Search criteria
2 vulnerabilities found for in3128hd by infocus
VAR-201505-0273
Vulnerability from variot - Updated: 2025-04-13 23:09The InFocus IN3128HD projector with firmware 0.26 does not restrict access to cgi-bin/webctrl.cgi.elf, which allows remote attackers to modify the DHCP server and device IP configuration, reboot the device, change the device name, and have other unspecified impact via a crafted request. Supplementary information : CWE Vulnerability type by CWE-306: Missing Authentication for Critical Function ( Lack of authentication for critical functions ) Has been identified. may cause unspecified effects. The InFocus IN3128HD projector is a projector product used by the InFocus company in the education industry. There is a security hole in the InFocus IN3128HD projector with firmware version 0.26. The program failed to restrict access to the cgi-bin/webctrl.cgi.elf file. An attacker can exploit this issue to bypass the authentication process and gain unauthorized access to the system. Successfully exploiting this issue may lead to further attacks. InFocus IN3128HD 0.26 is vulnerable
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201505-0273",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "in3128hd",
"scope": "eq",
"trust": 3.3,
"vendor": "infocus",
"version": "0.26"
},
{
"model": "in3128hd projector",
"scope": null,
"trust": 0.8,
"vendor": "infocus",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03218"
},
{
"db": "BID",
"id": "74360"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002725"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-308"
},
{
"db": "NVD",
"id": "CVE-2014-8384"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:infocus:in3128hd_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:infocus:in3128hd",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-002725"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Joaquin Rodriguez Varela from Core Security CoreLabs Team.",
"sources": [
{
"db": "BID",
"id": "74360"
}
],
"trust": 0.3
},
"cve": "CVE-2014-8384",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 9.4,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2014-8384",
"impactScore": 9.2,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.4,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2015-03218",
"impactScore": 9.2,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.4,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "VHN-76329",
"impactScore": 9.2,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:N/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2014-8384",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2014-8384",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2015-03218",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201505-308",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-76329",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03218"
},
{
"db": "VULHUB",
"id": "VHN-76329"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002725"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-308"
},
{
"db": "NVD",
"id": "CVE-2014-8384"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The InFocus IN3128HD projector with firmware 0.26 does not restrict access to cgi-bin/webctrl.cgi.elf, which allows remote attackers to modify the DHCP server and device IP configuration, reboot the device, change the device name, and have other unspecified impact via a crafted request. Supplementary information : CWE Vulnerability type by CWE-306: Missing Authentication for Critical Function ( Lack of authentication for critical functions ) Has been identified. may cause unspecified effects. The InFocus IN3128HD projector is a projector product used by the InFocus company in the education industry. There is a security hole in the InFocus IN3128HD projector with firmware version 0.26. The program failed to restrict access to the cgi-bin/webctrl.cgi.elf file. \nAn attacker can exploit this issue to bypass the authentication process and gain unauthorized access to the system. Successfully exploiting this issue may lead to further attacks. \nInFocus IN3128HD 0.26 is vulnerable",
"sources": [
{
"db": "NVD",
"id": "CVE-2014-8384"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002725"
},
{
"db": "CNVD",
"id": "CNVD-2015-03218"
},
{
"db": "BID",
"id": "74360"
},
{
"db": "VULHUB",
"id": "VHN-76329"
}
],
"trust": 2.52
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2014-8384",
"trust": 3.4
},
{
"db": "PACKETSTORM",
"id": "131661",
"trust": 2.3
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002725",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201505-308",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2015-03218",
"trust": 0.6
},
{
"db": "BID",
"id": "74360",
"trust": 0.4
},
{
"db": "VULHUB",
"id": "VHN-76329",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03218"
},
{
"db": "VULHUB",
"id": "VHN-76329"
},
{
"db": "BID",
"id": "74360"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002725"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-308"
},
{
"db": "NVD",
"id": "CVE-2014-8384"
}
]
},
"id": "VAR-201505-0273",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03218"
},
{
"db": "VULHUB",
"id": "VHN-76329"
}
],
"trust": 1.2999999999999998
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03218"
}
]
},
"last_update_date": "2025-04-13T23:09:54.312000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "InFocus IN3128HD Projector",
"trust": 0.8,
"url": "http://www.infocus.com/projectors/IN3128HD"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-002725"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-Other",
"trust": 1.0
},
{
"problemtype": "CWE-Other",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-002725"
},
{
"db": "NVD",
"id": "CVE-2014-8384"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.4,
"url": "http://www.coresecurity.com/advisories/infocus-in3128hd-projector-multiple-vulnerabilities"
},
{
"trust": 2.3,
"url": "http://seclists.org/fulldisclosure/2015/apr/88"
},
{
"trust": 2.3,
"url": "http://packetstormsecurity.com/files/131661/infocus-in3128hd-projector-missing-authentication.html"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8384"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-8384"
},
{
"trust": 0.3,
"url": "http://www.infocus.com/projectors/in3128hd"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03218"
},
{
"db": "VULHUB",
"id": "VHN-76329"
},
{
"db": "BID",
"id": "74360"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002725"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-308"
},
{
"db": "NVD",
"id": "CVE-2014-8384"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2015-03218"
},
{
"db": "VULHUB",
"id": "VHN-76329"
},
{
"db": "BID",
"id": "74360"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002725"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-308"
},
{
"db": "NVD",
"id": "CVE-2014-8384"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-05-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-03218"
},
{
"date": "2015-05-18T00:00:00",
"db": "VULHUB",
"id": "VHN-76329"
},
{
"date": "2015-04-27T00:00:00",
"db": "BID",
"id": "74360"
},
{
"date": "2015-05-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-002725"
},
{
"date": "2015-05-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201505-308"
},
{
"date": "2015-05-18T15:59:01.637000",
"db": "NVD",
"id": "CVE-2014-8384"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-05-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-03218"
},
{
"date": "2015-05-19T00:00:00",
"db": "VULHUB",
"id": "VHN-76329"
},
{
"date": "2015-04-27T00:00:00",
"db": "BID",
"id": "74360"
},
{
"date": "2015-05-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-002725"
},
{
"date": "2015-05-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201505-308"
},
{
"date": "2025-04-12T10:46:40.837000",
"db": "NVD",
"id": "CVE-2014-8384"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201505-308"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "InFocus IN3128HD In projector firmware DHCP Server and device IP Vulnerability whose settings are changed",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-002725"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Design Error",
"sources": [
{
"db": "BID",
"id": "74360"
}
],
"trust": 0.3
}
}
VAR-201505-0272
Vulnerability from variot - Updated: 2025-04-13 23:09The InFocus IN3128HD projector with firmware 0.26 allows remote attackers to bypass authentication via a direct request to main.html. Supplementary information : CWE Vulnerability types by CWE-306: Missing Authentication for Critical Function ( Lack of authentication for critical functions ) Has been identified. The InFocus IN3128HD projector is a projector product used in the education industry. InFocus IN3128HD is prone to a remote authentication-bypass vulnerability. An attacker can exploit this issue to bypass the authentication mechanism and gain unauthorized access. This may aid in further attacks. InFocus IN3128HD running firmware version 0.26 is vulnerable
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201505-0272",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "in3128hd",
"scope": "eq",
"trust": 3.3,
"vendor": "infocus",
"version": "0.26"
},
{
"model": "in3128hd projector",
"scope": null,
"trust": 0.8,
"vendor": "infocus",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03321"
},
{
"db": "BID",
"id": "74359"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002724"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-307"
},
{
"db": "NVD",
"id": "CVE-2014-8383"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:infocus:in3128hd_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:infocus:in3128hd",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-002724"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Joaquin Rodriguez Varela from Core Security CoreLabs Team",
"sources": [
{
"db": "BID",
"id": "74359"
}
],
"trust": 0.3
},
"cve": "CVE-2014-8383",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2014-8383",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2015-03321",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-76328",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2014-8383",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2014-8383",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2015-03321",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201505-307",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-76328",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03321"
},
{
"db": "VULHUB",
"id": "VHN-76328"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002724"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-307"
},
{
"db": "NVD",
"id": "CVE-2014-8383"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The InFocus IN3128HD projector with firmware 0.26 allows remote attackers to bypass authentication via a direct request to main.html. Supplementary information : CWE Vulnerability types by CWE-306: Missing Authentication for Critical Function ( Lack of authentication for critical functions ) Has been identified. The InFocus IN3128HD projector is a projector product used in the education industry. InFocus IN3128HD is prone to a remote authentication-bypass vulnerability. \nAn attacker can exploit this issue to bypass the authentication mechanism and gain unauthorized access. This may aid in further attacks. \nInFocus IN3128HD running firmware version 0.26 is vulnerable",
"sources": [
{
"db": "NVD",
"id": "CVE-2014-8383"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002724"
},
{
"db": "CNVD",
"id": "CNVD-2015-03321"
},
{
"db": "BID",
"id": "74359"
},
{
"db": "VULHUB",
"id": "VHN-76328"
}
],
"trust": 2.52
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2014-8383",
"trust": 3.4
},
{
"db": "PACKETSTORM",
"id": "131661",
"trust": 1.7
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002724",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201505-307",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2015-03321",
"trust": 0.6
},
{
"db": "BID",
"id": "74359",
"trust": 0.4
},
{
"db": "VULHUB",
"id": "VHN-76328",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03321"
},
{
"db": "VULHUB",
"id": "VHN-76328"
},
{
"db": "BID",
"id": "74359"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002724"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-307"
},
{
"db": "NVD",
"id": "CVE-2014-8383"
}
]
},
"id": "VAR-201505-0272",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03321"
},
{
"db": "VULHUB",
"id": "VHN-76328"
}
],
"trust": 1.2999999999999998
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03321"
}
]
},
"last_update_date": "2025-04-13T23:09:54.279000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "InFocus IN3128HD Projector",
"trust": 0.8,
"url": "http://www.infocus.com/projectors/IN3128HD"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-002724"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-Other",
"trust": 1.0
},
{
"problemtype": "CWE-Other",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-002724"
},
{
"db": "NVD",
"id": "CVE-2014-8383"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.8,
"url": "http://www.coresecurity.com/advisories/infocus-in3128hd-projector-multiple-vulnerabilities"
},
{
"trust": 2.3,
"url": "http://seclists.org/fulldisclosure/2015/apr/88"
},
{
"trust": 1.7,
"url": "http://packetstormsecurity.com/files/131661/infocus-in3128hd-projector-missing-authentication.html"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8383"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-8383"
},
{
"trust": 0.3,
"url": "http://www.infocus.com/projectors/in3128hd"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03321"
},
{
"db": "VULHUB",
"id": "VHN-76328"
},
{
"db": "BID",
"id": "74359"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002724"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-307"
},
{
"db": "NVD",
"id": "CVE-2014-8383"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2015-03321"
},
{
"db": "VULHUB",
"id": "VHN-76328"
},
{
"db": "BID",
"id": "74359"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002724"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-307"
},
{
"db": "NVD",
"id": "CVE-2014-8383"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-05-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-03321"
},
{
"date": "2015-05-18T00:00:00",
"db": "VULHUB",
"id": "VHN-76328"
},
{
"date": "2015-04-27T00:00:00",
"db": "BID",
"id": "74359"
},
{
"date": "2015-05-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-002724"
},
{
"date": "2015-05-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201505-307"
},
{
"date": "2015-05-18T15:59:00.073000",
"db": "NVD",
"id": "CVE-2014-8383"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-05-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-03321"
},
{
"date": "2015-05-19T00:00:00",
"db": "VULHUB",
"id": "VHN-76328"
},
{
"date": "2015-04-27T00:00:00",
"db": "BID",
"id": "74359"
},
{
"date": "2015-05-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-002724"
},
{
"date": "2015-05-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201505-307"
},
{
"date": "2025-04-12T10:46:40.837000",
"db": "NVD",
"id": "CVE-2014-8383"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201505-307"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "InFocus IN3128HD Vulnerability to bypass authentication in projector firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-002724"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Design Error",
"sources": [
{
"db": "BID",
"id": "74359"
}
],
"trust": 0.3
}
}