Search
Find a vulnerability
Search criteria
12 vulnerabilities found for ex300_v2_firmware by totolink
CVE-2022-32449 (GCVE-0-2022-32449)
Vulnerability from nvd – Published: 2022-07-07 00:00 – Updated: 2024-08-03 07:39
VLAI
Summary
TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:39:51.043Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-01T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
},
{
"url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-32449",
"datePublished": "2022-07-07T00:00:00.000Z",
"dateReserved": "2022-06-05T00:00:00.000Z",
"dateUpdated": "2024-08-03T07:39:51.043Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-43663 (GCVE-0-2021-43663)
Vulnerability from nvd – Published: 2022-03-30 23:40 – Updated: 2024-08-04 04:03
VLAI
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/chibataiki/iot-vuls/blob/main/… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:03:08.611Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-30T23:40:13.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-43663",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md",
"refsource": "MISC",
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-43663",
"datePublished": "2022-03-30T23:40:13.000Z",
"dateReserved": "2021-11-15T00:00:00.000Z",
"dateUpdated": "2024-08-04T04:03:08.611Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-43662 (GCVE-0-2021-43662)
Vulnerability from nvd – Published: 2022-03-30 23:26 – Updated: 2024-08-04 04:03
VLAI
Summary
totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/chibataiki/iot-vuls/blob/main/… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:03:08.137Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-30T23:26:03.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-43662",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md",
"refsource": "MISC",
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-43662",
"datePublished": "2022-03-30T23:26:03.000Z",
"dateReserved": "2021-11-15T00:00:00.000Z",
"dateUpdated": "2024-08-04T04:03:08.137Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-43661 (GCVE-0-2021-43661)
Vulnerability from nvd – Published: 2022-03-30 23:19 – Updated: 2024-08-04 04:03
VLAI
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/chibataiki/iot-vuls/blob/main/… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:03:08.303Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-30T23:19:19.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-43661",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md",
"refsource": "MISC",
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-43661",
"datePublished": "2022-03-30T23:19:19.000Z",
"dateReserved": "2021-11-15T00:00:00.000Z",
"dateUpdated": "2024-08-04T04:03:08.303Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25008 (GCVE-0-2022-25008)
Vulnerability from nvd – Published: 2022-03-30 22:27 – Updated: 2024-08-03 04:29
VLAI
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/chibataiki/iot-vuls/blob/main/… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:29:01.604Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-30T22:27:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-25008",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md",
"refsource": "MISC",
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-25008",
"datePublished": "2022-03-30T22:27:00.000Z",
"dateReserved": "2022-02-14T00:00:00.000Z",
"dateUpdated": "2024-08-03T04:29:01.604Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-43664 (GCVE-0-2021-43664)
Vulnerability from nvd – Published: 2022-03-30 22:53 – Updated: 2024-08-04 04:03
VLAI
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process forceugpo.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/chibataiki/iot-vuls/blob/main/… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:03:08.641Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process\u0026nbsp;forceugpo."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-30T22:53:59.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-43664",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process\u0026nbsp;forceugpo."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md",
"refsource": "MISC",
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-43664",
"datePublished": "2022-03-30T22:53:59.000Z",
"dateReserved": "2021-11-15T00:00:00.000Z",
"dateUpdated": "2024-08-04T04:03:08.641Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-32449 (GCVE-0-2022-32449)
Vulnerability from cvelistv5 – Published: 2022-07-07 00:00 – Updated: 2024-08-03 07:39
VLAI
Summary
TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:39:51.043Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-01T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
},
{
"url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-32449",
"datePublished": "2022-07-07T00:00:00.000Z",
"dateReserved": "2022-06-05T00:00:00.000Z",
"dateUpdated": "2024-08-03T07:39:51.043Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-43663 (GCVE-0-2021-43663)
Vulnerability from cvelistv5 – Published: 2022-03-30 23:40 – Updated: 2024-08-04 04:03
VLAI
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/chibataiki/iot-vuls/blob/main/… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:03:08.611Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-30T23:40:13.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-43663",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md",
"refsource": "MISC",
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-43663",
"datePublished": "2022-03-30T23:40:13.000Z",
"dateReserved": "2021-11-15T00:00:00.000Z",
"dateUpdated": "2024-08-04T04:03:08.611Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-43662 (GCVE-0-2021-43662)
Vulnerability from cvelistv5 – Published: 2022-03-30 23:26 – Updated: 2024-08-04 04:03
VLAI
Summary
totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/chibataiki/iot-vuls/blob/main/… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:03:08.137Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-30T23:26:03.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-43662",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md",
"refsource": "MISC",
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-43662",
"datePublished": "2022-03-30T23:26:03.000Z",
"dateReserved": "2021-11-15T00:00:00.000Z",
"dateUpdated": "2024-08-04T04:03:08.137Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-43661 (GCVE-0-2021-43661)
Vulnerability from cvelistv5 – Published: 2022-03-30 23:19 – Updated: 2024-08-04 04:03
VLAI
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/chibataiki/iot-vuls/blob/main/… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:03:08.303Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-30T23:19:19.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-43661",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md",
"refsource": "MISC",
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-43661",
"datePublished": "2022-03-30T23:19:19.000Z",
"dateReserved": "2021-11-15T00:00:00.000Z",
"dateUpdated": "2024-08-04T04:03:08.303Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-43664 (GCVE-0-2021-43664)
Vulnerability from cvelistv5 – Published: 2022-03-30 22:53 – Updated: 2024-08-04 04:03
VLAI
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process forceugpo.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/chibataiki/iot-vuls/blob/main/… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:03:08.641Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process\u0026nbsp;forceugpo."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-30T22:53:59.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-43664",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process\u0026nbsp;forceugpo."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md",
"refsource": "MISC",
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-43664",
"datePublished": "2022-03-30T22:53:59.000Z",
"dateReserved": "2021-11-15T00:00:00.000Z",
"dateUpdated": "2024-08-04T04:03:08.641Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25008 (GCVE-0-2022-25008)
Vulnerability from cvelistv5 – Published: 2022-03-30 22:27 – Updated: 2024-08-03 04:29
VLAI
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/chibataiki/iot-vuls/blob/main/… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:29:01.604Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-30T22:27:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-25008",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md",
"refsource": "MISC",
"url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-25008",
"datePublished": "2022-03-30T22:27:00.000Z",
"dateReserved": "2022-02-14T00:00:00.000Z",
"dateUpdated": "2024-08-03T04:29:01.604Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}