Search criteria
9 vulnerabilities found for m\!dge by racom
VAR-202102-0907
Vulnerability from variot - Updated: 2024-11-23 21:58Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows users to escape the provided command line interface and execute arbitrary OS commands. Racom MIDGE For firmware, OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. Attackers can use this vulnerability to execute arbitrary OS commands
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0907",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "m\\!dge",
"scope": "eq",
"trust": 1.0,
"vendor": "racom",
"version": "4.4.40.105"
},
{
"model": "midge",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": "midge firmware 4.4.40.105"
},
{
"model": "midge",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": null
},
{
"model": "m!dge",
"scope": "eq",
"trust": 0.6,
"vendor": "racom",
"version": "4.4.40.105"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12633"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003832"
},
{
"db": "NVD",
"id": "CVE-2021-20074"
}
]
},
"cve": "CVE-2021-20074",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2021-20074",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2021-12633",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2021-20074",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-20074",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-20074",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2021-20074",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2021-12633",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202102-1207",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12633"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003832"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1207"
},
{
"db": "NVD",
"id": "CVE-2021-20074"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s MIDGE Firmware 4.4.40.105 contains an issue that allows users to escape the provided command line interface and execute arbitrary OS commands. Racom MIDGE For firmware, OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. Attackers can use this vulnerability to execute arbitrary OS commands",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-20074"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003832"
},
{
"db": "CNVD",
"id": "CNVD-2021-12633"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-20074",
"trust": 3.0
},
{
"db": "TENABLE",
"id": "TRA-2021-04",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003832",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-12633",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1207",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12633"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003832"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1207"
},
{
"db": "NVD",
"id": "CVE-2021-20074"
}
]
},
"id": "VAR-202102-0907",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12633"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12633"
}
]
},
"last_update_date": "2024-11-23T21:58:48.329000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.racom.eu/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003832"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.0
},
{
"problemtype": "OS Command injection (CWE-78) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003832"
},
{
"db": "NVD",
"id": "CVE-2021-20074"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://www.tenable.com/security/research/tra-2021-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-20074"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12633"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003832"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1207"
},
{
"db": "NVD",
"id": "CVE-2021-20074"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-12633"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003832"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1207"
},
{
"db": "NVD",
"id": "CVE-2021-20074"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12633"
},
{
"date": "2021-11-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-003832"
},
{
"date": "2021-02-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1207"
},
{
"date": "2021-02-16T20:15:16.283000",
"db": "NVD",
"id": "CVE-2021-20074"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12633"
},
{
"date": "2021-11-05T09:02:00",
"db": "JVNDB",
"id": "JVNDB-2021-003832"
},
{
"date": "2021-03-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1207"
},
{
"date": "2024-11-21T05:45:52.670000",
"db": "NVD",
"id": "CVE-2021-20074"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1207"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u00a0MIDGE\u00a0 In firmware \u00a0OS\u00a0 Command injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003832"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1207"
}
],
"trust": 0.6
}
}
VAR-202102-0901
Vulnerability from variot - Updated: 2024-11-23 21:58Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to conduct cross-site scripting attacks via the error handling functionality of web pages. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0901",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "m\\!dge",
"scope": "eq",
"trust": 1.0,
"vendor": "racom",
"version": "4.4.40.105"
},
{
"model": "midge cellular router",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": "midge cellular router firmware 4.4.40.105"
},
{
"model": "midge cellular router",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": null
},
{
"model": "m!dge",
"scope": "eq",
"trust": 0.6,
"vendor": "racom",
"version": "4.4.40.105"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12627"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004001"
},
{
"db": "NVD",
"id": "CVE-2021-20068"
}
]
},
"cve": "CVE-2021-20068",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CVE-2021-20068",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CNVD-2021-12627",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.7,
"id": "CVE-2021-20068",
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.8,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2021-20068",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "High",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-20068",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2021-20068",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2021-12627",
"trust": 0.6,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-202102-1243",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12627"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004001"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1243"
},
{
"db": "NVD",
"id": "CVE-2021-20068"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to conduct cross-site scripting attacks via the error handling functionality of web pages. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-20068"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004001"
},
{
"db": "CNVD",
"id": "CNVD-2021-12627"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-20068",
"trust": 3.0
},
{
"db": "TENABLE",
"id": "TRA-2021-04",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004001",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-12627",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1243",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12627"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004001"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1243"
},
{
"db": "NVD",
"id": "CVE-2021-20068"
}
]
},
"id": "VAR-202102-0901",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12627"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12627"
}
]
},
"last_update_date": "2024-11-23T21:58:48.305000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.racom.eu/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-004001"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.0
},
{
"problemtype": "Cross-site scripting (CWE-79) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-004001"
},
{
"db": "NVD",
"id": "CVE-2021-20068"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://www.tenable.com/security/research/tra-2021-04"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-20068"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12627"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004001"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1243"
},
{
"db": "NVD",
"id": "CVE-2021-20068"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-12627"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004001"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1243"
},
{
"db": "NVD",
"id": "CVE-2021-20068"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12627"
},
{
"date": "2021-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-004001"
},
{
"date": "2021-02-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1243"
},
{
"date": "2021-02-16T20:15:15.970000",
"db": "NVD",
"id": "CVE-2021-20068"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12627"
},
{
"date": "2021-11-12T02:17:00",
"db": "JVNDB",
"id": "JVNDB-2021-004001"
},
{
"date": "2021-02-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1243"
},
{
"date": "2024-11-21T05:45:51.977000",
"db": "NVD",
"id": "CVE-2021-20068"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1243"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s\u00a0MIDGE\u00a0Firmware\u00a0 Cross-site Scripting Vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-004001"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1243"
}
],
"trust": 0.6
}
}
VAR-202102-0902
Vulnerability from variot - Updated: 2024-11-23 21:58Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to conduct cross-site scripting attacks via the regionalSettings.php dialogs. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. Attackers can use this vulnerability to execute JavaScript code through regionalSettings.php
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0902",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "m\\!dge",
"scope": "eq",
"trust": 1.0,
"vendor": "racom",
"version": "4.4.40.105"
},
{
"model": "midge cellular router",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": "midge cellular router firmware 4.4.40.105"
},
{
"model": "midge cellular router",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": null
},
{
"model": "m!dge",
"scope": "eq",
"trust": 0.6,
"vendor": "racom",
"version": "4.4.40.105"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12628"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003999"
},
{
"db": "NVD",
"id": "CVE-2021-20069"
}
]
},
"cve": "CVE-2021-20069",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CVE-2021-20069",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CNVD-2021-12628",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.7,
"id": "CVE-2021-20069",
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.8,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2021-20069",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "High",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-20069",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2021-20069",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2021-12628",
"trust": 0.6,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-202102-1242",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12628"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003999"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1242"
},
{
"db": "NVD",
"id": "CVE-2021-20069"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to conduct cross-site scripting attacks via the regionalSettings.php dialogs. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. Attackers can use this vulnerability to execute JavaScript code through regionalSettings.php",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-20069"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003999"
},
{
"db": "CNVD",
"id": "CNVD-2021-12628"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-20069",
"trust": 3.0
},
{
"db": "TENABLE",
"id": "TRA-2021-04",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003999",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-12628",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1242",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12628"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003999"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1242"
},
{
"db": "NVD",
"id": "CVE-2021-20069"
}
]
},
"id": "VAR-202102-0902",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12628"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12628"
}
]
},
"last_update_date": "2024-11-23T21:58:48.280000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.racom.eu/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003999"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.0
},
{
"problemtype": "Cross-site scripting (CWE-79) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003999"
},
{
"db": "NVD",
"id": "CVE-2021-20069"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://www.tenable.com/security/research/tra-2021-04"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-20069"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12628"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003999"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1242"
},
{
"db": "NVD",
"id": "CVE-2021-20069"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-12628"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003999"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1242"
},
{
"db": "NVD",
"id": "CVE-2021-20069"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12628"
},
{
"date": "2021-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-003999"
},
{
"date": "2021-02-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1242"
},
{
"date": "2021-02-16T20:15:16.017000",
"db": "NVD",
"id": "CVE-2021-20069"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12628"
},
{
"date": "2021-11-12T02:10:00",
"db": "JVNDB",
"id": "JVNDB-2021-003999"
},
{
"date": "2021-02-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1242"
},
{
"date": "2024-11-21T05:45:52.090000",
"db": "NVD",
"id": "CVE-2021-20069"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1242"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s\u00a0MIDGE\u00a0Firmware\u00a0 Cross-site Scripting Vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003999"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1242"
}
],
"trust": 0.6
}
}
VAR-202102-0908
Vulnerability from variot - Updated: 2024-11-23 21:58Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows for privilege escalation via configd. Racom's MIDGE Firmware Contains a privilege management vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. Attackers can use this vulnerability to elevate permissions through configd
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0908",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "m\\!dge",
"scope": "eq",
"trust": 1.0,
"vendor": "racom",
"version": "4.4.40.105"
},
{
"model": "midge cellular router",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": "midge cellular router firmware 4.4.40.105"
},
{
"model": "midge cellular router",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": null
},
{
"model": "m!dge",
"scope": "eq",
"trust": 0.6,
"vendor": "racom",
"version": "4.4.40.105"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12634"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003993"
},
{
"db": "NVD",
"id": "CVE-2021-20075"
}
]
},
"cve": "CVE-2021-20075",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CVE-2021-20075",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2021-12634",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2021-20075",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-20075",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-20075",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2021-20075",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2021-12634",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202102-1205",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12634"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003993"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1205"
},
{
"db": "NVD",
"id": "CVE-2021-20075"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s MIDGE Firmware 4.4.40.105 contains an issue that allows for privilege escalation via configd. Racom\u0027s MIDGE Firmware Contains a privilege management vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. Attackers can use this vulnerability to elevate permissions through configd",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-20075"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003993"
},
{
"db": "CNVD",
"id": "CNVD-2021-12634"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-20075",
"trust": 3.0
},
{
"db": "TENABLE",
"id": "TRA-2021-04",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003993",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-12634",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1205",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12634"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003993"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1205"
},
{
"db": "NVD",
"id": "CVE-2021-20075"
}
]
},
"id": "VAR-202102-0908",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12634"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12634"
}
]
},
"last_update_date": "2024-11-23T21:58:48.254000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.racom.eu/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003993"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-269",
"trust": 1.0
},
{
"problemtype": "Improper authority management (CWE-269) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003993"
},
{
"db": "NVD",
"id": "CVE-2021-20075"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://www.tenable.com/security/research/tra-2021-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-20075"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12634"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003993"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1205"
},
{
"db": "NVD",
"id": "CVE-2021-20075"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-12634"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003993"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1205"
},
{
"db": "NVD",
"id": "CVE-2021-20075"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12634"
},
{
"date": "2021-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-003993"
},
{
"date": "2021-02-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1205"
},
{
"date": "2021-02-16T20:15:16.347000",
"db": "NVD",
"id": "CVE-2021-20075"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12634"
},
{
"date": "2021-11-12T01:45:00",
"db": "JVNDB",
"id": "JVNDB-2021-003993"
},
{
"date": "2021-02-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1205"
},
{
"date": "2024-11-21T05:45:52.787000",
"db": "NVD",
"id": "CVE-2021-20075"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1205"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s\u00a0MIDGE\u00a0Firmware\u00a0 Vulnerability in privilege management",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003993"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1205"
}
],
"trust": 0.6
}
}
VAR-202102-0906
Vulnerability from variot - Updated: 2024-11-23 21:58Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows for cross-site request forgeries. Racom MIDGE A cross-site request forgery vulnerability exists in the firmware.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. No detailed vulnerability details are currently provided
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0906",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "m\\!dge",
"scope": "eq",
"trust": 1.0,
"vendor": "racom",
"version": "4.4.40.105"
},
{
"model": "midge",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": "midge firmware 4.4.40.105"
},
{
"model": "midge",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": null
},
{
"model": "m!dge",
"scope": "eq",
"trust": 0.6,
"vendor": "racom",
"version": "4.4.40.105"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12632"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003831"
},
{
"db": "NVD",
"id": "CVE-2021-20073"
}
]
},
"cve": "CVE-2021-20073",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CVE-2021-20073",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CNVD-2021-12632",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2021-20073",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-20073",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-20073",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2021-20073",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2021-12632",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202102-1208",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12632"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003831"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1208"
},
{
"db": "NVD",
"id": "CVE-2021-20073"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s MIDGE Firmware 4.4.40.105 contains an issue that allows for cross-site request forgeries. Racom MIDGE A cross-site request forgery vulnerability exists in the firmware.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. No detailed vulnerability details are currently provided",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-20073"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003831"
},
{
"db": "CNVD",
"id": "CNVD-2021-12632"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-20073",
"trust": 3.0
},
{
"db": "TENABLE",
"id": "TRA-2021-04",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003831",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-12632",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1208",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12632"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003831"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1208"
},
{
"db": "NVD",
"id": "CVE-2021-20073"
}
]
},
"id": "VAR-202102-0906",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12632"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12632"
}
]
},
"last_update_date": "2024-11-23T21:58:48.228000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.racom.eu/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003831"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-352",
"trust": 1.0
},
{
"problemtype": "Cross-site request forgery (CWE-352) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003831"
},
{
"db": "NVD",
"id": "CVE-2021-20073"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://www.tenable.com/security/research/tra-2021-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-20073"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12632"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003831"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1208"
},
{
"db": "NVD",
"id": "CVE-2021-20073"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-12632"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003831"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1208"
},
{
"db": "NVD",
"id": "CVE-2021-20073"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12632"
},
{
"date": "2021-11-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-003831"
},
{
"date": "2021-02-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1208"
},
{
"date": "2021-02-16T20:15:16.220000",
"db": "NVD",
"id": "CVE-2021-20073"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12632"
},
{
"date": "2021-11-05T09:02:00",
"db": "JVNDB",
"id": "JVNDB-2021-003831"
},
{
"date": "2021-08-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1208"
},
{
"date": "2024-11-21T05:45:52.550000",
"db": "NVD",
"id": "CVE-2021-20073"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1208"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u00a0MIDGE\u00a0 Cross-site request forgery vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003831"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "cross-site request forgery",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1208"
}
],
"trust": 0.6
}
}
VAR-202102-0905
Vulnerability from variot - Updated: 2024-11-23 21:58Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to arbitrarily access and delete files via an authenticated directory traveral. Racom MIDGE There is a permission management vulnerability in the firmware.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications.
RACOM M!DGE version 4.4.40.105 firmware has a directory traversal vulnerability
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0905",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "m\\!dge",
"scope": "eq",
"trust": 1.0,
"vendor": "racom",
"version": "4.4.40.105"
},
{
"model": "midge",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": "midge firmware 4.4.40.105"
},
{
"model": "midge",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": null
},
{
"model": "m!dge",
"scope": "eq",
"trust": 0.6,
"vendor": "racom",
"version": "4.4.40.105"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12631"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003830"
},
{
"db": "NVD",
"id": "CVE-2021-20072"
}
]
},
"cve": "CVE-2021-20072",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 8.7,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2021-20072",
"impactScore": 9.5,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:P/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.7,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2021-12631",
"impactScore": 9.5,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:P/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2021-20072",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.2,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-20072",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-20072",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2021-20072",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2021-12631",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202102-1239",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12631"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003830"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1239"
},
{
"db": "NVD",
"id": "CVE-2021-20072"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to arbitrarily access and delete files via an authenticated directory traveral. Racom MIDGE There is a permission management vulnerability in the firmware.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. \n\r\n\r\nRACOM M!DGE version 4.4.40.105 firmware has a directory traversal vulnerability",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-20072"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003830"
},
{
"db": "CNVD",
"id": "CNVD-2021-12631"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-20072",
"trust": 3.0
},
{
"db": "TENABLE",
"id": "TRA-2021-04",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003830",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-12631",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1239",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12631"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003830"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1239"
},
{
"db": "NVD",
"id": "CVE-2021-20072"
}
]
},
"id": "VAR-202102-0905",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12631"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12631"
}
]
},
"last_update_date": "2024-11-23T21:58:48.202000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.racom.eu/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003830"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-22",
"trust": 1.0
},
{
"problemtype": "Improper authority management (CWE-269) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003830"
},
{
"db": "NVD",
"id": "CVE-2021-20072"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://www.tenable.com/security/research/tra-2021-04"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-20072"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12631"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003830"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1239"
},
{
"db": "NVD",
"id": "CVE-2021-20072"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-12631"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003830"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1239"
},
{
"db": "NVD",
"id": "CVE-2021-20072"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12631"
},
{
"date": "2021-11-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-003830"
},
{
"date": "2021-02-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1239"
},
{
"date": "2021-02-16T20:15:16.157000",
"db": "NVD",
"id": "CVE-2021-20072"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12631"
},
{
"date": "2021-11-05T09:02:00",
"db": "JVNDB",
"id": "JVNDB-2021-003830"
},
{
"date": "2022-07-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1239"
},
{
"date": "2024-11-21T05:45:52.433000",
"db": "NVD",
"id": "CVE-2021-20072"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1239"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u00a0MIDGE\u00a0 Privilege management vulnerabilities in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003830"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "path traversal",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1239"
