Search criteria

2 vulnerabilities found for in3128hd by infocus

VAR-201505-0273

Vulnerability from variot - Updated: 2025-04-13 23:09

The InFocus IN3128HD projector with firmware 0.26 does not restrict access to cgi-bin/webctrl.cgi.elf, which allows remote attackers to modify the DHCP server and device IP configuration, reboot the device, change the device name, and have other unspecified impact via a crafted request. Supplementary information : CWE Vulnerability type by CWE-306: Missing Authentication for Critical Function ( Lack of authentication for critical functions ) Has been identified. may cause unspecified effects. The InFocus IN3128HD projector is a projector product used by the InFocus company in the education industry. There is a security hole in the InFocus IN3128HD projector with firmware version 0.26. The program failed to restrict access to the cgi-bin/webctrl.cgi.elf file. An attacker can exploit this issue to bypass the authentication process and gain unauthorized access to the system. Successfully exploiting this issue may lead to further attacks. InFocus IN3128HD 0.26 is vulnerable

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201505-0273",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "in3128hd",
        "scope": "eq",
        "trust": 3.3,
        "vendor": "infocus",
        "version": "0.26"
      },
      {
        "model": "in3128hd projector",
        "scope": null,
        "trust": 0.8,
        "vendor": "infocus",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03218"
      },
      {
        "db": "BID",
        "id": "74360"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002725"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-308"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-8384"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:infocus:in3128hd_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:infocus:in3128hd",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002725"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Joaquin Rodriguez Varela from Core Security CoreLabs Team.",
    "sources": [
      {
        "db": "BID",
        "id": "74360"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2014-8384",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.4,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2014-8384",
            "impactScore": 9.2,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.4,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2015-03218",
            "impactScore": 9.2,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.4,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-76329",
            "impactScore": 9.2,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2014-8384",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2014-8384",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2015-03218",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201505-308",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-76329",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03218"
      },
      {
        "db": "VULHUB",
        "id": "VHN-76329"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002725"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-308"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-8384"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The InFocus IN3128HD projector with firmware 0.26 does not restrict access to cgi-bin/webctrl.cgi.elf, which allows remote attackers to modify the DHCP server and device IP configuration, reboot the device, change the device name, and have other unspecified impact via a crafted request. Supplementary information : CWE Vulnerability type by CWE-306: Missing Authentication for Critical Function ( Lack of authentication for critical functions ) Has been identified. may cause unspecified effects. The InFocus IN3128HD projector is a projector product used by the InFocus company in the education industry. There is a security hole in the InFocus IN3128HD projector with firmware version 0.26. The program failed to restrict access to the cgi-bin/webctrl.cgi.elf file. \nAn attacker can exploit this issue to bypass the authentication process and gain unauthorized access to the system. Successfully exploiting this issue may lead to further attacks. \nInFocus IN3128HD 0.26 is vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2014-8384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002725"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-03218"
      },
      {
        "db": "BID",
        "id": "74360"
      },
      {
        "db": "VULHUB",
        "id": "VHN-76329"
      }
    ],
    "trust": 2.52
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2014-8384",
        "trust": 3.4
      },
      {
        "db": "PACKETSTORM",
        "id": "131661",
        "trust": 2.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002725",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-308",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-03218",
        "trust": 0.6
      },
      {
        "db": "BID",
        "id": "74360",
        "trust": 0.4
      },
      {
        "db": "VULHUB",
        "id": "VHN-76329",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03218"
      },
      {
        "db": "VULHUB",
        "id": "VHN-76329"
      },
      {
        "db": "BID",
        "id": "74360"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002725"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-308"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-8384"
      }
    ]
  },
  "id": "VAR-201505-0273",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03218"
      },
      {
        "db": "VULHUB",
        "id": "VHN-76329"
      }
    ],
    "trust": 1.2999999999999998
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03218"
      }
    ]
  },
  "last_update_date": "2025-04-13T23:09:54.312000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "InFocus IN3128HD Projector",
        "trust": 0.8,
        "url": "http://www.infocus.com/projectors/IN3128HD"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002725"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-Other",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002725"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-8384"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.4,
        "url": "http://www.coresecurity.com/advisories/infocus-in3128hd-projector-multiple-vulnerabilities"
      },
      {
        "trust": 2.3,
        "url": "http://seclists.org/fulldisclosure/2015/apr/88"
      },
      {
        "trust": 2.3,
        "url": "http://packetstormsecurity.com/files/131661/infocus-in3128hd-projector-missing-authentication.html"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8384"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-8384"
      },
      {
        "trust": 0.3,
        "url": "http://www.infocus.com/projectors/in3128hd"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03218"
      },
      {
        "db": "VULHUB",
        "id": "VHN-76329"
      },
      {
        "db": "BID",
        "id": "74360"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002725"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-308"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-8384"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03218"
      },
      {
        "db": "VULHUB",
        "id": "VHN-76329"
      },
      {
        "db": "BID",
        "id": "74360"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002725"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-308"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-8384"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-05-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-03218"
      },
      {
        "date": "2015-05-18T00:00:00",
        "db": "VULHUB",
        "id": "VHN-76329"
      },
      {
        "date": "2015-04-27T00:00:00",
        "db": "BID",
        "id": "74360"
      },
      {
        "date": "2015-05-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-002725"
      },
      {
        "date": "2015-05-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201505-308"
      },
      {
        "date": "2015-05-18T15:59:01.637000",
        "db": "NVD",
        "id": "CVE-2014-8384"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-05-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-03218"
      },
      {
        "date": "2015-05-19T00:00:00",
        "db": "VULHUB",
        "id": "VHN-76329"
      },
      {
        "date": "2015-04-27T00:00:00",
        "db": "BID",
        "id": "74360"
      },
      {
        "date": "2015-05-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-002725"
      },
      {
        "date": "2015-05-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201505-308"
      },
      {
        "date": "2025-04-12T10:46:40.837000",
        "db": "NVD",
        "id": "CVE-2014-8384"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-308"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "InFocus IN3128HD In projector firmware  DHCP Server and device  IP Vulnerability whose settings are changed",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002725"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Design Error",
    "sources": [
      {
        "db": "BID",
        "id": "74360"
      }
    ],
    "trust": 0.3
  }
}

VAR-201505-0272

Vulnerability from variot - Updated: 2025-04-13 23:09

The InFocus IN3128HD projector with firmware 0.26 allows remote attackers to bypass authentication via a direct request to main.html. Supplementary information : CWE Vulnerability types by CWE-306: Missing Authentication for Critical Function ( Lack of authentication for critical functions ) Has been identified. The InFocus IN3128HD projector is a projector product used in the education industry. InFocus IN3128HD is prone to a remote authentication-bypass vulnerability. An attacker can exploit this issue to bypass the authentication mechanism and gain unauthorized access. This may aid in further attacks. InFocus IN3128HD running firmware version 0.26 is vulnerable

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201505-0272",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "in3128hd",
        "scope": "eq",
        "trust": 3.3,
        "vendor": "infocus",
        "version": "0.26"
      },
      {
        "model": "in3128hd projector",
        "scope": null,
        "trust": 0.8,
        "vendor": "infocus",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03321"
      },
      {
        "db": "BID",
        "id": "74359"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002724"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-307"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-8383"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:infocus:in3128hd_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:infocus:in3128hd",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002724"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Joaquin Rodriguez Varela from Core Security CoreLabs Team",
    "sources": [
      {
        "db": "BID",
        "id": "74359"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2014-8383",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2014-8383",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2015-03321",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "VHN-76328",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2014-8383",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2014-8383",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2015-03321",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201505-307",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-76328",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03321"
      },
      {
        "db": "VULHUB",
        "id": "VHN-76328"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002724"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-307"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-8383"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The InFocus IN3128HD projector with firmware 0.26 allows remote attackers to bypass authentication via a direct request to main.html. Supplementary information : CWE Vulnerability types by CWE-306: Missing Authentication for Critical Function ( Lack of authentication for critical functions ) Has been identified. The InFocus IN3128HD projector is a projector product used in the education industry. InFocus IN3128HD is prone to a remote authentication-bypass vulnerability. \nAn attacker can exploit this issue to bypass the authentication mechanism and gain unauthorized access. This may aid in further attacks. \nInFocus IN3128HD running firmware version 0.26 is vulnerable",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2014-8383"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002724"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-03321"
      },
      {
        "db": "BID",
        "id": "74359"
      },
      {
        "db": "VULHUB",
        "id": "VHN-76328"
      }
    ],
    "trust": 2.52
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2014-8383",
        "trust": 3.4
      },
      {
        "db": "PACKETSTORM",
        "id": "131661",
        "trust": 1.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002724",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-307",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-03321",
        "trust": 0.6
      },
      {
        "db": "BID",
        "id": "74359",
        "trust": 0.4
      },
      {
        "db": "VULHUB",
        "id": "VHN-76328",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03321"
      },
      {
        "db": "VULHUB",
        "id": "VHN-76328"
      },
      {
        "db": "BID",
        "id": "74359"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002724"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-307"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-8383"
      }
    ]
  },
  "id": "VAR-201505-0272",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03321"
      },
      {
        "db": "VULHUB",
        "id": "VHN-76328"
      }
    ],
    "trust": 1.2999999999999998
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03321"
      }
    ]
  },
  "last_update_date": "2025-04-13T23:09:54.279000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "InFocus IN3128HD Projector",
        "trust": 0.8,
        "url": "http://www.infocus.com/projectors/IN3128HD"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002724"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-Other",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002724"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-8383"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.8,
        "url": "http://www.coresecurity.com/advisories/infocus-in3128hd-projector-multiple-vulnerabilities"
      },
      {
        "trust": 2.3,
        "url": "http://seclists.org/fulldisclosure/2015/apr/88"
      },
      {
        "trust": 1.7,
        "url": "http://packetstormsecurity.com/files/131661/infocus-in3128hd-projector-missing-authentication.html"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8383"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-8383"
      },
      {
        "trust": 0.3,
        "url": "http://www.infocus.com/projectors/in3128hd"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03321"
      },
      {
        "db": "VULHUB",
        "id": "VHN-76328"
      },
      {
        "db": "BID",
        "id": "74359"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002724"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-307"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-8383"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03321"
      },
      {
        "db": "VULHUB",
        "id": "VHN-76328"
      },
      {
        "db": "BID",
        "id": "74359"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002724"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-307"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-8383"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-05-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-03321"
      },
      {
        "date": "2015-05-18T00:00:00",
        "db": "VULHUB",
        "id": "VHN-76328"
      },
      {
        "date": "2015-04-27T00:00:00",
        "db": "BID",
        "id": "74359"
      },
      {
        "date": "2015-05-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-002724"
      },
      {
        "date": "2015-05-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201505-307"
      },
      {
        "date": "2015-05-18T15:59:00.073000",
        "db": "NVD",
        "id": "CVE-2014-8383"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-05-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-03321"
      },
      {
        "date": "2015-05-19T00:00:00",
        "db": "VULHUB",
        "id": "VHN-76328"
      },
      {
        "date": "2015-04-27T00:00:00",
        "db": "BID",
        "id": "74359"
      },
      {
        "date": "2015-05-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-002724"
      },
      {
        "date": "2015-05-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201505-307"
      },
      {
        "date": "2025-04-12T10:46:40.837000",
        "db": "NVD",
        "id": "CVE-2014-8383"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201505-307"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "InFocus IN3128HD Vulnerability to bypass authentication in projector firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-002724"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Design Error",
    "sources": [
      {
        "db": "BID",
        "id": "74359"
      }
    ],
    "trust": 0.3
  }
}