CVE-2022-28172 (GCVE-0-2022-28172)
Vulnerability from nvd – Published: 2022-06-27 17:50 – Updated: 2024-09-17 01:10
VLAI
EPSS
VEX
Summary
The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to XSS attack by sending messages with malicious commands to the affected device.
Severity
6.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Affected:
V2.X , ≤ V2.3.8-6
(custom)
|
|
| hikvision | DS-A71024/48R-CVS,DS-A72024/48R-CVS |
Affected:
V1.X , ≤ V1.1.4
(custom)
|
Date Public
2022-06-23 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:37.258Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V2.3.8-6",
"status": "affected",
"version": "V2.X",
"versionType": "custom"
}
]
},
{
"product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V1.1.4",
"status": "affected",
"version": "V1.X",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Thurein Soe"
}
],
"datePublic": "2022-06-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to XSS attack by sending messages with malicious commands to the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-31T00:00:00.000Z",
"orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"shortName": "hikvision"
},
"references": [
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
}
],
"solutions": [
{
"lang": "en",
"value": "https://www.hikvision.com/content/dam/hikvision/en/support/cybersecyrity/security-advisory/Patch-for-Fixing-Security-Vulnerability-of-Hybrid-SAN-\u0026-Cluster-Storage.zip"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"assignerShortName": "hikvision",
"cveId": "CVE-2022-28172",
"datePublished": "2022-06-27T17:50:40.922Z",
"dateReserved": "2022-03-29T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:10:46.622Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28171 (GCVE-0-2022-28171)
Vulnerability from nvd – Published: 2022-06-27 17:48 – Updated: 2024-09-16 17:03
VLAI
EPSS
VEX
Summary
The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to execute restricted commands by sending messages with malicious commands to the affected device.
Severity
7.5 (High)
CWE
- CWE-78 - OS Command Injection
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Affected:
V2.X , ≤ V2.3.8-6
(custom)
|
|
| hikvision | DS-A71024/48R-CVS,DS-A72024/48R-CVS |
Affected:
V1.X , ≤ V1.1.4
(custom)
|
Date Public
2022-06-23 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:37.209Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/173653/Hikvision-Hybrid-SAN-Ds-a71024-SQL-Injection.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V2.3.8-6",
"status": "affected",
"version": "V2.X",
"versionType": "custom"
}
]
},
{
"product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V1.1.4",
"status": "affected",
"version": "V1.X",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Thurein Soe"
}
],
"datePublic": "2022-06-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to execute restricted commands by sending messages with malicious commands to the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-20T00:00:00.000Z",
"orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"shortName": "hikvision"
},
"references": [
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
},
{
"url": "http://packetstormsecurity.com/files/173653/Hikvision-Hybrid-SAN-Ds-a71024-SQL-Injection.html"
}
],
"solutions": [
{
"lang": "en",
"value": "https://www.hikvision.com/content/dam/hikvision/en/support/cybersecyrity/security-advisory/Patch-for-Fixing-Security-Vulnerability-of-Hybrid-SAN-\u0026-Cluster-Storage.zip"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"assignerShortName": "hikvision",
"cveId": "CVE-2022-28171",
"datePublished": "2022-06-27T17:48:51.569Z",
"dateReserved": "2022-03-29T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:03:49.464Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28172 (GCVE-0-2022-28172)
Vulnerability from cvelistv5 – Published: 2022-06-27 17:50 – Updated: 2024-09-17 01:10
VLAI
EPSS
VEX
Summary
The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to XSS attack by sending messages with malicious commands to the affected device.
Severity
6.5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Affected:
V2.X , ≤ V2.3.8-6
(custom)
|
|
| hikvision | DS-A71024/48R-CVS,DS-A72024/48R-CVS |
Affected:
V1.X , ≤ V1.1.4
(custom)
|
Date Public
2022-06-23 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:37.258Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V2.3.8-6",
"status": "affected",
"version": "V2.X",
"versionType": "custom"
}
]
},
{
"product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V1.1.4",
"status": "affected",
"version": "V1.X",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Thurein Soe"
}
],
"datePublic": "2022-06-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to XSS attack by sending messages with malicious commands to the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-31T00:00:00.000Z",
"orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"shortName": "hikvision"
},
"references": [
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
}
],
"solutions": [
{
"lang": "en",
"value": "https://www.hikvision.com/content/dam/hikvision/en/support/cybersecyrity/security-advisory/Patch-for-Fixing-Security-Vulnerability-of-Hybrid-SAN-\u0026-Cluster-Storage.zip"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"assignerShortName": "hikvision",
"cveId": "CVE-2022-28172",
"datePublished": "2022-06-27T17:50:40.922Z",
"dateReserved": "2022-03-29T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:10:46.622Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-28171 (GCVE-0-2022-28171)
Vulnerability from cvelistv5 – Published: 2022-06-27 17:48 – Updated: 2024-09-16 17:03
VLAI
EPSS
VEX
Summary
The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to execute restricted commands by sending messages with malicious commands to the affected device.
Severity
7.5 (High)
CWE
- CWE-78 - OS Command Injection
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| hikvision | DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D |
Affected:
V2.X , ≤ V2.3.8-6
(custom)
|
|
| hikvision | DS-A71024/48R-CVS,DS-A72024/48R-CVS |
Affected:
V1.X , ≤ V1.1.4
(custom)
|
Date Public
2022-06-23 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:48:37.209Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/173653/Hikvision-Hybrid-SAN-Ds-a71024-SQL-Injection.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DS-A71024/48/72R,DS-A80624S,DS-A81016S,DS-A72024/72R,DS-A80316S,DS-A82024D",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V2.3.8-6",
"status": "affected",
"version": "V2.X",
"versionType": "custom"
}
]
},
{
"product": "DS-A71024/48R-CVS,DS-A72024/48R-CVS",
"vendor": "hikvision",
"versions": [
{
"lessThanOrEqual": "V1.1.4",
"status": "affected",
"version": "V1.X",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Thurein Soe"
}
],
"datePublic": "2022-06-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to execute restricted commands by sending messages with malicious commands to the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-20T00:00:00.000Z",
"orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"shortName": "hikvision"
},
"references": [
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-some-hikvision-hybrid-san-products/"
},
{
"url": "http://packetstormsecurity.com/files/170818/Hikvision-Remote-Code-Execution-XSS-SQL-Injection.html"
},
{
"url": "http://packetstormsecurity.com/files/173653/Hikvision-Hybrid-SAN-Ds-a71024-SQL-Injection.html"
}
],
"solutions": [
{
"lang": "en",
"value": "https://www.hikvision.com/content/dam/hikvision/en/support/cybersecyrity/security-advisory/Patch-for-Fixing-Security-Vulnerability-of-Hybrid-SAN-\u0026-Cluster-Storage.zip"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"assignerShortName": "hikvision",
"cveId": "CVE-2022-28171",
"datePublished": "2022-06-27T17:48:51.569Z",
"dateReserved": "2022-03-29T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:03:49.464Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}