Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for access by bosch

    CVE-2019-11899 (GCVE-0-2019-11899)

    Vulnerability from nvd – Published: 2019-09-12 18:30 – Updated: 2024-09-17 02:17
    VLAI
    Summary
    An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator.
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    Bosch Access Professional Edition Affected: unspecified , ≤ 3.7 (custom)
    Create a notification for this product.
    Date Public
    2019-09-11 00:00
    Credits
    Oleksii Orekhov
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:10:29.632Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Access Professional Edition",
              "vendor": "Bosch",
              "versions": [
                {
                  "lessThanOrEqual": "3.7",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Oleksii Orekhov"
            }
          ],
          "datePublic": "2019-09-11T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-12T18:30:58.000Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.7"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@bosch.com",
              "DATE_PUBLIC": "2019-09-11T00:00:00.000Z",
              "ID": "CVE-2019-11899",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Access Professional Edition",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "3.7"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Bosch"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Oleksii Orekhov"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.7"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-284 Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2019-11899",
        "datePublished": "2019-09-12T18:30:58.728Z",
        "dateReserved": "2019-05-13T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:17:02.364Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-11898 (GCVE-0-2019-11898)

    Vulnerability from nvd – Published: 2019-09-12 18:23 – Updated: 2024-09-17 04:09
    VLAI
    Summary
    Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8.
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    References
    Impacted products
    Vendor Product Version
    Bosch Access Professional Edition Affected: unspecified , ≤ 3.7 (custom)
    Create a notification for this product.
    Date Public
    2019-09-11 00:00
    Credits
    Oleksii Orekhov
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:10:29.542Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Access Professional Edition",
              "vendor": "Bosch",
              "versions": [
                {
                  "lessThanOrEqual": "3.7",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Oleksii Orekhov"
            }
          ],
          "datePublic": "2019-09-11T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-12T18:23:21.000Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.7"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@bosch.com",
              "DATE_PUBLIC": "2019-09-11T00:00:00.000Z",
              "ID": "CVE-2019-11898",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Access Professional Edition",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "3.7"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Bosch"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Oleksii Orekhov"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.7"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-798 Use of Hard-coded Credentials"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2019-11898",
        "datePublished": "2019-09-12T18:23:21.989Z",
        "dateReserved": "2019-05-13T00:00:00.000Z",
        "dateUpdated": "2024-09-17T04:09:20.767Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-11899 (GCVE-0-2019-11899)

    Vulnerability from cvelistv5 – Published: 2019-09-12 18:30 – Updated: 2024-09-17 02:17
    VLAI
    Summary
    An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator.
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    Bosch Access Professional Edition Affected: unspecified , ≤ 3.7 (custom)
    Create a notification for this product.
    Date Public
    2019-09-11 00:00
    Credits
    Oleksii Orekhov
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:10:29.632Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Access Professional Edition",
              "vendor": "Bosch",
              "versions": [
                {
                  "lessThanOrEqual": "3.7",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Oleksii Orekhov"
            }
          ],
          "datePublic": "2019-09-11T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-12T18:30:58.000Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.7"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@bosch.com",
              "DATE_PUBLIC": "2019-09-11T00:00:00.000Z",
              "ID": "CVE-2019-11899",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Access Professional Edition",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "3.7"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Bosch"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Oleksii Orekhov"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.7"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-284 Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2019-11899",
        "datePublished": "2019-09-12T18:30:58.728Z",
        "dateReserved": "2019-05-13T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:17:02.364Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-11898 (GCVE-0-2019-11898)

    Vulnerability from cvelistv5 – Published: 2019-09-12 18:23 – Updated: 2024-09-17 04:09
    VLAI
    Summary
    Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8.
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    References
    Impacted products
    Vendor Product Version
    Bosch Access Professional Edition Affected: unspecified , ≤ 3.7 (custom)
    Create a notification for this product.
    Date Public
    2019-09-11 00:00
    Credits
    Oleksii Orekhov
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:10:29.542Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Access Professional Edition",
              "vendor": "Bosch",
              "versions": [
                {
                  "lessThanOrEqual": "3.7",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Oleksii Orekhov"
            }
          ],
          "datePublic": "2019-09-11T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-12T18:23:21.000Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.7"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@bosch.com",
              "DATE_PUBLIC": "2019-09-11T00:00:00.000Z",
              "ID": "CVE-2019-11898",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Access Professional Edition",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "3.7"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Bosch"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Oleksii Orekhov"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.7"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-798 Use of Hard-coded Credentials"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2019-11898",
        "datePublished": "2019-09-12T18:23:21.989Z",
        "dateReserved": "2019-05-13T00:00:00.000Z",
        "dateUpdated": "2024-09-17T04:09:20.767Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }