Search

Find a vulnerability

Search criteria

    16 vulnerabilities found for alpha5_smart_loader_firmware by fujielectric

    CVE-2022-24383 (GCVE-0-2022-24383)

    Vulnerability from nvd – Published: 2022-04-12 16:11 – Updated: 2025-04-16 17:55
    VLAI
    Title
    ICSA-22-090-03 Fuji Electric Alpha5
    Summary
    The affected product is vulnerable to an out-of-bounds read, which may result in code execution
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Affected: All , < 4.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-31 00:00
    Credits
    Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:07:02.533Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-24383",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:48.595288Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:55:50.569Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "lessThan": "4.3",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
            }
          ],
          "datePublic": "2022-03-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to an out-of-bounds read, which may result in code execution"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-12T16:11:53.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
            }
          ],
          "source": {
            "advisory": "ICSA-22-090-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-090-03 Fuji Electric Alpha5",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
              "ID": "CVE-2022-24383",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "4.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to an out-of-bounds read, which may result in code execution"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-125 Out-of-bounds Read"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
              }
            ],
            "source": {
              "advisory": "ICSA-22-090-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-24383",
        "datePublished": "2022-04-12T16:11:53.500Z",
        "dateReserved": "2022-02-08T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:55:50.569Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-21228 (GCVE-0-2022-21228)

    Vulnerability from nvd – Published: 2022-04-12 16:11 – Updated: 2025-04-16 17:55
    VLAI
    Title
    ICSA-22-090-03 Fuji Electric Alpha5
    Summary
    The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Affected: All , < 4.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-31 00:00
    Credits
    Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T02:31:59.332Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-21228",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:51.306782Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:55:58.282Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "lessThan": "4.3",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
            }
          ],
          "datePublic": "2022-03-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-12T16:11:52.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
            }
          ],
          "source": {
            "advisory": "ICSA-22-090-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-090-03 Fuji Electric Alpha5",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
              "ID": "CVE-2022-21228",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "4.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121 Stack-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
              }
            ],
            "source": {
              "advisory": "ICSA-22-090-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-21228",
        "datePublished": "2022-04-12T16:11:52.740Z",
        "dateReserved": "2022-02-08T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:55:58.282Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-21214 (GCVE-0-2022-21214)

    Vulnerability from nvd – Published: 2022-04-12 16:11 – Updated: 2025-04-16 17:56
    VLAI
    Title
    ICSA-22-090-03 Fuji Electric Alpha5
    Summary
    The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Affected: All , < 4.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-31 00:00
    Credits
    Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T02:31:59.232Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-21214",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:53.975635Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:56:06.297Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "lessThan": "4.3",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
            }
          ],
          "datePublic": "2022-03-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-12T16:11:51.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
            }
          ],
          "source": {
            "advisory": "ICSA-22-090-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-090-03 Fuji Electric Alpha5",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
              "ID": "CVE-2022-21214",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "4.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-122 Heap-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
              }
            ],
            "source": {
              "advisory": "ICSA-22-090-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-21214",
        "datePublished": "2022-04-12T16:11:51.679Z",
        "dateReserved": "2022-02-08T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:56:06.297Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-21202 (GCVE-0-2022-21202)

    Vulnerability from nvd – Published: 2022-04-12 16:11 – Updated: 2025-04-16 16:30
    VLAI
    Title
    ICSA-22-090-03 Fuji Electric Alpha5
    Summary
    The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Affected: All , < 4.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-31 00:00
    Credits
    Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T02:31:58.993Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-21202",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:54:43.032875Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:30:47.541Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "lessThan": "4.3",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
            }
          ],
          "datePublic": "2022-03-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-12T16:11:54.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
            }
          ],
          "source": {
            "advisory": "ICSA-22-090-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-090-03 Fuji Electric Alpha5",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
              "ID": "CVE-2022-21202",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "4.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-125 Out-of-bounds Read"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
              }
            ],
            "source": {
              "advisory": "ICSA-22-090-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-21202",
        "datePublished": "2022-04-12T16:11:54.258Z",
        "dateReserved": "2022-02-08T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:30:47.541Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-21168 (GCVE-0-2022-21168)

    Vulnerability from nvd – Published: 2022-04-12 16:11 – Updated: 2025-04-16 16:30
    VLAI
    Title
    ICSA-22-090-03 Fuji Electric Alpha5
    Summary
    The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-824 - Access of Uninitialized Pointer
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Affected: All , < 4.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-31 00:00
    Credits
    Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T02:31:59.723Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-21168",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:54:46.252298Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:30:55.958Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "lessThan": "4.3",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
            }
          ],
          "datePublic": "2022-03-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-824",
                  "description": "CWE-824 Access of Uninitialized Pointer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-12T16:11:50.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
            }
          ],
          "source": {
            "advisory": "ICSA-22-090-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-090-03 Fuji Electric Alpha5",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
              "ID": "CVE-2022-21168",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "4.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-824 Access of Uninitialized Pointer"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
              }
            ],
            "source": {
              "advisory": "ICSA-22-090-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-21168",
        "datePublished": "2022-04-12T16:11:50.947Z",
        "dateReserved": "2022-02-08T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:30:55.958Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13520 (GCVE-0-2019-13520)

    Vulnerability from nvd – Published: 2019-08-20 19:38 – Updated: 2024-08-04 23:57
    VLAI
    Summary
    Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application.
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - Stack-Based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    n/a Alpha5 Smart Loader Affected: All versions prior to 4.2
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:57:38.997Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5 Smart Loader",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to 4.2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-Based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-11T20:06:08.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2019-13520",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5 Smart Loader",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to 4.2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121 Stack-Based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2019-13520",
        "datePublished": "2019-08-20T19:38:39.000Z",
        "dateReserved": "2019-07-11T00:00:00.000Z",
        "dateUpdated": "2024-08-04T23:57:38.997Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14794 (GCVE-0-2018-14794)

    Vulnerability from nvd – Published: 2018-10-01 13:00 – Updated: 2024-09-16 17:14
    VLAI
    Summary
    Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer.
    Severity
    No CVSS data available.
    CWE
    • CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Smart Loader Affected: 3.7 and prior
    Create a notification for this product.
    Date Public
    2018-09-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.984Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "105411",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/105411"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5 Smart Loader",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.7 and prior"
                }
              ]
            }
          ],
          "datePublic": "2018-09-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-02T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "105411",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/105411"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-09-27T00:00:00",
              "ID": "CVE-2018-14794",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5 Smart Loader",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "3.7 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "105411",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/105411"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-14794",
        "datePublished": "2018-10-01T13:00:00.000Z",
        "dateReserved": "2018-08-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:14:37.175Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14788 (GCVE-0-2018-14788)

    Vulnerability from nvd – Published: 2018-10-01 13:00 – Updated: 2024-09-17 01:35
    VLAI
    Summary
    Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types.
    Severity
    No CVSS data available.
    CWE
    • CWE-120 - BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Smart Loader Affected: 3.7 and prior
    Create a notification for this product.
    Date Public
    2018-09-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.975Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "105411",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/105411"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5 Smart Loader",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.7 and prior"
                }
              ]
            }
          ],
          "datePublic": "2018-09-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-02T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "105411",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/105411"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-09-27T00:00:00",
              "ID": "CVE-2018-14788",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5 Smart Loader",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "3.7 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "105411",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/105411"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-14788",
        "datePublished": "2018-10-01T13:00:00.000Z",
        "dateReserved": "2018-08-01T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:35:37.005Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-21202 (GCVE-0-2022-21202)

    Vulnerability from cvelistv5 – Published: 2022-04-12 16:11 – Updated: 2025-04-16 16:30
    VLAI
    Title
    ICSA-22-090-03 Fuji Electric Alpha5
    Summary
    The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Affected: All , < 4.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-31 00:00
    Credits
    Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T02:31:58.993Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-21202",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:54:43.032875Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:30:47.541Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "lessThan": "4.3",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
            }
          ],
          "datePublic": "2022-03-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-12T16:11:54.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
            }
          ],
          "source": {
            "advisory": "ICSA-22-090-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-090-03 Fuji Electric Alpha5",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
              "ID": "CVE-2022-21202",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "4.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-125 Out-of-bounds Read"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
              }
            ],
            "source": {
              "advisory": "ICSA-22-090-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-21202",
        "datePublished": "2022-04-12T16:11:54.258Z",
        "dateReserved": "2022-02-08T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:30:47.541Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-24383 (GCVE-0-2022-24383)

    Vulnerability from cvelistv5 – Published: 2022-04-12 16:11 – Updated: 2025-04-16 17:55
    VLAI
    Title
    ICSA-22-090-03 Fuji Electric Alpha5
    Summary
    The affected product is vulnerable to an out-of-bounds read, which may result in code execution
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Affected: All , < 4.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-31 00:00
    Credits
    Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:07:02.533Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-24383",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:48.595288Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:55:50.569Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "lessThan": "4.3",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
            }
          ],
          "datePublic": "2022-03-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to an out-of-bounds read, which may result in code execution"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-12T16:11:53.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
            }
          ],
          "source": {
            "advisory": "ICSA-22-090-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-090-03 Fuji Electric Alpha5",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
              "ID": "CVE-2022-24383",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "4.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to an out-of-bounds read, which may result in code execution"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-125 Out-of-bounds Read"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
              }
            ],
            "source": {
              "advisory": "ICSA-22-090-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-24383",
        "datePublished": "2022-04-12T16:11:53.500Z",
        "dateReserved": "2022-02-08T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:55:50.569Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-21228 (GCVE-0-2022-21228)

    Vulnerability from cvelistv5 – Published: 2022-04-12 16:11 – Updated: 2025-04-16 17:55
    VLAI
    Title
    ICSA-22-090-03 Fuji Electric Alpha5
    Summary
    The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Affected: All , < 4.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-31 00:00
    Credits
    Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T02:31:59.332Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-21228",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:51.306782Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:55:58.282Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "lessThan": "4.3",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
            }
          ],
          "datePublic": "2022-03-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-12T16:11:52.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
            }
          ],
          "source": {
            "advisory": "ICSA-22-090-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-090-03 Fuji Electric Alpha5",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
              "ID": "CVE-2022-21228",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "4.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121 Stack-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
              }
            ],
            "source": {
              "advisory": "ICSA-22-090-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-21228",
        "datePublished": "2022-04-12T16:11:52.740Z",
        "dateReserved": "2022-02-08T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:55:58.282Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-21214 (GCVE-0-2022-21214)

    Vulnerability from cvelistv5 – Published: 2022-04-12 16:11 – Updated: 2025-04-16 17:56
    VLAI
    Title
    ICSA-22-090-03 Fuji Electric Alpha5
    Summary
    The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Affected: All , < 4.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-31 00:00
    Credits
    Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T02:31:59.232Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-21214",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:53.975635Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:56:06.297Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "lessThan": "4.3",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
            }
          ],
          "datePublic": "2022-03-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-12T16:11:51.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
            }
          ],
          "source": {
            "advisory": "ICSA-22-090-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-090-03 Fuji Electric Alpha5",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
              "ID": "CVE-2022-21214",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "4.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-122 Heap-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
              }
            ],
            "source": {
              "advisory": "ICSA-22-090-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-21214",
        "datePublished": "2022-04-12T16:11:51.679Z",
        "dateReserved": "2022-02-08T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:56:06.297Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-21168 (GCVE-0-2022-21168)

    Vulnerability from cvelistv5 – Published: 2022-04-12 16:11 – Updated: 2025-04-16 16:30
    VLAI
    Title
    ICSA-22-090-03 Fuji Electric Alpha5
    Summary
    The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-824 - Access of Uninitialized Pointer
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Affected: All , < 4.3 (custom)
    Create a notification for this product.
    Date Public
    2022-03-31 00:00
    Credits
    Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T02:31:59.723Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-21168",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:54:46.252298Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:30:55.958Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "lessThan": "4.3",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
            }
          ],
          "datePublic": "2022-03-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-824",
                  "description": "CWE-824 Access of Uninitialized Pointer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-12T16:11:50.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
            }
          ],
          "source": {
            "advisory": "ICSA-22-090-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-090-03 Fuji Electric Alpha5",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
              "ID": "CVE-2022-21168",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "4.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-824 Access of Uninitialized Pointer"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
              }
            ],
            "source": {
              "advisory": "ICSA-22-090-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-21168",
        "datePublished": "2022-04-12T16:11:50.947Z",
        "dateReserved": "2022-02-08T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:30:55.958Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13520 (GCVE-0-2019-13520)

    Vulnerability from cvelistv5 – Published: 2019-08-20 19:38 – Updated: 2024-08-04 23:57
    VLAI
    Summary
    Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application.
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - Stack-Based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    n/a Alpha5 Smart Loader Affected: All versions prior to 4.2
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:57:38.997Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5 Smart Loader",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to 4.2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-Based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-11T20:06:08.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2019-13520",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5 Smart Loader",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to 4.2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121 Stack-Based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2019-13520",
        "datePublished": "2019-08-20T19:38:39.000Z",
        "dateReserved": "2019-07-11T00:00:00.000Z",
        "dateUpdated": "2024-08-04T23:57:38.997Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14788 (GCVE-0-2018-14788)

    Vulnerability from cvelistv5 – Published: 2018-10-01 13:00 – Updated: 2024-09-17 01:35
    VLAI
    Summary
    Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types.
    Severity
    No CVSS data available.
    CWE
    • CWE-120 - BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Smart Loader Affected: 3.7 and prior
    Create a notification for this product.
    Date Public
    2018-09-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.975Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "105411",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/105411"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5 Smart Loader",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.7 and prior"
                }
              ]
            }
          ],
          "datePublic": "2018-09-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-02T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "105411",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/105411"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-09-27T00:00:00",
              "ID": "CVE-2018-14788",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5 Smart Loader",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "3.7 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "105411",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/105411"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-14788",
        "datePublished": "2018-10-01T13:00:00.000Z",
        "dateReserved": "2018-08-01T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:35:37.005Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14794 (GCVE-0-2018-14794)

    Vulnerability from cvelistv5 – Published: 2018-10-01 13:00 – Updated: 2024-09-16 17:14
    VLAI
    Summary
    Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer.
    Severity
    No CVSS data available.
    CWE
    • CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
    Assigner
    References
    Impacted products
    Vendor Product Version
    Fuji Electric Alpha5 Smart Loader Affected: 3.7 and prior
    Create a notification for this product.
    Date Public
    2018-09-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.984Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "105411",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/105411"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Alpha5 Smart Loader",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.7 and prior"
                }
              ]
            }
          ],
          "datePublic": "2018-09-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-02T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "105411",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/105411"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-09-27T00:00:00",
              "ID": "CVE-2018-14794",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Alpha5 Smart Loader",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "3.7 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "105411",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/105411"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-14794",
        "datePublished": "2018-10-01T13:00:00.000Z",
        "dateReserved": "2018-08-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:14:37.175Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }