Search criteria

5 vulnerabilities found for dcs-5020l by dlink

VAR-202505-2067

Vulnerability from variot - Updated: 2025-06-07 23:45

A vulnerability classified as critical has been found in D-Link DCS-5020L 1.01_B2. This affects the function websReadEvent of the file /rame/ptdc.cgi. The manipulation of the argument Authorization leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. D-Link Systems, Inc. of DCS-5020L An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. D-Link DCS-5020L is a DCS series IP camera from D-Link of China.

D-Link DCS-5020L has a buffer overflow vulnerability. The vulnerability is caused by the failure of the parameter Authorization in the file /rame/ptdc.cgi to correctly verify the length of the input data. Attackers can use this vulnerability to execute arbitrary code on the system or cause a denial of service

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202505-2067",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dcs-5020l",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.01_b2"
      },
      {
        "model": "dcs-5020l",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5020l",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "d link",
        "version": "dcs-5020l  firmware  1.01 b2"
      },
      {
        "model": "dcs-5020l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5020l 1.01 b2",
        "scope": null,
        "trust": 0.6,
        "vendor": "d link",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-11224"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-006405"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-5215"
      }
    ]
  },
  "cve": "CVE-2025-5215",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2025-5215",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-006405",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2025-11224",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-5215",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2025-5215",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-006405",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2025-5215",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2025-5215",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-006405",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-11224",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-11224"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-006405"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-5215"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-5215"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability classified as critical has been found in D-Link DCS-5020L 1.01_B2. This affects the function websReadEvent of the file /rame/ptdc.cgi. The manipulation of the argument Authorization leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. D-Link Systems, Inc. of DCS-5020L An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. D-Link DCS-5020L is a DCS series IP camera from D-Link of China. \n\nD-Link DCS-5020L has a buffer overflow vulnerability. The vulnerability is caused by the failure of the parameter Authorization in the file /rame/ptdc.cgi to correctly verify the length of the input data. Attackers can use this vulnerability to execute arbitrary code on the system or cause a denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-5215"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-006405"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-11224"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-5215",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "310311",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-006405",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-11224",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-11224"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-006405"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-5215"
      }
    ]
  },
  "id": "VAR-202505-2067",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-11224"
      }
    ],
    "trust": 1.2363636
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-11224"
      }
    ]
  },
  "last_update_date": "2025-06-07T23:45:30.659000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-119",
        "trust": 1.0
      },
      {
        "problemtype": "Buffer error (CWE-119) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-006405"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-5215"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/xiaobor123/vul-dlink-dcs5020l"
      },
      {
        "trust": 1.8,
        "url": "https://github.com/xiaobor123/vul-dlink-dcs5020l#poc"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.310311"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.582935"
      },
      {
        "trust": 1.8,
        "url": "https://www.dlink.com/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-5215"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.310311"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-11224"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-006405"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-5215"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-11224"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-006405"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-5215"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-11224"
      },
      {
        "date": "2025-06-06T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-006405"
      },
      {
        "date": "2025-05-27T00:15:32.127000",
        "db": "NVD",
        "id": "CVE-2025-5215"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-11224"
      },
      {
        "date": "2025-06-06T07:47:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-006405"
      },
      {
        "date": "2025-06-05T15:59:44.683000",
        "db": "NVD",
        "id": "CVE-2025-5215"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "D-Link\u00a0Systems,\u00a0Inc.\u00a0 of \u00a0DCS-5020L\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-006405"
      }
    ],
    "trust": 0.8
  }
}

VAR-201704-1588

Vulnerability from variot - Updated: 2025-04-20 22:12

D-Link DCS cameras have a weak/insecure CrossDomain.XML file that allows sites hosting malicious Flash objects to access and/or change the device's settings via a CSRF attack. This is because of the 'allow-access-from domain' child element set to *, thus accepting requests from any domain. If a victim logged into the camera's web console visits a malicious site hosting a malicious Flash file from another Browser tab, the malicious Flash file then can send requests to the victim's DCS series Camera without knowing the credentials. An attacker can host a malicious Flash file that can retrieve Live Feeds or information from the victim's DCS series Camera, add new admin users, or make other changes to the device. Known affected devices are DCS-933L with firmware before 1.13.05, DCS-5030L, DCS-5020L, DCS-2530L, DCS-2630L, DCS-930L, DCS-932L, and DCS-932LB1. plural D-Link DCS The camera contains a cross-site request forgery vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) An attack may be carried out. D-LinkDCS-933L is a wireless surveillance camera device from D-Link. There are security holes in several D-LinkDCS cameras. D-Link DCS-933L, etc. The following products are affected: D-Link DCS-5030L; DCS-5020L; DCS-2530L; DCS-2630L;

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201704-1588",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dcs-5009l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.07.05"
      },
      {
        "model": "dcs-7010l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.08.01"
      },
      {
        "model": "dcs-2136l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.04.01"
      },
      {
        "model": "dcs-930l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2.13.15"
      },
      {
        "model": "dcs-2330l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.13.00"
      },
      {
        "model": "dcs-931l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.13.05"
      },
      {
        "model": "dcs-2310l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.08.01"
      },
      {
        "model": "dcs-5000l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.02.02"
      },
      {
        "model": "dcs-5222l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2.12.00"
      },
      {
        "model": "dcs-942l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2.11.03"
      },
      {
        "model": "dcs-2132l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.08.01"
      },
      {
        "model": "dcs-932l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2.13.15"
      },
      {
        "model": "dcs-2310l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2.03.00"
      },
      {
        "model": "dcs-932l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.13.04"
      },
      {
        "model": "dcs-6212l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00.12"
      },
      {
        "model": "dcs-2132l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2.12.00"
      },
      {
        "model": "dcs-7000l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.04.00"
      },
      {
        "model": "dcs-5025l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.02.10"
      },
      {
        "model": "dcs-5029l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.12.00"
      },
      {
        "model": "dcs-942l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.27"
      },
      {
        "model": "dcs-5010l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.13.05"
      },
      {
        "model": "dcs-5020l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.13.05"
      },
      {
        "model": "dcs-930l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.15.04"
      },
      {
        "model": "dcs-934l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.04.15"
      },
      {
        "model": "dcs-2210l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.03.01"
      },
      {
        "model": "dcs-6010l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.15.01"
      },
      {
        "model": "dcs-2530l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00.21"
      },
      {
        "model": "dcs-2332l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.08.01"
      },
      {
        "model": "dcs-5030l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.01.06"
      },
      {
        "model": "dcs-2230l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.03.01"
      },
      {
        "model": "dcs-933l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.13.05"
      },
      {
        "model": "dcs-2132l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-2136l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-2210l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-2230l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-2310l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-2330l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-2332l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-2530l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5000l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5009l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5010l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5020l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5025l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5029l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5030l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5222l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-6010l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-6212l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-7000l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-7010l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-930l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-931l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-932l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-933l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-934l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-942l",
        "scope": null,
        "trust": 0.8,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.13.05"
      },
      {
        "model": "dcs-933l",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.13.05"
      },
      {
        "model": "dcs-5030l",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.13.05"
      },
      {
        "model": "dcs-5020l",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.13.05"
      },
      {
        "model": "dcs-2530l",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.13.05"
      },
      {
        "model": "dcs-2630l",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.13.05"
      },
      {
        "model": "dcs-7000l",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.04.00"
      },
      {
        "model": "dcs-2136l",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.04.01"
      },
      {
        "model": "dcs-5000l",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.02.02"
      },
      {
        "model": "dcs-5029l",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.12.00"
      },
      {
        "model": "dcs-2310l",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "2.03.00"
      },
      {
        "model": "dcs-2330l",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.13.00"
      },
      {
        "model": "dcs-2132l",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "2.12.00"
      },
      {
        "model": "dcs-2132l",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.08.01"
      },
      {
        "model": "dcs-2210l",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.03.01"
      },
      {
        "model": "dcs-5025l",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.02.10"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "dcs 932l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "dcs 942l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "dcs 2310l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "dcs 2132l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "dcs 930l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 2230l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 934l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 931l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 933l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5009l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5010l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5020l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5000l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5025l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5030l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 2210l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 2136l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 7000l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 6212l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5222l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5029l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 2332l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 2330l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 6010l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 7010l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 2530l",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06729"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003648"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-783"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-7852"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-2132l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-2136l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-2210l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-2230l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-2310l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-2330l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-2332l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-2530l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5000l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5009l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5010l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5020l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5025l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5029l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5030l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5222l__firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-6010l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-6212l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-7000l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-7010l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-930l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-931l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-932l_camera_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-933l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-934l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-942l_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003648"
      }
    ]
  },
  "cve": "CVE-2017-7852",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2017-7852",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2017-06729",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "VHN-116055",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2017-7852",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2017-7852",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-7852",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-7852",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-06729",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201704-783",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-116055",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06729"
      },
      {
        "db": "VULHUB",
        "id": "VHN-116055"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003648"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-783"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-7852"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "D-Link DCS cameras have a weak/insecure CrossDomain.XML file that allows sites hosting malicious Flash objects to access and/or change the device\u0027s settings via a CSRF attack. This is because of the \u0027allow-access-from domain\u0027 child element set to *, thus accepting requests from any domain. If a victim logged into the camera\u0027s web console visits a malicious site hosting a malicious Flash file from another Browser tab, the malicious Flash file then can send requests to the victim\u0027s DCS series Camera without knowing the credentials. An attacker can host a malicious Flash file that can retrieve Live Feeds or information from the victim\u0027s DCS series Camera, add new admin users, or make other changes to the device. Known affected devices are DCS-933L with firmware before 1.13.05, DCS-5030L, DCS-5020L, DCS-2530L, DCS-2630L, DCS-930L, DCS-932L, and DCS-932LB1. plural D-Link DCS The camera contains a cross-site request forgery vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) An attack may be carried out. D-LinkDCS-933L is a wireless surveillance camera device from D-Link. There are security holes in several D-LinkDCS cameras. D-Link DCS-933L, etc. The following products are affected: D-Link DCS-5030L; DCS-5020L; DCS-2530L; DCS-2630L;",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-7852"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003648"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06729"
      },
      {
        "db": "IVD",
        "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
      },
      {
        "db": "VULHUB",
        "id": "VHN-116055"
      }
    ],
    "trust": 2.43
  },
  "exploit_availability": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "reference": "https://www.scap.org.cn/vuln/vhn-116055",
        "trust": 0.1,
        "type": "unknown"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-116055"
      }
    ]
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-7852",
        "trust": 3.4
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-783",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06729",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003648",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "76B829DA-D734-4842-BAE5-3DD9FF5F23DC",
        "trust": 0.2
      },
      {
        "db": "OTHER",
        "id": "NONE",
        "trust": 0.1
      },
      {
        "db": "EXPLOIT-DB",
        "id": "42074",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "142702",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-116055",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "IVD",
        "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06729"
      },
      {
        "db": "VULHUB",
        "id": "VHN-116055"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003648"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-783"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-7852"
      }
    ]
  },
  "id": "VAR-201704-1588",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "IVD",
        "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06729"
      },
      {
        "db": "VULHUB",
        "id": "VHN-116055"
      }
    ],
    "trust": 1.675429490909091
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "IoT",
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      },
      {
        "category": [
          "camera device"
        ],
        "sub_category": "camera",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "IVD",
        "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06729"
      }
    ]
  },
  "last_update_date": "2025-04-20T22:12:28.666000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://us.dlink.com/"
      },
      {
        "title": "Patch for D-LinkDCS Cross-site Forgery Request Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/93817"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-06729"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003648"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-352",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-116055"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003648"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-7852"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://www.qualys.com/2017/02/22/qsa-2017-02-22/qsa-2017-02-22.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-7852"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-7852"
      },
      {
        "trust": 0.1,
        "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06729"
      },
      {
        "db": "VULHUB",
        "id": "VHN-116055"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003648"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-783"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-7852"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "IVD",
        "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06729"
      },
      {
        "db": "VULHUB",
        "id": "VHN-116055"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003648"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-783"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-7852"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-16T00:00:00",
        "db": "IVD",
        "id": "76b829da-d734-4842-bae5-3dd9ff5f23dc"
      },
      {
        "date": "2017-05-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-06729"
      },
      {
        "date": "2017-04-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-116055"
      },
      {
        "date": "2017-06-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-003648"
      },
      {
        "date": "2017-04-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201704-783"
      },
      {
        "date": "2017-04-24T10:59:00.160000",
        "db": "NVD",
        "id": "CVE-2017-7852"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-06729"
      },
      {
        "date": "2017-05-08T00:00:00",
        "db": "VULHUB",
        "id": "VHN-116055"
      },
      {
        "date": "2017-06-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-003648"
      },
      {
        "date": "2021-04-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201704-783"
      },
      {
        "date": "2025-04-20T01:37:25.860000",
        "db": "NVD",
        "id": "CVE-2017-7852"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-783"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  D-Link DCS Cross-site request forgery vulnerability in camera",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-003648"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "cross-site request forgery",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201704-783"
      }
    ],
    "trust": 0.6
  }
}

VAR-201905-1066

Vulnerability from variot - Updated: 2025-01-30 20:44

The D-Link DCS series of Wi-Fi cameras contains a stack-based buffer overflow in alphapd, the camera's web server. The overflow allows a remotely authenticated attacker to execute arbitrary code by providing a long string in the WEPEncryption parameter when requesting wireless.htm. Vulnerable devices include DCS-5009L (1.08.11 and below), DCS-5010L (1.14.09 and below), DCS-5020L (1.15.12 and below), DCS-5025L (1.03.07 and below), DCS-5030L (1.04.10 and below), DCS-930L (2.16.01 and below), DCS-931L (1.14.11 and below), DCS-932L (2.17.01 and below), DCS-933L (1.14.11 and below), and DCS-934L (1.05.04 and below). plural D-Link DCS series Product Wi-Fi camera Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. D-Link DCS-5009L and so on are all DCS series IP cameras produced by Taiwan D-Link Company. Alphapd in several D-Link products has a stack-based buffer overflow vulnerability. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc. The following products and versions are affected: D-Link DCS-5009L 1.08.11 and earlier; DCS-5010L 1.14.09 and earlier; DCS-5020L 1.15.12 and earlier; DCS-5025L 1.03.07 and earlier; DCS-5030L 1.04.10 and earlier; DCS-930L 2.16.01 and earlier; DCS-931L 1.14.11 and earlier; DCS-932L 2.17.01 and earlier; DCS-933L 1.14.11 and earlier; DCS-934L 1.05.04 and earlier versions

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201905-1066",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dcs-934l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.05.04"
      },
      {
        "model": "dcs-5030l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.04.10"
      },
      {
        "model": "dcs-5009l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.08.11"
      },
      {
        "model": "dcs-932l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2.17.01"
      },
      {
        "model": "dcs-931l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.14.11"
      },
      {
        "model": "dcs-933l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.14.11"
      },
      {
        "model": "dcs-5025l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.03.07"
      },
      {
        "model": "dcs-930l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "2.16.01"
      },
      {
        "model": "dcs-5010l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.14.09"
      },
      {
        "model": "dcs-5020l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.15.12"
      },
      {
        "model": "dcs-5009l",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "1.08.11"
      },
      {
        "model": "dcs-5010l",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "1.14.09"
      },
      {
        "model": "dcs-5020l",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "1.15.12"
      },
      {
        "model": "dcs-5025l",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "1.03.07"
      },
      {
        "model": "dcs-5030l",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "1.04.10"
      },
      {
        "model": "dcs-930l",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "2.16.01"
      },
      {
        "model": "dcs-931l",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "1.14.11"
      },
      {
        "model": "dcs-932l",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "2.17.01"
      },
      {
        "model": "dcs-933l",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "1.14.11"
      },
      {
        "model": "dcs-934l",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "1.05.04"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004361"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10999"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5009l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5010l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5020l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5025l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5030l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-930l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-931l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-932l_camera_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-933l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-934l_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004361"
      }
    ]
  },
  "cve": "CVE-2019-10999",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CVE-2019-10999",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "VHN-142601",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2019-10999",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-10999",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-10999",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201905-138",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-142601",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2019-10999",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-142601"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-10999"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004361"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-138"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10999"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The D-Link DCS series of Wi-Fi cameras contains a stack-based buffer overflow in alphapd, the camera\u0027s web server. The overflow allows a remotely authenticated attacker to execute arbitrary code by providing a long string in the WEPEncryption parameter when requesting wireless.htm. Vulnerable devices include DCS-5009L (1.08.11 and below), DCS-5010L (1.14.09 and below), DCS-5020L (1.15.12 and below), DCS-5025L (1.03.07 and below), DCS-5030L (1.04.10 and below), DCS-930L (2.16.01 and below), DCS-931L (1.14.11 and below), DCS-932L (2.17.01 and below), DCS-933L (1.14.11 and below), and DCS-934L (1.05.04 and below). plural D-Link DCS series Product Wi-Fi camera Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. D-Link DCS-5009L and so on are all DCS series IP cameras produced by Taiwan D-Link Company. Alphapd in several D-Link products has a stack-based buffer overflow vulnerability. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc. The following products and versions are affected: D-Link DCS-5009L 1.08.11 and earlier; DCS-5010L 1.14.09 and earlier; DCS-5020L 1.15.12 and earlier; DCS-5025L 1.03.07 and earlier; DCS-5030L 1.04.10 and earlier; DCS-930L 2.16.01 and earlier; DCS-931L 1.14.11 and earlier; DCS-932L 2.17.01 and earlier; DCS-933L 1.14.11 and earlier; DCS-934L 1.05.04 and earlier versions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-10999"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004361"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142601"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-10999"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-10999",
        "trust": 2.7
      },
      {
        "db": "DLINK",
        "id": "SAP10131",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004361",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-138",
        "trust": 0.7
      },
      {
        "db": "OTHER",
        "id": "NONE",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-142601",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-10999",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-142601"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-10999"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004361"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-138"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10999"
      }
    ]
  },
  "id": "VAR-201905-1066",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-142601"
      }
    ],
    "trust": 0.824516308
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "camera device"
        ],
        "sub_category": "camera",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      }
    ]
  },
  "last_update_date": "2025-01-30T20:44:51.193000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.dlink.com/en/consumer"
      },
      {
        "title": "CVE-2019-10999",
        "trust": 0.1,
        "url": "https://github.com/qjh2333/CVE-2019-10999 "
      },
      {
        "title": "PoC-in-GitHub",
        "trust": 0.1,
        "url": "https://github.com/developer3000S/PoC-in-GitHub "
      },
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/khulnasoft-lab/awesome-security "
      },
      {
        "title": "PoC-in-GitHub",
        "trust": 0.1,
        "url": "https://github.com/hectorgie/PoC-in-GitHub "
      },
      {
        "title": "CVE-POC",
        "trust": 0.1,
        "url": "https://github.com/0xT11/CVE-POC "
      },
      {
        "title": "PoC-in-GitHub",
        "trust": 0.1,
        "url": "https://github.com/nomi-sec/PoC-in-GitHub "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2019-10999"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004361"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-142601"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004361"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10999"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://github.com/fuzzywalls/cve-2019-10999"
      },
      {
        "trust": 1.8,
        "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=sap10131"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-10999"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10999"
      },
      {
        "trust": 0.1,
        "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/qjh2333/cve-2019-10999"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/nomi-sec/poc-in-github"
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-142601"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-10999"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004361"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-138"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10999"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "VULHUB",
        "id": "VHN-142601"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-10999"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004361"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-138"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-10999"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-142601"
      },
      {
        "date": "2019-05-06T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-10999"
      },
      {
        "date": "2019-05-31T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004361"
      },
      {
        "date": "2019-05-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-138"
      },
      {
        "date": "2019-05-06T20:29:01.210000",
        "db": "NVD",
        "id": "CVE-2019-10999"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-142601"
      },
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-10999"
      },
      {
        "date": "2019-05-31T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004361"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-138"
      },
      {
        "date": "2024-11-21T04:20:19.520000",
        "db": "NVD",
        "id": "CVE-2019-10999"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-138"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  D-Link DCS series Product  Wi-Fi camera Buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004361"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-138"
      }
    ],
    "trust": 0.6
  }
}

VAR-201805-0206

Vulnerability from variot - Updated: 2025-01-30 19:36

On D-Link DCS-5009 devices with firmware 1.08.11 and earlier, DCS-5010 devices with firmware 1.14.09 and earlier, and DCS-5020L devices with firmware before 1.15.01, command injection in alphapd (binary responsible for running the camera's web server) allows remote authenticated attackers to execute code through sanitized /setSystemAdmin user input in the AdminID field being passed directly to a call to system. D-Link DCS-5009 , DCS-5010 ,and DCS-5020L The device firmware contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The D-Link DCS-5009, DCS-5010 and DCS-5020L are all different types of network camera products from D-Link. Alphapd is one of the web servers. A remote code execution vulnerability exists in D-LinkDCS-5009 with firmware version 1.08.11 and earlier, DCS-5010 with firmware version 1.14.09 and earlier, and alphapd in DCS-5020L with firmware prior to 1.15.01

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201805-0206",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dcs-5020l",
        "scope": "lt",
        "trust": 1.4,
        "vendor": "d link",
        "version": "1.15.01"
      },
      {
        "model": "dcs-5020l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.14.09"
      },
      {
        "model": "dcs-5009",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.08.11"
      },
      {
        "model": "dcs-5010",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.14.09"
      },
      {
        "model": "dcs-5009l",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "1.08.11"
      },
      {
        "model": "dcs-5010l",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "d link",
        "version": "1.14.09"
      },
      {
        "model": "dcs-5009",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "d link",
        "version": "\u003c=1.08.11"
      },
      {
        "model": "dcs-5010",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "d link",
        "version": "\u003c=1.14.09"
      },
      {
        "model": "dcs-5010",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.14.09"
      },
      {
        "model": "dcs-5009",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.08.11"
      },
      {
        "model": "dcs-5020l",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "d link",
        "version": "1.14.09"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-10226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-013386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-022"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-17020"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5009l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5010l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5020l_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-013386"
      }
    ]
  },
  "cve": "CVE-2017-17020",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CVE-2017-17020",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-10226",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "VHN-108001",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2017-17020",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-17020",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-17020",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-10226",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201805-022",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-108001",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2017-17020",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-10226"
      },
      {
        "db": "VULHUB",
        "id": "VHN-108001"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-17020"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-013386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-022"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-17020"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "On D-Link DCS-5009 devices with firmware 1.08.11 and earlier, DCS-5010 devices with firmware 1.14.09 and earlier, and DCS-5020L devices with firmware before 1.15.01, command injection in alphapd (binary responsible for running the camera\u0027s web server) allows remote authenticated attackers to execute code through sanitized /setSystemAdmin user input in the AdminID field being passed directly to a call to system. D-Link DCS-5009 , DCS-5010 ,and DCS-5020L The device firmware contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The D-Link DCS-5009, DCS-5010 and DCS-5020L are all different types of network camera products from D-Link. Alphapd is one of the web servers. A remote code execution vulnerability exists in D-LinkDCS-5009 with firmware version 1.08.11 and earlier, DCS-5010 with firmware version 1.14.09 and earlier, and alphapd in DCS-5020L with firmware prior to 1.15.01",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-17020"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-013386"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-10226"
      },
      {
        "db": "VULHUB",
        "id": "VHN-108001"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-17020"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-17020",
        "trust": 3.3
      },
      {
        "db": "DLINK",
        "id": "SAP10084",
        "trust": 2.4
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-013386",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-022",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-10226",
        "trust": 0.6
      },
      {
        "db": "OTHER",
        "id": "NONE",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-108001",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-17020",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-10226"
      },
      {
        "db": "VULHUB",
        "id": "VHN-108001"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-17020"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-013386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-022"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-17020"
      }
    ]
  },
  "id": "VAR-201805-0206",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-10226"
      },
      {
        "db": "VULHUB",
        "id": "VHN-108001"
      }
    ],
    "trust": 1.4565656666666666
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "camera device"
        ],
        "sub_category": "camera",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-10226"
      }
    ]
  },
  "last_update_date": "2025-01-30T19:36:35.033000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "DCS-5020L/5010L/5009L :: CVE-2017-17020 Authenticated RCE vulnerability",
        "trust": 0.8,
        "url": "http://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10084"
      },
      {
        "title": "Patch for D-LinkDCS-5009, DCS-5010, and DCS-5020L Remote Code Execution Vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/130047"
      },
      {
        "title": "D-Link DCS-5009 , DCS-5010  and DCS-5020L Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=79767"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-10226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-013386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-022"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-77",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-108001"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-013386"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-17020"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "http://supportannouncement.us.dlink.com/announcement/publication.aspx?name=sap10084"
      },
      {
        "trust": 1.8,
        "url": "https://www.fidusinfosec.com/dlink-dcs-5030l-remote-code-execution-cve-2017-17020/"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-17020"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-17020"
      },
      {
        "trust": 0.1,
        "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/78.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/142922"
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-10226"
      },
      {
        "db": "VULHUB",
        "id": "VHN-108001"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-17020"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-013386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-022"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-17020"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-10226"
      },
      {
        "db": "VULHUB",
        "id": "VHN-108001"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-17020"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-013386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-022"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-17020"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-05-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-10226"
      },
      {
        "date": "2018-05-01T00:00:00",
        "db": "VULHUB",
        "id": "VHN-108001"
      },
      {
        "date": "2018-05-01T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-17020"
      },
      {
        "date": "2018-07-02T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-013386"
      },
      {
        "date": "2018-05-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201805-022"
      },
      {
        "date": "2018-05-01T16:29:00.210000",
        "db": "NVD",
        "id": "CVE-2017-17020"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-05-24T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-10226"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-108001"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-17020"
      },
      {
        "date": "2018-07-02T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-013386"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201805-022"
      },
      {
        "date": "2024-11-21T03:17:21.780000",
        "db": "NVD",
        "id": "CVE-2017-17020"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-022"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  D-Link Command injection vulnerability in product firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-013386"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "operating system commend injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-022"
      }
    ],
    "trust": 0.6
  }
}

VAR-201812-0065

Vulnerability from variot - Updated: 2025-01-30 19:33

D-Link DCS series Wi-Fi cameras expose sensitive information regarding the device configuration. The affected devices include many of DCS series, such as: DCS-936L, DCS-942L, DCS-8000LH, DCS-942LB1, DCS-5222L, DCS-825L, DCS-2630L, DCS-820L, DCS-855L, DCS-2121, DCS-5222LB1, DCS-5020L, and many more. There are many affected firmware versions starting from 1.00 and above. The configuration file can be accessed remotely through: /common/info.cgi, with no authentication. The configuration file include the following fields: model, product, brand, version, build, hw_version, nipca version, device name, location, MAC address, IP address, gateway IP address, wireless status, input/output settings, speaker, and sensor settings. / Output settings, speaker and sensor settings information, etc. D-Link DCS-936L, etc. The following products are affected: D-Link DCS-936L; DCS-942L; DCS-8000LH; DCS-942LB1; 5222LB1; DCS-5020L, etc

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0065",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "dcs-936l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-942l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-8000lh",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-942lb1",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5222l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-825l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-2630l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-820l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-855l",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-2121",
        "scope": null,
        "trust": 1.4,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-930l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00"
      },
      {
        "model": "dcs-5030l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00"
      },
      {
        "model": "dcs-933l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00"
      },
      {
        "model": "dcs-5222l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-936l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-825l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-2630l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-942lb1",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-5222lb1",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-8100lh",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-932l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00"
      },
      {
        "model": "dcs-2102",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-942l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00"
      },
      {
        "model": "dcs-5020l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dlink",
        "version": "1.00"
      },
      {
        "model": "dcs-820l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-2121",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-8000lh",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-855l",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "d link",
        "version": "1.00"
      },
      {
        "model": "dcs-5222lb1",
        "scope": null,
        "trust": 0.6,
        "vendor": "d link",
        "version": null
      },
      {
        "model": "dcs-5020l",
        "scope": null,
        "trust": 0.6,
        "vendor": "d link",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "dcs 942lb1",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 936l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 2121",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5222lb1",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5020l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 930l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 8100lh",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 932l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 2102",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 933l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5030l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 942l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 8000lh",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 5222l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 825l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 2630l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 820l",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dcs 855l",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-2121_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-2630l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-5222l__firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-8000lh_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-820l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-825l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-855l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-936l",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-942l_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:d-link:dcs-942lb1_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      }
    ]
  },
  "cve": "CVE-2018-18441",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18441",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-26797",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "7d831f62-463f-11e9-8196-000c29342cb1",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-129001",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18441",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18441",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18441",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-26797",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201812-968",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "7d831f62-463f-11e9-8196-000c29342cb1",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129001",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "D-Link DCS series Wi-Fi cameras expose sensitive information regarding the device configuration. The affected devices include many of DCS series, such as: DCS-936L, DCS-942L, DCS-8000LH, DCS-942LB1, DCS-5222L, DCS-825L, DCS-2630L, DCS-820L, DCS-855L, DCS-2121, DCS-5222LB1, DCS-5020L, and many more. There are many affected firmware versions starting from 1.00 and above. The configuration file can be accessed remotely through: \u003cCamera-IP\u003e/common/info.cgi, with no authentication. The configuration file include the following fields: model, product, brand, version, build, hw_version, nipca version, device name, location, MAC address, IP address, gateway IP address, wireless status, input/output settings, speaker, and sensor settings. / Output settings, speaker and sensor settings information, etc. D-Link DCS-936L, etc. The following products are affected: D-Link DCS-936L; DCS-942L; DCS-8000LH; DCS-942LB1; 5222LB1; DCS-5020L, etc",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      }
    ],
    "trust": 2.43
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18441",
        "trust": 3.4
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "7D831F62-463F-11E9-8196-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "OTHER",
        "id": "NONE",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "id": "VAR-201812-0065",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      }
    ],
    "trust": 1.6519531171428572
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      },
      {
        "category": [
          "camera device"
        ],
        "sub_category": "camera",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      }
    ]
  },
  "last_update_date": "2025-01-30T19:33:35.858000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.dlink.com/en/consumer"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-200",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://dojo.bullguard.com/dojo-by-bullguard/blog/i-got-my-eyeon-you-security-vulnerabilities-in-baby-monitor/"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18441"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18441"
      },
      {
        "trust": 0.1,
        "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-12-28T00:00:00",
        "db": "IVD",
        "id": "7d831f62-463f-11e9-8196-000c29342cb1"
      },
      {
        "date": "2018-12-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "date": "2018-12-20T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "date": "2019-03-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "date": "2018-12-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      },
      {
        "date": "2018-12-20T23:29:00.707000",
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-26797"
      },
      {
        "date": "2019-02-13T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129001"
      },
      {
        "date": "2019-03-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      },
      {
        "date": "2023-04-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      },
      {
        "date": "2024-11-21T03:55:56.640000",
        "db": "NVD",
        "id": "CVE-2018-18441"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  D-Link DCS series Product  Wi-Fi Information disclosure vulnerability in cameras",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014473"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "information disclosure",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201812-968"
      }
    ],
    "trust": 0.6
  }
}