Search

Find a vulnerability

Search criteria

    14 vulnerabilities found for eds-g512e_firmware by moxa

    CVE-2019-19707 (GCVE-0-2019-19707)

    Vulnerability from nvd – Published: 2019-12-11 01:03 – Updated: 2024-08-05 02:25
    VLAI
    Summary
    On Moxa EDS-G508E, EDS-G512E, and EDS-G516E devices (with firmware through 6.0), denial of service can occur via PROFINET DCE-RPC endpoint discovery packets.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:25:12.387Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.moxa.com/en/support/support/security-advisory/eds-g508e-g512e-g516e-series-ethernet-switches-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "On Moxa EDS-G508E, EDS-G512E, and EDS-G516E devices (with firmware through 6.0), denial of service can occur via PROFINET DCE-RPC endpoint discovery packets."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-12-11T01:03:51.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.moxa.com/en/support/support/security-advisory/eds-g508e-g512e-g516e-series-ethernet-switches-vulnerabilities"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-19707",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "On Moxa EDS-G508E, EDS-G512E, and EDS-G516E devices (with firmware through 6.0), denial of service can occur via PROFINET DCE-RPC endpoint discovery packets."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.moxa.com/en/support/support/security-advisory/eds-g508e-g512e-g516e-series-ethernet-switches-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.moxa.com/en/support/support/security-advisory/eds-g508e-g512e-g516e-series-ethernet-switches-vulnerabilities"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-19707",
        "datePublished": "2019-12-11T01:03:51.000Z",
        "dateReserved": "2019-12-11T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:25:12.387Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-13701 (GCVE-0-2017-13701)

    Vulnerability from nvd – Published: 2017-11-23 21:00 – Updated: 2024-08-05 19:05
    VLAI
    Summary
    An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The backup file contains sensitive information in a insecure way. There is no salt for password hashing. Indeed passwords are stored without being ciphered with a timestamped ciphering method.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2017-11-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:05:20.043Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
              },
              {
                "name": "101966",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/101966"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-11-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The backup file contains sensitive information in a insecure way. There is no salt for password hashing. Indeed passwords are stored without being ciphered with a timestamped ciphering method."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-11-28T10:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
            },
            {
              "name": "101966",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/101966"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-13701",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The backup file contains sensitive information in a insecure way. There is no salt for password hashing. Indeed passwords are stored without being ciphered with a timestamped ciphering method."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf",
                  "refsource": "MISC",
                  "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
                },
                {
                  "name": "101966",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/101966"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-13701",
        "datePublished": "2017-11-23T21:00:00.000Z",
        "dateReserved": "2017-08-25T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:05:20.043Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-13699 (GCVE-0-2017-13699)

    Vulnerability from nvd – Published: 2017-11-23 21:00 – Updated: 2024-08-05 19:05
    VLAI
    Summary
    An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The password encryption method can be retrieved from the firmware. This encryption method is based on a chall value that is sent in cleartext as a POST parameter. An attacker could reverse the password encryption algorithm to retrieve it.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2017-11-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:05:20.012Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
              },
              {
                "name": "106047",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/106047"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-11-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The password encryption method can be retrieved from the firmware. This encryption method is based on a chall value that is sent in cleartext as a POST parameter. An attacker could reverse the password encryption algorithm to retrieve it."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-11-30T10:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
            },
            {
              "name": "106047",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/106047"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-13699",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The password encryption method can be retrieved from the firmware. This encryption method is based on a chall value that is sent in cleartext as a POST parameter. An attacker could reverse the password encryption algorithm to retrieve it."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf",
                  "refsource": "MISC",
                  "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
                },
                {
                  "name": "106047",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/106047"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-13699",
        "datePublished": "2017-11-23T21:00:00.000Z",
        "dateReserved": "2017-08-25T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:05:20.012Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-13698 (GCVE-0-2017-13698)

    Vulnerability from nvd – Published: 2017-11-23 21:00 – Updated: 2024-08-05 19:05
    VLAI
    Summary
    An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2017-11-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:05:19.938Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-11-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-11-23T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-13698",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf",
                  "refsource": "MISC",
                  "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-13698",
        "datePublished": "2017-11-23T21:00:00.000Z",
        "dateReserved": "2017-08-25T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:05:19.938Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-13703 (GCVE-0-2017-13703)

    Vulnerability from nvd – Published: 2017-11-17 18:00 – Updated: 2024-08-05 19:05
    VLAI
    Summary
    An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. A denial of service may occur.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2017-11-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:05:19.908Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-11-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. A denial of service may occur."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-11-17T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-13703",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. A denial of service may occur."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/",
                  "refsource": "MISC",
                  "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-13703",
        "datePublished": "2017-11-17T18:00:00.000Z",
        "dateReserved": "2017-08-25T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:05:19.908Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-13702 (GCVE-0-2017-13702)

    Vulnerability from nvd – Published: 2017-11-17 18:00 – Updated: 2024-08-05 19:05
    VLAI
    Summary
    An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. Cookies can be stolen, manipulated, and reused.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2017-11-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:05:20.022Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-11-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. Cookies can be stolen, manipulated, and reused."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-11-17T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-13702",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. Cookies can be stolen, manipulated, and reused."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/",
                  "refsource": "MISC",
                  "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-13702",
        "datePublished": "2017-11-17T18:00:00.000Z",
        "dateReserved": "2017-08-25T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:05:20.022Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-13700 (GCVE-0-2017-13700)

    Vulnerability from nvd – Published: 2017-11-17 18:00 – Updated: 2024-08-05 19:05
    VLAI
    Summary
    An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. There is XSS in the administration interface.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2017-11-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:05:19.874Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-11-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. There is XSS in the administration interface."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-11-17T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-13700",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. There is XSS in the administration interface."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/",
                  "refsource": "MISC",
                  "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-13700",
        "datePublished": "2017-11-17T18:00:00.000Z",
        "dateReserved": "2017-08-25T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:05:19.874Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-19707 (GCVE-0-2019-19707)

    Vulnerability from cvelistv5 – Published: 2019-12-11 01:03 – Updated: 2024-08-05 02:25
    VLAI
    Summary
    On Moxa EDS-G508E, EDS-G512E, and EDS-G516E devices (with firmware through 6.0), denial of service can occur via PROFINET DCE-RPC endpoint discovery packets.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:25:12.387Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.moxa.com/en/support/support/security-advisory/eds-g508e-g512e-g516e-series-ethernet-switches-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "On Moxa EDS-G508E, EDS-G512E, and EDS-G516E devices (with firmware through 6.0), denial of service can occur via PROFINET DCE-RPC endpoint discovery packets."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-12-11T01:03:51.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.moxa.com/en/support/support/security-advisory/eds-g508e-g512e-g516e-series-ethernet-switches-vulnerabilities"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-19707",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "On Moxa EDS-G508E, EDS-G512E, and EDS-G516E devices (with firmware through 6.0), denial of service can occur via PROFINET DCE-RPC endpoint discovery packets."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.moxa.com/en/support/support/security-advisory/eds-g508e-g512e-g516e-series-ethernet-switches-vulnerabilities",
                  "refsource": "MISC",
                  "url": "https://www.moxa.com/en/support/support/security-advisory/eds-g508e-g512e-g516e-series-ethernet-switches-vulnerabilities"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-19707",
        "datePublished": "2019-12-11T01:03:51.000Z",
        "dateReserved": "2019-12-11T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:25:12.387Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-13698 (GCVE-0-2017-13698)

    Vulnerability from cvelistv5 – Published: 2017-11-23 21:00 – Updated: 2024-08-05 19:05
    VLAI
    Summary
    An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2017-11-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:05:19.938Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-11-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-11-23T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-13698",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf",
                  "refsource": "MISC",
                  "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-13698",
        "datePublished": "2017-11-23T21:00:00.000Z",
        "dateReserved": "2017-08-25T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:05:19.938Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-13699 (GCVE-0-2017-13699)

    Vulnerability from cvelistv5 – Published: 2017-11-23 21:00 – Updated: 2024-08-05 19:05
    VLAI
    Summary
    An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The password encryption method can be retrieved from the firmware. This encryption method is based on a chall value that is sent in cleartext as a POST parameter. An attacker could reverse the password encryption algorithm to retrieve it.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2017-11-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:05:20.012Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
              },
              {
                "name": "106047",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/106047"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-11-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The password encryption method can be retrieved from the firmware. This encryption method is based on a chall value that is sent in cleartext as a POST parameter. An attacker could reverse the password encryption algorithm to retrieve it."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-11-30T10:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
            },
            {
              "name": "106047",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/106047"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-13699",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The password encryption method can be retrieved from the firmware. This encryption method is based on a chall value that is sent in cleartext as a POST parameter. An attacker could reverse the password encryption algorithm to retrieve it."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf",
                  "refsource": "MISC",
                  "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
                },
                {
                  "name": "106047",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/106047"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-13699",
        "datePublished": "2017-11-23T21:00:00.000Z",
        "dateReserved": "2017-08-25T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:05:20.012Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-13701 (GCVE-0-2017-13701)

    Vulnerability from cvelistv5 – Published: 2017-11-23 21:00 – Updated: 2024-08-05 19:05
    VLAI
    Summary
    An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The backup file contains sensitive information in a insecure way. There is no salt for password hashing. Indeed passwords are stored without being ciphered with a timestamped ciphering method.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2017-11-23 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:05:20.043Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
              },
              {
                "name": "101966",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/101966"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-11-23T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The backup file contains sensitive information in a insecure way. There is no salt for password hashing. Indeed passwords are stored without being ciphered with a timestamped ciphering method."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-11-28T10:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
            },
            {
              "name": "101966",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/101966"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-13701",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The backup file contains sensitive information in a insecure way. There is no salt for password hashing. Indeed passwords are stored without being ciphered with a timestamped ciphering method."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf",
                  "refsource": "MISC",
                  "url": "https://www.sentryo.net/wp-content/uploads/2017/11/Switch-Moxa-Analysis.pdf"
                },
                {
                  "name": "101966",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/101966"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-13701",
        "datePublished": "2017-11-23T21:00:00.000Z",
        "dateReserved": "2017-08-25T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:05:20.043Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-13702 (GCVE-0-2017-13702)

    Vulnerability from cvelistv5 – Published: 2017-11-17 18:00 – Updated: 2024-08-05 19:05
    VLAI
    Summary
    An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. Cookies can be stolen, manipulated, and reused.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2017-11-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:05:20.022Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-11-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. Cookies can be stolen, manipulated, and reused."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-11-17T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-13702",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. Cookies can be stolen, manipulated, and reused."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/",
                  "refsource": "MISC",
                  "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-13702",
        "datePublished": "2017-11-17T18:00:00.000Z",
        "dateReserved": "2017-08-25T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:05:20.022Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-13703 (GCVE-0-2017-13703)

    Vulnerability from cvelistv5 – Published: 2017-11-17 18:00 – Updated: 2024-08-05 19:05
    VLAI
    Summary
    An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. A denial of service may occur.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2017-11-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:05:19.908Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-11-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. A denial of service may occur."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-11-17T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-13703",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. A denial of service may occur."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/",
                  "refsource": "MISC",
                  "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-13703",
        "datePublished": "2017-11-17T18:00:00.000Z",
        "dateReserved": "2017-08-25T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:05:19.908Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-13700 (GCVE-0-2017-13700)

    Vulnerability from cvelistv5 – Published: 2017-11-17 18:00 – Updated: 2024-08-05 19:05
    VLAI
    Summary
    An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. There is XSS in the administration interface.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2017-11-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T19:05:19.874Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2017-11-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. There is XSS in the administration interface."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-11-17T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-13700",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. There is XSS in the administration interface."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/",
                  "refsource": "MISC",
                  "url": "https://www.sentryo.net/fr/sentryo-analyse-switch-industriel/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-13700",
        "datePublished": "2017-11-17T18:00:00.000Z",
        "dateReserved": "2017-08-25T00:00:00.000Z",
        "dateUpdated": "2024-08-05T19:05:19.874Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }