Search criteria
4 vulnerabilities found for arcsight_c1300_appliance by hp
CVE-2011-2779 (GCVE-0-2011-2779)
Vulnerability from nvd – Published: 2011-07-19 21:00 – Updated: 2024-08-06 23:15
VLAI?
Summary
Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 uses world-writable permissions for exported report files, which allows local users to change or delete log data by modifying a file, a different vulnerability than CVE-2011-0770.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:15:30.796Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "arcsight-windows-event-priv-escalation(68855)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68855"
},
{
"name": "VU#122054",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/122054"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2011-07-15T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 uses world-writable permissions for exported report files, which allows local users to change or delete log data by modifying a file, a different vulnerability than CVE-2011-0770."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-28T12:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "arcsight-windows-event-priv-escalation(68855)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68855"
},
{
"name": "VU#122054",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/122054"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2011-2779",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 uses world-writable permissions for exported report files, which allows local users to change or delete log data by modifying a file, a different vulnerability than CVE-2011-0770."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "arcsight-windows-event-priv-escalation(68855)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68855"
},
{
"name": "VU#122054",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/122054"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2011-2779",
"datePublished": "2011-07-19T21:00:00",
"dateReserved": "2011-07-19T00:00:00",
"dateUpdated": "2024-08-06T23:15:30.796Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2011-0770 (GCVE-0-2011-0770)
Vulnerability from nvd – Published: 2011-07-19 20:00 – Updated: 2024-08-06 22:05
VLAI?
Summary
Cross-site scripting (XSS) vulnerability in Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 allows remote attackers to inject arbitrary web script or HTML via the Windows XP variable in a file.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T22:05:53.744Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "arcsight-connector-xss(68569)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68569"
},
{
"name": "48694",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/48694"
},
{
"name": "VU#122054",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/122054"
},
{
"name": "1025791",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://securitytracker.com/id?1025791"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2011-07-15T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 allows remote attackers to inject arbitrary web script or HTML via the Windows XP variable in a file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-16T14:57:01",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"name": "arcsight-connector-xss(68569)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68569"
},
{
"name": "48694",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/48694"
},
{
"name": "VU#122054",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/122054"
},
{
"name": "1025791",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://securitytracker.com/id?1025791"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2011-0770",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site scripting (XSS) vulnerability in Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 allows remote attackers to inject arbitrary web script or HTML via the Windows XP variable in a file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "arcsight-connector-xss(68569)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68569"
},
{
"name": "48694",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/48694"
},
{
"name": "VU#122054",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/122054"
},
{
"name": "1025791",
"refsource": "SECTRACK",
"url": "http://securitytracker.com/id?1025791"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2011-0770",
"datePublished": "2011-07-19T20:00:00",
"dateReserved": "2011-02-03T00:00:00",
"dateUpdated": "2024-08-06T22:05:53.744Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2011-2779 (GCVE-0-2011-2779)
Vulnerability from cvelistv5 – Published: 2011-07-19 21:00 – Updated: 2024-08-06 23:15
VLAI?
Summary
Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 uses world-writable permissions for exported report files, which allows local users to change or delete log data by modifying a file, a different vulnerability than CVE-2011-0770.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:15:30.796Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "arcsight-windows-event-priv-escalation(68855)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68855"
},
{
"name": "VU#122054",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/122054"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2011-07-15T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 uses world-writable permissions for exported report files, which allows local users to change or delete log data by modifying a file, a different vulnerability than CVE-2011-0770."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-28T12:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "arcsight-windows-event-priv-escalation(68855)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68855"
},
{
"name": "VU#122054",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/122054"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2011-2779",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 uses world-writable permissions for exported report files, which allows local users to change or delete log data by modifying a file, a different vulnerability than CVE-2011-0770."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "arcsight-windows-event-priv-escalation(68855)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68855"
},
{
"name": "VU#122054",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/122054"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2011-2779",
"datePublished": "2011-07-19T21:00:00",
"dateReserved": "2011-07-19T00:00:00",
"dateUpdated": "2024-08-06T23:15:30.796Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2011-0770 (GCVE-0-2011-0770)
Vulnerability from cvelistv5 – Published: 2011-07-19 20:00 – Updated: 2024-08-06 22:05
VLAI?
Summary
Cross-site scripting (XSS) vulnerability in Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 allows remote attackers to inject arbitrary web script or HTML via the Windows XP variable in a file.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T22:05:53.744Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "arcsight-connector-xss(68569)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68569"
},
{
"name": "48694",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/48694"
},
{
"name": "VU#122054",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/122054"
},
{
"name": "1025791",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://securitytracker.com/id?1025791"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2011-07-15T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 allows remote attackers to inject arbitrary web script or HTML via the Windows XP variable in a file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-16T14:57:01",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"name": "arcsight-connector-xss(68569)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68569"
},
{
"name": "48694",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/48694"
},
{
"name": "VU#122054",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/122054"
},
{
"name": "1025791",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://securitytracker.com/id?1025791"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2011-0770",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site scripting (XSS) vulnerability in Windows Event Log SmartConnector in HP ArcSight Connector Appliance before 6.1 allows remote attackers to inject arbitrary web script or HTML via the Windows XP variable in a file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "arcsight-connector-xss(68569)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68569"
},
{
"name": "48694",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/48694"
},
{
"name": "VU#122054",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/122054"
},
{
"name": "1025791",
"refsource": "SECTRACK",
"url": "http://securitytracker.com/id?1025791"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2011-0770",
"datePublished": "2011-07-19T20:00:00",
"dateReserved": "2011-02-03T00:00:00",
"dateUpdated": "2024-08-06T22:05:53.744Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}