Search criteria

48 vulnerabilities found for emc_unity_operating_environment by dell

CVE-2022-22564 (GCVE-0-2022-22564)

Vulnerability from nvd – Published: 2023-02-14 15:34 – Updated: 2025-03-20 14:07
VLAI?
Summary
Dell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.
CWE
  • CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: 0 , < 5.2.0.0.5.173 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.809Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000199050/dsa-2022-021-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-22564",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-20T14:06:54.221204Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-20T14:07:01.410Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.2.0.0.5.173",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-29T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.\u003c/span\u003e\n\n"
            }
          ],
          "value": "Dell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-14T15:41:58.721Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000199050/dsa-2022-021-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-22564",
    "datePublished": "2023-02-14T15:34:09.480Z",
    "dateReserved": "2022-01-04T17:22:21.333Z",
    "dateUpdated": "2025-03-20T14:07:01.410Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36293 (GCVE-0-2021-36293)

Vulnerability from nvd – Published: 2022-04-08 19:50 – Updated: 2024-09-17 01:10
VLAI?
Summary
Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain elevated privileges.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell VNX2 Affected: unspecified , < Version 8.1.21.303 (file) Version 5.33.021.5.303 (block) (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:51.314Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX2",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-03-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain elevated privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-08T19:50:25",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2022-03-31",
          "ID": "CVE-2021-36293",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain elevated privileges."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36293",
    "datePublished": "2022-04-08T19:50:26.071028Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-17T01:10:59.295Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36290 (GCVE-0-2021-36290)

Vulnerability from nvd – Published: 2022-04-08 19:50 – Updated: 2024-09-16 16:53
VLAI?
Summary
Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain privileges.
CWE
  • CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Impacted products
Vendor Product Version
Dell VNX2 Affected: unspecified , < Version 8.1.21.303 (file) Version 5.33.021.5.303 (block) (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:50.680Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX2",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-03-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-08T19:50:24",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2022-03-31",
          "ID": "CVE-2021-36290",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain privileges."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-732: Incorrect Permission Assignment for Critical Resource"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36290",
    "datePublished": "2022-04-08T19:50:24.561131Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-16T16:53:42.840Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36288 (GCVE-0-2021-36288)

Vulnerability from nvd – Published: 2022-04-08 19:50 – Updated: 2024-09-16 17:32
VLAI?
Summary
Dell VNX2 for File version 8.1.21.266 and earlier, contain a path traversal vulnerability which may lead unauthenticated users to read/write restricted files
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
Vendor Product Version
Dell VNX2 Affected: unspecified , < Version 8.1.21.303 (file) Version 5.33.021.5.303 (block) (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:50.660Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX2",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-03-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 for File version 8.1.21.266 and earlier, contain a path traversal vulnerability which may lead unauthenticated users to read/write restricted files"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-08T19:50:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2022-03-31",
          "ID": "CVE-2021-36288",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 for File version 8.1.21.266 and earlier, contain a path traversal vulnerability which may lead unauthenticated users to read/write restricted files"
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 8.6,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36288",
    "datePublished": "2022-04-08T19:50:23.145596Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-16T17:32:57.568Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36287 (GCVE-0-2021-36287)

Vulnerability from nvd – Published: 2022-04-08 19:50 – Updated: 2024-09-16 17:53
VLAI?
Summary
Dell VNX2 for file version 8.1.21.266 and earlier, contain an unauthenticated remote code execution vulnerability which may lead unauthenticated users to execute commands on the system.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell VNX2 Affected: unspecified , < Version 8.1.21.303 (file) Version 5.33.021.5.303 (block) (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:50.695Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX2",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-03-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 for file version 8.1.21.266 and earlier, contain an unauthenticated remote code execution vulnerability which may lead unauthenticated users to execute commands on the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-08T19:50:21",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2022-03-31",
          "ID": "CVE-2021-36287",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 for file version 8.1.21.266 and earlier, contain an unauthenticated remote code execution vulnerability which may lead unauthenticated users to execute commands on the system."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.3,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36287",
    "datePublished": "2022-04-08T19:50:21.612336Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-16T17:53:47.957Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36296 (GCVE-0-2021-36296)

Vulnerability from nvd – Published: 2022-01-25 22:15 – Updated: 2024-09-16 20:38
VLAI?
Summary
Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell VNX Control Station Affected: unspecified , < TBD (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:51.402Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX Control Station",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "TBD",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-25T22:15:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-09-07",
          "ID": "CVE-2021-36296",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX Control Station",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "TBD"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.2,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36296",
    "datePublished": "2022-01-25T22:15:23.857983Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-16T20:38:13.176Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36295 (GCVE-0-2021-36295)

Vulnerability from nvd – Published: 2022-01-25 22:15 – Updated: 2024-09-17 03:53
VLAI?
Summary
Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell VNX Control Station Affected: unspecified , < TBD (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:51.354Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX Control Station",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "TBD",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-25T22:15:22",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-09-07",
          "ID": "CVE-2021-36295",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX Control Station",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "TBD"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.2,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36295",
    "datePublished": "2022-01-25T22:15:22.477767Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-17T03:53:42.290Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36294 (GCVE-0-2021-36294)

Vulnerability from nvd – Published: 2022-01-25 22:15 – Updated: 2024-09-16 16:22
VLAI?
Summary
Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authentication bypass vulnerability. A remote unauthenticated attacker may exploit this vulnerability by forging a cookie to login as any user.
CWE
Assigner
References
Impacted products
Vendor Product Version
Dell VNX Control Station Affected: unspecified , < TBD (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:51.079Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX Control Station",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "TBD",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authentication bypass vulnerability. A remote unauthenticated attacker may exploit this vulnerability by forging a cookie to login as any user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-331",
              "description": "CWE-331: Insufficient Entropy",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-25T22:15:21",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-09-07",
          "ID": "CVE-2021-36294",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX Control Station",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "TBD"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authentication bypass vulnerability. A remote unauthenticated attacker may exploit this vulnerability by forging a cookie to login as any user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-331: Insufficient Entropy"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36294",
    "datePublished": "2022-01-25T22:15:21.100927Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-16T16:22:50.056Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36289 (GCVE-0-2021-36289)

Vulnerability from nvd – Published: 2022-01-25 22:15 – Updated: 2024-09-17 01:50
VLAI?
Summary
Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain a sensitive information disclosure vulnerability. A local malicious user may exploit this vulnerability to read sensitive information and use it.
CWE
  • CWE-532 - Information Exposure Through Log Files
Assigner
References
Impacted products
Vendor Product Version
Dell VNX Control Station Affected: unspecified , < TBD (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:51.380Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX Control Station",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "TBD",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain a sensitive information disclosure vulnerability. A local malicious user may exploit this vulnerability to read sensitive information and use it."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Information Exposure Through Log Files",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-25T22:15:19",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-09-07",
          "ID": "CVE-2021-36289",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX Control Station",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "TBD"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain a sensitive information disclosure vulnerability. A local malicious user may exploit this vulnerability to read sensitive information and use it."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.8,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-532: Information Exposure Through Log Files"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36289",
    "datePublished": "2022-01-25T22:15:19.659371Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-17T01:50:57.134Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43589 (GCVE-0-2021-43589)

Vulnerability from nvd – Published: 2022-01-24 20:10 – Updated: 2024-09-17 00:21
VLAI?
Summary
Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.2.0.5.007 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.414Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.2.0.5.007",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-12-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-24T20:10:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-12-29",
          "ID": "CVE-2021-43589",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.2.0.5.007"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-43589",
    "datePublished": "2022-01-24T20:10:23.923128Z",
    "dateReserved": "2021-11-12T00:00:00",
    "dateUpdated": "2024-09-17T00:21:04.462Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21591 (GCVE-0-2021-21591)

Vulnerability from nvd – Published: 2021-07-12 15:40 – Updated: 2024-09-17 03:48
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.
CWE
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.0.0.5.394 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.465Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189204"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.0.0.5.394",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-12T15:40:18",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189204"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-07-01",
          "ID": "CVE-2021-21591",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.0.0.5.394"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200: Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189204",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189204"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21591",
    "datePublished": "2021-07-12T15:40:18.944714Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-17T03:48:49.687Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21590 (GCVE-0-2021-21590)

Vulnerability from nvd – Published: 2021-07-12 15:40 – Updated: 2024-09-16 20:57
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.
CWE
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.0.0.5.394 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.608Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189204"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.0.0.5.394",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-12T15:40:17",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189204"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-07-01",
          "ID": "CVE-2021-21590",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.0.0.5.394"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200: Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189204",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189204"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21590",
    "datePublished": "2021-07-12T15:40:17.409613Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-16T20:57:44.496Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21589 (GCVE-0-2021-21589)

Vulnerability from nvd – Published: 2021-07-12 15:40 – Updated: 2024-09-17 03:58
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges.
CWE
  • Other
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.0.0.5.394 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.651Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189204"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.0.0.5.394",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Other",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-12T15:40:15",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189204"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-07-01",
          "ID": "CVE-2021-21589",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.0.0.5.394"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 5.7,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189204",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189204"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21589",
    "datePublished": "2021-07-12T15:40:15.913458Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-17T03:58:38.925Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-29490 (GCVE-0-2020-29490)

Vulnerability from nvd – Published: 2021-01-05 21:40 – Updated: 2024-09-16 19:19
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.0.4.0.5.012 contain a Denial of Service vulnerability on NAS Servers with NFS exports. A remote authenticated attacker could potentially exploit this vulnerability and cause Denial of Service (Storage Processor Panic) by sending specially crafted UDP requests.
CWE
  • CWE-400 - Uncontrolled Resource Consumption
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.0.4.0.5.012 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:55:10.389Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000181248"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.0.4.0.5.012",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-12-17T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.0.4.0.5.012 contain a Denial of Service vulnerability on NAS Servers with NFS exports. A remote authenticated attacker could potentially exploit this vulnerability and cause Denial of Service (Storage Processor Panic) by sending specially crafted UDP requests."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-05T21:40:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000181248"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-12-17",
          "ID": "CVE-2020-29490",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.0.4.0.5.012"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.0.4.0.5.012 contain a Denial of Service vulnerability on NAS Servers with NFS exports. A remote authenticated attacker could potentially exploit this vulnerability and cause Denial of Service (Storage Processor Panic) by sending specially crafted UDP requests."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.5,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400: Uncontrolled Resource Consumption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000181248",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000181248"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-29490",
    "datePublished": "2021-01-05T21:40:23.867262Z",
    "dateReserved": "2020-12-03T00:00:00",
    "dateUpdated": "2024-09-16T19:19:39.044Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-29489 (GCVE-0-2020-29489)

Vulnerability from nvd – Published: 2021-01-05 21:40 – Updated: 2024-09-16 22:40
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.0.4.0.5.012 contains a plain-text password storage vulnerability. A user credentials (including the Unisphere admin privilege user) password is stored in a plain text in a system file. A local authenticated attacker with access to the system files may use the exposed password to gain access with the privileges of the compromised user.
CWE
  • CWE-276 - Incorrect Default Permissions
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.0.4.0.5.012 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:55:10.353Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000181248"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.0.4.0.5.012",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-12-17T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.0.4.0.5.012 contains a plain-text password storage vulnerability. A user credentials (including the Unisphere admin privilege user) password is stored in a plain text in a system file. A local authenticated attacker with access to the system files may use the exposed password to gain access with the privileges of the compromised user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276: Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-05T21:40:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000181248"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-12-17",
          "ID": "CVE-2020-29489",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.0.4.0.5.012"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.0.4.0.5.012 contains a plain-text password storage vulnerability. A user credentials (including the Unisphere admin privilege user) password is stored in a plain text in a system file. A local authenticated attacker with access to the system files may use the exposed password to gain access with the privileges of the compromised user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-276: Incorrect Default Permissions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000181248",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000181248"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-29489",
    "datePublished": "2021-01-05T21:40:23.261981Z",
    "dateReserved": "2020-12-03T00:00:00",
    "dateUpdated": "2024-09-16T22:40:50.564Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-26199 (GCVE-0-2020-26199)

Vulnerability from nvd – Published: 2021-01-05 21:40 – Updated: 2024-09-16 20:17
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.0.4.0.5.012 contain a plain-text password storage vulnerability. A user credentials (including the Unisphere admin privilege user) password is stored in a plain text in multiple log files. A local authenticated attacker with access to the log files may use the exposed password to gain access with the privileges of the compromised user.
CWE
  • CWE-532 - Information Exposure Through Log Files
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.0.4.0.5.012 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:49:07.160Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000181248"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.0.4.0.5.012",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-12-17T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.0.4.0.5.012 contain a plain-text password storage vulnerability. A user credentials (including the Unisphere admin privilege user) password is stored in a plain text in multiple log files. A local authenticated attacker with access to the log files may use the exposed password to gain access with the privileges of the compromised user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Information Exposure Through Log Files",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-05T21:40:22",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000181248"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-12-17",
          "ID": "CVE-2020-26199",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.0.4.0.5.012"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.0.4.0.5.012 contain a plain-text password storage vulnerability. A user credentials (including the Unisphere admin privilege user) password is stored in a plain text in multiple log files. A local authenticated attacker with access to the log files may use the exposed password to gain access with the privileges of the compromised user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-532: Information Exposure Through Log Files"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000181248",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000181248"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-26199",
    "datePublished": "2021-01-05T21:40:22.660775Z",
    "dateReserved": "2020-09-30T00:00:00",
    "dateUpdated": "2024-09-16T20:17:54.764Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-22564 (GCVE-0-2022-22564)

Vulnerability from cvelistv5 – Published: 2023-02-14 15:34 – Updated: 2025-03-20 14:07
VLAI?
Summary
Dell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.
CWE
  • CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: 0 , < 5.2.0.0.5.173 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.809Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000199050/dsa-2022-021-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-22564",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-20T14:06:54.221204Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-20T14:07:01.410Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.2.0.0.5.173",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-29T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.\u003c/span\u003e\n\n"
            }
          ],
          "value": "Dell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-14T15:41:58.721Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000199050/dsa-2022-021-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-22564",
    "datePublished": "2023-02-14T15:34:09.480Z",
    "dateReserved": "2022-01-04T17:22:21.333Z",
    "dateUpdated": "2025-03-20T14:07:01.410Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36293 (GCVE-0-2021-36293)

Vulnerability from cvelistv5 – Published: 2022-04-08 19:50 – Updated: 2024-09-17 01:10
VLAI?
Summary
Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain elevated privileges.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell VNX2 Affected: unspecified , < Version 8.1.21.303 (file) Version 5.33.021.5.303 (block) (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:51.314Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX2",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-03-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain elevated privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-08T19:50:25",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2022-03-31",
          "ID": "CVE-2021-36293",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain elevated privileges."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36293",
    "datePublished": "2022-04-08T19:50:26.071028Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-17T01:10:59.295Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36290 (GCVE-0-2021-36290)

Vulnerability from cvelistv5 – Published: 2022-04-08 19:50 – Updated: 2024-09-16 16:53
VLAI?
Summary
Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain privileges.
CWE
  • CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Impacted products
Vendor Product Version
Dell VNX2 Affected: unspecified , < Version 8.1.21.303 (file) Version 5.33.021.5.303 (block) (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:50.680Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX2",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-03-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-08T19:50:24",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2022-03-31",
          "ID": "CVE-2021-36290",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain privileges."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-732: Incorrect Permission Assignment for Critical Resource"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36290",
    "datePublished": "2022-04-08T19:50:24.561131Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-16T16:53:42.840Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36288 (GCVE-0-2021-36288)

Vulnerability from cvelistv5 – Published: 2022-04-08 19:50 – Updated: 2024-09-16 17:32
VLAI?
Summary
Dell VNX2 for File version 8.1.21.266 and earlier, contain a path traversal vulnerability which may lead unauthenticated users to read/write restricted files
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
Vendor Product Version
Dell VNX2 Affected: unspecified , < Version 8.1.21.303 (file) Version 5.33.021.5.303 (block) (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:50.660Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX2",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-03-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 for File version 8.1.21.266 and earlier, contain a path traversal vulnerability which may lead unauthenticated users to read/write restricted files"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-08T19:50:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2022-03-31",
          "ID": "CVE-2021-36288",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 for File version 8.1.21.266 and earlier, contain a path traversal vulnerability which may lead unauthenticated users to read/write restricted files"
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 8.6,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36288",
    "datePublished": "2022-04-08T19:50:23.145596Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-16T17:32:57.568Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36287 (GCVE-0-2021-36287)

Vulnerability from cvelistv5 – Published: 2022-04-08 19:50 – Updated: 2024-09-16 17:53
VLAI?
Summary
Dell VNX2 for file version 8.1.21.266 and earlier, contain an unauthenticated remote code execution vulnerability which may lead unauthenticated users to execute commands on the system.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell VNX2 Affected: unspecified , < Version 8.1.21.303 (file) Version 5.33.021.5.303 (block) (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:50.695Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX2",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-03-31T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 for file version 8.1.21.266 and earlier, contain an unauthenticated remote code execution vulnerability which may lead unauthenticated users to execute commands on the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-08T19:50:21",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2022-03-31",
          "ID": "CVE-2021-36287",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 8.1.21.303 (file) Version 5.33.021.5.303 (block)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 for file version 8.1.21.266 and earlier, contain an unauthenticated remote code execution vulnerability which may lead unauthenticated users to execute commands on the system."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.3,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36287",
    "datePublished": "2022-04-08T19:50:21.612336Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-16T17:53:47.957Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36296 (GCVE-0-2021-36296)

Vulnerability from cvelistv5 – Published: 2022-01-25 22:15 – Updated: 2024-09-16 20:38
VLAI?
Summary
Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell VNX Control Station Affected: unspecified , < TBD (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:51.402Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX Control Station",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "TBD",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-25T22:15:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-09-07",
          "ID": "CVE-2021-36296",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX Control Station",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "TBD"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.2,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36296",
    "datePublished": "2022-01-25T22:15:23.857983Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-16T20:38:13.176Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36295 (GCVE-0-2021-36295)

Vulnerability from cvelistv5 – Published: 2022-01-25 22:15 – Updated: 2024-09-17 03:53
VLAI?
Summary
Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell VNX Control Station Affected: unspecified , < TBD (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:51.354Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX Control Station",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "TBD",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-25T22:15:22",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-09-07",
          "ID": "CVE-2021-36295",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX Control Station",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "TBD"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.2,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36295",
    "datePublished": "2022-01-25T22:15:22.477767Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-17T03:53:42.290Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36294 (GCVE-0-2021-36294)

Vulnerability from cvelistv5 – Published: 2022-01-25 22:15 – Updated: 2024-09-16 16:22
VLAI?
Summary
Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authentication bypass vulnerability. A remote unauthenticated attacker may exploit this vulnerability by forging a cookie to login as any user.
CWE
Assigner
References
Impacted products
Vendor Product Version
Dell VNX Control Station Affected: unspecified , < TBD (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:51.079Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX Control Station",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "TBD",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authentication bypass vulnerability. A remote unauthenticated attacker may exploit this vulnerability by forging a cookie to login as any user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-331",
              "description": "CWE-331: Insufficient Entropy",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-25T22:15:21",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-09-07",
          "ID": "CVE-2021-36294",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX Control Station",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "TBD"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authentication bypass vulnerability. A remote unauthenticated attacker may exploit this vulnerability by forging a cookie to login as any user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-331: Insufficient Entropy"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36294",
    "datePublished": "2022-01-25T22:15:21.100927Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-16T16:22:50.056Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36289 (GCVE-0-2021-36289)

Vulnerability from cvelistv5 – Published: 2022-01-25 22:15 – Updated: 2024-09-17 01:50
VLAI?
Summary
Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain a sensitive information disclosure vulnerability. A local malicious user may exploit this vulnerability to read sensitive information and use it.
CWE
  • CWE-532 - Information Exposure Through Log Files
Assigner
References
Impacted products
Vendor Product Version
Dell VNX Control Station Affected: unspecified , < TBD (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:51.380Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX Control Station",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "TBD",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-09-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain a sensitive information disclosure vulnerability. A local malicious user may exploit this vulnerability to read sensitive information and use it."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Information Exposure Through Log Files",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-25T22:15:19",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-09-07",
          "ID": "CVE-2021-36289",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX Control Station",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "TBD"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain a sensitive information disclosure vulnerability. A local malicious user may exploit this vulnerability to read sensitive information and use it."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.8,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-532: Information Exposure Through Log Files"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000191155/dsa-2021-164-dell-vnx2-control-station-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36289",
    "datePublished": "2022-01-25T22:15:19.659371Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-17T01:50:57.134Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43589 (GCVE-0-2021-43589)

Vulnerability from cvelistv5 – Published: 2022-01-24 20:10 – Updated: 2024-09-17 00:21
VLAI?
Summary
Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.2.0.5.007 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.414Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.2.0.5.007",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-12-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-24T20:10:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-12-29",
          "ID": "CVE-2021-43589",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.2.0.5.007"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-43589",
    "datePublished": "2022-01-24T20:10:23.923128Z",
    "dateReserved": "2021-11-12T00:00:00",
    "dateUpdated": "2024-09-17T00:21:04.462Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21591 (GCVE-0-2021-21591)

Vulnerability from cvelistv5 – Published: 2021-07-12 15:40 – Updated: 2024-09-17 03:48
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.
CWE
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.0.0.5.394 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.465Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189204"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.0.0.5.394",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-12T15:40:18",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189204"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-07-01",
          "ID": "CVE-2021-21591",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.0.0.5.394"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200: Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189204",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189204"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21591",
    "datePublished": "2021-07-12T15:40:18.944714Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-17T03:48:49.687Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21590 (GCVE-0-2021-21590)

Vulnerability from cvelistv5 – Published: 2021-07-12 15:40 – Updated: 2024-09-16 20:57
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.
CWE
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.0.0.5.394 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.608Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189204"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.0.0.5.394",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-12T15:40:17",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189204"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-07-01",
          "ID": "CVE-2021-21590",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.0.0.5.394"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200: Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189204",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189204"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21590",
    "datePublished": "2021-07-12T15:40:17.409613Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-16T20:57:44.496Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21589 (GCVE-0-2021-21589)

Vulnerability from cvelistv5 – Published: 2021-07-12 15:40 – Updated: 2024-09-17 03:58
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges.
CWE
  • Other
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.0.0.5.394 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.651Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189204"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.0.0.5.394",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Other",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-12T15:40:15",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189204"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-07-01",
          "ID": "CVE-2021-21589",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.0.0.5.394"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 5.7,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189204",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189204"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21589",
    "datePublished": "2021-07-12T15:40:15.913458Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-17T03:58:38.925Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-29490 (GCVE-0-2020-29490)

Vulnerability from cvelistv5 – Published: 2021-01-05 21:40 – Updated: 2024-09-16 19:19
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.0.4.0.5.012 contain a Denial of Service vulnerability on NAS Servers with NFS exports. A remote authenticated attacker could potentially exploit this vulnerability and cause Denial of Service (Storage Processor Panic) by sending specially crafted UDP requests.
CWE
  • CWE-400 - Uncontrolled Resource Consumption
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.0.4.0.5.012 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:55:10.389Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000181248"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.0.4.0.5.012",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-12-17T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.0.4.0.5.012 contain a Denial of Service vulnerability on NAS Servers with NFS exports. A remote authenticated attacker could potentially exploit this vulnerability and cause Denial of Service (Storage Processor Panic) by sending specially crafted UDP requests."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-05T21:40:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000181248"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-12-17",
          "ID": "CVE-2020-29490",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.0.4.0.5.012"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.0.4.0.5.012 contain a Denial of Service vulnerability on NAS Servers with NFS exports. A remote authenticated attacker could potentially exploit this vulnerability and cause Denial of Service (Storage Processor Panic) by sending specially crafted UDP requests."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.5,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400: Uncontrolled Resource Consumption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000181248",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000181248"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-29490",
    "datePublished": "2021-01-05T21:40:23.867262Z",
    "dateReserved": "2020-12-03T00:00:00",
    "dateUpdated": "2024-09-16T19:19:39.044Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}