Search

Find a vulnerability

Search criteria

    42 vulnerabilities found for factorytalk_linx by rockwellautomation

    FKIE_CVE-2025-9067

    Vulnerability from fkie_nvd - Published: 2025-10-14 13:15 - Updated: 2026-10-08 12:10
    Summary
    A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.
    Impacted products
    Vendor Product Version
    rockwellautomation factorytalk_linx *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk Linx",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.40 and prior"
                }
              ]
            }
          ],
          "source": "PSIRT@rockwellautomation.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "23BAB4E2-83AE-4C44-AE27-BFCF753D9BB5",
                  "versionEndExcluding": "6.50",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources."
        },
        {
          "lang": "es",
          "value": "Existe un problema de seguridad dentro del archivo de instalador de Microsoft (MSI) x86, instalado con FTLinx. Atacantes autenticados con credenciales de usuario de Windows v\u00e1lidas pueden iniciar una reparaci\u00f3n y secuestrar la ventana de consola resultante. Esto permite el lanzamiento de un s\u00edmbolo del sistema ejecut\u00e1ndose con privilegios de nivel SYSTEM, permitiendo acceso total a todos los archivos, procesos y recursos del sistema."
        }
      ],
      "id": "CVE-2025-9067",
      "lastModified": "2026-10-08T12:10:00.217",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "LOCAL",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.5,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "PSIRT@rockwellautomation.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-9067",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-10-14T18:50:13.723131Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-10-14T13:15:39.943",
      "references": [
        {
          "source": "PSIRT@rockwellautomation.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1754.html"
        }
      ],
      "sourceIdentifier": "PSIRT@rockwellautomation.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-269"
            }
          ],
          "source": "PSIRT@rockwellautomation.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2025-9068

    Vulnerability from fkie_nvd - Published: 2025-10-14 13:15 - Updated: 2026-10-08 12:10
    Summary
    A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.
    Impacted products
    Vendor Product Version
    rockwellautomation factorytalk_linx *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk Linx",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.40 and prior"
                }
              ]
            }
          ],
          "source": "PSIRT@rockwellautomation.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "23BAB4E2-83AE-4C44-AE27-BFCF753D9BB5",
                  "versionEndExcluding": "6.50",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources."
        },
        {
          "lang": "es",
          "value": "Existe una vulnerabilidad de seguridad dentro de la funcionalidad de reparaci\u00f3n del archivo de instalador de Microsoft (MSI) x64 del paquete de controladores de Rockwell Automation, instalado con FTLinx. Atacantes autenticados con credenciales v\u00e1lidas de usuarios de Windows pueden iniciar una reparaci\u00f3n y secuestrar la ventana de consola resultante para vbpinstall.exe. Esto permite el lanzamiento de un s\u00edmbolo del sistema ejecut\u00e1ndose con privilegios de nivel SYSTEM, permitiendo acceso total a todos los archivos, procesos y recursos del sistema."
        }
      ],
      "id": "CVE-2025-9068",
      "lastModified": "2026-10-08T12:10:00.217",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "LOCAL",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.5,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "PSIRT@rockwellautomation.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-9068",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-10-14T18:49:18.056590Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-10-14T13:15:40.093",
      "references": [
        {
          "source": "PSIRT@rockwellautomation.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1754.html"
        }
      ],
      "sourceIdentifier": "PSIRT@rockwellautomation.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-269"
            }
          ],
          "source": "PSIRT@rockwellautomation.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2025-7972

    Vulnerability from fkie_nvd - Published: 2025-08-14 15:15 - Updated: 2026-06-17 10:06
    Summary
    A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers.
    Impacted products
    Vendor Product Version
    rockwellautomation factorytalk_linx *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk\u00ae Linx",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "All prior to 6.50"
                }
              ]
            }
          ],
          "source": "PSIRT@rockwellautomation.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "23BAB4E2-83AE-4C44-AE27-BFCF753D9BB5",
                  "versionEndExcluding": "6.50",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to \u2018development\u2019, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers."
        },
        {
          "lang": "es",
          "value": "Existe un problema de seguridad en FactoryTalk Linx Network Browser. Al modificar process.env.NODE_ENV a \"development\", el atacante puede deshabilitar la validaci\u00f3n del token FTSP. Esta omisi\u00f3n permite el acceso para crear, actualizar y eliminar controladores FTLinx."
        }
      ],
      "id": "CVE-2025-7972",
      "lastModified": "2026-06-17T10:06:04.210",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.1,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "LOCAL",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.4,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "HIGH",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "HIGH",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "NONE",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "PSIRT@rockwellautomation.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-7972",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-08-14T15:06:45.964707Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-08-14T15:15:42.413",
      "references": [
        {
          "source": "PSIRT@rockwellautomation.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1735.html"
        }
      ],
      "sourceIdentifier": "PSIRT@rockwellautomation.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-286"
            }
          ],
          "source": "PSIRT@rockwellautomation.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-29464

    Vulnerability from fkie_nvd - Published: 2023-10-13 13:15 - Updated: 2026-06-17 05:50
    Summary
    FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk Linx ",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.20"
                },
                {
                  "status": "affected",
                  "version": "6.30"
                }
              ]
            }
          ],
          "source": "PSIRT@rockwellautomation.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.20:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "factorytalk_linx",
              "vendor": "rockwellautomation",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.20"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.30:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "factorytalk_linx",
              "vendor": "rockwellautomation",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.30"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.20:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D0753AB1-A633-4B8B-983E-1FA04EDDB2BD",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.30:*:*:*:*:*:*:*",
                  "matchCriteriaId": "22A83428-A3F4-45DD-95D2-D938CE82E4AE",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "\nFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\n\n"
        },
        {
          "lang": "es",
          "value": "FactoryTalk Linx, en Rockwell Automation PanelView Plus, permite que un actor de amenazas no autenticado lea datos de la memoria a trav\u00e9s de paquetes maliciosos manipulados. Enviar un tama\u00f1o mayor que el tama\u00f1o del b\u00fafer da como resultado una fuga de datos de la memoria, lo que resulta en una divulgaci\u00f3n de informaci\u00f3n. Si el tama\u00f1o es lo suficientemente grande, hace que las comunicaciones a trav\u00e9s del protocolo industrial com\u00fan dejen de responder a cualquier tipo de paquete, lo que resulta en una Denegaci\u00f3n de Servicio (DoS) para FactoryTalk Linx a trav\u00e9s del protocolo industrial com\u00fan."
        }
      ],
      "id": "CVE-2023-29464",
      "lastModified": "2026-06-17T05:50:07.017",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.2,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 4.2,
            "source": "PSIRT@rockwellautomation.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.1,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-29464",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-09-17T16:57:57.383746Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-10-13T13:15:11.453",
      "references": [
        {
          "source": "PSIRT@rockwellautomation.com",
          "tags": [
            "Permissions Required",
            "Vendor Advisory"
          ],
          "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Permissions Required",
            "Vendor Advisory"
          ],
          "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040"
        }
      ],
      "sourceIdentifier": "PSIRT@rockwellautomation.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "PSIRT@rockwellautomation.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-5806

    Vulnerability from fkie_nvd - Published: 2020-12-29 16:15 - Updated: 2026-06-17 03:22
    Summary
    An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
    Impacted products
    Vendor Product Version
    rockwellautomation factorytalk_linx *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "Rockwell FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions of FactoryTalk Linx"
                }
              ]
            }
          ],
          "source": "vulnreport@tenable.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "89622117-4485-4204-A5DA-B72F7F13D353",
                  "versionEndIncluding": "6.11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
        },
        {
          "lang": "es",
          "value": "Un tama\u00f1o de asignaci\u00f3n de memoria controlado por el atacante puede ser pasado al nuevo operador de C++ en la funci\u00f3n CServerManager::HandleBrowseLoadIconStreamRequest en la biblioteca messaging.dll. Esto se puede hacer mediante el env\u00edo de un mensaje especialmente dise\u00f1ado hacia 127.0.0.1:7153. Observado en FactoryTalk Linx versi\u00f3n 6.11. Todas las versiones de FactoryTalk Linx est\u00e1n afectadas"
        }
      ],
      "id": "CVE-2020-5806",
      "lastModified": "2026-06-17T03:22:16.310",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "LOW",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 2.1,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-12-29T16:15:14.887",
      "references": [
        {
          "source": "vulnreport@tenable.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/research/tra-2020-71"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/research/tra-2020-71"
        }
      ],
      "sourceIdentifier": "vulnreport@tenable.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-770"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-5802

    Vulnerability from fkie_nvd - Published: 2020-12-29 16:15 - Updated: 2026-06-17 03:22
    Summary
    An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected.
    Impacted products
    Vendor Product Version
    rockwellautomation factorytalk_linx *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "Rockwell FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions of FactoryTalk Linx"
                }
              ]
            }
          ],
          "source": "vulnreport@tenable.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "89622117-4485-4204-A5DA-B72F7F13D353",
                  "versionEndIncluding": "6.11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected."
        },
        {
          "lang": "es",
          "value": "Un tama\u00f1o de asignaci\u00f3n de memoria controlado por el atacante puede ser pasado al nuevo operador de C++ en la biblioteca RnaDaSvr.dll mediante el env\u00edo de un mensaje ConfigureItems especialmente dise\u00f1ado hacia el puerto TCP 4241. Esto causar\u00e1 una excepci\u00f3n no manejada, resultando en la terminaci\u00f3n del archivo RSLinxNG.exe. Observado en FactoryTalk versi\u00f3n 6.11. Todas las versiones de FactoryTalk Linx est\u00e1n afectadas"
        }
      ],
      "id": "CVE-2020-5802",
      "lastModified": "2026-06-17T03:22:15.813",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-12-29T16:15:14.840",
      "references": [
        {
          "source": "vulnreport@tenable.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/research/tra-2020-71"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/research/tra-2020-71"
        }
      ],
      "sourceIdentifier": "vulnreport@tenable.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-770"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-5801

    Vulnerability from fkie_nvd - Published: 2020-12-29 16:15 - Updated: 2026-06-17 03:22
    Summary
    An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
    Impacted products
    Vendor Product Version
    rockwellautomation factorytalk_linx *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "Rockwell FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions of FactoryTalk Linx"
                }
              ]
            }
          ],
          "source": "vulnreport@tenable.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "89622117-4485-4204-A5DA-B72F7F13D353",
                  "versionEndIncluding": "6.11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
        },
        {
          "lang": "es",
          "value": "Un atacante puede crear y enviar un mensaje OpenNamespace al puerto 4241 con un ID de sesi\u00f3n v\u00e1lido que desencadena una excepci\u00f3n no controlada en la funci\u00f3n CFTLDManager::HandleRequest en la biblioteca RnaDaSvr.dll, resultando en una terminaci\u00f3n del proceso.\u0026#xa0;Observado en FactoryTalk Linx versi\u00f3n 6.11.\u0026#xa0;Todas las versiones de FactoryTalk Linx est\u00e1n afectadas"
        }
      ],
      "id": "CVE-2020-5801",
      "lastModified": "2026-06-17T03:22:15.710",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-12-29T16:15:14.730",
      "references": [
        {
          "source": "vulnreport@tenable.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/research/tra-2020-71"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/research/tra-2020-71"
        }
      ],
      "sourceIdentifier": "vulnreport@tenable.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-755"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-27255

    Vulnerability from fkie_nvd - Published: 2020-11-26 02:15 - Updated: 2026-06-17 03:09
    Summary
    A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious set attribute requests, which could result in the leaking of sensitive information. This information disclosure could lead to the bypass of address space layout randomization (ASLR).
    References
    Impacted products
    Vendor Product Version
    rockwellautomation factorytalk_linx *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 6.11 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "89622117-4485-4204-A5DA-B72F7F13D353",
                  "versionEndIncluding": "6.11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious set attribute requests, which could result in the leaking of sensitive information. This information disclosure could lead to the bypass of address space layout randomization (ASLR)."
        },
        {
          "lang": "es",
          "value": "Se presenta una vulnerabilidad de desbordamiento de la pila en FactoryTalk Linx versiones 6.11 y anteriores.\u0026#xa0;Esta vulnerabilidad podr\u00eda permitir a un atacante remoto no autenticado enviar peticiones de atributos de configuraci\u00f3n maliciosos, lo que podr\u00eda resultar en un filtrado de informaci\u00f3n confidencial.\u0026#xa0;Esta divulgaci\u00f3n de informaci\u00f3n podr\u00eda conllevar a una omisi\u00f3n de la aleatorizaci\u00f3n del dise\u00f1o de espacio de direcciones (ASLR)"
        }
      ],
      "id": "CVE-2020-27255",
      "lastModified": "2026-06-17T03:09:03.680",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-11-26T02:15:12.243",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-122"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2020-27253

    Vulnerability from fkie_nvd - Published: 2020-11-26 02:15 - Updated: 2026-06-17 03:09
    Summary
    A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device.
    References
    Impacted products
    Vendor Product Version
    rockwellautomation factorytalk_linx *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 6.11 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "89622117-4485-4204-A5DA-B72F7F13D353",
                  "versionEndIncluding": "6.11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device."
        },
        {
          "lang": "es",
          "value": "Se presenta un fallo en la rutina de comprobaci\u00f3n de Ingresos y Egresos de FactoryTalk Linx Versiones 6.11 y anteriores.\u0026#xa0;Esta vulnerabilidad podr\u00eda permitir a un atacante remoto, no autenticado, dise\u00f1ar espec\u00edficamente un paquete malicioso resultando en una condici\u00f3n de denegaci\u00f3n de servicio en el dispositivo"
        }
      ],
      "id": "CVE-2020-27253",
      "lastModified": "2026-06-17T03:09:03.480",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 7.8,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-11-26T02:15:12.183",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2020-27251

    Vulnerability from fkie_nvd - Published: 2020-11-26 02:15 - Updated: 2026-06-17 03:09
    Summary
    A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution.
    References
    Impacted products
    Vendor Product Version
    rockwellautomation factorytalk_linx *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 6.11 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "89622117-4485-4204-A5DA-B72F7F13D353",
                  "versionEndIncluding": "6.11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution."
        },
        {
          "lang": "es",
          "value": "Se presenta una vulnerabilidad de desbordamiento de la pila en FactoryTalk Linx Versiones 6.11 y anteriores.\u0026#xa0;Esta vulnerabilidad podr\u00eda permitir a un atacante remoto no autenticado enviar rangos de puertos maliciosos, lo que podr\u00eda resultar en una ejecuci\u00f3n de c\u00f3digo remota"
        }
      ],
      "id": "CVE-2020-27251",
      "lastModified": "2026-06-17T03:09:03.237",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-11-26T02:15:12.010",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-122"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2020-12005

    Vulnerability from fkie_nvd - Published: 2020-06-15 20:15 - Updated: 2026-06-17 02:51
    Summary
    FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.
    References

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.00:*:*:*:*:*:*:*",
                  "matchCriteriaId": "244B67F2-DEC2-44E2-94F1-F6A82249453C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "767F223A-C4CE-49DE-B66F-51345E91C98F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.11:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5675EA61-1854-4AA1-BA1B-E07442E1F10C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:rslinx_classic:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4F6780E2-AB8D-4860-812F-CBE82A94EF0D",
                  "versionEndIncluding": "4.11.00",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition."
        },
        {
          "lang": "es",
          "value": "FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versi\u00f3n 12 y anteriores, ControlFLASH: versi\u00f3n 14 y posteriores, ControlFLASH Plus: versi\u00f3n 1 y posteriores, FactoryTalk Asset Center: versi\u00f3n 9 y posteriores , FactoryTalk Linx CommDTM: versi\u00f3n 1 y posteriores, Studio 5000 Launcher: versi\u00f3n 31 y posteriores a Stud, software 5000 Logix Designer: versi\u00f3n 32 y anteriores son vulnerables. Se presenta una vulnerabilidad en la funci\u00f3n de comunicaci\u00f3n que permite a los usuarios cargar archivos EDS mediante FactoryTalk Linx. Esto puede permitir a un atacante cargar un archivo con mala compresi\u00f3n, consumiendo todos los recursos de CPU disponibles, conllevando a una condici\u00f3n de denegaci\u00f3n de servicio"
        }
      ],
      "id": "CVE-2020-12005",
      "lastModified": "2026-06-17T02:51:14.337",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 7.8,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-06-15T20:15:11.473",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-434"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-434"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-12003

    Vulnerability from fkie_nvd - Published: 2020-06-15 20:15 - Updated: 2026-06-17 02:51
    Summary
    FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.
    References

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.00:*:*:*:*:*:*:*",
                  "matchCriteriaId": "244B67F2-DEC2-44E2-94F1-F6A82249453C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "767F223A-C4CE-49DE-B66F-51345E91C98F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.11:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5675EA61-1854-4AA1-BA1B-E07442E1F10C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:rslinx_classic:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4F6780E2-AB8D-4860-812F-CBE82A94EF0D",
                  "versionEndIncluding": "4.11.00",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive."
        },
        {
          "lang": "es",
          "value": "FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versi\u00f3n 12 y anteriores, ControlFLASH: versi\u00f3n 14 y posteriores, ControlFLASH Plus: versi\u00f3n 1 y posteriores, FactoryTalk Asset Center: versi\u00f3n 9 y posteriores , FactoryTalk Linx CommDTM: versi\u00f3n 1 y posteriores, Studio 5000 Launcher: versi\u00f3n 31 y posteriores a Stud, software 5000 Logix Designer: versi\u00f3n 32 y anteriores son vulnerables. Una llamada expuesta de la API permite a los usuarios proporcionar archivos a ser procesados sin saneamiento. Esto puede permitir a un atacante usar peticiones especialmente dise\u00f1adas para saltar el sistema de archivos y exponer datos confidenciales en el disco duro local"
        }
      ],
      "id": "CVE-2020-12003",
      "lastModified": "2026-06-17T02:51:14.130",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-06-15T20:15:11.397",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-12001

    Vulnerability from fkie_nvd - Published: 2020-06-15 20:15 - Updated: 2026-06-17 02:51
    Summary
    FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.00:*:*:*:*:*:*:*",
                  "matchCriteriaId": "244B67F2-DEC2-44E2-94F1-F6A82249453C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "767F223A-C4CE-49DE-B66F-51345E91C98F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.11:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5675EA61-1854-4AA1-BA1B-E07442E1F10C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:rslinx_classic:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4F6780E2-AB8D-4860-812F-CBE82A94EF0D",
                  "versionEndIncluding": "4.11.00",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code."
        },
        {
          "lang": "es",
          "value": "FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versi\u00f3n 12 y anteriores, ControlFLASH: versi\u00f3n 14 y posteriores, ControlFLASH Plus: versi\u00f3n 1 y posteriores, FactoryTalk Asset Center: versi\u00f3n 9 y posteriores , FactoryTalk Linx CommDTM: versi\u00f3n 1 y posteriores, Studio 5000 Launcher: versi\u00f3n 31 y posteriores a Stud, software 5000 Logix Designer: versi\u00f3n 32 y anteriores son vulnerables. El mecanismo de an\u00e1lisis que procesa determinados tipos de archivos no proporciona un saneamiento de entrada. Esto puede permitir a un atacante usar archivos especialmente dise\u00f1ados para atravesar el sistema de archivos y modificar o exponer datos confidenciales o ejecutar c\u00f3digo arbitrario"
        }
      ],
      "id": "CVE-2020-12001",
      "lastModified": "2026-06-17T02:51:13.887",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-06-15T20:15:11.317",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-733/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-733/"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-11999

    Vulnerability from fkie_nvd - Published: 2020-06-15 20:15 - Updated: 2026-06-17 02:51
    Summary
    FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data.
    References

