Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow. Texas Instruments Microcontroller CC2640 and CC2650 Used in the firmware of BLE-Stack Contains a buffer overflow vulnerability. Insufficient memory operation range (CWE-119) - CVE-2018-16986 Texas Instruments Microcontroller CC2640 and CC2650 Used in the firmware of BLE-Stack Is BLE advertising There is a problem with packet processing. In the chip ROM Included in the image llGetAdvChanPDU Function received advertising Parses the packet and copies its contents to another buffer. If the received data exceeds a certain length, BLE-Stack Included in applications that run on halAssertHandler It is a mechanism to call a function and continue processing. The following chips are vulnerable: CC2640 (non-R2) with BLE-STACK version 2.2.1 or prior CC2650 with BLE-STACK version 2.2.1 or prior CC2640R2F with SimpleLink CC2640R2 SDK version 1.00.00.22 (BLE-STACK 3.0.0) CC1350 with SimpleLink CC13x0 SDK version 2.20.00.38 (BLE-STACK 2.3.3) or prior

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201811-0299",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ble-stack",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "ti",
        "version": "3.0.0"
      },
      {
        "model": "ble-stack",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "ti",
        "version": "2.2.1"
      },
      {
        "model": "ble-stack",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "ti",
        "version": "2.3.3"
      },
      {
        "model": null,
        "scope": null,
        "trust": 0.8,
        "vendor": "aruba",
        "version": null
      },
      {
        "model": null,
        "scope": null,
        "trust": 0.8,
        "vendor": "cisco",
        "version": null
      },
      {
        "model": null,
        "scope": null,
        "trust": 0.8,
        "vendor": "texas instruments",
        "version": null
      },
      {
        "model": "ble-stack",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "texas instrument",
        "version": "v2.2.2 earlier"
      },
      {
        "model": "simplelink cc2640r2 sdk",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "1.00.00.22"
      },
      {
        "model": "simplelink cc13x0 sdk",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "2.20.00.38"
      },
      {
        "model": "cc2650",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "0"
      },
      {
        "model": "cc2640r2f",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "0"
      },
      {
        "model": "cc2640",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "0"
      },
      {
        "model": "cc1350",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "0"
      },
      {
        "model": "ble-stack",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "3.0"
      },
      {
        "model": "ble-stack",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "2.3.3"
      },
      {
        "model": "ble-stack",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "2.2.1"
      },
      {
        "model": "ble-stack",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "2.1.1"
      },
      {
        "model": "ble-stack",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "2.1"
      },
      {
        "model": "ble-stack",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "2.0"
      },
      {
        "model": "ble-stack",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "1.4.1"
      },
      {
        "model": "ble-stack",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "ti",
        "version": "1.4"
      },
      {
        "model": "meraki mr74",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cisco",
        "version": "0"
      },
      {
        "model": "meraki mr53e",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cisco",
        "version": "0"
      },
      {
        "model": "meraki mr42e",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cisco",
        "version": "0"
      },
      {
        "model": "meraki mr33",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cisco",
        "version": "0"
      },
      {
        "model": "meraki mr30h",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cisco",
        "version": "0"
      },
      {
        "model": "aironet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cisco",
        "version": "4800"
      },
      {
        "model": "aironet 1815m",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cisco",
        "version": "0"
      },
      {
        "model": "aironet 1815i",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cisco",
        "version": "0"
      },
      {
        "model": "aironet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cisco",
        "version": "18100"
      },
      {
        "model": "aironet 1800i",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cisco",
        "version": "0"
      },
      {
        "model": "aironet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "cisco",
        "version": "15400"
      },
      {
        "model": "simplelink cc2640r2 sdk",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "ti",
        "version": "1.30.00.25"
      },
      {
        "model": "simplelink cc13x0 sdk",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "ti",
        "version": "2.30.00.20"
      },
      {
        "model": "ble-stack",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "ti",
        "version": "3.0.1"
      },
      {
        "model": "ble-stack",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "ti",
        "version": "2.3.4"
      },
      {
        "model": "ble-stack",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "ti",
        "version": "2.2.2"
      }
    ],
    "sources": [
      {
        "db": "CERT/CC",
        "id": "VU#317277"
      },
      {
        "db": "BID",
        "id": "105812"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008978"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16986"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:texas_instrument:ukcms:ble-stack",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008978"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Cisco would like to thank Ben Seri, for finding and reporting this vulnerability., VP of Research at Armis",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-025"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2018-16986",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CVE-2018-16986",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2018-16986",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-16986",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201811-025",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-025"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16986"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow. Texas Instruments Microcontroller CC2640 and CC2650 Used in the firmware of BLE-Stack Contains a buffer overflow vulnerability. Insufficient memory operation range (CWE-119) - CVE-2018-16986 Texas Instruments Microcontroller CC2640 and CC2650 Used in the firmware of BLE-Stack Is BLE advertising There is a problem with packet processing. In the chip ROM Included in the image llGetAdvChanPDU Function received advertising Parses the packet and copies its contents to another buffer. If the received data exceeds a certain length, BLE-Stack Included in applications that run on halAssertHandler It is a mechanism to call a function and continue processing. \nThe following chips are vulnerable:\nCC2640 (non-R2) with BLE-STACK version 2.2.1 or prior\nCC2650 with BLE-STACK version 2.2.1 or prior\nCC2640R2F with SimpleLink CC2640R2 SDK version 1.00.00.22 (BLE-STACK 3.0.0)\nCC1350 with SimpleLink CC13x0 SDK version 2.20.00.38 (BLE-STACK 2.3.3) or prior",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-16986"
      },
      {
        "db": "CERT/CC",
        "id": "VU#317277"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008978"
      },
      {
        "db": "BID",
        "id": "105812"
      }
    ],
    "trust": 2.61
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "CERT/CC",
        "id": "VU#317277",
        "trust": 3.5
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16986",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "105812",
        "trust": 1.9
      },
      {
        "db": "SECTRACK",
        "id": "1042018",
        "trust": 1.6
      },
      {
        "db": "JVN",
        "id": "JVNVU98767431",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008978",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.1300",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-025",
        "trust": 0.6
      },
      {
        "db": "OTHER",
        "id": "NONE",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CERT/CC",
        "id": "VU#317277"
      },
      {
        "db": "BID",
        "id": "105812"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008978"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-025"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16986"
      }
    ]
  },
  "id": "VAR-201811-0299",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "OTHER",
        "id": null
      }
    ],
    "trust": 0.01
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "network device"
        ],
        "sub_category": "bluetooth device",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      }
    ]
  },
  "last_update_date": "2025-01-30T21:06:31.758000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": " Aruba BLE Radio Firmware Vulnerability  ",
        "trust": 0.8,
        "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2018-006.txt"
      },
      {
        "title": "BLE-Stack 2.2.2",
        "trust": 0.8,
        "url": "http://software-dl.ti.com/lprf/ble_stack/exports/release_notes_BLE_Stack_2_2_2.html"
      },
      {
        "title": "Texas Instruments CC2640  and CC2650 Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=86570"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008978"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-025"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008978"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16986"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.5,
        "url": "https://armis.com/bleedingbit/"
      },
      {
        "trust": 2.7,
        "url": "https://www.kb.cert.org/vuls/id/317277"
      },
      {
        "trust": 1.9,
        "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20181101-ap"
      },
      {
        "trust": 1.6,
        "url": "http://www.securityfocus.com/bid/105812"
      },
      {
        "trust": 1.6,
        "url": "http://www.securitytracker.com/id/1042018"
      },
      {
        "trust": 1.6,
        "url": "http://e2e.ti.com/support/wireless-connectivity/bluetooth/f/538/t/742827"
      },
      {
        "trust": 1.1,
        "url": "http://software-dl.ti.com/lprf/ble_stack/exports/release_notes_ble_stack_2_2_2.html"
      },
      {
        "trust": 0.8,
        "url": "https://cwe.mitre.org/data/definitions/119.html"
      },
      {
        "trust": 0.8,
        "url": "https://www.arubanetworks.com/assets/alert/aruba-psa-2018-006.txt"
      },
      {
        "trust": 0.8,
        "url": "http://dev.ti.com/tirex/content/simplelink_cc2640r2_sdk_2_30_00_28/docs/blestack/ble_user_guide/html/ble3-stack-oad/index-ble3-cc2640.html"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-16986"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98767431/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-16986"
      },
      {
        "trust": 0.6,
        "url": "https://fortiguard.com/psirt/fg-ir-18-356"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/79126"
      },
      {
        "trust": 0.3,
        "url": "http://www.ti.com/"
      },
      {
        "trust": 0.1,
        "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CERT/CC",
        "id": "VU#317277"
      },
      {
        "db": "BID",
        "id": "105812"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008978"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-025"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16986"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "CERT/CC",
        "id": "VU#317277"
      },
      {
        "db": "BID",
        "id": "105812"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008978"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-025"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16986"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-11-01T00:00:00",
        "db": "CERT/CC",
        "id": "VU#317277"
      },
      {
        "date": "2018-11-01T00:00:00",
        "db": "BID",
        "id": "105812"
      },
      {
        "date": "2018-11-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-008978"
      },
      {
        "date": "2018-11-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201811-025"
      },
      {
        "date": "2018-11-06T15:29:00.327000",
        "db": "NVD",
        "id": "CVE-2018-16986"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-07T00:00:00",
        "db": "CERT/CC",
        "id": "VU#317277"
      },
      {
        "date": "2018-11-01T00:00:00",
        "db": "BID",
        "id": "105812"
      },
      {
        "date": "2019-07-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-008978"
      },
      {
        "date": "2021-07-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201811-025"
      },
      {
        "date": "2024-11-21T03:53:39.360000",
        "db": "NVD",
        "id": "CVE-2018-16986"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-025"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Texas Instruments CC2640 and CC2650 microcontrollers vulnerable to heap overflow and insecure update",
    "sources": [
      {
        "db": "CERT/CC",
        "id": "VU#317277"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-025"
      }
    ],
    "trust": 0.6
  }
}

CVE-2019-19193 (GCVE-0-2019-19193)

Vulnerability from nvd – Published: 2020-02-10 20:33 – Updated: 2024-08-05 02:09
VLAI?
Summary
The Bluetooth Low Energy peripheral implementation on Texas Instruments SIMPLELINK-CC2640R2-SDK through 3.30.00.20 and BLE-STACK through 1.5.0 before Q4 2019 for CC2640R2 and CC2540/1 devices does not properly restrict the advertisement connection request packet on reception, allowing attackers in radio range to cause a denial of service (crash) via a crafted packet.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:09:39.441Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.ti.com/tool/BLE-STACK"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://asset-group.github.io/disclosures/sweyntooth/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Bluetooth Low Energy peripheral implementation on Texas Instruments SIMPLELINK-CC2640R2-SDK through 3.30.00.20 and BLE-STACK through 1.5.0 before Q4 2019 for CC2640R2 and CC2540/1 devices does not properly restrict the advertisement connection request packet on reception, allowing attackers in radio range to cause a denial of service (crash) via a crafted packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-10T20:33:05",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.ti.com/tool/BLE-STACK"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://asset-group.github.io/disclosures/sweyntooth/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2019-19193",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Bluetooth Low Energy peripheral implementation on Texas Instruments SIMPLELINK-CC2640R2-SDK through 3.30.00.20 and BLE-STACK through 1.5.0 before Q4 2019 for CC2640R2 and CC2540/1 devices does not properly restrict the advertisement connection request packet on reception, allowing attackers in radio range to cause a denial of service (crash) via a crafted packet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.ti.com/tool/BLE-STACK",
              "refsource": "MISC",
              "url": "http://www.ti.com/tool/BLE-STACK"
            },
            {
              "name": "https://asset-group.github.io/disclosures/sweyntooth/",
              "refsource": "MISC",
              "url": "https://asset-group.github.io/disclosures/sweyntooth/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2019-19193",
    "datePublished": "2020-02-10T20:33:05",
    "dateReserved": "2019-11-21T00:00:00",
    "dateUpdated": "2024-08-05T02:09:39.441Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16986 (GCVE-0-2018-16986)

Vulnerability from nvd – Published: 2018-11-06 16:00 – Updated: 2024-08-05 10:39
VLAI?
Summary
Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
https://armis.com/bleedingbit/ x_refsource_MISC
http://e2e.ti.com/support/wireless-connectivity/b… x_refsource_CONFIRM
http://www.securitytracker.com/id/1042018 vdb-entryx_refsource_SECTRACK
https://www.kb.cert.org/vuls/id/317277 third-party-advisoryx_refsource_CERT-VN
http://www.securityfocus.com/bid/105812 vdb-entryx_refsource_BID
https://tools.cisco.com/security/center/content/C… vendor-advisoryx_refsource_CISCO
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:39:59.576Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://armis.com/bleedingbit/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://e2e.ti.com/support/wireless-connectivity/bluetooth/f/538/t/742827"
          },
          {
            "name": "1042018",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1042018"
          },
          {
            "name": "VU#317277",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "https://www.kb.cert.org/vuls/id/317277"
          },
          {
            "name": "105812",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105812"
          },
          {
            "name": "20181101 Texas Instruments Bluetooth Low Energy Denial of Service and Remote Code Execution Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20181101-ap"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-11-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-11-07T10:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://armis.com/bleedingbit/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://e2e.ti.com/support/wireless-connectivity/bluetooth/f/538/t/742827"
        },
        {
          "name": "1042018",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1042018"
        },
        {
          "name": "VU#317277",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "https://www.kb.cert.org/vuls/id/317277"
        },
        {
          "name": "105812",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105812"
        },
        {
          "name": "20181101 Texas Instruments Bluetooth Low Energy Denial of Service and Remote Code Execution Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20181101-ap"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-16986",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://armis.com/bleedingbit/",
              "refsource": "MISC",
              "url": "https://armis.com/bleedingbit/"
            },
            {
              "name": "http://e2e.ti.com/support/wireless-connectivity/bluetooth/f/538/t/742827",
              "refsource": "CONFIRM",
              "url": "http://e2e.ti.com/support/wireless-connectivity/bluetooth/f/538/t/742827"
            },
            {
              "name": "1042018",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1042018"
            },
            {
              "name": "VU#317277",
              "refsource": "CERT-VN",
              "url": "https://www.kb.cert.org/vuls/id/317277"
            },
            {
              "name": "105812",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105812"
            },
            {
              "name": "20181101 Texas Instruments Bluetooth Low Energy Denial of Service and Remote Code Execution Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20181101-ap"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-16986",
    "datePublished": "2018-11-06T16:00:00",
    "dateReserved": "2018-09-13T00:00:00",
    "dateUpdated": "2024-08-05T10:39:59.576Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-19193 (GCVE-0-2019-19193)

Vulnerability from cvelistv5 – Published: 2020-02-10 20:33 – Updated: 2024-08-05 02:09
VLAI?
Summary
The Bluetooth Low Energy peripheral implementation on Texas Instruments SIMPLELINK-CC2640R2-SDK through 3.30.00.20 and BLE-STACK through 1.5.0 before Q4 2019 for CC2640R2 and CC2540/1 devices does not properly restrict the advertisement connection request packet on reception, allowing attackers in radio range to cause a denial of service (crash) via a crafted packet.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:09:39.441Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.ti.com/tool/BLE-STACK"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://asset-group.github.io/disclosures/sweyntooth/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Bluetooth Low Energy peripheral implementation on Texas Instruments SIMPLELINK-CC2640R2-SDK through 3.30.00.20 and BLE-STACK through 1.5.0 before Q4 2019 for CC2640R2 and CC2540/1 devices does not properly restrict the advertisement connection request packet on reception, allowing attackers in radio range to cause a denial of service (crash) via a crafted packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-10T20:33:05",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.ti.com/tool/BLE-STACK"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://asset-group.github.io/disclosures/sweyntooth/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2019-19193",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Bluetooth Low Energy peripheral implementation on Texas Instruments SIMPLELINK-CC2640R2-SDK through 3.30.00.20 and BLE-STACK through 1.5.0 before Q4 2019 for CC2640R2 and CC2540/1 devices does not properly restrict the advertisement connection request packet on reception, allowing attackers in radio range to cause a denial of service (crash) via a crafted packet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.ti.com/tool/BLE-STACK",
              "refsource": "MISC",
              "url": "http://www.ti.com/tool/BLE-STACK"
            },
            {
              "name": "https://asset-group.github.io/disclosures/sweyntooth/",
              "refsource": "MISC",
              "url": "https://asset-group.github.io/disclosures/sweyntooth/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2019-19193",
    "datePublished": "2020-02-10T20:33:05",
    "dateReserved": "2019-11-21T00:00:00",
    "dateUpdated": "2024-08-05T02:09:39.441Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16986 (GCVE-0-2018-16986)

Vulnerability from cvelistv5 – Published: 2018-11-06 16:00 – Updated: 2024-08-05 10:39
VLAI?
Summary
Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
https://armis.com/bleedingbit/ x_refsource_MISC
http://e2e.ti.com/support/wireless-connectivity/b… x_refsource_CONFIRM
http://www.securitytracker.com/id/1042018 vdb-entryx_refsource_SECTRACK
https://www.kb.cert.org/vuls/id/317277 third-party-advisoryx_refsource_CERT-VN
http://www.securityfocus.com/bid/105812 vdb-entryx_refsource_BID
https://tools.cisco.com/security/center/content/C… vendor-advisoryx_refsource_CISCO
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:39:59.576Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://armis.com/bleedingbit/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://e2e.ti.com/support/wireless-connectivity/bluetooth/f/538/t/742827"
          },
          {
            "name": "1042018",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1042018"
          },
          {
            "name": "VU#317277",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "https://www.kb.cert.org/vuls/id/317277"
          },
          {
            "name": "105812",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105812"
          },
          {
            "name": "20181101 Texas Instruments Bluetooth Low Energy Denial of Service and Remote Code Execution Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20181101-ap"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-11-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-11-07T10:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://armis.com/bleedingbit/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://e2e.ti.com/support/wireless-connectivity/bluetooth/f/538/t/742827"
        },
        {
          "name": "1042018",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1042018"
        },
        {
          "name": "VU#317277",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "https://www.kb.cert.org/vuls/id/317277"
        },
        {
          "name": "105812",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105812"
        },
        {
          "name": "20181101 Texas Instruments Bluetooth Low Energy Denial of Service and Remote Code Execution Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20181101-ap"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-16986",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://armis.com/bleedingbit/",
              "refsource": "MISC",
              "url": "https://armis.com/bleedingbit/"
            },
            {
              "name": "http://e2e.ti.com/support/wireless-connectivity/bluetooth/f/538/t/742827",
              "refsource": "CONFIRM",
              "url": "http://e2e.ti.com/support/wireless-connectivity/bluetooth/f/538/t/742827"
            },
            {
              "name": "1042018",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1042018"
            },
            {
              "name": "VU#317277",
              "refsource": "CERT-VN",
              "url": "https://www.kb.cert.org/vuls/id/317277"
            },
            {
              "name": "105812",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105812"
            },
            {
              "name": "20181101 Texas Instruments Bluetooth Low Energy Denial of Service and Remote Code Execution Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20181101-ap"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-16986",
    "datePublished": "2018-11-06T16:00:00",
    "dateReserved": "2018-09-13T00:00:00",
    "dateUpdated": "2024-08-05T10:39:59.576Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",