Search criteria

4 vulnerabilities found for access by bosch

CVE-2019-11899 (GCVE-0-2019-11899)

Vulnerability from nvd – Published: 2019-09-12 18:30 – Updated: 2024-09-17 02:17
VLAI?
Summary
An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Bosch Access Professional Edition Affected: unspecified , ≤ 3.7 (custom)
Create a notification for this product.
Credits
Oleksii Orekhov
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.632Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Professional Edition",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "3.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Oleksii Orekhov"
        }
      ],
      "datePublic": "2019-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-12T18:30:58",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-09-11T00:00:00.000Z",
          "ID": "CVE-2019-11899",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Professional Edition",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Oleksii Orekhov"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11899",
    "datePublished": "2019-09-12T18:30:58.728052Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-17T02:17:02.364Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-11898 (GCVE-0-2019-11898)

Vulnerability from nvd – Published: 2019-09-12 18:23 – Updated: 2024-09-17 04:09
VLAI?
Summary
Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
Vendor Product Version
Bosch Access Professional Edition Affected: unspecified , ≤ 3.7 (custom)
Create a notification for this product.
Credits
Oleksii Orekhov
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.542Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Professional Edition",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "3.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Oleksii Orekhov"
        }
      ],
      "datePublic": "2019-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-12T18:23:21",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-09-11T00:00:00.000Z",
          "ID": "CVE-2019-11898",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Professional Edition",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Oleksii Orekhov"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798 Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11898",
    "datePublished": "2019-09-12T18:23:21.989608Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-17T04:09:20.767Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-11899 (GCVE-0-2019-11899)

Vulnerability from cvelistv5 – Published: 2019-09-12 18:30 – Updated: 2024-09-17 02:17
VLAI?
Summary
An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Bosch Access Professional Edition Affected: unspecified , ≤ 3.7 (custom)
Create a notification for this product.
Credits
Oleksii Orekhov
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.632Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Professional Edition",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "3.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Oleksii Orekhov"
        }
      ],
      "datePublic": "2019-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-12T18:30:58",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-09-11T00:00:00.000Z",
          "ID": "CVE-2019-11899",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Professional Edition",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Oleksii Orekhov"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11899",
    "datePublished": "2019-09-12T18:30:58.728052Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-17T02:17:02.364Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-11898 (GCVE-0-2019-11898)

Vulnerability from cvelistv5 – Published: 2019-09-12 18:23 – Updated: 2024-09-17 04:09
VLAI?
Summary
Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
Vendor Product Version
Bosch Access Professional Edition Affected: unspecified , ≤ 3.7 (custom)
Create a notification for this product.
Credits
Oleksii Orekhov
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.542Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Professional Edition",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "3.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Oleksii Orekhov"
        }
      ],
      "datePublic": "2019-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-12T18:23:21",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-09-11T00:00:00.000Z",
          "ID": "CVE-2019-11898",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Professional Edition",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Oleksii Orekhov"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798 Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11898",
    "datePublished": "2019-09-12T18:23:21.989608Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-17T04:09:20.767Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}