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.00:*:*:*:*:*:*:*",
                  "matchCriteriaId": "244B67F2-DEC2-44E2-94F1-F6A82249453C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "767F223A-C4CE-49DE-B66F-51345E91C98F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.11:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5675EA61-1854-4AA1-BA1B-E07442E1F10C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rockwellautomation:rslinx_classic:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4F6780E2-AB8D-4860-812F-CBE82A94EF0D",
                  "versionEndIncluding": "4.11.00",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data."
        },
        {
          "lang": "es",
          "value": "FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versi\u00f3n 12 y anteriores, ControlFLASH: versi\u00f3n 14 y posteriores, ControlFLASH Plus: versi\u00f3n 1 y posteriores, FactoryTalk Asset Center: versi\u00f3n 9 y posteriores , FactoryTalk Linx CommDTM: versi\u00f3n 1 y posteriores, Studio 5000 Launcher: versi\u00f3n 31 y posteriores a Stud, software 5000 Logix Designer: versi\u00f3n 32 y anteriores son vulnerables. Una llamada expuesta de la API permite a los usuarios proporcionar archivos a ser procesados sin saneamiento. Esto puede permitir a un atacante especificar un nombre de archivo para ejecutar c\u00f3digo no autorizado y modificar archivos o datos"
        }
      ],
      "id": "CVE-2020-11999",
      "lastModified": "2026-06-17T02:51:13.667",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 4.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 8.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-06-15T20:15:11.223",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2025-9068 (GCVE-0-2025-9068)

    Vulnerability from nvd – Published: 2025-10-14 12:23 – Updated: 2025-10-14 18:49
    VLAI
    Title
    Rockwell Automation FactoryTalk® Linx Privilege Escalation Vulnerabilities
    Summary
    A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-14 18:49 UTC
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    Rockwell CNA under the icscert root
    CNA scorecard C 74/100 over 47 records in the last 180 days details
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9068",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-14T18:49:18.056590Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-14T18:49:27.564Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk Linx",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.40 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources. \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
                }
              ],
              "value": "A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269: Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-14T12:23:45.550Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1754.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "6.50 and later"
                }
              ],
              "value": "6.50 and later"
            }
          ],
          "source": {
            "advisory": "SD1754",
            "discovery": "INTERNAL"
          },
          "title": "Rockwell Automation FactoryTalk\u00ae Linx Privilege Escalation Vulnerabilities",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2025-9068",
        "datePublished": "2025-10-14T12:23:45.550Z",
        "dateReserved": "2025-08-15T14:20:47.449Z",
        "dateUpdated": "2025-10-14T18:49:27.564Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-9067 (GCVE-0-2025-9067)

    Vulnerability from nvd – Published: 2025-10-14 12:24 – Updated: 2025-10-14 18:50
    VLAI
    Title
    Rockwell Automation FactoryTalk® Linx Privilege Escalation Vulnerabilities
    Summary
    A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-14 18:50 UTC
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    Rockwell CNA under the icscert root
    CNA scorecard C 74/100 over 47 records in the last 180 days details
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9067",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-14T18:50:13.723131Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-14T18:50:28.594Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk Linx",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.40 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
                }
              ],
              "value": "A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269: Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-14T12:24:45.641Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1754.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "6.50 and later"
                }
              ],
              "value": "6.50 and later"
            }
          ],
          "source": {
            "advisory": "SD1754",
            "discovery": "INTERNAL"
          },
          "title": "Rockwell Automation FactoryTalk\u00ae Linx Privilege Escalation Vulnerabilities",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2025-9067",
        "datePublished": "2025-10-14T12:24:45.641Z",
        "dateReserved": "2025-08-15T14:19:50.492Z",
        "dateUpdated": "2025-10-14T18:50:28.594Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-7972 (GCVE-0-2025-7972)

    Vulnerability from nvd – Published: 2025-08-14 14:47 – Updated: 2025-08-14 15:08
    VLAI
    Title
    Rockwell Automation FactoryTalk® Linx Network Browser Security Bypass Vulnerability
    Summary
    A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-14 15:06 UTC
    CWE
    • CWE-286 - Incorrect User Management
    Assigner
    Rockwell CNA under the icscert root
    CNA scorecard C 74/100 over 47 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Rockwell Automation FactoryTalk® Linx Affected: All prior to 6.50
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7972",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-14T15:06:45.964707Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-14T15:08:22.952Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk\u00ae Linx",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "All prior to 6.50"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to \u2018development\u2019, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers. \u003c/span\u003e"
                }
              ],
              "value": "A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to \u2018development\u2019, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-286",
                  "description": "CWE-286: Incorrect User Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-14T14:54:29.154Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1735.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to version 6.50 or later."
                }
              ],
              "value": "Upgrade to version 6.50 or later."
            }
          ],
          "source": {
            "advisory": "SD1735",
            "discovery": "INTERNAL"
          },
          "title": "Rockwell Automation FactoryTalk\u00ae Linx Network Browser Security Bypass Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2025-7972",
        "datePublished": "2025-08-14T14:47:46.316Z",
        "dateReserved": "2025-07-21T19:25:20.271Z",
        "dateUpdated": "2025-08-14T15:08:22.952Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-29464 (GCVE-0-2023-29464)

    Vulnerability from nvd – Published: 2023-10-13 12:57 – Updated: 2024-09-17 16:58
    VLAI
    Title
    Rockwell Automation FactoryTalk Linx Vulnerable to Denial-of-Service and Information Disclosure
    Summary
    FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-09-17 16:57 UTC
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    Rockwell CNA under the icscert root
    CNA scorecard C 74/100 over 47 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Rockwell Automation FactoryTalk Linx Affected: 6.20
    Affected: 6.30
    Create a notification for this product.
    rockwellautomation factorytalk_linx Affected: 6.20
        cpe:2.3:a:rockwellautomation:factorytalk_linx:6.20:*:*:*:*:*:*:*
    Create a notification for this product.
    rockwellautomation factorytalk_linx Affected: 6.30
        cpe:2.3:a:rockwellautomation:factorytalk_linx:6.30:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-10-12 14:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:07:46.248Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.20:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "factorytalk_linx",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "6.20"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.30:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "factorytalk_linx",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "6.30"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-29464",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-17T16:57:57.383746Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-17T16:58:55.796Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk Linx ",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.20"
                },
                {
                  "status": "affected",
                  "version": "6.30"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Rockwell Automation would like to thank Yuval Gordon, CPS Research, Microsoft Threat Intelligence Community for reporting this vulnerability to us."
            }
          ],
          "datePublic": "2023-10-12T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-10",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-10 Buffer Overflow via Environment Variables"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-13T12:57:25.490Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cul\u003e\u003cli\u003eInstall the security patches for the respective versions, referencing \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140402\"\u003eBF29637 - Patch: Hardening of the FactoryTalk Linx communications service for MobileView to authenticate and block improperly sized files, FactoryTalk Linx 6.20, 6.30\u003c/a\u003e.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n  *  Install the security patches for the respective versions, referencing  BF29637 - Patch: Hardening of the FactoryTalk Linx communications service for MobileView to authenticate and block improperly sized files, FactoryTalk Linx 6.20, 6.30 https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140402 .\n\n\n\n\n\n"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Rockwell Automation FactoryTalk Linx Vulnerable to Denial-of-Service and Information Disclosure",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2023-29464",
        "datePublished": "2023-10-13T12:57:25.490Z",
        "dateReserved": "2023-04-06T18:42:59.008Z",
        "dateUpdated": "2024-09-17T16:58:55.796Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5806 (GCVE-0-2020-5806)

    Vulnerability from nvd – Published: 2020-12-29 15:08 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
    Severity
    No CVSS data available.
    CWE
    • Local Denial of Service
    Assigner
    tenable CNA under the mitre root
    CNA scorecard C 73/100 over 40 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a Rockwell FactoryTalk Linx Affected: All versions of FactoryTalk Linx
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.924Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-71"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Rockwell FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions of FactoryTalk Linx"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Local Denial of Service",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-29T15:08:36.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-71"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5806",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Rockwell FactoryTalk Linx",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions of FactoryTalk Linx"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Local Denial of Service"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-71",
                  "refsource": "CONFIRM",
                  "url": "https://www.tenable.com/security/research/tra-2020-71"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5806",
        "datePublished": "2020-12-29T15:08:36.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.924Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5802 (GCVE-0-2020-5802)

    Vulnerability from nvd – Published: 2020-12-29 15:04 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected.
    Severity
    No CVSS data available.
    CWE
    • Unauthenticated Remote Denial of Service
    Assigner
    tenable CNA under the mitre root
    CNA scorecard C 73/100 over 40 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a Rockwell FactoryTalk Linx Affected: All versions of FactoryTalk Linx
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.932Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-71"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Rockwell FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions of FactoryTalk Linx"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Unauthenticated Remote Denial of Service",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-29T15:04:26.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-71"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5802",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Rockwell FactoryTalk Linx",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions of FactoryTalk Linx"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Unauthenticated Remote Denial of Service"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-71",
                  "refsource": "CONFIRM",
                  "url": "https://www.tenable.com/security/research/tra-2020-71"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5802",
        "datePublished": "2020-12-29T15:04:26.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5801 (GCVE-0-2020-5801)

    Vulnerability from nvd – Published: 2020-12-29 15:15 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
    Severity
    No CVSS data available.
    CWE
    • Unauthenticated Remote DoS
    Assigner
    tenable CNA under the mitre root
    CNA scorecard C 73/100 over 40 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a Rockwell FactoryTalk Linx Affected: All versions of FactoryTalk Linx
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:26.067Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-71"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Rockwell FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions of FactoryTalk Linx"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Unauthenticated Remote DoS",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-29T15:15:32.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-71"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5801",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Rockwell FactoryTalk Linx",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions of FactoryTalk Linx"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Unauthenticated Remote DoS"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-71",
                  "refsource": "CONFIRM",
                  "url": "https://www.tenable.com/security/research/tra-2020-71"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5801",
        "datePublished": "2020-12-29T15:15:32.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:26.067Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-27255 (GCVE-0-2020-27255)

    Vulnerability from nvd – Published: 2020-11-26 01:38 – Updated: 2024-08-04 16:11
    VLAI
    Summary
    A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious set attribute requests, which could result in the leaking of sensitive information. This information disclosure could lead to the bypass of address space layout randomization (ASLR).
    Severity
    No CVSS data available.
    CWE
    • CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 336 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a FactoryTalk Linx Affected: Version 6.11 and prior
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:11:36.395Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 6.11 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious set attribute requests, which could result in the leaking of sensitive information. This information disclosure could lead to the bypass of address space layout randomization (ASLR)."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-11-26T01:38:44.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-27255",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "FactoryTalk Linx",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version 6.11 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious set attribute requests, which could result in the leaking of sensitive information. This information disclosure could lead to the bypass of address space layout randomization (ASLR)."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-27255",
        "datePublished": "2020-11-26T01:38:44.000Z",
        "dateReserved": "2020-10-19T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:11:36.395Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-27253 (GCVE-0-2020-27253)

    Vulnerability from nvd – Published: 2020-11-26 01:36 – Updated: 2024-08-04 16:11
    VLAI
    Summary
    A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device.
    Severity
    No CVSS data available.
    CWE
    • CWE-20 - IMPROPER INPUT VALIDATION CWE-20
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 336 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a FactoryTalk Linx Affected: Version 6.11 and prior
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:11:36.421Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 6.11 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "IMPROPER INPUT VALIDATION CWE-20",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-11-26T01:36:27.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-27253",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "FactoryTalk Linx",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version 6.11 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "IMPROPER INPUT VALIDATION CWE-20"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-27253",
        "datePublished": "2020-11-26T01:36:27.000Z",
        "dateReserved": "2020-10-19T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:11:36.421Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-9067 (GCVE-0-2025-9067)

    Vulnerability from cvelistv5 – Published: 2025-10-14 12:24 – Updated: 2025-10-14 18:50
    VLAI
    Title
    Rockwell Automation FactoryTalk® Linx Privilege Escalation Vulnerabilities
    Summary
    A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-14 18:50 UTC
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    Rockwell CNA under the icscert root
    CNA scorecard C 74/100 over 47 records in the last 180 days details
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9067",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-14T18:50:13.723131Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-14T18:50:28.594Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk Linx",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.40 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
                }
              ],
              "value": "A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269: Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-14T12:24:45.641Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1754.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "6.50 and later"
                }
              ],
              "value": "6.50 and later"
            }
          ],
          "source": {
            "advisory": "SD1754",
            "discovery": "INTERNAL"
          },
          "title": "Rockwell Automation FactoryTalk\u00ae Linx Privilege Escalation Vulnerabilities",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2025-9067",
        "datePublished": "2025-10-14T12:24:45.641Z",
        "dateReserved": "2025-08-15T14:19:50.492Z",
        "dateUpdated": "2025-10-14T18:50:28.594Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-9068 (GCVE-0-2025-9068)

    Vulnerability from cvelistv5 – Published: 2025-10-14 12:23 – Updated: 2025-10-14 18:49
    VLAI
    Title
    Rockwell Automation FactoryTalk® Linx Privilege Escalation Vulnerabilities
    Summary
    A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-14 18:49 UTC
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    Rockwell CNA under the icscert root
    CNA scorecard C 74/100 over 47 records in the last 180 days details
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9068",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-14T18:49:18.056590Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-14T18:49:27.564Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk Linx",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.40 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources. \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
                }
              ],
              "value": "A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269: Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-14T12:23:45.550Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1754.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "6.50 and later"
                }
              ],
              "value": "6.50 and later"
            }
          ],
          "source": {
            "advisory": "SD1754",
            "discovery": "INTERNAL"
          },
          "title": "Rockwell Automation FactoryTalk\u00ae Linx Privilege Escalation Vulnerabilities",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2025-9068",
        "datePublished": "2025-10-14T12:23:45.550Z",
        "dateReserved": "2025-08-15T14:20:47.449Z",
        "dateUpdated": "2025-10-14T18:49:27.564Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-7972 (GCVE-0-2025-7972)

    Vulnerability from cvelistv5 – Published: 2025-08-14 14:47 – Updated: 2025-08-14 15:08
    VLAI
    Title
    Rockwell Automation FactoryTalk® Linx Network Browser Security Bypass Vulnerability
    Summary
    A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-14 15:06 UTC
    CWE
    • CWE-286 - Incorrect User Management
    Assigner
    Rockwell CNA under the icscert root
    CNA scorecard C 74/100 over 47 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Rockwell Automation FactoryTalk® Linx Affected: All prior to 6.50
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7972",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-14T15:06:45.964707Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-14T15:08:22.952Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk\u00ae Linx",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "All prior to 6.50"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to \u2018development\u2019, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers. \u003c/span\u003e"
                }
              ],
              "value": "A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to \u2018development\u2019, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-286",
                  "description": "CWE-286: Incorrect User Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-14T14:54:29.154Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1735.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to version 6.50 or later."
                }
              ],
              "value": "Upgrade to version 6.50 or later."
            }
          ],
          "source": {
            "advisory": "SD1735",
            "discovery": "INTERNAL"
          },
          "title": "Rockwell Automation FactoryTalk\u00ae Linx Network Browser Security Bypass Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2025-7972",
        "datePublished": "2025-08-14T14:47:46.316Z",
        "dateReserved": "2025-07-21T19:25:20.271Z",
        "dateUpdated": "2025-08-14T15:08:22.952Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-29464 (GCVE-0-2023-29464)

    Vulnerability from cvelistv5 – Published: 2023-10-13 12:57 – Updated: 2024-09-17 16:58
    VLAI
    Title
    Rockwell Automation FactoryTalk Linx Vulnerable to Denial-of-Service and Information Disclosure
    Summary
    FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-09-17 16:57 UTC
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    Rockwell CNA under the icscert root
    CNA scorecard C 74/100 over 47 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Rockwell Automation FactoryTalk Linx Affected: 6.20
    Affected: 6.30
    Create a notification for this product.
    rockwellautomation factorytalk_linx Affected: 6.20
        cpe:2.3:a:rockwellautomation:factorytalk_linx:6.20:*:*:*:*:*:*:*
    Create a notification for this product.
    rockwellautomation factorytalk_linx Affected: 6.30
        cpe:2.3:a:rockwellautomation:factorytalk_linx:6.30:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-10-12 14:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:07:46.248Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.20:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "factorytalk_linx",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "6.20"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.30:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "factorytalk_linx",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "6.30"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-29464",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-17T16:57:57.383746Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-17T16:58:55.796Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk Linx ",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.20"
                },
                {
                  "status": "affected",
                  "version": "6.30"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Rockwell Automation would like to thank Yuval Gordon, CPS Research, Microsoft Threat Intelligence Community for reporting this vulnerability to us."
            }
          ],
          "datePublic": "2023-10-12T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-10",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-10 Buffer Overflow via Environment Variables"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-13T12:57:25.490Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cul\u003e\u003cli\u003eInstall the security patches for the respective versions, referencing \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140402\"\u003eBF29637 - Patch: Hardening of the FactoryTalk Linx communications service for MobileView to authenticate and block improperly sized files, FactoryTalk Linx 6.20, 6.30\u003c/a\u003e.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n  *  Install the security patches for the respective versions, referencing  BF29637 - Patch: Hardening of the FactoryTalk Linx communications service for MobileView to authenticate and block improperly sized files, FactoryTalk Linx 6.20, 6.30 https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140402 .\n\n\n\n\n\n"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Rockwell Automation FactoryTalk Linx Vulnerable to Denial-of-Service and Information Disclosure",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2023-29464",
        "datePublished": "2023-10-13T12:57:25.490Z",
        "dateReserved": "2023-04-06T18:42:59.008Z",
        "dateUpdated": "2024-09-17T16:58:55.796Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5801 (GCVE-0-2020-5801)

    Vulnerability from cvelistv5 – Published: 2020-12-29 15:15 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
    Severity
    No CVSS data available.
    CWE
    • Unauthenticated Remote DoS
    Assigner
    tenable CNA under the mitre root
    CNA scorecard C 73/100 over 40 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a Rockwell FactoryTalk Linx Affected: All versions of FactoryTalk Linx
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:26.067Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-71"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Rockwell FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions of FactoryTalk Linx"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Unauthenticated Remote DoS",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-29T15:15:32.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-71"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5801",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Rockwell FactoryTalk Linx",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions of FactoryTalk Linx"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Unauthenticated Remote DoS"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-71",
                  "refsource": "CONFIRM",
                  "url": "https://www.tenable.com/security/research/tra-2020-71"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5801",
        "datePublished": "2020-12-29T15:15:32.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:26.067Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5806 (GCVE-0-2020-5806)

    Vulnerability from cvelistv5 – Published: 2020-12-29 15:08 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
    Severity
    No CVSS data available.
    CWE
    • Local Denial of Service
    Assigner
    tenable CNA under the mitre root
    CNA scorecard C 73/100 over 40 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a Rockwell FactoryTalk Linx Affected: All versions of FactoryTalk Linx
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.924Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-71"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Rockwell FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions of FactoryTalk Linx"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Local Denial of Service",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-29T15:08:36.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-71"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5806",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Rockwell FactoryTalk Linx",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions of FactoryTalk Linx"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Local Denial of Service"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-71",
                  "refsource": "CONFIRM",
                  "url": "https://www.tenable.com/security/research/tra-2020-71"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5806",
        "datePublished": "2020-12-29T15:08:36.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.924Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5802 (GCVE-0-2020-5802)

    Vulnerability from cvelistv5 – Published: 2020-12-29 15:04 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected.
    Severity
    No CVSS data available.
    CWE
    • Unauthenticated Remote Denial of Service
    Assigner
    tenable CNA under the mitre root
    CNA scorecard C 73/100 over 40 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a Rockwell FactoryTalk Linx Affected: All versions of FactoryTalk Linx
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.932Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-71"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Rockwell FactoryTalk Linx",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions of FactoryTalk Linx"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Unauthenticated Remote Denial of Service",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-29T15:04:26.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-71"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5802",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Rockwell FactoryTalk Linx",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions of FactoryTalk Linx"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Unauthenticated Remote Denial of Service"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-71",
                  "refsource": "CONFIRM",
                  "url": "https://www.tenable.com/security/research/tra-2020-71"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5802",
        "datePublished": "2020-12-29T15:04:26.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }