Search criteria
8 vulnerabilities found for deebot_t10_plus_firmware by ecovacs
CVE-2025-30200 (GCVE-0-2025-30200)
Vulnerability from nvd – Published: 2025-09-05 17:43 – Updated: 2025-09-08 18:22
VLAI?
Title
ECOVACS Vacuum and Base Station Hard-Coded AES Encryption
Summary
ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic AES encryption key, which can be easily derived.
Severity ?
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ECOVACS | DEEBOT X1 Series |
Affected:
*
|
|||||||||||||||||
|
|||||||||||||||||||
Credits
Dennis Giese, undefined
Braelynn Luedtke, undefined
Chris Anderson, undefined
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-30200",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:22:11.344266Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:22:21.457Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T20 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T30 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dennis Giese, undefined"
},
{
"lang": "en",
"value": "Braelynn Luedtke, undefined"
},
{
"lang": "en",
"value": "Chris Anderson, undefined"
}
],
"datePublic": "2025-07-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic AES encryption key, which can be easily derived."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 2.3,
"baseSeverity": "LOW",
"privilegesRequired": "NONE",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW"
}
},
{
"other": {
"content": {
"id": "CVE-2025-30200",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:11:07.109909Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321 Use of Hard-coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:11:26.081Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"name": "url",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-19"
},
{
"name": "url",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-135-19.json"
},
{
"name": "url",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30200"
}
],
"title": "ECOVACS Vacuum and Base Station Hard-Coded AES Encryption"
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2025-30200",
"datePublished": "2025-09-05T17:43:20.802Z",
"dateReserved": "2025-03-18T15:53:26.926Z",
"dateUpdated": "2025-09-08T18:22:21.457Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-30199 (GCVE-0-2025-30199)
Vulnerability from nvd – Published: 2025-09-05 17:45 – Updated: 2025-09-08 18:21
VLAI?
Title
ECOVACS Vacuum and Base Station accept unsigned firmware
Summary
ECOVACS vacuum robot base stations do not validate firmware updates, so malicious over-the-air updates can be sent to base station via insecure connection between robot and base station.
Severity ?
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ECOVACS | DEEBOT X1 Series |
Affected:
*
|
|||||||||||||||||
|
|||||||||||||||||||
Credits
Dennis Giese, undefined
Braelynn Luedtke, undefined
Chris Anderson, undefined
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-30199",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:20:48.723390Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:21:06.626Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T20 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T30 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dennis Giese, undefined"
},
{
"lang": "en",
"value": "Braelynn Luedtke, undefined"
},
{
"lang": "en",
"value": "Chris Anderson, undefined"
}
],
"datePublic": "2025-07-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ECOVACS vacuum robot base stations do not validate firmware updates, so malicious over-the-air updates can be sent to base station via insecure connection between robot and base station."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH"
}
},
{
"other": {
"content": {
"id": "CVE-2025-30199",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:09:57.869806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:10:36.047Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"name": "url",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-19"
},
{
"name": "url",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-135-19.json"
},
{
"name": "url",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30199"
}
],
"title": "ECOVACS Vacuum and Base Station accept unsigned firmware"
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2025-30199",
"datePublished": "2025-09-05T17:45:07.227Z",
"dateReserved": "2025-03-18T15:53:08.738Z",
"dateUpdated": "2025-09-08T18:21:06.626Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-30198 (GCVE-0-2025-30198)
Vulnerability from nvd – Published: 2025-09-05 17:45 – Updated: 2025-09-08 18:20
VLAI?
Title
ECOVACS Vacuum and Base Station Hard-Coded WPA2-PSK
Summary
ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic WPA2-PSK, which can be easily derived.
Severity ?
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ECOVACS | DEEBOT X1 Series |
Affected:
*
|
|||||||||||||||||
|
|||||||||||||||||||
Credits
Dennis Giese, undefined
Braelynn Luedtke, undefined
Chris Anderson, undefined
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-30198",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:20:11.799443Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:20:26.088Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T20 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T30 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dennis Giese, undefined"
},
{
"lang": "en",
"value": "Braelynn Luedtke, undefined"
},
{
"lang": "en",
"value": "Chris Anderson, undefined"
}
],
"datePublic": "2025-07-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic WPA2-PSK, which can be easily derived."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 2.3,
"baseSeverity": "LOW",
"privilegesRequired": "NONE",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW"
}
},
{
"other": {
"content": {
"id": "CVE-2025-30198",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:08:40.565084Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321 Use of Hard-coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:09:16.263Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"name": "url",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-19"
},
{
"name": "url",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-135-19.json"
},
{
"name": "url",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30198"
}
],
"title": "ECOVACS Vacuum and Base Station Hard-Coded WPA2-PSK"
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2025-30198",
"datePublished": "2025-09-05T17:45:36.945Z",
"dateReserved": "2025-03-18T15:52:43.925Z",
"dateUpdated": "2025-09-08T18:20:26.088Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-52330 (GCVE-0-2024-52330)
Vulnerability from nvd – Published: 2025-01-23 16:36 – Updated: 2025-02-12 20:41
VLAI?
Title
ECOVACS lawnmowers and vacuums do not properly validate TLS certificates
Summary
ECOVACS lawnmowers and vacuums do not properly validate TLS certificates. An unauthenticated attacker can read or modify TLS traffic, possibly modifying firmware updates.
Severity ?
7.4 (High)
CWE
- CWE-295 - Improper Certificate Validation
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ECOVACS | DEEBOT X5 PRO PLUS |
Unaffected:
1.38.0
Affected: 0 , < 1.38.0 (custom) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-52330",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-23T16:56:31.855219Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T20:41:28.969Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "DEEBOT X5 PRO PLUS",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.38.0"
},
{
"lessThan": "1.38.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X5 PRO",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.70.0"
},
{
"lessThan": "1.70.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X2S",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "1.49.0",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.49.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X2 OMNI",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.76.6"
},
{
"lessThan": "1.76.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 TURBO",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "2.4.41",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.4.41"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.7.3"
},
{
"lessThan": "1.7.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1S PRO",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "2.5.31"
},
{
"lessThan": "2.5.31",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1e OMNI",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "2.4.42"
},
{
"lessThan": "2.4.42",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 PLUS",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.7.5"
},
{
"lessThan": "1.7.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 OMNI",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "1.9.0",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.9.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X5 PRO ULTRA",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "1.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.17.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mate X",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.44.18"
},
{
"lessThan": "1.44.18",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X2 PRO",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.76.6"
},
{
"lessThan": "1.76.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X2 COMBO",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "1.81.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.81.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 OMNI",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "2.4.41",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.4.41"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 PRO OMNI",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "2.4.41"
},
{
"lessThan": "2.4.41",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 PLUS",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.7.3"
},
{
"lessThan": "1.7.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1S PRO PLUS",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.23.0"
},
{
"lessThan": "1.23.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 TURBO",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.10.0"
},
{
"lessThan": "1.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "1.7.5",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.7.5"
}
]
}
],
"datePublic": "2023-12-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ECOVACS lawnmowers and vacuums do not properly validate TLS certificates. An unauthenticated attacker can read or modify TLS traffic, possibly modifying firmware updates."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS"
},
{
"cvssV4_0": {
"baseScore": 9.5,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:H",
"version": "4.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295 Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-23T16:36:50.128Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"name": "url",
"url": "https://dontvacuum.me/talks/HITCON2024/HITCON-CMT-2024_Ecovacs.pdf"
},
{
"name": "url",
"url": "https://dontvacuum.me/talks/37c3-2023/37c3-vacuuming-and-mowing.pdf"
},
{
"name": "url",
"url": "https://www.ecovacs.com/global/userhelp/dsa20241217001"
}
],
"title": "ECOVACS lawnmowers and vacuums do not properly validate TLS certificates"
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2024-52330",
"datePublished": "2025-01-23T16:36:50.128Z",
"dateReserved": "2024-11-08T01:06:02.405Z",
"dateUpdated": "2025-02-12T20:41:28.969Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-30198 (GCVE-0-2025-30198)
Vulnerability from cvelistv5 – Published: 2025-09-05 17:45 – Updated: 2025-09-08 18:20
VLAI?
Title
ECOVACS Vacuum and Base Station Hard-Coded WPA2-PSK
Summary
ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic WPA2-PSK, which can be easily derived.
Severity ?
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ECOVACS | DEEBOT X1 Series |
Affected:
*
|
|||||||||||||||||
|
|||||||||||||||||||
Credits
Dennis Giese, undefined
Braelynn Luedtke, undefined
Chris Anderson, undefined
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-30198",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:20:11.799443Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:20:26.088Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T20 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T30 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dennis Giese, undefined"
},
{
"lang": "en",
"value": "Braelynn Luedtke, undefined"
},
{
"lang": "en",
"value": "Chris Anderson, undefined"
}
],
"datePublic": "2025-07-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic WPA2-PSK, which can be easily derived."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 2.3,
"baseSeverity": "LOW",
"privilegesRequired": "NONE",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW"
}
},
{
"other": {
"content": {
"id": "CVE-2025-30198",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:08:40.565084Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321 Use of Hard-coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:09:16.263Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"name": "url",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-19"
},
{
"name": "url",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-135-19.json"
},
{
"name": "url",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30198"
}
],
"title": "ECOVACS Vacuum and Base Station Hard-Coded WPA2-PSK"
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2025-30198",
"datePublished": "2025-09-05T17:45:36.945Z",
"dateReserved": "2025-03-18T15:52:43.925Z",
"dateUpdated": "2025-09-08T18:20:26.088Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-30199 (GCVE-0-2025-30199)
Vulnerability from cvelistv5 – Published: 2025-09-05 17:45 – Updated: 2025-09-08 18:21
VLAI?
Title
ECOVACS Vacuum and Base Station accept unsigned firmware
Summary
ECOVACS vacuum robot base stations do not validate firmware updates, so malicious over-the-air updates can be sent to base station via insecure connection between robot and base station.
Severity ?
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ECOVACS | DEEBOT X1 Series |
Affected:
*
|
|||||||||||||||||
|
|||||||||||||||||||
Credits
Dennis Giese, undefined
Braelynn Luedtke, undefined
Chris Anderson, undefined
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-30199",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:20:48.723390Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:21:06.626Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T20 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T30 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dennis Giese, undefined"
},
{
"lang": "en",
"value": "Braelynn Luedtke, undefined"
},
{
"lang": "en",
"value": "Chris Anderson, undefined"
}
],
"datePublic": "2025-07-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ECOVACS vacuum robot base stations do not validate firmware updates, so malicious over-the-air updates can be sent to base station via insecure connection between robot and base station."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH"
}
},
{
"other": {
"content": {
"id": "CVE-2025-30199",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:09:57.869806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:10:36.047Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"name": "url",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-19"
},
{
"name": "url",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-135-19.json"
},
{
"name": "url",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30199"
}
],
"title": "ECOVACS Vacuum and Base Station accept unsigned firmware"
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2025-30199",
"datePublished": "2025-09-05T17:45:07.227Z",
"dateReserved": "2025-03-18T15:53:08.738Z",
"dateUpdated": "2025-09-08T18:21:06.626Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-30200 (GCVE-0-2025-30200)
Vulnerability from cvelistv5 – Published: 2025-09-05 17:43 – Updated: 2025-09-08 18:22
VLAI?
Title
ECOVACS Vacuum and Base Station Hard-Coded AES Encryption
Summary
ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic AES encryption key, which can be easily derived.
Severity ?
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ECOVACS | DEEBOT X1 Series |
Affected:
*
|
|||||||||||||||||
|
|||||||||||||||||||
Credits
Dennis Giese, undefined
Braelynn Luedtke, undefined
Chris Anderson, undefined
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-30200",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:22:11.344266Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:22:21.457Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T20 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T30 Series",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Dennis Giese, undefined"
},
{
"lang": "en",
"value": "Braelynn Luedtke, undefined"
},
{
"lang": "en",
"value": "Chris Anderson, undefined"
}
],
"datePublic": "2025-07-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ECOVACS robot vacuums and base stations communicate via an insecure Wi-Fi network with a deterministic AES encryption key, which can be easily derived."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 2.3,
"baseSeverity": "LOW",
"privilegesRequired": "NONE",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW"
}
},
{
"other": {
"content": {
"id": "CVE-2025-30200",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:11:07.109909Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321 Use of Hard-coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T18:11:26.081Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"name": "url",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-19"
},
{
"name": "url",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-135-19.json"
},
{
"name": "url",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30200"
}
],
"title": "ECOVACS Vacuum and Base Station Hard-Coded AES Encryption"
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2025-30200",
"datePublished": "2025-09-05T17:43:20.802Z",
"dateReserved": "2025-03-18T15:53:26.926Z",
"dateUpdated": "2025-09-08T18:22:21.457Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-52330 (GCVE-0-2024-52330)
Vulnerability from cvelistv5 – Published: 2025-01-23 16:36 – Updated: 2025-02-12 20:41
VLAI?
Title
ECOVACS lawnmowers and vacuums do not properly validate TLS certificates
Summary
ECOVACS lawnmowers and vacuums do not properly validate TLS certificates. An unauthenticated attacker can read or modify TLS traffic, possibly modifying firmware updates.
Severity ?
7.4 (High)
CWE
- CWE-295 - Improper Certificate Validation
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ECOVACS | DEEBOT X5 PRO PLUS |
Unaffected:
1.38.0
Affected: 0 , < 1.38.0 (custom) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-52330",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-23T16:56:31.855219Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T20:41:28.969Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "DEEBOT X5 PRO PLUS",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.38.0"
},
{
"lessThan": "1.38.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X5 PRO",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.70.0"
},
{
"lessThan": "1.70.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X2S",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "1.49.0",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.49.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X2 OMNI",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.76.6"
},
{
"lessThan": "1.76.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 TURBO",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "2.4.41",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.4.41"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.7.3"
},
{
"lessThan": "1.7.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1S PRO",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "2.5.31"
},
{
"lessThan": "2.5.31",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1e OMNI",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "2.4.42"
},
{
"lessThan": "2.4.42",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 PLUS",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.7.5"
},
{
"lessThan": "1.7.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 OMNI",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "1.9.0",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.9.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X5 PRO ULTRA",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "1.17.0",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.17.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mate X",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.44.18"
},
{
"lessThan": "1.44.18",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X2 PRO",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.76.6"
},
{
"lessThan": "1.76.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X2 COMBO",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "1.81.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.81.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 OMNI",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "2.4.41",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.4.41"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 PRO OMNI",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "2.4.41"
},
{
"lessThan": "2.4.41",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1 PLUS",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.7.3"
},
{
"lessThan": "1.7.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT X1S PRO PLUS",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.23.0"
},
{
"lessThan": "1.23.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10 TURBO",
"vendor": "ECOVACS",
"versions": [
{
"status": "unaffected",
"version": "1.10.0"
},
{
"lessThan": "1.10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DEEBOT T10",
"vendor": "ECOVACS",
"versions": [
{
"lessThan": "1.7.5",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.7.5"
}
]
}
],
"datePublic": "2023-12-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ECOVACS lawnmowers and vacuums do not properly validate TLS certificates. An unauthenticated attacker can read or modify TLS traffic, possibly modifying firmware updates."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS"
},
{
"cvssV4_0": {
"baseScore": 9.5,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:H",
"version": "4.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295 Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-23T16:36:50.128Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"name": "url",
"url": "https://dontvacuum.me/talks/HITCON2024/HITCON-CMT-2024_Ecovacs.pdf"
},
{
"name": "url",
"url": "https://dontvacuum.me/talks/37c3-2023/37c3-vacuuming-and-mowing.pdf"
},
{
"name": "url",
"url": "https://www.ecovacs.com/global/userhelp/dsa20241217001"
}
],
"title": "ECOVACS lawnmowers and vacuums do not properly validate TLS certificates"
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2024-52330",
"datePublished": "2025-01-23T16:36:50.128Z",
"dateReserved": "2024-11-08T01:06:02.405Z",
"dateUpdated": "2025-02-12T20:41:28.969Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}