Search criteria
8 vulnerabilities found for ic-3140w_firmware by edimax
CVE-2021-40597 (GCVE-0-2021-40597)
Vulnerability from nvd – Published: 2022-06-29 19:44 – Updated: 2024-08-04 02:44
VLAI?
Summary
The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:10.864Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-29T19:44:58.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-40597",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/",
"refsource": "MISC",
"url": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/"
},
{
"name": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing",
"refsource": "MISC",
"url": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing"
},
{
"name": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing",
"refsource": "MISC",
"url": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-40597",
"datePublished": "2022-06-29T19:44:58.000Z",
"dateReserved": "2021-09-07T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:44:10.864Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30165 (GCVE-0-2021-30165)
Vulnerability from nvd – Published: 2021-04-27 03:07 – Updated: 2024-09-17 00:21
VLAI?
Title
EDIMAX Technology Co., Ltd. HD Wireless Day & Night Network Camera IC-3140W - Hard-coded password
Summary
The default administrator account & password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices.
Severity ?
7.5 (High)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| EDIMAX Technology Co., Ltd. | IC-3140W |
Affected:
3.11
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.557Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IC-3140W",
"vendor": "EDIMAX Technology Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "3.11"
}
]
}
],
"datePublic": "2021-04-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The default administrator account \u0026 password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-27T03:07:36.000Z",
"orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"shortName": "twcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Update IC-3140W firmware to version 3.12"
}
],
"source": {
"advisory": "TVN-202104001",
"discovery": "EXTERNAL"
},
"title": "EDIMAX Technology Co., Ltd. HD Wireless Day \u0026 Night Network Camera IC-3140W - Hard-coded password",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"AKA": "TWCERT/CC",
"ASSIGNER": "cve@cert.org.tw",
"DATE_PUBLIC": "2021-04-27T02:52:00.000Z",
"ID": "CVE-2021-30165",
"STATE": "PUBLIC",
"TITLE": "EDIMAX Technology Co., Ltd. HD Wireless Day \u0026 Night Network Camera IC-3140W - Hard-coded password"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IC-3140W",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "3.11",
"version_value": "3.11"
}
]
}
}
]
},
"vendor_name": "EDIMAX Technology Co., Ltd."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The default administrator account \u0026 password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-798 Use of Hard-coded Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html",
"refsource": "MISC",
"url": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update IC-3140W firmware to version 3.12"
}
],
"source": {
"advisory": "TVN-202104001",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"assignerShortName": "twcert",
"cveId": "CVE-2021-30165",
"datePublished": "2021-04-27T03:07:36.944Z",
"dateReserved": "2021-04-06T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:21:26.883Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26762 (GCVE-0-2020-26762)
Vulnerability from nvd – Published: 2020-12-01 14:56 – Updated: 2024-08-04 16:03
VLAI?
Summary
A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:21.672Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-01T14:56:08.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26762",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w",
"refsource": "CONFIRM",
"url": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26762",
"datePublished": "2020-12-01T14:56:08.000Z",
"dateReserved": "2020-10-07T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:03:21.672Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-8072 (GCVE-0-2018-8072)
Vulnerability from nvd – Published: 2018-04-26 15:00 – Updated: 2024-08-05 06:46
VLAI?
Summary
An issue was discovered on EDIMAX IC-3140W through 3.06, IC-5150W through 3.09, and IC-6220DC through 3.06 devices. The ipcam_cgi binary contains a stack-based buffer overflow that is possible to trigger from a remote unauthenticated /camera-cgi/public/getsysyeminfo.cgi?action=VALUE_HERE HTTP request: if the VALUE_HERE length is more than 0x400 (1024), it is possible to overwrite other values located on the stack due to an incorrect use of the strcpy() function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:46:12.262Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.nemux.org/2018/04/24/cve-2018-8072/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-04-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on EDIMAX IC-3140W through 3.06, IC-5150W through 3.09, and IC-6220DC through 3.06 devices. The ipcam_cgi binary contains a stack-based buffer overflow that is possible to trigger from a remote unauthenticated /camera-cgi/public/getsysyeminfo.cgi?action=VALUE_HERE HTTP request: if the VALUE_HERE length is more than 0x400 (1024), it is possible to overwrite other values located on the stack due to an incorrect use of the strcpy() function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-26T14:57:02.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.nemux.org/2018/04/24/cve-2018-8072/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-8072",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on EDIMAX IC-3140W through 3.06, IC-5150W through 3.09, and IC-6220DC through 3.06 devices. The ipcam_cgi binary contains a stack-based buffer overflow that is possible to trigger from a remote unauthenticated /camera-cgi/public/getsysyeminfo.cgi?action=VALUE_HERE HTTP request: if the VALUE_HERE length is more than 0x400 (1024), it is possible to overwrite other values located on the stack due to an incorrect use of the strcpy() function."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf",
"refsource": "MISC",
"url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf"
},
{
"name": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt",
"refsource": "MISC",
"url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt"
},
{
"name": "https://www.nemux.org/2018/04/24/cve-2018-8072/",
"refsource": "MISC",
"url": "https://www.nemux.org/2018/04/24/cve-2018-8072/"
},
{
"name": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w",
"refsource": "CONFIRM",
"url": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-8072",
"datePublished": "2018-04-26T15:00:00.000Z",
"dateReserved": "2018-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:46:12.262Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-40597 (GCVE-0-2021-40597)
Vulnerability from cvelistv5 – Published: 2022-06-29 19:44 – Updated: 2024-08-04 02:44
VLAI?
Summary
The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:44:10.864Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-29T19:44:58.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-40597",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/",
"refsource": "MISC",
"url": "https://www.edimax.com/edimax/download/download/data/edimax/global/download/"
},
{
"name": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing",
"refsource": "MISC",
"url": "https://drive.google.com/file/d/1ZPFwAoO8tAD0zrWwVZ9W6-CUCrcM0Exm/view?usp=sharing"
},
{
"name": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing",
"refsource": "MISC",
"url": "https://drive.google.com/file/d/1DZCzVULjchY0rSJBXIPr0gJM1qWCcAZ5/view?usp=sharing"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-40597",
"datePublished": "2022-06-29T19:44:58.000Z",
"dateReserved": "2021-09-07T00:00:00.000Z",
"dateUpdated": "2024-08-04T02:44:10.864Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30165 (GCVE-0-2021-30165)
Vulnerability from cvelistv5 – Published: 2021-04-27 03:07 – Updated: 2024-09-17 00:21
VLAI?
Title
EDIMAX Technology Co., Ltd. HD Wireless Day & Night Network Camera IC-3140W - Hard-coded password
Summary
The default administrator account & password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices.
Severity ?
7.5 (High)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| EDIMAX Technology Co., Ltd. | IC-3140W |
Affected:
3.11
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.557Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IC-3140W",
"vendor": "EDIMAX Technology Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "3.11"
}
]
}
],
"datePublic": "2021-04-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The default administrator account \u0026 password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-27T03:07:36.000Z",
"orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"shortName": "twcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Update IC-3140W firmware to version 3.12"
}
],
"source": {
"advisory": "TVN-202104001",
"discovery": "EXTERNAL"
},
"title": "EDIMAX Technology Co., Ltd. HD Wireless Day \u0026 Night Network Camera IC-3140W - Hard-coded password",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"AKA": "TWCERT/CC",
"ASSIGNER": "cve@cert.org.tw",
"DATE_PUBLIC": "2021-04-27T02:52:00.000Z",
"ID": "CVE-2021-30165",
"STATE": "PUBLIC",
"TITLE": "EDIMAX Technology Co., Ltd. HD Wireless Day \u0026 Night Network Camera IC-3140W - Hard-coded password"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IC-3140W",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "3.11",
"version_value": "3.11"
}
]
}
}
]
},
"vendor_name": "EDIMAX Technology Co., Ltd."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The default administrator account \u0026 password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-798 Use of Hard-coded Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html",
"refsource": "MISC",
"url": "https://www.twcert.org.tw/tw/cp-132-4670-359c8-1.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update IC-3140W firmware to version 3.12"
}
],
"source": {
"advisory": "TVN-202104001",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"assignerShortName": "twcert",
"cveId": "CVE-2021-30165",
"datePublished": "2021-04-27T03:07:36.944Z",
"dateReserved": "2021-04-06T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:21:26.883Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26762 (GCVE-0-2020-26762)
Vulnerability from cvelistv5 – Published: 2020-12-01 14:56 – Updated: 2024-08-04 16:03
VLAI?
Summary
A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:21.672Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-01T14:56:08.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26762",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A stack-based buffer-overflow exists in Edimax IP-Camera IC-3116W (v3.06) and IC-3140W (v3.07), which allows an unauthenticated, unauthorized attacker to perform remote-code-execution due to a crafted GET-Request. The overflow occurs in binary ipcam_cgi due to a missing type check in function doGetSysteminfo(). This has been fixed in version: IC-3116W v3.08."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w",
"refsource": "CONFIRM",
"url": "https://www.edimax.com/edimax/download/download/data/edimax/de/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3116w"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26762",
"datePublished": "2020-12-01T14:56:08.000Z",
"dateReserved": "2020-10-07T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:03:21.672Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-8072 (GCVE-0-2018-8072)
Vulnerability from cvelistv5 – Published: 2018-04-26 15:00 – Updated: 2024-08-05 06:46
VLAI?
Summary
An issue was discovered on EDIMAX IC-3140W through 3.06, IC-5150W through 3.09, and IC-6220DC through 3.06 devices. The ipcam_cgi binary contains a stack-based buffer overflow that is possible to trigger from a remote unauthenticated /camera-cgi/public/getsysyeminfo.cgi?action=VALUE_HERE HTTP request: if the VALUE_HERE length is more than 0x400 (1024), it is possible to overwrite other values located on the stack due to an incorrect use of the strcpy() function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:46:12.262Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.nemux.org/2018/04/24/cve-2018-8072/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-04-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on EDIMAX IC-3140W through 3.06, IC-5150W through 3.09, and IC-6220DC through 3.06 devices. The ipcam_cgi binary contains a stack-based buffer overflow that is possible to trigger from a remote unauthenticated /camera-cgi/public/getsysyeminfo.cgi?action=VALUE_HERE HTTP request: if the VALUE_HERE length is more than 0x400 (1024), it is possible to overwrite other values located on the stack due to an incorrect use of the strcpy() function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-26T14:57:02.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.nemux.org/2018/04/24/cve-2018-8072/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-8072",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on EDIMAX IC-3140W through 3.06, IC-5150W through 3.09, and IC-6220DC through 3.06 devices. The ipcam_cgi binary contains a stack-based buffer overflow that is possible to trigger from a remote unauthenticated /camera-cgi/public/getsysyeminfo.cgi?action=VALUE_HERE HTTP request: if the VALUE_HERE length is more than 0x400 (1024), it is possible to overwrite other values located on the stack due to an incorrect use of the strcpy() function."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf",
"refsource": "MISC",
"url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/nemux_codemotion_Rome18_cover.pdf"
},
{
"name": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt",
"refsource": "MISC",
"url": "https://gitlab.com/nemux/CVE-2018-8072/blob/master/CVE-2018-8072_PoC.txt"
},
{
"name": "https://www.nemux.org/2018/04/24/cve-2018-8072/",
"refsource": "MISC",
"url": "https://www.nemux.org/2018/04/24/cve-2018-8072/"
},
{
"name": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w",
"refsource": "CONFIRM",
"url": "https://www.edimax.com/edimax/download/download/data/edimax/uk/download/for_home/home_network_cameras/home_network_cameras_indoor_fixed/ic-3140w"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-8072",
"datePublished": "2018-04-26T15:00:00.000Z",
"dateReserved": "2018-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:46:12.262Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}