}
],
"trust": 0.6
}
}
VAR-202102-0903
Vulnerability from variot - Updated: 2024-11-23 21:58Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to conduct cross-site scriptings attacks via the virtualization.php dialogs. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. Attackers can use this vulnerability to execute JavaScript code through virtualization.php
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0903",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "m\\!dge",
"scope": "eq",
"trust": 1.0,
"vendor": "racom",
"version": "4.4.40.105"
},
{
"model": "midge cellular router",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": "midge cellular router firmware 4.4.40.105"
},
{
"model": "midge cellular router",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": null
},
{
"model": "m!dge",
"scope": "eq",
"trust": 0.6,
"vendor": "racom",
"version": "4.4.40.105"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12629"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003996"
},
{
"db": "NVD",
"id": "CVE-2021-20070"
}
]
},
"cve": "CVE-2021-20070",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CVE-2021-20070",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CNVD-2021-12629",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.7,
"id": "CVE-2021-20070",
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.8,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2021-20070",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "High",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-20070",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2021-20070",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2021-12629",
"trust": 0.6,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-202102-1241",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12629"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003996"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1241"
},
{
"db": "NVD",
"id": "CVE-2021-20070"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to conduct cross-site scriptings attacks via the virtualization.php dialogs. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. Attackers can use this vulnerability to execute JavaScript code through virtualization.php",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-20070"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003996"
},
{
"db": "CNVD",
"id": "CNVD-2021-12629"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-20070",
"trust": 3.0
},
{
"db": "TENABLE",
"id": "TRA-2021-04",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003996",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-12629",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1241",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12629"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003996"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1241"
},
{
"db": "NVD",
"id": "CVE-2021-20070"
}
]
},
"id": "VAR-202102-0903",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12629"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12629"
}
]
},
"last_update_date": "2024-11-23T21:58:48.176000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.racom.eu/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003996"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.0
},
{
"problemtype": "Cross-site scripting (CWE-79) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003996"
},
{
"db": "NVD",
"id": "CVE-2021-20070"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://www.tenable.com/security/research/tra-2021-04"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-20070"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12629"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003996"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1241"
},
{
"db": "NVD",
"id": "CVE-2021-20070"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-12629"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003996"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1241"
},
{
"db": "NVD",
"id": "CVE-2021-20070"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12629"
},
{
"date": "2021-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-003996"
},
{
"date": "2021-02-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1241"
},
{
"date": "2021-02-16T20:15:16.067000",
"db": "NVD",
"id": "CVE-2021-20070"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12629"
},
{
"date": "2021-11-12T01:58:00",
"db": "JVNDB",
"id": "JVNDB-2021-003996"
},
{
"date": "2021-02-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1241"
},
{
"date": "2024-11-21T05:45:52.207000",
"db": "NVD",
"id": "CVE-2021-20070"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1241"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s\u00a0MIDGE\u00a0Firmware\u00a0 Cross-site Scripting Vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003996"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1241"
}
],
"trust": 0.6
}
}
VAR-202102-0900
Vulnerability from variot - Updated: 2024-11-23 21:58Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to view sensitive syslog events without authentication. Racom MIDGE There is an information leakage vulnerability in the firmware.Information may be obtained. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0900",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "m\\!dge",
"scope": "eq",
"trust": 1.0,
"vendor": "racom",
"version": "4.4.40.105"
},
{
"model": "midge",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": "midge firmware 4.4.40.105"
},
{
"model": "midge",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": null
},
{
"model": "m!dge",
"scope": "eq",
"trust": 0.6,
"vendor": "racom",
"version": "4.4.40.105"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12626"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003829"
},
{
"db": "NVD",
"id": "CVE-2021-20067"
}
]
},
"cve": "CVE-2021-20067",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2021-20067",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-12626",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 3.9,
"id": "CVE-2021-20067",
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.3,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2021-20067",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-20067",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2021-20067",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2021-12626",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202102-1244",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12626"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003829"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1244"
},
{
"db": "NVD",
"id": "CVE-2021-20067"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to view sensitive syslog events without authentication. Racom MIDGE There is an information leakage vulnerability in the firmware.Information may be obtained. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-20067"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003829"
},
{
"db": "CNVD",
"id": "CNVD-2021-12626"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-20067",
"trust": 3.0
},
{
"db": "TENABLE",
"id": "TRA-2021-04",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003829",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-12626",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1244",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12626"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003829"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1244"
},
{
"db": "NVD",
"id": "CVE-2021-20067"
}
]
},
"id": "VAR-202102-0900",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12626"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12626"
}
]
},
"last_update_date": "2024-11-23T21:58:48.150000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.racom.eu/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003829"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-306",
"trust": 1.0
},
{
"problemtype": "information leak (CWE-200) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003829"
},
{
"db": "NVD",
"id": "CVE-2021-20067"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://www.tenable.com/security/research/tra-2021-04"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-20067"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12626"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003829"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1244"
},
{
"db": "NVD",
"id": "CVE-2021-20067"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-12626"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003829"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1244"
},
{
"db": "NVD",
"id": "CVE-2021-20067"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12626"
},
{
"date": "2021-11-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-003829"
},
{
"date": "2021-02-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1244"
},
{
"date": "2021-02-16T20:15:15.923000",
"db": "NVD",
"id": "CVE-2021-20067"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12626"
},
{
"date": "2021-11-05T09:02:00",
"db": "JVNDB",
"id": "JVNDB-2021-003829"
},
{
"date": "2021-03-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1244"
},
{
"date": "2024-11-21T05:45:51.857000",
"db": "NVD",
"id": "CVE-2021-20067"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1244"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u00a0\u00a0MIDGE\u00a0 Information leakage vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003829"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1244"
}
],
"trust": 0.6
}
}
VAR-202102-0904
Vulnerability from variot - Updated: 2024-11-23 21:58Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to conduct cross-site scriptings attacks via the sms.php dialogs. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. Attackers can use this vulnerability to execute javascript code through sms.php
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0904",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "m\\!dge",
"scope": "eq",
"trust": 1.0,
"vendor": "racom",
"version": "4.4.40.105"
},
{
"model": "midge cellular router",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": "midge cellular router firmware 4.4.40.105"
},
{
"model": "midge cellular router",
"scope": "eq",
"trust": 0.8,
"vendor": "racom",
"version": null
},
{
"model": "m!dge",
"scope": "eq",
"trust": 0.6,
"vendor": "racom",
"version": "4.4.40.105"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12630"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003994"
},
{
"db": "NVD",
"id": "CVE-2021-20071"
}
]
},
"cve": "CVE-2021-20071",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CVE-2021-20071",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CNVD-2021-12630",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.7,
"id": "CVE-2021-20071",
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.8,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2021-20071",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "High",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-20071",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2021-20071",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2021-12630",
"trust": 0.6,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-202102-1240",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12630"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003994"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1240"
},
{
"db": "NVD",
"id": "CVE-2021-20071"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s MIDGE Firmware 4.4.40.105 contains an issue that allows attackers to conduct cross-site scriptings attacks via the sms.php dialogs. RACOM M!DGE is a cellular router designed for mission-critical applications such as SCADA and telemetry, and is very suitable for many different wireless applications. Attackers can use this vulnerability to execute javascript code through sms.php",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-20071"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003994"
},
{
"db": "CNVD",
"id": "CNVD-2021-12630"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-20071",
"trust": 3.0
},
{
"db": "TENABLE",
"id": "TRA-2021-04",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003994",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-12630",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1240",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12630"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003994"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1240"
},
{
"db": "NVD",
"id": "CVE-2021-20071"
}
]
},
"id": "VAR-202102-0904",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12630"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12630"
}
]
},
"last_update_date": "2024-11-23T21:58:48.124000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.racom.eu/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003994"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.0
},
{
"problemtype": "Cross-site scripting (CWE-79) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003994"
},
{
"db": "NVD",
"id": "CVE-2021-20071"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://www.tenable.com/security/research/tra-2021-04"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-20071"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-12630"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003994"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1240"
},
{
"db": "NVD",
"id": "CVE-2021-20071"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-12630"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-003994"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1240"
},
{
"db": "NVD",
"id": "CVE-2021-20071"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12630"
},
{
"date": "2021-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-003994"
},
{
"date": "2021-02-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1240"
},
{
"date": "2021-02-16T20:15:16.110000",
"db": "NVD",
"id": "CVE-2021-20071"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-12630"
},
{
"date": "2021-11-12T01:49:00",
"db": "JVNDB",
"id": "JVNDB-2021-003994"
},
{
"date": "2021-02-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1240"
},
{
"date": "2024-11-21T05:45:52.317000",
"db": "NVD",
"id": "CVE-2021-20071"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1240"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Racom\u0027s\u00a0MIDGE\u00a0Firmware\u00a0 Cross-site Scripting Vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-003994"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1240"
}
],
"trust": 0.6
}
}