Search criteria

4 vulnerabilities found for dpc3928sl by technicolor

VAR-201704-0602

Vulnerability from variot - Updated: 2025-04-20 23:05

Certain Technicolor devices have an SNMP access-control bypass, possibly involving an ISP customization in some cases. The Technicolor (formerly Cisco) DPC3928SL with firmware D3928SL-P15-13-A386-c3420r55105-160127a could be reached by any SNMP community string from the Internet; also, you can write in the MIB because it provides write properties, aka Stringbleed. NOTE: the string-bleed/StringBleed-CVE-2017-5135 GitHub repository is not a valid reference as of 2017-04-27; it contains Trojan horse code purported to exploit this vulnerability. Technicolor ( Old Cisco) DPC3928SL There is an access control vulnerability in the firmware. In addition, GitHub Repository string-bleed/StringBleed-CVE-2017-5135 Is 2017 Year 4 Moon 27 Not valid as of the day. It may contain trojan code that exploits this vulnerability.Information may be obtained and information may be altered. Technicolor DPC3928SL is prone to an authentication-bypass vulnerability. Exploiting this issue may allow an attacker to bypass certain security restrictions and perform unauthorized actions. Technicolor DPC3928SL is a cable modem from the French Technicolor Group. A remote attacker could exploit this vulnerability to bypass access controls and execute code

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201704-0602",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dpc3928sl",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "technicolor",
        "version": "d3928sl-p15-13-a386-c3420r55105-160127a"
      },
      {
        "model": "dpc3928sl d3928sl-p15-13-a386-",
        "scope": null,
        "trust": 0.3,
        "vendor": "technicolor",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "98092"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003673"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-1498"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5135"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:technicolor:dpc3928sl_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003673"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Ezequiel Fernandez (Argentina) and Bertin Bervis (Costa Rica).",
    "sources": [
      {
        "db": "BID",
        "id": "98092"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2017-5135",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2017-5135",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-113338",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2017-5135",
            "impactScore": 5.2,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-5135",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-5135",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201704-1498",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-113338",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2017-5135",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-113338"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-5135"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003673"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-1498"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5135"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Certain Technicolor devices have an SNMP access-control bypass, possibly involving an ISP customization in some cases. The Technicolor (formerly Cisco) DPC3928SL with firmware D3928SL-P15-13-A386-c3420r55105-160127a could be reached by any SNMP community string from the Internet; also, you can write in the MIB because it provides write properties, aka Stringbleed. NOTE: the string-bleed/StringBleed-CVE-2017-5135 GitHub repository is not a valid reference as of 2017-04-27; it contains Trojan horse code purported to exploit this vulnerability. Technicolor ( Old Cisco) DPC3928SL There is an access control vulnerability in the firmware. In addition, GitHub Repository string-bleed/StringBleed-CVE-2017-5135 Is 2017 Year 4 Moon 27 Not valid as of the day. It may contain trojan code that exploits this vulnerability.Information may be obtained and information may be altered. Technicolor DPC3928SL is prone to an authentication-bypass vulnerability. \nExploiting this issue may allow an attacker to bypass certain security restrictions and perform unauthorized actions. Technicolor DPC3928SL is a cable modem from the French Technicolor Group. A remote attacker could exploit this vulnerability to bypass access controls and execute code",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-5135"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003673"
      },
      {
        "db": "BID",
        "id": "98092"
      },
      {
        "db": "VULHUB",
        "id": "VHN-113338"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-5135"
      }
    ],
    "trust": 2.07
  },
  "exploit_availability": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "reference": "https://www.scap.org.cn/vuln/vhn-113338",
        "trust": 0.1,
        "type": "unknown"
      },
      {
        "reference": "https://vulmon.com/exploitdetails?qidtp=exploitdb\u0026qid=43384",
        "trust": 0.1,
        "type": "exploit"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-113338"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-5135"
      }
    ]
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "BID",
        "id": "98092",
        "trust": 2.9
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5135",
        "trust": 2.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003673",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-1498",
        "trust": 0.7
      },
      {
        "db": "EXPLOIT-DB",
        "id": "43384",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-113338",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-5135",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-113338"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-5135"
      },
      {
        "db": "BID",
        "id": "98092"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003673"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-1498"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5135"
      }
    ]
  },
  "id": "VAR-201704-0602",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-113338"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2025-04-20T23:05:10.165000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.technicolor.com/"
      },
      {
        "title": "Brocade Security Advisories: BSA-2017-316",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=brocade_security_advisories\u0026qid=c2dee36877418c50b2cd2d6753b1608f"
      },
      {
        "title": "MS17-010",
        "trust": 0.1,
        "url": "https://github.com/oneplus-x/MS17-010 "
      },
      {
        "title": "awesome-hacking-lists",
        "trust": 0.1,
        "url": "https://github.com/udpsec/awesome-hacking-lists "
      },
      {
        "title": "awesome-hacking-lists",
        "trust": 0.1,
        "url": "https://github.com/NetW0rK1le3r/awesome-hacking-lists "
      },
      {
        "title": "awesome-hacking-lists",
        "trust": 0.1,
        "url": "https://github.com/taielab/awesome-hacking-lists "
      },
      {
        "title": "Exp101tsArchiv30thers",
        "trust": 0.1,
        "url": "https://github.com/nu11secur1ty/Exp101tsArchiv30thers "
      },
      {
        "title": "awesome-cve-poc_qazbnm456",
        "trust": 0.1,
        "url": "https://github.com/xbl3/awesome-cve-poc_qazbnm456 "
      },
      {
        "title": "BleepingComputer",
        "trust": 0.1,
        "url": "https://www.bleepingcomputer.com/news/security/several-cable-modem-models-affected-by-snmp-god-mode-flaw/"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2017-5135"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003673"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-284",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-113338"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003673"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5135"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.1,
        "url": "https://stringbleed.github.io/"
      },
      {
        "trust": 2.1,
        "url": "https://www.reddit.com/r/netsec/comments/67qt6u/cve_20175135_snmp_authentication_bypass/"
      },
      {
        "trust": 1.9,
        "url": "http://www.securityfocus.com/bid/98092"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-5135"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-5135"
      },
      {
        "trust": 0.8,
        "url": "http://www.securityfocus.com/bid/98092/info"
      },
      {
        "trust": 0.3,
        "url": "http://www.technicolorbroadbandpartner.com/"
      },
      {
        "trust": 0.3,
        "url": "https://github.com/string-bleed/stringbleed-cve-2017-5135"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.exploit-db.com/exploits/43384/"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/oneplus-x/ms17-010"
      },
      {
        "trust": 0.1,
        "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2017-316/"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-113338"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-5135"
      },
      {
        "db": "BID",
        "id": "98092"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003673"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-1498"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5135"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-113338"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-5135"
      },
      {
        "db": "BID",
        "id": "98092"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003673"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-1498"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5135"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-04-27T00:00:00",
        "db": "VULHUB",
        "id": "VHN-113338"
      },
      {
        "date": "2017-04-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-5135"
      },
      {
        "date": "2017-04-04T00:00:00",
        "db": "BID",
        "id": "98092"
      },
      {
        "date": "2017-06-02T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-003673"
      },
      {
        "date": "2017-04-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201704-1498"
      },
      {
        "date": "2017-04-27T15:59:00.150000",
        "db": "NVD",
        "id": "CVE-2017-5135"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-113338"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-5135"
      },
      {
        "date": "2017-05-02T00:11:00",
        "db": "BID",
        "id": "98092"
      },
      {
        "date": "2017-06-02T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-003673"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201704-1498"
      },
      {
        "date": "2025-04-20T01:37:25.860000",
        "db": "NVD",
        "id": "CVE-2017-5135"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-1498"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Technicolor DPC3928SL Vulnerabilities related to access control in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003673"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "access control error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-1498"
      }
    ],
    "trust": 0.6
  }
}

VAR-201812-0739

Vulnerability from variot - Updated: 2025-01-30 20:47

Technicolor DPC3928SL D3928SL-PSIP-13-A010-c3420r55105-170214a devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.4413.2.2.2.1.5.4.1.14.1.3.10001 and 1.3.6.1.4.1.4413.2.2.2.1.18.1.2.3.4.1.2.10001 SNMP requests. Technicolor DPC3928SL The device contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Technicolor DPC3928SL is a cable modem of the French Technicolor Group.

Technicolor DPC3928SL D3928SL-PSIP-13-A010-c3420r55105-170214a version has a security vulnerability

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0739",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dpc3928sl",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "technicolor",
        "version": "d3928sl-psip-13-a010-c3420r55105-170214a"
      },
      {
        "model": "dpc3928sl d3928sl-psip-13-a010-c3420r55105-170214a",
        "scope": null,
        "trust": 0.6,
        "vendor": "technicolor",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-42718"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013582"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1112"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20439"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:technicolor:dpc3928sl_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013582"
      }
    ]
  },
  "cve": "CVE-2018-20439",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-20439",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-42718",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-131245",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-20439",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-20439",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-20439",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-42718",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201812-1112",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-131245",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-42718"
      },
      {
        "db": "VULHUB",
        "id": "VHN-131245"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013582"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1112"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20439"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Technicolor DPC3928SL D3928SL-PSIP-13-A010-c3420r55105-170214a devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.4413.2.2.2.1.5.4.1.14.1.3.10001 and 1.3.6.1.4.1.4413.2.2.2.1.18.1.2.3.4.1.2.10001 SNMP requests. Technicolor DPC3928SL The device contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Technicolor DPC3928SL is a cable modem of the French Technicolor Group. \n\nTechnicolor DPC3928SL D3928SL-PSIP-13-A010-c3420r55105-170214a version has a security vulnerability",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-20439"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013582"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-42718"
      },
      {
        "db": "VULHUB",
        "id": "VHN-131245"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-20439",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013582",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1112",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-42718",
        "trust": 0.6
      },
      {
        "db": "OTHER",
        "id": "NONE",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-131245",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-42718"
      },
      {
        "db": "VULHUB",
        "id": "VHN-131245"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013582"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1112"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20439"
      }
    ]
  },
  "id": "VAR-201812-0739",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-42718"
      },
      {
        "db": "VULHUB",
        "id": "VHN-131245"
      }
    ],
    "trust": 1.8
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "network device"
        ],
        "sub_category": "router",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-42718"
      }
    ]
  },
  "last_update_date": "2025-01-30T20:47:20.183000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.technicolor.com/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013582"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-522",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-255",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-131245"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013582"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20439"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://misteralfa-hack.blogspot.com/2018/12/technicolor-passwords-wireless-via-snmp.html"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-20439"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-20439"
      },
      {
        "trust": 0.1,
        "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-42718"
      },
      {
        "db": "VULHUB",
        "id": "VHN-131245"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013582"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1112"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20439"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-42718"
      },
      {
        "db": "VULHUB",
        "id": "VHN-131245"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013582"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1112"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20439"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-11-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-42718"
      },
      {
        "date": "2018-12-25T00:00:00",
        "db": "VULHUB",
        "id": "VHN-131245"
      },
      {
        "date": "2019-02-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013582"
      },
      {
        "date": "2018-12-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201812-1112"
      },
      {
        "date": "2018-12-25T15:29:00.553000",
        "db": "NVD",
        "id": "CVE-2018-20439"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-11-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-42718"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-131245"
      },
      {
        "date": "2019-02-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013582"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201812-1112"
      },
      {
        "date": "2024-11-21T04:01:29.227000",
        "db": "NVD",
        "id": "CVE-2018-20439"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1112"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Technicolor DPC3928SL Vulnerabilities related to certificate and password management in devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013582"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1112"
      }
    ],
    "trust": 0.6
  }
}

VAR-201812-0685

Vulnerability from variot - Updated: 2024-11-23 23:01

plural Technicolor Product Contains a vulnerability related to certificate and password management.Information is acquired, information is falsified, and denial of service (DoS) May be in a state. Technicolor CGA0111 etc. are the modem products of the French Technicolor Group. A security vulnerability exists in several Technicolor products. A remote attacker could exploit this vulnerability to obtain credentials by sending SNMP requests. The following products and versions are affected: Technicolor CGA0111 CGA0111E-ES-13-E23E-c8000r5712-170217-0829-TRU ​​version; CWA0101 CWA0101E-A23E-c7000r5712-170315-SKC version; Version; TC7110.AR STD3.38.03 version; TC7110.B STC8.62.02 version; TC7110.D STDB.79.02 version; TC7200.d1I TC7200.d1IE-N23E-c7000r5712-170406-HAT version;

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0685",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "cga0111",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "technicolor",
        "version": "cga0111e-es-13-e23e-c8000r5712-170217-0829-tru"
      },
      {
        "model": "dpc3928sl",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "technicolor",
        "version": "d3928sl-psip-13-a010-c3420r55105-170214a"
      },
      {
        "model": "tc7110.ar",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "technicolor",
        "version": "std3.38.03"
      },
      {
        "model": "tc7110.b",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "technicolor",
        "version": "stc8.62.02"
      },
      {
        "model": "tc7110.d",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "technicolor",
        "version": "stdb.79.02"
      },
      {
        "model": "tc7200.d1i",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "technicolor",
        "version": "tc7200.d1ie-n23e-c7000r5712-170406-hat"
      },
      {
        "model": "tc7200.th2v2.d1i",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "technicolor",
        "version": "sc05.00.22"
      },
      {
        "model": "cga0101",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "technicolor",
        "version": "cwa0101e-a23e-c7000r5712-170315-skc"
      },
      {
        "model": "cwa0101",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "technicolor",
        "version": "cwa0101e-a23e-c7000r5712-170315-skc"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014543"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20393"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:technicolor:cga0111_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:technicolor:cwa0101_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:technicolor:dpc3928sl_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:technicolor:tc7110.ar_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:technicolor:tc7110.b_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:technicolor:tc7110.d_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:technicolor:tc7200.d1i_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:technicolor:tc7200.th2v2.d1i_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014543"
      }
    ]
  },
  "cve": "CVE-2018-20393",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-20393",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-131195",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-20393",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-20393",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-20393",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201812-1051",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-131195",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2018-20393",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-131195"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-20393"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014543"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1051"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20393"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural Technicolor Product Contains a vulnerability related to certificate and password management.Information is acquired, information is falsified, and denial of service (DoS) May be in a state. Technicolor CGA0111 etc. are the modem products of the French Technicolor Group. A security vulnerability exists in several Technicolor products. A remote attacker could exploit this vulnerability to obtain credentials by sending SNMP requests. The following products and versions are affected: Technicolor CGA0111 CGA0111E-ES-13-E23E-c8000r5712-170217-0829-TRU \u200b\u200bversion; CWA0101 CWA0101E-A23E-c7000r5712-170315-SKC version; Version; TC7110.AR STD3.38.03 version; TC7110.B STC8.62.02 version; TC7110.D STDB.79.02 version; TC7200.d1I TC7200.d1IE-N23E-c7000r5712-170406-HAT version;",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014543"
      },
      {
        "db": "VULHUB",
        "id": "VHN-131195"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-20393"
      }
    ],
    "trust": 0.9
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-20393",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014543",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1051",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-131195",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-20393",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-131195"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-20393"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014543"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1051"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20393"
      }
    ]
  },
  "id": "VAR-201812-0685",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-131195"
      }
    ],
    "trust": 0.7666666999999999
  },
  "last_update_date": "2024-11-23T23:01:58.198000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "TopPage",
        "trust": 0.8,
        "url": "https://www.technicolor.com/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014543"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-255",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-131195"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014543"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20393"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://github.com/ezelf/sensitivesoids/blob/master/oidpassswordleaks.csv"
      },
      {
        "trust": 1.8,
        "url": "https://misteralfa-hack.blogspot.com/2018/12/stringbleed-y-ahora-que-passwords-leaks.html"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-20393"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-20393"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-131195"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-20393"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014543"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1051"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20393"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-131195"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-20393"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014543"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1051"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20393"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-12-23T00:00:00",
        "db": "VULHUB",
        "id": "VHN-131195"
      },
      {
        "date": "2018-12-23T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-20393"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014543"
      },
      {
        "date": "2018-12-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201812-1051"
      },
      {
        "date": "2018-12-23T21:29:01.090000",
        "db": "NVD",
        "id": "CVE-2018-20393"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-131195"
      },
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-20393"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014543"
      },
      {
        "date": "2020-10-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201812-1051"
      },
      {
        "date": "2024-11-21T04:01:23.760000",
        "db": "NVD",
        "id": "CVE-2018-20393"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1051"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Technicolor Product Vulnerabilities in certificate and password management",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014543"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1051"
      }
    ],
    "trust": 0.6
  }
}

VAR-201812-0671

Vulnerability from variot - Updated: 2024-11-23 21:37

Technicolor DPC3928SL D3928SL-PSIP-13-A010-c3420r55105-160428a devices allow XSS via a Cross Protocol Injection attack with setSSID of 1.3.6.1.4.1.4413.2.2.2.1.18.1.2.1.1.3.10001. Technicolor DPC3928SL The device contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. The Technicolor DPC3928SL is a cable modem from the French Technicolor group. A remote attacker can exploit this vulnerability to inject arbitrary web scripts or HTML with the help of setSSID

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0671",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dpc3928sl",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "technicolor",
        "version": "d3928sl-psip-13-a010-c3420r55105-160428a"
      },
      {
        "model": "dpc3928sl",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "technicolor",
        "version": "psip-13-a010-c3420r55105-160428a"
      },
      {
        "model": "dpc3928sl d3928sl-psip-13-a010-c3420r55105-160428a",
        "scope": null,
        "trust": 0.6,
        "vendor": "technicolor",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-03479"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013420"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1037"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20379"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:technicolor:dpc3928sl_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013420"
      }
    ]
  },
  "cve": "CVE-2018-20379",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "HIGH",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 2.6,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 4.9,
            "id": "CVE-2018-20379",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "LOW",
            "trust": 1.8,
            "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "HIGH",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 2.6,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 4.9,
            "id": "CNVD-2019-03479",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.6,
            "id": "CVE-2018-20379",
            "impactScore": 2.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "trust": 1.8,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-20379",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-20379",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-03479",
            "trust": 0.6,
            "value": "LOW"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201812-1037",
            "trust": 0.6,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-03479"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013420"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1037"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20379"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Technicolor DPC3928SL D3928SL-PSIP-13-A010-c3420r55105-160428a devices allow XSS via a Cross Protocol Injection attack with setSSID of 1.3.6.1.4.1.4413.2.2.2.1.18.1.2.1.1.3.10001. Technicolor DPC3928SL The device contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. The Technicolor DPC3928SL is a cable modem from the French Technicolor group. A remote attacker can exploit this vulnerability to inject arbitrary web scripts or HTML with the help of setSSID",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-20379"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013420"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-03479"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-20379",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013420",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-03479",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1037",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-03479"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013420"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1037"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20379"
      }
    ]
  },
  "id": "VAR-201812-0671",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-03479"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-03479"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:37:55.393000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.technicolor.com/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013420"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-79",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013420"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20379"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://misteralfa-hack.blogspot.com/2018/12/cisco-dpc3928sl-explotando-un-xss-via.html"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-20379"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-20379"
      },
      {
        "trust": 0.6,
        "url": "https://www.technicolor.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-03479"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013420"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1037"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20379"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-03479"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013420"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1037"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20379"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-31T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-03479"
      },
      {
        "date": "2019-02-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013420"
      },
      {
        "date": "2018-12-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201812-1037"
      },
      {
        "date": "2018-12-23T21:29:00.247000",
        "db": "NVD",
        "id": "CVE-2018-20379"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-31T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-03479"
      },
      {
        "date": "2019-02-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013420"
      },
      {
        "date": "2018-12-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201812-1037"
      },
      {
        "date": "2024-11-21T04:01:21.713000",
        "db": "NVD",
        "id": "CVE-2018-20379"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1037"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Technicolor DPC3928SL Cross-Site Scripting Vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-03479"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1037"
      }
    ],
    "trust": 1.2
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "XSS",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-1037"
      }
    ],
    "trust": 0.6
  }
}