    CVE-2023-32471 (GCVE-0-2023-32471)

    Vulnerability from nvd – Published: 2024-07-24 07:08 – Updated: 2024-08-02 15:18
    VLAI
    Summary
    Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds read vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability to read contents of stack memory and use this information for further exploits.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Edge Gateway 5200 Affected: N/A , < v1.05.10 (semver)
    Create a notification for this product.
    Dell Dell Edge Gateway 3200 Affected: N/A , < v1.03.10 (semver)
    Create a notification for this product.
    dell dell_edge_gateway_5200 Affected: 0 , < v1.05.10 (semver)
        cpe:2.3:h:dell:dell_edge_gateway_5200:*:*:*:*:*:*:*:*
    Create a notification for this product.
    dell dell_edge_gateway_3200 Affected: 0 , < v1.03.10 (semver)
        cpe:2.3:h:dell:dell_edge_gateway_3200:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-06-14 06:30
    Credits
    Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:dell:dell_edge_gateway_5200:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "dell_edge_gateway_5200",
                "vendor": "dell",
                "versions": [
                  {
                    "lessThan": "v1.05.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:dell:dell_edge_gateway_3200:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "dell_edge_gateway_3200",
                "vendor": "dell",
                "versions": [
                  {
                    "lessThan": "v1.03.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32471",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-24T18:41:40.675410Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-24T19:02:33.270Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.608Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Edge Gateway 5200",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "v1.05.10",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Dell Edge Gateway 3200",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "v1.03.10",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues."
            }
          ],
          "datePublic": "2023-06-14T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds read vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability to read contents of stack memory and use this information for further exploits."
                }
              ],
              "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds read vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability to read contents of stack memory and use this information for further exploits."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-24T07:08:51.832Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32471",
        "datePublished": "2024-07-24T07:08:51.832Z",
        "dateReserved": "2023-05-09T06:07:41.364Z",
        "dateUpdated": "2024-08-02T15:18:37.608Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32472 (GCVE-0-2023-32472)

    Vulnerability from nvd – Published: 2024-07-10 02:32 – Updated: 2024-09-26 11:57
    VLAI
    Summary
    Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some code in System Management Mode, leading to arbitrary code execution or escalation of privilege.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerSwitch Z9664F-ON BIOS Affected: N/A , < v1.05.10 (semver)
    Create a notification for this product.
    dell powerswitch_z9664f_on-bios Affected: 0 , < v1.05.10 (semver)
        cpe:2.3:a:dell:powerswitch_z9664f_on-bios:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-06-14 06:30
    Credits
    Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:dell:powerswitch_z9664f_on-bios:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "powerswitch_z9664f_on-bios",
                "vendor": "dell",
                "versions": [
                  {
                    "lessThan": "v1.05.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32472",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-23T18:34:02.518285Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-23T18:43:41.144Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.025Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerSwitch Z9664F-ON BIOS",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "v1.05.10",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues"
            }
          ],
          "datePublic": "2023-06-14T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some code in System Management Mode, leading to arbitrary code execution or escalation of privilege."
                }
              ],
              "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some code in System Management Mode, leading to arbitrary code execution or escalation of privilege."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 5.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-26T11:57:38.816Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32472",
        "datePublished": "2024-07-10T02:32:00.277Z",
        "dateReserved": "2023-05-09T06:07:41.364Z",
        "dateUpdated": "2024-09-26T11:57:38.816Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32467 (GCVE-0-2023-32467)

    Vulnerability from nvd – Published: 2024-07-10 02:39 – Updated: 2024-08-02 15:18
    VLAI
    Summary
    Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-665 - Improper Initialization
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerSwitch Z9664F-ON BIOS Affected: N/A , < v1.05.10 (semver)
    Create a notification for this product.
    Date Public
    2023-06-14 06:30
    Credits
    Dell Technologies would also like to thank yngweijw (Jiawei Yin) for reporting this issue Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32467",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-31T15:53:25.320608Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-31T15:53:33.059Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.188Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerSwitch Z9664F-ON BIOS",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "v1.05.10",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell Technologies would also like to thank yngweijw (Jiawei Yin) for reporting this issue"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues"
            }
          ],
          "datePublic": "2023-06-14T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege."
                }
              ],
              "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 5.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-665",
                  "description": "CWE-665: Improper Initialization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-10T02:39:47.352Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32467",
        "datePublished": "2024-07-10T02:39:47.352Z",
        "dateReserved": "2023-05-09T06:07:41.363Z",
        "dateUpdated": "2024-08-02T15:18:37.188Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34383 (GCVE-0-2022-34383)

    Vulnerability from nvd – Published: 2022-08-31 20:05 – Updated: 2024-09-16 23:35
    VLAI
    Summary
    Dell Edge Gateway 5200 (EGW) versions before 1.03.10 contain an operating system command injection vulnerability. A local malicious user may potentially exploit this vulnerability by using an SMI to bypass PMC mitigation and gain arbitrary code execution during SMM.
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Edge Gateway 5200 Affected: unspecified , < 1.03.10 (custom)
    Create a notification for this product.
    Date Public
    2022-08-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:07:16.231Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000202711"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Edge Gateway 5200",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "1.03.10",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-08-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Dell Edge Gateway 5200 (EGW) versions before 1.03.10 contain an operating system command injection vulnerability. A local malicious user may potentially exploit this vulnerability by using an SMI to bypass PMC mitigation and gain arbitrary code execution during SMM."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-08-31T20:05:16.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000202711"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2022-08-24",
              "ID": "CVE-2022-34383",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Edge Gateway 5200",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "1.03.10"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Dell Edge Gateway 5200 (EGW) versions before 1.03.10 contain an operating system command injection vulnerability. A local malicious user may potentially exploit this vulnerability by using an SMI to bypass PMC mitigation and gain arbitrary code execution during SMM."
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 8.1,
                "baseSeverity": "High",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/kbdoc/en-us/000202711",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/kbdoc/en-us/000202711"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34383",
        "datePublished": "2022-08-31T20:05:16.529Z",
        "dateReserved": "2022-06-23T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:35:34.303Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32471 (GCVE-0-2023-32471)

    Vulnerability from cvelistv5 – Published: 2024-07-24 07:08 – Updated: 2024-08-02 15:18
    VLAI
    Summary
    Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds read vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability to read contents of stack memory and use this information for further exploits.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Edge Gateway 5200 Affected: N/A , < v1.05.10 (semver)
    Create a notification for this product.
    Dell Dell Edge Gateway 3200 Affected: N/A , < v1.03.10 (semver)
    Create a notification for this product.
    dell dell_edge_gateway_5200 Affected: 0 , < v1.05.10 (semver)
        cpe:2.3:h:dell:dell_edge_gateway_5200:*:*:*:*:*:*:*:*
    Create a notification for this product.
    dell dell_edge_gateway_3200 Affected: 0 , < v1.03.10 (semver)
        cpe:2.3:h:dell:dell_edge_gateway_3200:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-06-14 06:30
    Credits
    Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:dell:dell_edge_gateway_5200:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "dell_edge_gateway_5200",
                "vendor": "dell",
                "versions": [
                  {
                    "lessThan": "v1.05.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:dell:dell_edge_gateway_3200:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "dell_edge_gateway_3200",
                "vendor": "dell",
                "versions": [
                  {
                    "lessThan": "v1.03.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32471",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-24T18:41:40.675410Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-24T19:02:33.270Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.608Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Edge Gateway 5200",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "v1.05.10",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Dell Edge Gateway 3200",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "v1.03.10",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues."
            }
          ],
          "datePublic": "2023-06-14T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds read vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability to read contents of stack memory and use this information for further exploits."
                }
              ],
              "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds read vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability to read contents of stack memory and use this information for further exploits."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-24T07:08:51.832Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32471",
        "datePublished": "2024-07-24T07:08:51.832Z",
        "dateReserved": "2023-05-09T06:07:41.364Z",
        "dateUpdated": "2024-08-02T15:18:37.608Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32467 (GCVE-0-2023-32467)

    Vulnerability from cvelistv5 – Published: 2024-07-10 02:39 – Updated: 2024-08-02 15:18
    VLAI
    Summary
    Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-665 - Improper Initialization
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerSwitch Z9664F-ON BIOS Affected: N/A , < v1.05.10 (semver)
    Create a notification for this product.
    Date Public
    2023-06-14 06:30
    Credits
    Dell Technologies would also like to thank yngweijw (Jiawei Yin) for reporting this issue Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32467",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-31T15:53:25.320608Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-31T15:53:33.059Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.188Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerSwitch Z9664F-ON BIOS",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "v1.05.10",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell Technologies would also like to thank yngweijw (Jiawei Yin) for reporting this issue"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues"
            }
          ],
          "datePublic": "2023-06-14T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege."
                }
              ],
              "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 5.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-665",
                  "description": "CWE-665: Improper Initialization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-10T02:39:47.352Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32467",
        "datePublished": "2024-07-10T02:39:47.352Z",
        "dateReserved": "2023-05-09T06:07:41.363Z",
        "dateUpdated": "2024-08-02T15:18:37.188Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32472 (GCVE-0-2023-32472)

    Vulnerability from cvelistv5 – Published: 2024-07-10 02:32 – Updated: 2024-09-26 11:57
    VLAI
    Summary
    Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some code in System Management Mode, leading to arbitrary code execution or escalation of privilege.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerSwitch Z9664F-ON BIOS Affected: N/A , < v1.05.10 (semver)
    Create a notification for this product.
    dell powerswitch_z9664f_on-bios Affected: 0 , < v1.05.10 (semver)
        cpe:2.3:a:dell:powerswitch_z9664f_on-bios:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-06-14 06:30
    Credits
    Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:dell:powerswitch_z9664f_on-bios:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "powerswitch_z9664f_on-bios",
                "vendor": "dell",
                "versions": [
                  {
                    "lessThan": "v1.05.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32472",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-23T18:34:02.518285Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-23T18:43:41.144Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.025Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerSwitch Z9664F-ON BIOS",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "v1.05.10",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues"
            }
          ],
          "datePublic": "2023-06-14T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some code in System Management Mode, leading to arbitrary code execution or escalation of privilege."
                }
              ],
              "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some code in System Management Mode, leading to arbitrary code execution or escalation of privilege."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 5.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-26T11:57:38.816Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32472",
        "datePublished": "2024-07-10T02:32:00.277Z",
        "dateReserved": "2023-05-09T06:07:41.364Z",
        "dateUpdated": "2024-09-26T11:57:38.816Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34383 (GCVE-0-2022-34383)

    Vulnerability from cvelistv5 – Published: 2022-08-31 20:05 – Updated: 2024-09-16 23:35
    VLAI
    Summary
    Dell Edge Gateway 5200 (EGW) versions before 1.03.10 contain an operating system command injection vulnerability. A local malicious user may potentially exploit this vulnerability by using an SMI to bypass PMC mitigation and gain arbitrary code execution during SMM.
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Edge Gateway 5200 Affected: unspecified , < 1.03.10 (custom)
    Create a notification for this product.
    Date Public
    2022-08-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T09:07:16.231Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000202711"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Edge Gateway 5200",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "1.03.10",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-08-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Dell Edge Gateway 5200 (EGW) versions before 1.03.10 contain an operating system command injection vulnerability. A local malicious user may potentially exploit this vulnerability by using an SMI to bypass PMC mitigation and gain arbitrary code execution during SMM."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-08-31T20:05:16.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000202711"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2022-08-24",
              "ID": "CVE-2022-34383",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Edge Gateway 5200",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "1.03.10"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Dell Edge Gateway 5200 (EGW) versions before 1.03.10 contain an operating system command injection vulnerability. A local malicious user may potentially exploit this vulnerability by using an SMI to bypass PMC mitigation and gain arbitrary code execution during SMM."
                }
              ]
            },
            "impact": {
              "cvss": {
                "baseScore": 8.1,
                "baseSeverity": "High",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/kbdoc/en-us/000202711",
                  "refsource": "MISC",
                  "url": "https://www.dell.com/support/kbdoc/en-us/000202711"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2022-34383",
        "datePublished": "2022-08-31T20:05:16.529Z",
        "dateReserved": "2022-06-23T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:35:34.303Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }