Search

Find a vulnerability

Search criteria

    10 vulnerabilities found for edgeswitch_firmware by ui

    CVE-2020-8233 (GCVE-0-2020-8233)

    Vulnerability from nvd – Published: 2020-08-17 15:41 – Updated: 2024-08-04 09:56
    VLAI
    Summary
    A command injection vulnerability exists in EdgeSwitch firmware <v1.9.0 that allowed an authenticated read-only user to execute arbitrary shell commands over the HTTP interface, allowing them to escalate privileges.
    Severity
    No CVSS data available.
    CWE
    • CWE-77 - Command Injection - Generic (CWE-77)
    Assigner
    Impacted products
    Vendor Product Version
    n/a EdgeSwitch firmware v1.9.0 and prior Affected: Fixed version EdgeSwitch firmware v1.9.1
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:56:27.573Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ui.com/download/edgemax"
              },
              {
                "name": "openSUSE-SU-2020:1652",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_SUSE",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-10/msg00019.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EdgeSwitch firmware v1.9.0 and prior",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed version EdgeSwitch firmware v1.9.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A command injection vulnerability exists in EdgeSwitch firmware \u003cv1.9.0 that allowed an authenticated read-only user to execute arbitrary shell commands over the HTTP interface, allowing them to escalate privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection - Generic (CWE-77)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-10T23:06:22.000Z",
            "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
            "shortName": "hackerone"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ui.com/download/edgemax"
            },
            {
              "name": "openSUSE-SU-2020:1652",
              "tags": [
                "vendor-advisory",
                "x_refsource_SUSE"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-10/msg00019.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "support@hackerone.com",
              "ID": "CVE-2020-8233",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EdgeSwitch firmware v1.9.0 and prior",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Fixed version EdgeSwitch firmware v1.9.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A command injection vulnerability exists in EdgeSwitch firmware \u003cv1.9.0 that allowed an authenticated read-only user to execute arbitrary shell commands over the HTTP interface, allowing them to escalate privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Command Injection - Generic (CWE-77)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821",
                  "refsource": "MISC",
                  "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
                },
                {
                  "name": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c",
                  "refsource": "MISC",
                  "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
                },
                {
                  "name": "https://www.ui.com/download/edgemax",
                  "refsource": "MISC",
                  "url": "https://www.ui.com/download/edgemax"
                },
                {
                  "name": "openSUSE-SU-2020:1652",
                  "refsource": "SUSE",
                  "url": "http://lists.opensuse.org/opensuse-security-announce/2020-10/msg00019.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "assignerShortName": "hackerone",
        "cveId": "CVE-2020-8233",
        "datePublished": "2020-08-17T15:41:19.000Z",
        "dateReserved": "2020-01-28T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:56:27.573Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-8232 (GCVE-0-2020-8232)

    Vulnerability from nvd – Published: 2020-08-17 15:40 – Updated: 2024-08-04 09:56
    VLAI
    Summary
    An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages.
    Severity
    No CVSS data available.
    CWE
    • CWE-200 - Information Disclosure (CWE-200)
    Assigner
    Impacted products
    Vendor Product Version
    n/a EdgeSwitch firmware v1.9.0 and prior Affected: Fixed in EdgeMax EdgeSwitch firmware v1.9.1
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:56:27.604Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ui.com/download/edgemax"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EdgeSwitch firmware v1.9.0 and prior",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in EdgeMax EdgeSwitch firmware v1.9.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "Information Disclosure (CWE-200)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-08-17T15:40:59.000Z",
            "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
            "shortName": "hackerone"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ui.com/download/edgemax"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "support@hackerone.com",
              "ID": "CVE-2020-8232",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EdgeSwitch firmware v1.9.0 and prior",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Fixed in EdgeMax EdgeSwitch firmware v1.9.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Information Disclosure (CWE-200)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821",
                  "refsource": "MISC",
                  "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
                },
                {
                  "name": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c",
                  "refsource": "MISC",
                  "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
                },
                {
                  "name": "https://www.ui.com/download/edgemax",
                  "refsource": "MISC",
                  "url": "https://www.ui.com/download/edgemax"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "assignerShortName": "hackerone",
        "cveId": "CVE-2020-8232",
        "datePublished": "2020-08-17T15:40:59.000Z",
        "dateReserved": "2020-01-28T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:56:27.604Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-5446 (GCVE-0-2019-5446)

    Vulnerability from nvd – Published: 2019-07-10 19:47 – Updated: 2024-08-04 19:54
    VLAI
    Summary
    Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root.
    Severity
    No CVSS data available.
    CWE
    • CWE-77 - Command Injection - Generic (CWE-77)
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EdgeMAX Affected: 1.8.1
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T19:54:53.484Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EdgeMAX",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.8.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection - Generic (CWE-77)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-10T19:47:07.000Z",
            "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
            "shortName": "hackerone"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "support@hackerone.com",
              "ID": "CVE-2019-5446",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EdgeMAX",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.8.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Command Injection - Generic (CWE-77)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7",
                  "refsource": "MISC",
                  "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "assignerShortName": "hackerone",
        "cveId": "CVE-2019-5446",
        "datePublished": "2019-07-10T19:47:07.000Z",
        "dateReserved": "2019-01-04T00:00:00.000Z",
        "dateUpdated": "2024-08-04T19:54:53.484Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-5445 (GCVE-0-2019-5445)

    Vulnerability from nvd – Published: 2019-07-10 19:45 – Updated: 2024-08-04 19:54
    VLAI
    Summary
    DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands.
    Severity
    No CVSS data available.
    CWE
    • CWE-400 - Denial of Service (CWE-400)
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EdgeMAX Affected: 1.8.1
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T19:54:53.583Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EdgeMAX",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.8.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "Denial of Service (CWE-400)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-10T19:45:09.000Z",
            "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
            "shortName": "hackerone"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "support@hackerone.com",
              "ID": "CVE-2019-5445",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EdgeMAX",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.8.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Denial of Service (CWE-400)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7",
                  "refsource": "MISC",
                  "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "assignerShortName": "hackerone",
        "cveId": "CVE-2019-5445",
        "datePublished": "2019-07-10T19:45:09.000Z",
        "dateReserved": "2019-01-04T00:00:00.000Z",
        "dateUpdated": "2024-08-04T19:54:53.583Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-12590 (GCVE-0-2018-12590)

    Vulnerability from nvd – Published: 2018-06-20 12:00 – Updated: 2024-09-16 22:55
    VLAI
    Summary
    Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an externally controlled format-string vulnerability due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    https://hackerone.com/reports/311884 x_refsource_MISC
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:38:06.333Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://hackerone.com/reports/311884"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an externally controlled format-string vulnerability due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-06-20T12:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://hackerone.com/reports/311884"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-12590",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an externally controlled format-string vulnerability due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://hackerone.com/reports/311884",
                  "refsource": "MISC",
                  "url": "https://hackerone.com/reports/311884"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-12590",
        "datePublished": "2018-06-20T12:00:00.000Z",
        "dateReserved": "2018-06-20T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:55:54.622Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-8233 (GCVE-0-2020-8233)

    Vulnerability from cvelistv5 – Published: 2020-08-17 15:41 – Updated: 2024-08-04 09:56
    VLAI
    Summary
    A command injection vulnerability exists in EdgeSwitch firmware <v1.9.0 that allowed an authenticated read-only user to execute arbitrary shell commands over the HTTP interface, allowing them to escalate privileges.
    Severity
    No CVSS data available.
    CWE
    • CWE-77 - Command Injection - Generic (CWE-77)
    Assigner
    Impacted products
    Vendor Product Version
    n/a EdgeSwitch firmware v1.9.0 and prior Affected: Fixed version EdgeSwitch firmware v1.9.1
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:56:27.573Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ui.com/download/edgemax"
              },
              {
                "name": "openSUSE-SU-2020:1652",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_SUSE",
                  "x_transferred"
                ],
                "url": "http://lists.opensuse.org/opensuse-security-announce/2020-10/msg00019.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EdgeSwitch firmware v1.9.0 and prior",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed version EdgeSwitch firmware v1.9.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A command injection vulnerability exists in EdgeSwitch firmware \u003cv1.9.0 that allowed an authenticated read-only user to execute arbitrary shell commands over the HTTP interface, allowing them to escalate privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection - Generic (CWE-77)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-10-10T23:06:22.000Z",
            "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
            "shortName": "hackerone"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ui.com/download/edgemax"
            },
            {
              "name": "openSUSE-SU-2020:1652",
              "tags": [
                "vendor-advisory",
                "x_refsource_SUSE"
              ],
              "url": "http://lists.opensuse.org/opensuse-security-announce/2020-10/msg00019.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "support@hackerone.com",
              "ID": "CVE-2020-8233",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EdgeSwitch firmware v1.9.0 and prior",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Fixed version EdgeSwitch firmware v1.9.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A command injection vulnerability exists in EdgeSwitch firmware \u003cv1.9.0 that allowed an authenticated read-only user to execute arbitrary shell commands over the HTTP interface, allowing them to escalate privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Command Injection - Generic (CWE-77)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821",
                  "refsource": "MISC",
                  "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
                },
                {
                  "name": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c",
                  "refsource": "MISC",
                  "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
                },
                {
                  "name": "https://www.ui.com/download/edgemax",
                  "refsource": "MISC",
                  "url": "https://www.ui.com/download/edgemax"
                },
                {
                  "name": "openSUSE-SU-2020:1652",
                  "refsource": "SUSE",
                  "url": "http://lists.opensuse.org/opensuse-security-announce/2020-10/msg00019.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "assignerShortName": "hackerone",
        "cveId": "CVE-2020-8233",
        "datePublished": "2020-08-17T15:41:19.000Z",
        "dateReserved": "2020-01-28T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:56:27.573Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-8232 (GCVE-0-2020-8232)

    Vulnerability from cvelistv5 – Published: 2020-08-17 15:40 – Updated: 2024-08-04 09:56
    VLAI
    Summary
    An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages.
    Severity
    No CVSS data available.
    CWE
    • CWE-200 - Information Disclosure (CWE-200)
    Assigner
    Impacted products
    Vendor Product Version
    n/a EdgeSwitch firmware v1.9.0 and prior Affected: Fixed in EdgeMax EdgeSwitch firmware v1.9.1
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:56:27.604Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ui.com/download/edgemax"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EdgeSwitch firmware v1.9.0 and prior",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in EdgeMax EdgeSwitch firmware v1.9.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "Information Disclosure (CWE-200)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-08-17T15:40:59.000Z",
            "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
            "shortName": "hackerone"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ui.com/download/edgemax"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "support@hackerone.com",
              "ID": "CVE-2020-8232",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EdgeSwitch firmware v1.9.0 and prior",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Fixed in EdgeMax EdgeSwitch firmware v1.9.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Information Disclosure (CWE-200)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821",
                  "refsource": "MISC",
                  "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
                },
                {
                  "name": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c",
                  "refsource": "MISC",
                  "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
                },
                {
                  "name": "https://www.ui.com/download/edgemax",
                  "refsource": "MISC",
                  "url": "https://www.ui.com/download/edgemax"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "assignerShortName": "hackerone",
        "cveId": "CVE-2020-8232",
        "datePublished": "2020-08-17T15:40:59.000Z",
        "dateReserved": "2020-01-28T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:56:27.604Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-5446 (GCVE-0-2019-5446)

    Vulnerability from cvelistv5 – Published: 2019-07-10 19:47 – Updated: 2024-08-04 19:54
    VLAI
    Summary
    Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root.
    Severity
    No CVSS data available.
    CWE
    • CWE-77 - Command Injection - Generic (CWE-77)
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EdgeMAX Affected: 1.8.1
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T19:54:53.484Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EdgeMAX",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.8.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection - Generic (CWE-77)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-10T19:47:07.000Z",
            "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
            "shortName": "hackerone"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "support@hackerone.com",
              "ID": "CVE-2019-5446",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EdgeMAX",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.8.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Command Injection - Generic (CWE-77)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7",
                  "refsource": "MISC",
                  "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "assignerShortName": "hackerone",
        "cveId": "CVE-2019-5446",
        "datePublished": "2019-07-10T19:47:07.000Z",
        "dateReserved": "2019-01-04T00:00:00.000Z",
        "dateUpdated": "2024-08-04T19:54:53.484Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-5445 (GCVE-0-2019-5445)

    Vulnerability from cvelistv5 – Published: 2019-07-10 19:45 – Updated: 2024-08-04 19:54
    VLAI
    Summary
    DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands.
    Severity
    No CVSS data available.
    CWE
    • CWE-400 - Denial of Service (CWE-400)
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EdgeMAX Affected: 1.8.1
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T19:54:53.583Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EdgeMAX",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.8.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "Denial of Service (CWE-400)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-10T19:45:09.000Z",
            "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
            "shortName": "hackerone"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "support@hackerone.com",
              "ID": "CVE-2019-5445",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EdgeMAX",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.8.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Denial of Service (CWE-400)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7",
                  "refsource": "MISC",
                  "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "assignerShortName": "hackerone",
        "cveId": "CVE-2019-5445",
        "datePublished": "2019-07-10T19:45:09.000Z",
        "dateReserved": "2019-01-04T00:00:00.000Z",
        "dateUpdated": "2024-08-04T19:54:53.583Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-12590 (GCVE-0-2018-12590)

    Vulnerability from cvelistv5 – Published: 2018-06-20 12:00 – Updated: 2024-09-16 22:55
    VLAI
    Summary
    Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an externally controlled format-string vulnerability due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    https://hackerone.com/reports/311884 x_refsource_MISC
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:38:06.333Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://hackerone.com/reports/311884"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an externally controlled format-string vulnerability due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-06-20T12:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://hackerone.com/reports/311884"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-12590",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an externally controlled format-string vulnerability due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://hackerone.com/reports/311884",
                  "refsource": "MISC",
                  "url": "https://hackerone.com/reports/311884"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-12590",
        "datePublished": "2018-06-20T12:00:00.000Z",
        "dateReserved": "2018-06-20T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:55:54.622Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }