D5B73E2-38BA-415D-96AF-D0F835E3C9BC",
                  "versionEndExcluding": "2.16.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:helmholz:rex_300_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "05CB17C2-1B86-41AA-8737-718BA9464BB0",
                  "versionEndIncluding": "5.1.11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:helmholz:rex_300:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB65F958-3FF4-48A7-8007-406A7FDBA0E7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:helmholz:rex_200_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EE10F9E9-A0EE-4CF1-9F4B-6AF4179ED03E",
                  "versionEndExcluding": "8.2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "28B3785D-8EFF-4A67-88F1-8F9D0EC39D6C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:helmholz:rex_250_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "67ECB608-F99D-479C-95CC-349DCB530D98",
                  "versionEndExcluding": "8.2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:helmholz:rex_250:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "53454815-3E7A-4097-8FC7-2F7634DAF7E1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9F017673-3A54-4D92-811F-AE395CCED7CF",
                  "versionEndExcluding": "2.16.3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "18BC8E52-E277-4D72-903A-A31FC658B6E2",
                  "versionEndExcluding": "2.16.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbspider_mdh_905_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "188A4550-AE25-459E-9624-97090842230B",
                  "versionEndIncluding": "2.6.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbspider_mdh_905:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5ABBF6FE-BF26-43B2-B54C-6ECE4234B3C9",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbspider_mdh_915_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CAEA6C5-27F5-4BA5-BEB4-DD2EDE66F877",
                  "versionEndIncluding": "2.6.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbspider_mdh_915:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ED665544-6D67-465A-8850-6FD7A44D9E6F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbspider_mdh_906_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E41557B9-9BE2-4286-A1FE-88CDAD14B824",
                  "versionEndIncluding": "2.6.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbspider_mdh_906:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "63B499C3-0C59-488D-89E7-2CBEEA42E1E9",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbspider_mdh_916_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "75321482-BFC4-4D37-AF03-9212AE6028A7",
                  "versionEndIncluding": "2.6.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbspider_mdh_916:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B74973FF-4DC9-4076-A161-28EC0A5F5E6D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbnet_hw1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7470E3A2-72C5-4743-ABC2-14FB4C9F02D8",
                  "versionEndIncluding": "5.1.11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbnet_hw1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "83E49632-8868-4BF8-A86D-E7F10130B378",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbnet_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "40166B67-481E-4B36-BBD8-4F5721B75B9E",
                  "versionEndExcluding": "8.2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbnet:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4D8CB051-1E1A-4014-9FB2-4473AC4CEE30",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mbconnectline:mbnet.rokey_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2AE59454-A9F9-44BE-8B06-9A631332A4E9",
                  "versionEndExcluding": "8.2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mbconnectline:mbnet.rokey:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CC7B6E4C-1AC2-4CD8-A056-2EF8845622CA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated remote attacker can perform a brute-force attack on the credentials of the remote service portal with a high chance of success, resulting in connection lost."
        },
        {
          "lang": "es",
          "value": "Un atacante remoto no autenticado puede realizar un ataque de fuerza bruta a las credenciales del portal de servicio remoto con una alta probabilidad de \u00e9xito, lo que da como resultado la p\u00e9rdida de la conexi\u00f3n."
        }
      ],
      "id": "CVE-2024-45272",
      "lastModified": "2026-06-17T07:53:55.420",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2024-45272",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-10-15T13:40:14.338031Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-10-15T11:15:11.673",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2024-068"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2024-069"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-061.txt"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-1391"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-Other"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-4834

    Vulnerability from fkie_nvd - Published: 2023-10-16 09:15 - Updated: 2026-06-17 06:38
    Summary
    In Red Lion Europe mbCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an improperly implemented access validation allows an authenticated, low privileged attacker to gain read access to limited, non-critical device information in his account he should not have access to.

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "Red Lion Europe",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "Red Lion Europe",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.14.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6B75F1E4-3DFA-4163-A9C7-8CF5C9A78562",
                  "versionEndIncluding": "2.14.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "885E9E11-89FE-468F-8160-EC3B21E6CA77",
                  "versionEndIncluding": "2.14.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2029F9FB-397A-490D-A86F-B2B39C516A79",
                  "versionEndIncluding": "2.14.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F77AC2B-5B57-4CFF-A4F1-AA8E6B1B8C3B",
                  "versionEndIncluding": "2.14.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Red Lion Europe\u00a0mbCONNECT24 and mymbCONNECT24 and Helmholz myREX24 and myREX24.virtual up to and including 2.14.2 an\u00a0improperly implemented access validation allows an authenticated, low privileged\u00a0attacker to gain read access to limited, non-critical device information in his account he should not have access to.\n\n\n\n\t\t\t\t\t\n\n\n\t\t\t\t\n\n\n\t\t\t\n\n\n\t\t\n\n\n\t\n"
        },
        {
          "lang": "es",
          "value": "En Red Lion Europe mbCONNECT24 y mymbCONNECT24 y Helmholz myREX24 y myREX24.virtual hasta la versi\u00f3n 2.14.2 incluida, una validaci\u00f3n de acceso implementada incorrectamente permite a un atacante autenticado y con pocos privilegios obtener acceso de lectura a informaci\u00f3n limitada y no cr\u00edtica del dispositivo a la que no deber\u00eda tener acceso en su cuenta."
        }
      ],
      "id": "CVE-2023-4834",
      "lastModified": "2026-06-17T06:38:42.783",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-4834",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-09-16T18:16:53.810599Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-10-16T09:15:11.830",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2023-041"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2023-043"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2023-041"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2023-043"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-269"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-1779

    Vulnerability from fkie_nvd - Published: 2023-06-06 11:15 - Updated: 2026-06-17 05:28
    Summary
    Exposure of Sensitive Information to an unauthorized actor vulnerability in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz' myREX24 and myREX24.virtual in versions <=2.13.3 allow an authorized remote attacker with low privileges to view a limited amount of another accounts contact information.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB Connect Line",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB Connect Line",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6CC21EC6-52DA-47D9-AC27-9D1707B71467",
                  "versionEndIncluding": "2.13.3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "70123597-DE04-4807-952D-F9CFC9805A34",
                  "versionEndIncluding": "2.13.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Exposure of Sensitive Information to an unauthorized actor vulnerability\u00a0in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual in versions \u003c=2.13.3 allow an authorized remote attacker with low privileges to view a limited amount of another accounts contact information."
        }
      ],
      "id": "CVE-2023-1779",
      "lastModified": "2026-06-17T05:28:44.380",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-1779",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-01-07T19:17:38.403913Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-06-06T11:15:09.913",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2023-008/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2023-008/"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-863"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-0985

    Vulnerability from fkie_nvd - Published: 2023-06-06 11:15 - Updated: 2026-06-17 05:26
    Summary
    An Authorization Bypass vulnerability was found in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz' myREX24 and myREX24.virtual version <= 2.13.3. An authenticated remote user with low privileges can change the password of any user in the same account. This allows to take over the admin user and therefore fully compromise the account.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB Connect Line",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB Connect Line",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.13.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6CC21EC6-52DA-47D9-AC27-9D1707B71467",
                  "versionEndIncluding": "2.13.3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "70123597-DE04-4807-952D-F9CFC9805A34",
                  "versionEndIncluding": "2.13.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An Authorization Bypass vulnerability was found in MB Connect Lines\u00a0mbCONNECT24, mymbCONNECT24 and Helmholz\u0027 myREX24 and myREX24.virtual version \u003c= 2.13.3.\u00a0An authenticated remote user with low privileges can change the password of any user in the same account. This allows to take over the admin user and therefore fully compromise the account."
        }
      ],
      "id": "CVE-2023-0985",
      "lastModified": "2026-06-17T05:26:49.770",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-0985",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-01-07T19:19:39.189272Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-06-06T11:15:09.093",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Mitigation",
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2023-002/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mitigation",
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2023-002/"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-639"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2022-22520

    Vulnerability from fkie_nvd - Published: 2022-09-14 14:15 - Updated: 2026-06-17 04:28
    Summary
    A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote, unauthenticated attacker can enumerate valid users by sending specific requests to the webservice of MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2."
        },
        {
          "lang": "es",
          "value": "Un atacante remoto no autenticado puede enumerar usuarios v\u00e1lidos mediante el env\u00edo de peticiones espec\u00edficas al webservice de la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta v2.11.2"
        }
      ],
      "id": "CVE-2022-22520",
      "lastModified": "2026-06-17T04:28:31.333",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      },
      "published": "2022-09-14T14:15:12.427",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Not Applicable"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-011"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Not Applicable"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-204"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-34580

    Vulnerability from fkie_nvd - Published: 2021-10-27 11:15 - Updated: 2026-06-17 03:56
    Summary
    In mymbCONNECT24, mbCONNECT24 <= 2.9.0 an unauthenticated user can enumerate valid backend users by checking what kind of response the server sends for crafted invalid login attempts.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.9.0",
                  "status": "affected",
                  "version": "2.9.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.9.0",
                  "status": "affected",
                  "version": "2.9.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C6FA138E-7298-488C-91CB-27A3AE49AA3C",
                  "versionEndIncluding": "2.9.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6149BB15-4765-4412-A071-C7880A52E3B3",
                  "versionEndIncluding": "2.9.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In mymbCONNECT24, mbCONNECT24 \u003c= 2.9.0 an unauthenticated user can enumerate valid backend users by checking what kind of response the server sends for crafted invalid login attempts."
        },
        {
          "lang": "es",
          "value": "En mymbCONNECT24, mbCONNECT24 versiones anteriores a 2.9.0 incluy\u00e9ndola, un usuario no autenticado puede enumerar los usuarios v\u00e1lidos del backend al comprobar qu\u00e9 tipo de respuesta env\u00eda el servidor para los intentos de inicio de sesi\u00f3n no v\u00e1lidos dise\u00f1ados"
        }
      ],
      "id": "CVE-2021-34580",
      "lastModified": "2026-06-17T03:56:10.077",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-10-27T11:15:07.553",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-037/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-037/"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-204"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-203"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-34575

    Vulnerability from fkie_nvd - Published: 2021-08-02 11:15 - Updated: 2026-06-17 03:56
    Summary
    In MB connect line mymbCONNECT24, mbCONNECT24 in versions <= 2.8.0 an unauthenticated user can enumerate valid users by checking what kind of response the server sends.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.8.0",
                  "status": "affected",
                  "version": "2.8.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.8.0",
                  "status": "affected",
                  "version": "2.8.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CDED8162-6FEE-4FDD-BFFC-93DDCE1CA011",
                  "versionEndIncluding": "2.8.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "29848C2B-8AE1-4D89-B9C6-A586C591D40A",
                  "versionEndIncluding": "2.8.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In MB connect line mymbCONNECT24, mbCONNECT24 in versions \u003c= 2.8.0 an unauthenticated user can enumerate valid users by checking what kind of response the server sends."
        },
        {
          "lang": "es",
          "value": "En MB connect line mymbCONNECT24, mbCONNECT24 versiones anteriores a 2.8.0 incluy\u00e9ndolas, un usuario no autenticado puede enumerar usuarios v\u00e1lidos al comprobar qu\u00e9 tipo de respuesta env\u00eda el servidor"
        }
      ],
      "id": "CVE-2021-34575",
      "lastModified": "2026-06-17T03:56:09.490",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-08-02T11:15:11.417",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-030"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-030"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-203"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-203"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-34574

    Vulnerability from fkie_nvd - Published: 2021-08-02 11:15 - Updated: 2026-06-17 03:56
    Summary
    In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "myREX24.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.11.2",
                  "status": "affected",
                  "version": "2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server."
        },
        {
          "lang": "es",
          "value": "En MB connect line mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta la v2.11.2 un atacante autenticado puede cambiar la contrase\u00f1a de su cuenta por una nueva que viole la pol\u00edtica de contrase\u00f1as interceptando y modificando la petici\u00f3n que se env\u00eda al servidor."
        }
      ],
      "id": "CVE-2021-34574",
      "lastModified": "2026-06-17T03:56:09.380",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      },
      "published": "2021-08-02T11:15:11.350",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
        },
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-030"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-669"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-669"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2020-35570

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual through 2.11.2. An unauthenticated attacker is able to access files (that should have been restricted) via forceful browsing.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual through 2.11.2. An unauthenticated attacker is able to access files (that should have been restricted) via forceful browsing."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual hasta la versi\u00f3n 2.11.2. Un atacante no autenticado es capaz de acceder a archivos (que deber\u00edan haber sido restringidos) a trav\u00e9s de la navegaci\u00f3n forzada."
        }
      ],
      "id": "CVE-2020-35570",
      "lastModified": "2026-06-17T03:13:57.467",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "cve@mitre.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.830",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-425"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35569

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. There is a self XSS issue with a crafted cookie in the login page.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD64D150-3FCD-4973-88EB-FDCBBC39BB4C",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FDA4DEB0-F344-4B04-8BFD-1D405D0CED23",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. There is a self XSS issue with a crafted cookie in the login page."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.2.\u0026#xa0;Se presenta un problema de tipo auto XSS con una cookie dise\u00f1ada en la p\u00e1gina de inicio de sesi\u00f3n"
        }
      ],
      "id": "CVE-2020-35569",
      "lastModified": "2026-06-17T03:13:57.347",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 2.7,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.767",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-79"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35568

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An incomplete filter applied to a database response allows an authenticated attacker to gain non-public information about other users and devices in the account.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An incomplete filter applied to a database response allows an authenticated attacker to gain non-public information about other users and devices in the account."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta la v2.11.2. Un filtro incompleto aplicado a una respuesta de la base de datos permite a un atacante autenticado obtener informaci\u00f3n no p\u00fablica sobre otros usuarios y dispositivos de la cuenta.\n"
        }
      ],
      "id": "CVE-2020-35568",
      "lastModified": "2026-06-17T03:13:57.210",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "cve@mitre.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.707",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-200"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35567

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. The software uses a secure password for database access, but this password is shared across instances.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD64D150-3FCD-4973-88EB-FDCBBC39BB4C",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FDA4DEB0-F344-4B04-8BFD-1D405D0CED23",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. The software uses a secure password for database access, but this password is shared across instances."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.2.\u0026#xa0;El software usa una contrase\u00f1a segura para el acceso a la base de datos, pero esta contrase\u00f1a es compartida entre instancias"
        }
      ],
      "id": "CVE-2020-35567",
      "lastModified": "2026-06-17T03:13:57.090",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.6,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.627",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-798"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35566

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An attacker can read arbitrary JSON files via Local File Inclusion.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. An attacker can read arbitrary JSON files via Local File Inclusion."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta la v2.11.2. Un atacante puede leer archivos JSON arbitrarios a trav\u00e9s de la inclusi\u00f3n de archivos locales."
        }
      ],
      "id": "CVE-2020-35566",
      "lastModified": "2026-06-17T03:13:56.963",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "cve@mitre.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.567",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-706"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35565

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. The login pages bruteforce detection is disabled by default.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD64D150-3FCD-4973-88EB-FDCBBC39BB4C",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FDA4DEB0-F344-4B04-8BFD-1D405D0CED23",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. The login pages bruteforce detection is disabled by default."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.2.\u0026#xa0;La detecci\u00f3n de fuerza bruta de las p\u00e1ginas de inicio de sesi\u00f3n est\u00e1 deshabilitada por defecto"
        }
      ],
      "id": "CVE-2020-35565",
      "lastModified": "2026-06-17T03:13:56.847",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.503",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-307"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35564

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. There is an outdated and unused component allowing for malicious user input of active code.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD64D150-3FCD-4973-88EB-FDCBBC39BB4C",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FDA4DEB0-F344-4B04-8BFD-1D405D0CED23",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. There is an outdated and unused component allowing for malicious user input of active code."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.2.\u0026#xa0;Existe un componente obsoleto y sin uso que permite la entrada de c\u00f3digo activo por parte de usuarios maliciosos"
        }
      ],
      "id": "CVE-2020-35564",
      "lastModified": "2026-06-17T03:13:56.730",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.427",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-74"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35563

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. There is an incomplete XSS filter allowing an attacker to inject crafted malicious code into the page.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD64D150-3FCD-4973-88EB-FDCBBC39BB4C",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FDA4DEB0-F344-4B04-8BFD-1D405D0CED23",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. There is an incomplete XSS filter allowing an attacker to inject crafted malicious code into the page."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.2.\u0026#xa0;Se presenta un filtro de XSS incompleto que permite a un atacante inyectar c\u00f3digo malicioso dise\u00f1ado en la p\u00e1gina"
        }
      ],
      "id": "CVE-2020-35563",
      "lastModified": "2026-06-17T03:13:56.603",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "LOW",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 3.5,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 6.8,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.4,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.3,
            "impactScore": 2.7,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.363",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-79"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35561

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. There is an SSRF in the HA module allowing an unauthenticated attacker to scan for open ports.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. There is an SSRF in the HA module allowing an unauthenticated attacker to scan for open ports."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta la v2.11.2. Existe un SSRF en el m\u00f3dulo HA que permite a un atacante no autentificado escanear puertos abiertos."
        }
      ],
      "id": "CVE-2020-35561",
      "lastModified": "2026-06-17T03:13:56.470",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "cve@mitre.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.317",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-918"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35560

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. There is an unauthenticated open redirect in the redirect.php.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD64D150-3FCD-4973-88EB-FDCBBC39BB4C",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FDA4DEB0-F344-4B04-8BFD-1D405D0CED23",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. There is an unauthenticated open redirect in the redirect.php."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.2.\u0026#xa0;Se presenta un redireccionamiento abierto no autenticado en el archivo redirect.php"
        }
      ],
      "id": "CVE-2020-35560",
      "lastModified": "2026-06-17T03:13:55.357",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 4.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 2.7,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.253",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-601"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35559

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. There is an unused function that allows an authenticated attacker to use up all available IPs of an account and thus not allow creation of new devices and users.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD64D150-3FCD-4973-88EB-FDCBBC39BB4C",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FDA4DEB0-F344-4B04-8BFD-1D405D0CED23",
                  "versionEndIncluding": "2.6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. There is an unused function that allows an authenticated attacker to use up all available IPs of an account and thus not allow creation of new devices and users."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.2.\u0026#xa0;Existe una funci\u00f3n en desuso que permite a un atacante autenticado usar todas las direcciones IP disponibles de una cuenta y, por lo tanto, no permite la creaci\u00f3n de nuevos dispositivos y usuarios"
        }
      ],
      "id": "CVE-2020-35559",
      "lastModified": "2026-06-17T03:13:55.230",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.190",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/de-de/advisories/vde-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-400"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35558

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual through 2.11.2. There is an SSRF in the in the MySQL access check, allowing an attacker to scan for open ports and gain some information about possible credentials.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual through 2.11.2. There is an SSRF in the in the MySQL access check, allowing an attacker to scan for open ports and gain some information about possible credentials."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en la l\u00ednea de conexi\u00f3n MB mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual hasta la versi\u00f3n 2.11.2. Hay un SSRF en la en la comprobaci\u00f3n de acceso a MySQL, lo que permite a un atacante escanear los puertos abiertos y obtener alguna informaci\u00f3n sobre posibles credenciales"
        }
      ],
      "id": "CVE-2020-35558",
      "lastModified": "2026-06-17T03:13:55.090",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "cve@mitre.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.113",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-918"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-35557

    Vulnerability from fkie_nvd - Published: 2021-02-16 16:15 - Updated: 2026-06-17 03:13
    Summary
    An issue in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 allows a logged in user to see devices in the account he should not have access to due to improper use of access validation.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D55D697-78A4-44E3-B6B6-E5349C610148",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04561EEC-B011-46F8-8C56-E5546D0ECD6A",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE3EED2-43AC-4129-B2C8-88DEBFEF8BA0",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "847B9BE1-D7E5-4B6B-A59D-282BB58A8B64",
                  "versionEndIncluding": "2.11.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 allows a logged in user to see devices in the account he should not have access to due to improper use of access validation."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24, mbCONNECT24 y Helmholz myREX24 y myREX24.virtual en todas las versiones hasta la v2.11.2 permite a un usuario conectado ver dispositivos en la cuenta a la que no deber\u00eda tener acceso debido al uso incorrecto de la validaci\u00f3n de acceso"
        }
      ],
      "id": "CVE-2020-35557",
      "lastModified": "2026-06-17T03:13:54.953",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "cve@mitre.org",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-02-16T16:15:13.050",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-003"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-039"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-269"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-24570

    Vulnerability from fkie_nvd - Published: 2020-09-30 18:15 - Updated: 2026-06-17 03:05
    Summary
    An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a CSRF issue (with resultant SSRF) in the com_mb24proxy module, allowing attackers to steal session information from logged-in users with a crafted link.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9AD8797-E4EC-4740-997B-8544E40A69BC",
                  "versionEndIncluding": "2.6.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "64885B25-1389-40BA-830A-260ADFE66C8A",
                  "versionEndIncluding": "2.6.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a CSRF issue (with resultant SSRF) in the com_mb24proxy module, allowing attackers to steal session information from logged-in users with a crafted link."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.1.\u0026#xa0;Se presenta un problema de tipo CSRF (con un SSRF resultante) en el m\u00f3dulo com_mb24proxy, permitiendo a atacantes robar informaci\u00f3n de la sesi\u00f3n de los usuarios que han iniciado sesi\u00f3n con un enlace dise\u00f1ado"
        }
      ],
      "id": "CVE-2020-24570",
      "lastModified": "2026-06-17T03:05:46.863",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-09-30T18:15:25.130",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-352"
            },
            {
              "lang": "en",
              "value": "CWE-918"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-24569

    Vulnerability from fkie_nvd - Published: 2020-09-30 18:15 - Updated: 2026-06-17 03:05
    Summary
    An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the knximport component via an advanced attack vector, allowing logged in attackers to discover arbitrary information.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9AD8797-E4EC-4740-997B-8544E40A69BC",
                  "versionEndIncluding": "2.6.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "64885B25-1389-40BA-830A-260ADFE66C8A",
                  "versionEndIncluding": "2.6.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the knximport component via an advanced attack vector, allowing logged in attackers to discover arbitrary information."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.1.\u0026#xa0;Se presenta una inyecci\u00f3n SQL ciega en el componente knximport por medio de un vector de ataque avanzado, permitiendo a atacantes registrados detectar informaci\u00f3n arbitraria"
        }
      ],
      "id": "CVE-2020-24569",
      "lastModified": "2026-06-17T03:05:46.750",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-09-30T18:15:25.053",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-89"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-24568

    Vulnerability from fkie_nvd - Published: 2020-10-02 19:15 - Updated: 2026-06-17 03:05
    Summary
    An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9AD8797-E4EC-4740-997B-8544E40A69BC",
                  "versionEndIncluding": "2.6.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "64885B25-1389-40BA-830A-260ADFE66C8A",
                  "versionEndIncluding": "2.6.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.1.\u0026#xa0;Se presenta una inyecci\u00f3n SQL ciega en el componente lancompenent, lo que permite a atacantes que han iniciado sesi\u00f3n detectar informaci\u00f3n arbitraria"
        }
      ],
      "id": "CVE-2020-24568",
      "lastModified": "2026-06-17T03:05:46.647",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-10-02T19:15:13.477",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://mbconnectline.com/security-advice/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-89"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }