Search criteria

14 vulnerabilities found for cubeone_firmware by ismartalarm

CVE-2018-16224 (GCVE-0-2018-16224)

Vulnerability from nvd – Published: 2018-11-20 19:00 – Updated: 2024-08-05 10:17
VLAI?
Summary
Incorrect access control for the diagnostic files of the iSmartAlarm Cube One through 2.2.4.10 allows an attacker to retrieve them via a specifically crafted TCP request to port 12345 and 22306, and access sensitive information from the device.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:17:38.387Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20181102 [CVE-2018-16222 to 16225] Multiple Vulnerabilities in QBee and iSmartAlarm Products",
            "tags": [
              "mailing-list",
              "x_refsource_FULLDISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2018/Nov/2"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/150165/QBee-Camera-iSmartAlarm-Credential-Disclosure.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-11-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Incorrect access control for the diagnostic files of the iSmartAlarm Cube One through 2.2.4.10 allows an attacker to retrieve them via a specifically crafted TCP request to port 12345 and 22306, and access sensitive information from the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-11-20T18:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "20181102 [CVE-2018-16222 to 16225] Multiple Vulnerabilities in QBee and iSmartAlarm Products",
          "tags": [
            "mailing-list",
            "x_refsource_FULLDISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2018/Nov/2"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/150165/QBee-Camera-iSmartAlarm-Credential-Disclosure.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-16224",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Incorrect access control for the diagnostic files of the iSmartAlarm Cube One through 2.2.4.10 allows an attacker to retrieve them via a specifically crafted TCP request to port 12345 and 22306, and access sensitive information from the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20181102 [CVE-2018-16222 to 16225] Multiple Vulnerabilities in QBee and iSmartAlarm Products",
              "refsource": "FULLDISC",
              "url": "http://seclists.org/fulldisclosure/2018/Nov/2"
            },
            {
              "name": "http://packetstormsecurity.com/files/150165/QBee-Camera-iSmartAlarm-Credential-Disclosure.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/150165/QBee-Camera-iSmartAlarm-Credential-Disclosure.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-16224",
    "datePublished": "2018-11-20T19:00:00",
    "dateReserved": "2018-08-30T00:00:00",
    "dateUpdated": "2024-08-05T10:17:38.387Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-13664 (GCVE-0-2017-13664)

Vulnerability from nvd – Published: 2017-12-01 17:00 – Updated: 2024-08-05 19:05
VLAI?
Summary
Password file exposure in firmware in iSmartAlarm CubeOne version 2.2.4.8 and earlier allows attackers to execute arbitrary commands with administrative privileges by retrieving credentials from this file.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:05:19.158Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-11-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Password file exposure in firmware in iSmartAlarm CubeOne version 2.2.4.8 and earlier allows attackers to execute arbitrary commands with administrative privileges by retrieving credentials from this file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-01T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-13664",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Password file exposure in firmware in iSmartAlarm CubeOne version 2.2.4.8 and earlier allows attackers to execute arbitrary commands with administrative privileges by retrieving credentials from this file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/",
              "refsource": "MISC",
              "url": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-13664",
    "datePublished": "2017-12-01T17:00:00",
    "dateReserved": "2017-08-24T00:00:00",
    "dateUpdated": "2024-08-05T19:05:19.158Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-13663 (GCVE-0-2017-13663)

Vulnerability from nvd – Published: 2017-12-01 17:00 – Updated: 2024-08-05 19:05
VLAI?
Summary
Encryption key exposure in firmware in iSmartAlarm CubeOne version 2.2.4.8 and earlier allows attackers to decrypt log files via an exposed key.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:05:19.041Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-11-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Encryption key exposure in firmware in iSmartAlarm CubeOne version 2.2.4.8 and earlier allows attackers to decrypt log files via an exposed key."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-01T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-13663",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Encryption key exposure in firmware in iSmartAlarm CubeOne version 2.2.4.8 and earlier allows attackers to decrypt log files via an exposed key."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/",
              "refsource": "MISC",
              "url": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-13663",
    "datePublished": "2017-12-01T17:00:00",
    "dateReserved": "2017-08-24T00:00:00",
    "dateUpdated": "2024-08-05T19:05:19.041Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7730 (GCVE-0-2017-7730)

Vulnerability from nvd – Published: 2017-07-11 17:00 – Updated: 2024-08-05 16:12
VLAI?
Summary
iSmartAlarm cube devices allow Denial of Service. Sending a SYN flood on port 12345 will freeze the "cube" and it will stop responding.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:12:28.244Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "iSmartAlarm cube devices allow Denial of Service. Sending a SYN flood on port 12345 will freeze the \"cube\" and it will stop responding."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-11T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-7730",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "iSmartAlarm cube devices allow Denial of Service. Sending a SYN flood on port 12345 will freeze the \"cube\" and it will stop responding."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/",
              "refsource": "MISC",
              "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-7730",
    "datePublished": "2017-07-11T17:00:00",
    "dateReserved": "2017-04-12T00:00:00",
    "dateUpdated": "2024-08-05T16:12:28.244Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7729 (GCVE-0-2017-7729)

Vulnerability from nvd – Published: 2017-07-11 17:00 – Updated: 2024-08-05 16:12
VLAI?
Summary
On iSmartAlarm cube devices, there is Incorrect Access Control because a "new key" is transmitted in cleartext.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:12:28.409Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "On iSmartAlarm cube devices, there is Incorrect Access Control because a \"new key\" is transmitted in cleartext."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-11T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-7729",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "On iSmartAlarm cube devices, there is Incorrect Access Control because a \"new key\" is transmitted in cleartext."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/",
              "refsource": "MISC",
              "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-7729",
    "datePublished": "2017-07-11T17:00:00",
    "dateReserved": "2017-04-12T00:00:00",
    "dateUpdated": "2024-08-05T16:12:28.409Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7728 (GCVE-0-2017-7728)

Vulnerability from nvd – Published: 2017-07-11 17:00 – Updated: 2024-08-05 16:12
VLAI?
Summary
On iSmartAlarm cube devices, there is authentication bypass leading to remote execution of commands (e.g., setting the alarm on/off), related to incorrect cryptography.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:12:28.336Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "On iSmartAlarm cube devices, there is authentication bypass leading to remote execution of commands (e.g., setting the alarm on/off), related to incorrect cryptography."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-11T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-7728",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "On iSmartAlarm cube devices, there is authentication bypass leading to remote execution of commands (e.g., setting the alarm on/off), related to incorrect cryptography."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/",
              "refsource": "MISC",
              "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-7728",
    "datePublished": "2017-07-11T17:00:00",
    "dateReserved": "2017-04-12T00:00:00",
    "dateUpdated": "2024-08-05T16:12:28.336Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7726 (GCVE-0-2017-7726)

Vulnerability from nvd – Published: 2017-07-11 17:00 – Updated: 2024-08-05 16:12
VLAI?
Summary
iSmartAlarm cube devices have an SSL Certificate Validation Vulnerability.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:12:28.277Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "iSmartAlarm cube devices have an SSL Certificate Validation Vulnerability."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-11T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-7726",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "iSmartAlarm cube devices have an SSL Certificate Validation Vulnerability."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/",
              "refsource": "MISC",
              "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-7726",
    "datePublished": "2017-07-11T17:00:00",
    "dateReserved": "2017-04-12T00:00:00",
    "dateUpdated": "2024-08-05T16:12:28.277Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16224 (GCVE-0-2018-16224)

Vulnerability from cvelistv5 – Published: 2018-11-20 19:00 – Updated: 2024-08-05 10:17
VLAI?
Summary
Incorrect access control for the diagnostic files of the iSmartAlarm Cube One through 2.2.4.10 allows an attacker to retrieve them via a specifically crafted TCP request to port 12345 and 22306, and access sensitive information from the device.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:17:38.387Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20181102 [CVE-2018-16222 to 16225] Multiple Vulnerabilities in QBee and iSmartAlarm Products",
            "tags": [
              "mailing-list",
              "x_refsource_FULLDISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2018/Nov/2"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/150165/QBee-Camera-iSmartAlarm-Credential-Disclosure.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-11-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Incorrect access control for the diagnostic files of the iSmartAlarm Cube One through 2.2.4.10 allows an attacker to retrieve them via a specifically crafted TCP request to port 12345 and 22306, and access sensitive information from the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-11-20T18:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "20181102 [CVE-2018-16222 to 16225] Multiple Vulnerabilities in QBee and iSmartAlarm Products",
          "tags": [
            "mailing-list",
            "x_refsource_FULLDISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2018/Nov/2"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/150165/QBee-Camera-iSmartAlarm-Credential-Disclosure.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-16224",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Incorrect access control for the diagnostic files of the iSmartAlarm Cube One through 2.2.4.10 allows an attacker to retrieve them via a specifically crafted TCP request to port 12345 and 22306, and access sensitive information from the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20181102 [CVE-2018-16222 to 16225] Multiple Vulnerabilities in QBee and iSmartAlarm Products",
              "refsource": "FULLDISC",
              "url": "http://seclists.org/fulldisclosure/2018/Nov/2"
            },
            {
              "name": "http://packetstormsecurity.com/files/150165/QBee-Camera-iSmartAlarm-Credential-Disclosure.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/150165/QBee-Camera-iSmartAlarm-Credential-Disclosure.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-16224",
    "datePublished": "2018-11-20T19:00:00",
    "dateReserved": "2018-08-30T00:00:00",
    "dateUpdated": "2024-08-05T10:17:38.387Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-13663 (GCVE-0-2017-13663)

Vulnerability from cvelistv5 – Published: 2017-12-01 17:00 – Updated: 2024-08-05 19:05
VLAI?
Summary
Encryption key exposure in firmware in iSmartAlarm CubeOne version 2.2.4.8 and earlier allows attackers to decrypt log files via an exposed key.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:05:19.041Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-11-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Encryption key exposure in firmware in iSmartAlarm CubeOne version 2.2.4.8 and earlier allows attackers to decrypt log files via an exposed key."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-01T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-13663",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Encryption key exposure in firmware in iSmartAlarm CubeOne version 2.2.4.8 and earlier allows attackers to decrypt log files via an exposed key."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/",
              "refsource": "MISC",
              "url": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-13663",
    "datePublished": "2017-12-01T17:00:00",
    "dateReserved": "2017-08-24T00:00:00",
    "dateUpdated": "2024-08-05T19:05:19.041Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-13664 (GCVE-0-2017-13664)

Vulnerability from cvelistv5 – Published: 2017-12-01 17:00 – Updated: 2024-08-05 19:05
VLAI?
Summary
Password file exposure in firmware in iSmartAlarm CubeOne version 2.2.4.8 and earlier allows attackers to execute arbitrary commands with administrative privileges by retrieving credentials from this file.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:05:19.158Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-11-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Password file exposure in firmware in iSmartAlarm CubeOne version 2.2.4.8 and earlier allows attackers to execute arbitrary commands with administrative privileges by retrieving credentials from this file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-01T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-13664",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Password file exposure in firmware in iSmartAlarm CubeOne version 2.2.4.8 and earlier allows attackers to execute arbitrary commands with administrative privileges by retrieving credentials from this file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/",
              "refsource": "MISC",
              "url": "https://poppopretn.com/2017/11/30/public-disclosure-firmware-vulnerabilities-in-ismartalarm-cubeone/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-13664",
    "datePublished": "2017-12-01T17:00:00",
    "dateReserved": "2017-08-24T00:00:00",
    "dateUpdated": "2024-08-05T19:05:19.158Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7728 (GCVE-0-2017-7728)

Vulnerability from cvelistv5 – Published: 2017-07-11 17:00 – Updated: 2024-08-05 16:12
VLAI?
Summary
On iSmartAlarm cube devices, there is authentication bypass leading to remote execution of commands (e.g., setting the alarm on/off), related to incorrect cryptography.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:12:28.336Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "On iSmartAlarm cube devices, there is authentication bypass leading to remote execution of commands (e.g., setting the alarm on/off), related to incorrect cryptography."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-11T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-7728",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "On iSmartAlarm cube devices, there is authentication bypass leading to remote execution of commands (e.g., setting the alarm on/off), related to incorrect cryptography."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/",
              "refsource": "MISC",
              "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-7728",
    "datePublished": "2017-07-11T17:00:00",
    "dateReserved": "2017-04-12T00:00:00",
    "dateUpdated": "2024-08-05T16:12:28.336Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7726 (GCVE-0-2017-7726)

Vulnerability from cvelistv5 – Published: 2017-07-11 17:00 – Updated: 2024-08-05 16:12
VLAI?
Summary
iSmartAlarm cube devices have an SSL Certificate Validation Vulnerability.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:12:28.277Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "iSmartAlarm cube devices have an SSL Certificate Validation Vulnerability."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-11T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-7726",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "iSmartAlarm cube devices have an SSL Certificate Validation Vulnerability."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/",
              "refsource": "MISC",
              "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-7726",
    "datePublished": "2017-07-11T17:00:00",
    "dateReserved": "2017-04-12T00:00:00",
    "dateUpdated": "2024-08-05T16:12:28.277Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7729 (GCVE-0-2017-7729)

Vulnerability from cvelistv5 – Published: 2017-07-11 17:00 – Updated: 2024-08-05 16:12
VLAI?
Summary
On iSmartAlarm cube devices, there is Incorrect Access Control because a "new key" is transmitted in cleartext.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:12:28.409Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "On iSmartAlarm cube devices, there is Incorrect Access Control because a \"new key\" is transmitted in cleartext."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-11T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-7729",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "On iSmartAlarm cube devices, there is Incorrect Access Control because a \"new key\" is transmitted in cleartext."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/",
              "refsource": "MISC",
              "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-7729",
    "datePublished": "2017-07-11T17:00:00",
    "dateReserved": "2017-04-12T00:00:00",
    "dateUpdated": "2024-08-05T16:12:28.409Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7730 (GCVE-0-2017-7730)

Vulnerability from cvelistv5 – Published: 2017-07-11 17:00 – Updated: 2024-08-05 16:12
VLAI?
Summary
iSmartAlarm cube devices allow Denial of Service. Sending a SYN flood on port 12345 will freeze the "cube" and it will stop responding.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:12:28.244Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "iSmartAlarm cube devices allow Denial of Service. Sending a SYN flood on port 12345 will freeze the \"cube\" and it will stop responding."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-11T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-7730",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "iSmartAlarm cube devices allow Denial of Service. Sending a SYN flood on port 12345 will freeze the \"cube\" and it will stop responding."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/",
              "refsource": "MISC",
              "url": "http://dojo.bullguard.com/blog/burglar-hacker-when-a-physical-security-is-compromised-by-iot-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-7730",
    "datePublished": "2017-07-11T17:00:00",
    "dateReserved": "2017-04-12T00:00:00",
    "dateUpdated": "2024-08-05T16:12:28.244Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",