Search criteria

8 vulnerabilities found for ic-3140w_firmware by edimax

CVE-2021-40597 (GCVE-0-2021-40597)

Vulnerability from nvd – Published: 2022-06-29 19:44 – Updated: 2024-08-04 02:44
VLAI?
Summary
The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:44:10.864Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-29T19:44:58.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-40597",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/",
              "refsource": "MISC",
              "url": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/"
            },
            {
              "name": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing",
              "refsource": "MISC",
              "url": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing"
            },
            {
              "name": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing",
              "refsource": "MISC",
              "url": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-40597",
    "datePublished": "2022-06-29T19:44:58.000Z",
    "dateReserved": "2021-09-07T00:00:00.000Z",
    "dateUpdated": "2024-08-04T02:44:10.864Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-30165 (GCVE-0-2021-30165)

Vulnerability from nvd – Published: 2021-04-27 03:07 – Updated: 2024-09-17 00:21
VLAI?
Title
EDIMAX Technology Co., Ltd. HD Wireless Day & Night Network Camera IC-3140W - Hard-coded password
Summary
The default administrator account & password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:24:59.557Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IC-3140W",
          "vendor": "EDIMAX Technology Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "3.11"
            }
          ]
        }
      ],
      "datePublic": "2021-04-27T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The default administrator account \u0026 password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-27T03:07:36.000Z",
        "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "shortName": "twcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update IC-3140W firmware to version 3.12"
        }
      ],
      "source": {
        "advisory": "TVN-202104001",
        "discovery": "EXTERNAL"
      },
      "title": "EDIMAX Technology Co., Ltd. HD Wireless Day \u0026 Night Network Camera IC-3140W - Hard-coded password",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "TWCERT/CC",
          "ASSIGNER": "cve@cert.org.tw",
          "DATE_PUBLIC": "2021-04-27T02:52:00.000Z",
          "ID": "CVE-2021-30165",
          "STATE": "PUBLIC",
          "TITLE": "EDIMAX Technology Co., Ltd. HD Wireless Day \u0026 Night Network Camera IC-3140W - Hard-coded password"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IC-3140W",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "3.11",
                            "version_value": "3.11"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "EDIMAX Technology Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The default administrator account \u0026 password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798 Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html",
              "refsource": "MISC",
              "url": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update IC-3140W firmware to version 3.12"
          }
        ],
        "source": {
          "advisory": "TVN-202104001",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
    "assignerShortName": "twcert",
    "cveId": "CVE-2021-30165",
    "datePublished": "2021-04-27T03:07:36.944Z",
    "dateReserved": "2021-04-06T00:00:00.000Z",
    "dateUpdated": "2024-09-17T00:21:26.883Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-26762 (GCVE-0-2020-26762)

Vulnerability from nvd – Published: 2020-12-01 14:56 – Updated: 2024-08-04 16:03
VLAI?
Summary
A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:03:21.672Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-01T14:56:08.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-26762",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w",
              "refsource": "CONFIRM",
              "url": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-26762",
    "datePublished": "2020-12-01T14:56:08.000Z",
    "dateReserved": "2020-10-07T00:00:00.000Z",
    "dateUpdated": "2024-08-04T16:03:21.672Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-8072 (GCVE-0-2018-8072)

Vulnerability from nvd – Published: 2018-04-26 15:00 – Updated: 2024-08-05 06:46
VLAI?
Summary
An issue was discovered on EDIMAX IC-3140W through 3.06, IC-5150W through 3.09, and IC-6220DC through 3.06 devices. The ipcam_cgi binary contains a stack-based buffer overflow that is possible to trigger from a remote unauthenticated /camera-cgi/public/getsysyeminfo.cgi?action=VALUE_HERE HTTP request: if the VALUE_HERE length is more than 0x400 (1024), it is possible to overwrite other values located on the stack due to an incorrect use of the strcpy() function.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:46:12.262Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.nemux.org/2018/04/24/cve-2018-8072/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-04-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on EDIMAX IC-3140W through 3.06, IC-5150W through 3.09, and IC-6220DC through 3.06 devices. The ipcam_cgi binary contains a stack-based buffer overflow that is possible to trigger from a remote unauthenticated /camera-cgi/public/getsysyeminfo.cgi?action=VALUE_HERE HTTP request: if the VALUE_HERE length is more than 0x400 (1024), it is possible to overwrite other values located on the stack due to an incorrect use of the strcpy() function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-04-26T14:57:02.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.nemux.org/2018/04/24/cve-2018-8072/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-8072",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on EDIMAX IC-3140W through 3.06, IC-5150W through 3.09, and IC-6220DC through 3.06 devices. The ipcam_cgi binary contains a stack-based buffer overflow that is possible to trigger from a remote unauthenticated /camera-cgi/public/getsysyeminfo.cgi?action=VALUE_HERE HTTP request: if the VALUE_HERE length is more than 0x400 (1024), it is possible to overwrite other values located on the stack due to an incorrect use of the strcpy() function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf",
              "refsource": "MISC",
              "url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf"
            },
            {
              "name": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt",
              "refsource": "MISC",
              "url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt"
            },
            {
              "name": "https://www.nemux.org/2018/04/24/cve-2018-8072/",
              "refsource": "MISC",
              "url": "https://www.nemux.org/2018/04/24/cve-2018-8072/"
            },
            {
              "name": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w",
              "refsource": "CONFIRM",
              "url": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-8072",
    "datePublished": "2018-04-26T15:00:00.000Z",
    "dateReserved": "2018-03-12T00:00:00.000Z",
    "dateUpdated": "2024-08-05T06:46:12.262Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-40597 (GCVE-0-2021-40597)

Vulnerability from cvelistv5 – Published: 2022-06-29 19:44 – Updated: 2024-08-04 02:44
VLAI?
Summary
The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:44:10.864Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-29T19:44:58.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-40597",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/",
              "refsource": "MISC",
              "url": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/"
            },
            {
              "name": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing",
              "refsource": "MISC",
              "url": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing"
            },
            {
              "name": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing",
              "refsource": "MISC",
              "url": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-40597",
    "datePublished": "2022-06-29T19:44:58.000Z",
    "dateReserved": "2021-09-07T00:00:00.000Z",
    "dateUpdated": "2024-08-04T02:44:10.864Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-30165 (GCVE-0-2021-30165)

Vulnerability from cvelistv5 – Published: 2021-04-27 03:07 – Updated: 2024-09-17 00:21
VLAI?
Title
EDIMAX Technology Co., Ltd. HD Wireless Day & Night Network Camera IC-3140W - Hard-coded password
Summary
The default administrator account & password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:24:59.557Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IC-3140W",
          "vendor": "EDIMAX Technology Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "3.11"
            }
          ]
        }
      ],
      "datePublic": "2021-04-27T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The default administrator account \u0026 password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-27T03:07:36.000Z",
        "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "shortName": "twcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update IC-3140W firmware to version 3.12"
        }
      ],
      "source": {
        "advisory": "TVN-202104001",
        "discovery": "EXTERNAL"
      },
      "title": "EDIMAX Technology Co., Ltd. HD Wireless Day \u0026 Night Network Camera IC-3140W - Hard-coded password",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "TWCERT/CC",
          "ASSIGNER": "cve@cert.org.tw",
          "DATE_PUBLIC": "2021-04-27T02:52:00.000Z",
          "ID": "CVE-2021-30165",
          "STATE": "PUBLIC",
          "TITLE": "EDIMAX Technology Co., Ltd. HD Wireless Day \u0026 Night Network Camera IC-3140W - Hard-coded password"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IC-3140W",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "3.11",
                            "version_value": "3.11"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "EDIMAX Technology Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The default administrator account \u0026 password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798 Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html",
              "refsource": "MISC",
              "url": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update IC-3140W firmware to version 3.12"
          }
        ],
        "source": {
          "advisory": "TVN-202104001",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
    "assignerShortName": "twcert",
    "cveId": "CVE-2021-30165",
    "datePublished": "2021-04-27T03:07:36.944Z",
    "dateReserved": "2021-04-06T00:00:00.000Z",
    "dateUpdated": "2024-09-17T00:21:26.883Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-26762 (GCVE-0-2020-26762)

Vulnerability from cvelistv5 – Published: 2020-12-01 14:56 – Updated: 2024-08-04 16:03
VLAI?
Summary
A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:03:21.672Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-01T14:56:08.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-26762",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w",
              "refsource": "CONFIRM",
              "url": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-26762",
    "datePublished": "2020-12-01T14:56:08.000Z",
    "dateReserved": "2020-10-07T00:00:00.000Z",
    "dateUpdated": "2024-08-04T16:03:21.672Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-8072 (GCVE-0-2018-8072)

Vulnerability from cvelistv5 – Published: 2018-04-26 15:00 – Updated: 2024-08-05 06:46
VLAI?
Summary
An issue was discovered on EDIMAX IC-3140W through 3.06, IC-5150W through 3.09, and IC-6220DC through 3.06 devices. The ipcam_cgi binary contains a stack-based buffer overflow that is possible to trigger from a remote unauthenticated /camera-cgi/public/getsysyeminfo.cgi?action=VALUE_HERE HTTP request: if the VALUE_HERE length is more than 0x400 (1024), it is possible to overwrite other values located on the stack due to an incorrect use of the strcpy() function.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:46:12.262Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.nemux.org/2018/04/24/cve-2018-8072/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-04-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on EDIMAX IC-3140W through 3.06, IC-5150W through 3.09, and IC-6220DC through 3.06 devices. The ipcam_cgi binary contains a stack-based buffer overflow that is possible to trigger from a remote unauthenticated /camera-cgi/public/getsysyeminfo.cgi?action=VALUE_HERE HTTP request: if the VALUE_HERE length is more than 0x400 (1024), it is possible to overwrite other values located on the stack due to an incorrect use of the strcpy() function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-04-26T14:57:02.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.nemux.org/2018/04/24/cve-2018-8072/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-8072",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on EDIMAX IC-3140W through 3.06, IC-5150W through 3.09, and IC-6220DC through 3.06 devices. The ipcam_cgi binary contains a stack-based buffer overflow that is possible to trigger from a remote unauthenticated /camera-cgi/public/getsysyeminfo.cgi?action=VALUE_HERE HTTP request: if the VALUE_HERE length is more than 0x400 (1024), it is possible to overwrite other values located on the stack due to an incorrect use of the strcpy() function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf",
              "refsource": "MISC",
              "url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf"
            },
            {
              "name": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt",
              "refsource": "MISC",
              "url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt"
            },
            {
              "name": "https://www.nemux.org/2018/04/24/cve-2018-8072/",
              "refsource": "MISC",
              "url": "https://www.nemux.org/2018/04/24/cve-2018-8072/"
            },
            {
              "name": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w",
              "refsource": "CONFIRM",
              "url": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-8072",
    "datePublished": "2018-04-26T15:00:00.000Z",
    "dateReserved": "2018-03-12T00:00:00.000Z",
    "dateUpdated": "2024-08-05T06:46:12.262Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}