Search criteria
23 vulnerabilities found for ac8v4 by tenda
VAR-202308-2836
Vulnerability from variot - Updated: 2025-12-18 00:37Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sscanf function. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state.
There is a buffer overflow vulnerability in Tenda AC8V4 V16.03.34.06. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-2836",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.6,
"vendor": "jixiang tengda",
"version": "v16.03.34.06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-00982"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022372"
},
{
"db": "NVD",
"id": "CVE-2023-39786"
}
]
},
"cve": "CVE-2023-39786",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-00982",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2023-39786",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2023-39786",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-39786",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2023-39786",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-00982",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-00982"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022372"
},
{
"db": "NVD",
"id": "CVE-2023-39786"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sscanf function. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. \n\nThere is a buffer overflow vulnerability in Tenda AC8V4 V16.03.34.06. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-39786"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022372"
},
{
"db": "CNVD",
"id": "CNVD-2025-00982"
},
{
"db": "VULMON",
"id": "CVE-2023-39786"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-39786",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022372",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-00982",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-39786",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-00982"
},
{
"db": "VULMON",
"id": "CVE-2023-39786"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022372"
},
{
"db": "NVD",
"id": "CVE-2023-39786"
}
]
},
"id": "VAR-202308-2836",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-00982"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-00982"
}
]
},
"last_update_date": "2025-12-18T00:37:33.030000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022372"
},
{
"db": "NVD",
"id": "CVE-2023-39786"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.9,
"url": "http://tenda.com"
},
{
"trust": 1.9,
"url": "https://github.com/xunflash/iot/tree/main/tenda_ac8_v4/3"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-39786"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-00982"
},
{
"db": "VULMON",
"id": "CVE-2023-39786"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022372"
},
{
"db": "NVD",
"id": "CVE-2023-39786"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-00982"
},
{
"db": "VULMON",
"id": "CVE-2023-39786"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022372"
},
{
"db": "NVD",
"id": "CVE-2023-39786"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-01-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-00982"
},
{
"date": "2023-08-21T00:00:00",
"db": "VULMON",
"id": "CVE-2023-39786"
},
{
"date": "2024-01-23T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022372"
},
{
"date": "2023-08-21T01:15:09.357000",
"db": "NVD",
"id": "CVE-2023-39786"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-01-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-00982"
},
{
"date": "2023-08-21T00:00:00",
"db": "VULMON",
"id": "CVE-2023-39786"
},
{
"date": "2024-01-23T01:41:00",
"db": "JVNDB",
"id": "JVNDB-2023-022372"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-39786"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022372"
}
],
"trust": 0.8
}
}
VAR-202308-3470
Vulnerability from variot - Updated: 2025-12-18 00:36Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for fiber-optic homes with speeds up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker can exploit this vulnerability by submitting specially crafted requests that could cause the application to crash or execute arbitrary code in the application's context
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3470",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8 us ac8v4.0si v16.03.34.06 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20664"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022716"
},
{
"db": "NVD",
"id": "CVE-2023-40892"
}
]
},
"cve": "CVE-2023-40892",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20664",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-40892",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-40892",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-40892",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-40892",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-20664",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20664"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022716"
},
{
"db": "NVD",
"id": "CVE-2023-40892"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for fiber-optic homes with speeds up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker can exploit this vulnerability by submitting specially crafted requests that could cause the application to crash or execute arbitrary code in the application\u0027s context",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-40892"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022716"
},
{
"db": "CNVD",
"id": "CNVD-2025-20664"
},
{
"db": "VULMON",
"id": "CVE-2023-40892"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-40892",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022716",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20664",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-40892",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20664"
},
{
"db": "VULMON",
"id": "CVE-2023-40892"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022716"
},
{
"db": "NVD",
"id": "CVE-2023-40892"
}
]
},
"id": "VAR-202308-3470",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20664"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20664"
}
]
},
"last_update_date": "2025-12-18T00:36:37.595000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022716"
},
{
"db": "NVD",
"id": "CVE-2023-40892"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/peris-navince/founded-0-days/blob/main/ac8/setschedewifi/1.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-40892"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20664"
},
{
"db": "VULMON",
"id": "CVE-2023-40892"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022716"
},
{
"db": "NVD",
"id": "CVE-2023-40892"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20664"
},
{
"db": "VULMON",
"id": "CVE-2023-40892"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022716"
},
{
"db": "NVD",
"id": "CVE-2023-40892"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20664"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40892"
},
{
"date": "2024-01-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022716"
},
{
"date": "2023-08-24T18:15:07.707000",
"db": "NVD",
"id": "CVE-2023-40892"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20664"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40892"
},
{
"date": "2024-01-24T01:57:00",
"db": "JVNDB",
"id": "JVNDB-2023-022716"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-40892"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022716"
}
],
"trust": 0.8
}
}
VAR-202308-3601
Vulnerability from variot - Updated: 2025-12-18 00:35Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker can exploit this vulnerability by submitting a specially crafted request to cause the application to crash or execute arbitrary code in the application's context
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3601",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8 us ac8v4.0si v16.03.34.06 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20709"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022712"
},
{
"db": "NVD",
"id": "CVE-2023-40896"
}
]
},
"cve": "CVE-2023-40896",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20709",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-40896",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-40896",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-40896",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-40896",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-20709",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20709"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022712"
},
{
"db": "NVD",
"id": "CVE-2023-40896"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker can exploit this vulnerability by submitting a specially crafted request to cause the application to crash or execute arbitrary code in the application\u0027s context",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-40896"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022712"
},
{
"db": "CNVD",
"id": "CNVD-2025-20709"
},
{
"db": "VULMON",
"id": "CVE-2023-40896"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-40896",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022712",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20709",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-40896",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20709"
},
{
"db": "VULMON",
"id": "CVE-2023-40896"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022712"
},
{
"db": "NVD",
"id": "CVE-2023-40896"
}
]
},
"id": "VAR-202308-3601",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20709"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20709"
}
]
},
"last_update_date": "2025-12-18T00:35:43.942000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022712"
},
{
"db": "NVD",
"id": "CVE-2023-40896"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/peris-navince/founded-0-days/blob/main/ac8/setipmacbind/1.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-40896"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20709"
},
{
"db": "VULMON",
"id": "CVE-2023-40896"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022712"
},
{
"db": "NVD",
"id": "CVE-2023-40896"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20709"
},
{
"db": "VULMON",
"id": "CVE-2023-40896"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022712"
},
{
"db": "NVD",
"id": "CVE-2023-40896"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20709"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40896"
},
{
"date": "2024-01-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022712"
},
{
"date": "2023-08-24T18:15:07.943000",
"db": "NVD",
"id": "CVE-2023-40896"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20709"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40896"
},
{
"date": "2024-01-24T01:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-022712"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-40896"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022712"
}
],
"trust": 0.8
}
}
VAR-202308-3330
Vulnerability from variot - Updated: 2025-12-18 00:35Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for fiber-optic homes with speeds up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker could exploit this vulnerability by submitting a specially crafted request to cause the application to crash or execute arbitrary code in the application's context
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3330",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8 us ac8v4.0si v16.03.34.06 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20713"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022705"
},
{
"db": "NVD",
"id": "CVE-2023-40900"
}
]
},
"cve": "CVE-2023-40900",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20713",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-40900",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-40900",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-40900",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-40900",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-20713",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20713"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022705"
},
{
"db": "NVD",
"id": "CVE-2023-40900"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for fiber-optic homes with speeds up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker could exploit this vulnerability by submitting a specially crafted request to cause the application to crash or execute arbitrary code in the application\u0027s context",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-40900"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022705"
},
{
"db": "CNVD",
"id": "CNVD-2025-20713"
},
{
"db": "VULMON",
"id": "CVE-2023-40900"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-40900",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022705",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20713",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-40900",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20713"
},
{
"db": "VULMON",
"id": "CVE-2023-40900"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022705"
},
{
"db": "NVD",
"id": "CVE-2023-40900"
}
]
},
"id": "VAR-202308-3330",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20713"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20713"
}
]
},
"last_update_date": "2025-12-18T00:35:21.287000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022705"
},
{
"db": "NVD",
"id": "CVE-2023-40900"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/peris-navince/founded-0-days/blob/main/ac8/formsetqosband/1.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-40900"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20713"
},
{
"db": "VULMON",
"id": "CVE-2023-40900"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022705"
},
{
"db": "NVD",
"id": "CVE-2023-40900"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20713"
},
{
"db": "VULMON",
"id": "CVE-2023-40900"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022705"
},
{
"db": "NVD",
"id": "CVE-2023-40900"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20713"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40900"
},
{
"date": "2024-01-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022705"
},
{
"date": "2023-08-24T18:15:08.173000",
"db": "NVD",
"id": "CVE-2023-40900"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20713"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40900"
},
{
"date": "2024-01-24T01:45:00",
"db": "JVNDB",
"id": "JVNDB-2023-022705"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-40900"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022705"
}
],
"trust": 0.8
}
}
VAR-202308-3226
Vulnerability from variot - Updated: 2025-12-18 00:34Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter mac at /goform/GetParentControlInfo. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker could exploit this vulnerability by submitting a specially crafted request to cause the application to crash or execute arbitrary code in the application's context
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3226",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8 us ac8v4.0si v16.03.34.06 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20710"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022711"
},
{
"db": "NVD",
"id": "CVE-2023-40897"
}
]
},
"cve": "CVE-2023-40897",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20710",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-40897",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-40897",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-40897",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-40897",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-20710",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20710"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022711"
},
{
"db": "NVD",
"id": "CVE-2023-40897"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter mac at /goform/GetParentControlInfo. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker could exploit this vulnerability by submitting a specially crafted request to cause the application to crash or execute arbitrary code in the application\u0027s context",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-40897"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022711"
},
{
"db": "CNVD",
"id": "CNVD-2025-20710"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-40897",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022711",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20710",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-40897",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20710"
},
{
"db": "VULMON",
"id": "CVE-2023-40897"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022711"
},
{
"db": "NVD",
"id": "CVE-2023-40897"
}
]
},
"id": "VAR-202308-3226",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20710"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20710"
}
]
},
"last_update_date": "2025-12-18T00:34:53.096000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022711"
},
{
"db": "NVD",
"id": "CVE-2023-40897"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/peris-navince/founded-0-days/blob/main/ac8/getparentcontrolinfo/1.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-40897"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20710"
},
{
"db": "VULMON",
"id": "CVE-2023-40897"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022711"
},
{
"db": "NVD",
"id": "CVE-2023-40897"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20710"
},
{
"db": "VULMON",
"id": "CVE-2023-40897"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022711"
},
{
"db": "NVD",
"id": "CVE-2023-40897"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20710"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40897"
},
{
"date": "2024-01-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022711"
},
{
"date": "2023-08-24T18:15:08",
"db": "NVD",
"id": "CVE-2023-40897"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20710"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40897"
},
{
"date": "2024-01-24T01:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-022711"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-40897"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022711"
}
],
"trust": 0.8
}
}
VAR-202308-2793
Vulnerability from variot - Updated: 2025-12-18 00:32Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the save_virtualser_data function. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker could exploit this vulnerability to cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-2793",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.03.34.06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20716"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022370"
},
{
"db": "NVD",
"id": "CVE-2023-39784"
}
]
},
"cve": "CVE-2023-39784",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20716",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2023-39784",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2023-39784",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-39784",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2023-39784",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-20716",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20716"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022370"
},
{
"db": "NVD",
"id": "CVE-2023-39784"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the save_virtualser_data function. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker could exploit this vulnerability to cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-39784"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022370"
},
{
"db": "CNVD",
"id": "CNVD-2025-20716"
},
{
"db": "VULMON",
"id": "CVE-2023-39784"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-39784",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022370",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20716",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-39784",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20716"
},
{
"db": "VULMON",
"id": "CVE-2023-39784"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022370"
},
{
"db": "NVD",
"id": "CVE-2023-39784"
}
]
},
"id": "VAR-202308-2793",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20716"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20716"
}
]
},
"last_update_date": "2025-12-18T00:32:28.220000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022370"
},
{
"db": "NVD",
"id": "CVE-2023-39784"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.9,
"url": "http://tenda.com"
},
{
"trust": 1.9,
"url": "https://github.com/xunflash/iot/tree/main/tenda_ac8_v4"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-39784"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20716"
},
{
"db": "VULMON",
"id": "CVE-2023-39784"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022370"
},
{
"db": "NVD",
"id": "CVE-2023-39784"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20716"
},
{
"db": "VULMON",
"id": "CVE-2023-39784"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022370"
},
{
"db": "NVD",
"id": "CVE-2023-39784"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20716"
},
{
"date": "2023-08-21T00:00:00",
"db": "VULMON",
"id": "CVE-2023-39784"
},
{
"date": "2024-01-23T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022370"
},
{
"date": "2023-08-21T01:15:08.927000",
"db": "NVD",
"id": "CVE-2023-39784"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20716"
},
{
"date": "2023-08-21T00:00:00",
"db": "VULMON",
"id": "CVE-2023-39784"
},
{
"date": "2024-01-23T01:41:00",
"db": "JVNDB",
"id": "JVNDB-2023-022370"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-39784"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022370"
}
],
"trust": 0.8
}
}
VAR-202308-3191
Vulnerability from variot - Updated: 2025-12-18 00:32Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker could exploit this vulnerability by submitting specially crafted requests to cause the application to crash or execute arbitrary code in the application's context
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3191",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8 us ac8v4.0si v16.03.34.06 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20715"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022714"
},
{
"db": "NVD",
"id": "CVE-2023-40894"
}
]
},
"cve": "CVE-2023-40894",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20715",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-40894",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-40894",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-40894",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-40894",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-20715",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20715"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022714"
},
{
"db": "NVD",
"id": "CVE-2023-40894"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker could exploit this vulnerability by submitting specially crafted requests to cause the application to crash or execute arbitrary code in the application\u0027s context",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-40894"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022714"
},
{
"db": "CNVD",
"id": "CNVD-2025-20715"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-40894",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022714",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20715",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-40894",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20715"
},
{
"db": "VULMON",
"id": "CVE-2023-40894"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022714"
},
{
"db": "NVD",
"id": "CVE-2023-40894"
}
]
},
"id": "VAR-202308-3191",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20715"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20715"
}
]
},
"last_update_date": "2025-12-18T00:32:28.182000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022714"
},
{
"db": "NVD",
"id": "CVE-2023-40894"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/peris-navince/founded-0-days/blob/main/ac8/fromsetstaticroutecfg/1.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-40894"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20715"
},
{
"db": "VULMON",
"id": "CVE-2023-40894"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022714"
},
{
"db": "NVD",
"id": "CVE-2023-40894"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20715"
},
{
"db": "VULMON",
"id": "CVE-2023-40894"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022714"
},
{
"db": "NVD",
"id": "CVE-2023-40894"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20715"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40894"
},
{
"date": "2024-01-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022714"
},
{
"date": "2023-08-24T18:15:07.827000",
"db": "NVD",
"id": "CVE-2023-40894"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20715"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40894"
},
{
"date": "2024-01-24T01:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-022714"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-40894"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022714"
}
],
"trust": 0.8
}
}
VAR-202407-0512
Vulnerability from variot - Updated: 2025-12-18 00:31Vulnerability in Tenda AC8v4 .V16.03.34.09 due to sscanf and the last digit of s8 being overwritten with \x0. After executing set_client_qos, control over the gp register can be obtained. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports IPv6 and features intelligent network management
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202407-0512",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "16.03.34.09"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.09"
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24489"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-026231"
},
{
"db": "NVD",
"id": "CVE-2023-48194"
}
]
},
"cve": "CVE-2023-48194",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-24489",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-48194",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"id": "CVE-2023-48194",
"impactScore": 3.4,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-48194",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-48194",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2023-48194",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2023-48194",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-24489",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24489"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-026231"
},
{
"db": "NVD",
"id": "CVE-2023-48194"
},
{
"db": "NVD",
"id": "CVE-2023-48194"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vulnerability in Tenda AC8v4 .V16.03.34.09 due to sscanf and the last digit of s8 being overwritten with \\x0. After executing set_client_qos, control over the gp register can be obtained. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports IPv6 and features intelligent network management",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-48194"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-026231"
},
{
"db": "CNVD",
"id": "CNVD-2025-24489"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-48194",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-026231",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-24489",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24489"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-026231"
},
{
"db": "NVD",
"id": "CVE-2023-48194"
}
]
},
"id": "VAR-202407-0512",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24489"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24489"
}
]
},
"last_update_date": "2025-12-18T00:31:44.840000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-026231"
},
{
"db": "NVD",
"id": "CVE-2023-48194"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "http://tenda.com"
},
{
"trust": 1.8,
"url": "https://github.com/zt20xx/cve-2023-48194"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-48194"
},
{
"trust": 1.0,
"url": "https://www.tenda.com.cn/download/detail-3683.html"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24489"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-026231"
},
{
"db": "NVD",
"id": "CVE-2023-48194"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-24489"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-026231"
},
{
"db": "NVD",
"id": "CVE-2023-48194"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-10-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-24489"
},
{
"date": "2024-07-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-026231"
},
{
"date": "2024-07-09T18:15:08.790000",
"db": "NVD",
"id": "CVE-2023-48194"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-10-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-24489"
},
{
"date": "2024-07-16T03:02:00",
"db": "JVNDB",
"id": "JVNDB-2023-026231"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-48194"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Firmware vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-026231"
}
],
"trust": 0.8
}
}
VAR-202308-3399
Vulnerability from variot - Updated: 2025-12-18 00:31Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker can exploit this vulnerability by submitting a specially crafted request to cause the application to crash or execute arbitrary code in the application's context
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3399",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8 us ac8v4.0si v16.03.34.06 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20714"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022717"
},
{
"db": "NVD",
"id": "CVE-2023-40891"
}
]
},
"cve": "CVE-2023-40891",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20714",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-40891",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-40891",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-40891",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-40891",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-20714",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20714"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022717"
},
{
"db": "NVD",
"id": "CVE-2023-40891"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker can exploit this vulnerability by submitting a specially crafted request to cause the application to crash or execute arbitrary code in the application\u0027s context",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-40891"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022717"
},
{
"db": "CNVD",
"id": "CNVD-2025-20714"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-40891",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022717",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20714",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-40891",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20714"
},
{
"db": "VULMON",
"id": "CVE-2023-40891"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022717"
},
{
"db": "NVD",
"id": "CVE-2023-40891"
}
]
},
"id": "VAR-202308-3399",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20714"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20714"
}
]
},
"last_update_date": "2025-12-18T00:31:26.512000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022717"
},
{
"db": "NVD",
"id": "CVE-2023-40891"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/peris-navince/founded-0-days/blob/main/ac8/formsetfirewallcfg/1.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-40891"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20714"
},
{
"db": "VULMON",
"id": "CVE-2023-40891"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022717"
},
{
"db": "NVD",
"id": "CVE-2023-40891"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20714"
},
{
"db": "VULMON",
"id": "CVE-2023-40891"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022717"
},
{
"db": "NVD",
"id": "CVE-2023-40891"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20714"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40891"
},
{
"date": "2024-01-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022717"
},
{
"date": "2023-08-24T18:15:07.643000",
"db": "NVD",
"id": "CVE-2023-40891"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20714"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40891"
},
{
"date": "2024-01-24T01:57:00",
"db": "JVNDB",
"id": "JVNDB-2023-022717"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-40891"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022717"
}
],
"trust": 0.8
}
}
VAR-202308-3398
Vulnerability from variot - Updated: 2025-12-18 00:28Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000Mbps. It supports dual-band concurrent transmission rates of up to 1167Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100-1000Mbps. An attacker could exploit this vulnerability to crash the application or execute arbitrary code in the application's context
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3398",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8 us ac8v4.0si v16.03.34.06 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20663"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022713"
},
{
"db": "NVD",
"id": "CVE-2023-40895"
}
]
},
"cve": "CVE-2023-40895",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20663",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-40895",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-40895",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-40895",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-40895",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-20663",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20663"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022713"
},
{
"db": "NVD",
"id": "CVE-2023-40895"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000Mbps. It supports dual-band concurrent transmission rates of up to 1167Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100-1000Mbps. An attacker could exploit this vulnerability to crash the application or execute arbitrary code in the application\u0027s context",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-40895"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022713"
},
{
"db": "CNVD",
"id": "CNVD-2025-20663"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-40895",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022713",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20663",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-40895",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20663"
},
{
"db": "VULMON",
"id": "CVE-2023-40895"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022713"
},
{
"db": "NVD",
"id": "CVE-2023-40895"
}
]
},
"id": "VAR-202308-3398",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20663"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20663"
}
]
},
"last_update_date": "2025-12-18T00:28:36.966000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022713"
},
{
"db": "NVD",
"id": "CVE-2023-40895"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/peris-navince/founded-0-days/blob/main/ac8/formsetvirtualser/1.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-40895"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20663"
},
{
"db": "VULMON",
"id": "CVE-2023-40895"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022713"
},
{
"db": "NVD",
"id": "CVE-2023-40895"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20663"
},
{
"db": "VULMON",
"id": "CVE-2023-40895"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022713"
},
{
"db": "NVD",
"id": "CVE-2023-40895"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20663"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40895"
},
{
"date": "2024-01-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022713"
},
{
"date": "2023-08-24T18:15:07.887000",
"db": "NVD",
"id": "CVE-2023-40895"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20663"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40895"
},
{
"date": "2024-01-24T01:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-022713"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-40895"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022713"
}
],
"trust": 0.8
}
}
VAR-202308-2765
Vulnerability from variot - Updated: 2025-12-18 00:27Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the set_qosMib_list function. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. AC8 is a wireless router from China's Tenda Company. AC8V4 V16.03.34.06 version has a buffer overflow vulnerability. The vulnerability is caused by the list parameter of the set_qosMib_list function failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-2765",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.6,
"vendor": "jixiang tengda",
"version": "v16.03.34.06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08435"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022371"
},
{
"db": "NVD",
"id": "CVE-2023-39785"
}
]
},
"cve": "CVE-2023-39785",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-08435",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2023-39785",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2023-39785",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-39785",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2023-39785",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-08435",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08435"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022371"
},
{
"db": "NVD",
"id": "CVE-2023-39785"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the set_qosMib_list function. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. AC8 is a wireless router from China\u0027s Tenda Company. AC8V4 V16.03.34.06 version has a buffer overflow vulnerability. The vulnerability is caused by the list parameter of the set_qosMib_list function failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-39785"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022371"
},
{
"db": "CNVD",
"id": "CNVD-2025-08435"
},
{
"db": "VULMON",
"id": "CVE-2023-39785"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-39785",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022371",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-08435",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-39785",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08435"
},
{
"db": "VULMON",
"id": "CVE-2023-39785"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022371"
},
{
"db": "NVD",
"id": "CVE-2023-39785"
}
]
},
"id": "VAR-202308-2765",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08435"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08435"
}
]
},
"last_update_date": "2025-12-18T00:27:25.800000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022371"
},
{
"db": "NVD",
"id": "CVE-2023-39785"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.9,
"url": "http://tenda.com"
},
{
"trust": 1.9,
"url": "https://github.com/xunflash/iot/tree/main/tenda_ac8_v4/2"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-39785"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08435"
},
{
"db": "VULMON",
"id": "CVE-2023-39785"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022371"
},
{
"db": "NVD",
"id": "CVE-2023-39785"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-08435"
},
{
"db": "VULMON",
"id": "CVE-2023-39785"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022371"
},
{
"db": "NVD",
"id": "CVE-2023-39785"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-04-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-08435"
},
{
"date": "2023-08-21T00:00:00",
"db": "VULMON",
"id": "CVE-2023-39785"
},
{
"date": "2024-01-23T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022371"
},
{
"date": "2023-08-21T01:15:09.273000",
"db": "NVD",
"id": "CVE-2023-39785"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-04-27T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-08435"
},
{
"date": "2023-08-21T00:00:00",
"db": "VULMON",
"id": "CVE-2023-39785"
},
{
"date": "2024-01-23T01:41:00",
"db": "JVNDB",
"id": "JVNDB-2023-022371"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-39785"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022371"
}
],
"trust": 0.8
}
}
VAR-202308-3396
Vulnerability from variot - Updated: 2025-12-18 00:27Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for fiber-optic homes with speeds up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (one WAN port and three LAN ports), meeting broadband access needs between 100 and 1000 Mbps. An attacker could exploit this vulnerability by submitting a specially crafted request to cause the application to crash or execute arbitrary code in the application's context
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3396",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8 us ac8v4.0si v16.03.34.06 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20711"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022706"
},
{
"db": "NVD",
"id": "CVE-2023-40899"
}
]
},
"cve": "CVE-2023-40899",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20711",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-40899",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-40899",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-40899",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-40899",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-20711",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20711"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022706"
},
{
"db": "NVD",
"id": "CVE-2023-40899"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for fiber-optic homes with speeds up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (one WAN port and three LAN ports), meeting broadband access needs between 100 and 1000 Mbps. An attacker could exploit this vulnerability by submitting a specially crafted request to cause the application to crash or execute arbitrary code in the application\u0027s context",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-40899"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022706"
},
{
"db": "CNVD",
"id": "CNVD-2025-20711"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-40899",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022706",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20711",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-40899",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20711"
},
{
"db": "VULMON",
"id": "CVE-2023-40899"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022706"
},
{
"db": "NVD",
"id": "CVE-2023-40899"
}
]
},
"id": "VAR-202308-3396",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20711"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20711"
}
]
},
"last_update_date": "2025-12-18T00:27:25.745000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022706"
},
{
"db": "NVD",
"id": "CVE-2023-40899"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/peris-navince/founded-0-days/blob/main/ac8/formsetmacfiltercfg/1.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-40899"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20711"
},
{
"db": "VULMON",
"id": "CVE-2023-40899"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022706"
},
{
"db": "NVD",
"id": "CVE-2023-40899"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20711"
},
{
"db": "VULMON",
"id": "CVE-2023-40899"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022706"
},
{
"db": "NVD",
"id": "CVE-2023-40899"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20711"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40899"
},
{
"date": "2024-01-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022706"
},
{
"date": "2023-08-24T18:15:08.113000",
"db": "NVD",
"id": "CVE-2023-40899"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20711"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40899"
},
{
"date": "2024-01-24T01:45:00",
"db": "JVNDB",
"id": "JVNDB-2023-022706"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-40899"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022706"
}
],
"trust": 0.8
}
}
VAR-202308-3227
Vulnerability from variot - Updated: 2025-12-18 00:17Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for fiber-optic homes with speeds up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker can exploit this vulnerability by submitting specially crafted requests that could cause the application to crash or execute arbitrary code in the application's context
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3227",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8 us ac8v4.0si v16.03.34.06 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20665"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022715"
},
{
"db": "NVD",
"id": "CVE-2023-40893"
}
]
},
"cve": "CVE-2023-40893",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20665",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-40893",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-40893",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-40893",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-40893",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-20665",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20665"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022715"
},
{
"db": "NVD",
"id": "CVE-2023-40893"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for fiber-optic homes with speeds up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker can exploit this vulnerability by submitting specially crafted requests that could cause the application to crash or execute arbitrary code in the application\u0027s context",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-40893"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022715"
},
{
"db": "CNVD",
"id": "CNVD-2025-20665"
},
{
"db": "VULMON",
"id": "CVE-2023-40893"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-40893",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022715",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20665",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-40893",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20665"
},
{
"db": "VULMON",
"id": "CVE-2023-40893"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022715"
},
{
"db": "NVD",
"id": "CVE-2023-40893"
}
]
},
"id": "VAR-202308-3227",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20665"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20665"
}
]
},
"last_update_date": "2025-12-18T00:17:25.708000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022715"
},
{
"db": "NVD",
"id": "CVE-2023-40893"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/peris-navince/founded-0-days/blob/main/ac8/setsmartpowermanagement/1.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-40893"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20665"
},
{
"db": "VULMON",
"id": "CVE-2023-40893"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022715"
},
{
"db": "NVD",
"id": "CVE-2023-40893"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20665"
},
{
"db": "VULMON",
"id": "CVE-2023-40893"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022715"
},
{
"db": "NVD",
"id": "CVE-2023-40893"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20665"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40893"
},
{
"date": "2024-01-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022715"
},
{
"date": "2023-08-24T18:15:07.767000",
"db": "NVD",
"id": "CVE-2023-40893"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20665"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40893"
},
{
"date": "2024-01-24T01:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-022715"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-40893"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022715"
}
],
"trust": 0.8
}
}
VAR-202308-3397
Vulnerability from variot - Updated: 2025-12-18 00:09Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker could exploit this vulnerability by submitting a specially crafted request to cause the application to crash or execute arbitrary code in the application's context
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3397",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8v4 firmware 16.03.34.06"
},
{
"model": "ac8v4",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8 us ac8v4.0si v16.03.34.06 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20712"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022707"
},
{
"db": "NVD",
"id": "CVE-2023-40898"
}
]
},
"cve": "CVE-2023-40898",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20712",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-40898",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-40898",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-40898",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-40898",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-20712",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20712"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022707"
},
{
"db": "NVD",
"id": "CVE-2023-40898"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg. Shenzhen Tenda Technology Co.,Ltd. of ac8v4 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (1 WAN port + 3 LAN ports), meeting broadband access needs from 100 to 1000 Mbps. An attacker could exploit this vulnerability by submitting a specially crafted request to cause the application to crash or execute arbitrary code in the application\u0027s context",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-40898"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022707"
},
{
"db": "CNVD",
"id": "CNVD-2025-20712"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-40898",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022707",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20712",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-40898",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20712"
},
{
"db": "VULMON",
"id": "CVE-2023-40898"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022707"
},
{
"db": "NVD",
"id": "CVE-2023-40898"
}
]
},
"id": "VAR-202308-3397",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20712"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20712"
}
]
},
"last_update_date": "2025-12-18T00:09:29.738000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022707"
},
{
"db": "NVD",
"id": "CVE-2023-40898"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/peris-navince/founded-0-days/blob/main/ac8/setsystimecfg/1.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-40898"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20712"
},
{
"db": "VULMON",
"id": "CVE-2023-40898"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022707"
},
{
"db": "NVD",
"id": "CVE-2023-40898"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20712"
},
{
"db": "VULMON",
"id": "CVE-2023-40898"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-022707"
},
{
"db": "NVD",
"id": "CVE-2023-40898"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20712"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40898"
},
{
"date": "2024-01-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-022707"
},
{
"date": "2023-08-24T18:15:08.057000",
"db": "NVD",
"id": "CVE-2023-40898"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20712"
},
{
"date": "2023-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2023-40898"
},
{
"date": "2024-01-24T01:45:00",
"db": "JVNDB",
"id": "JVNDB-2023-022707"
},
{
"date": "2025-12-08T13:14:17.633000",
"db": "NVD",
"id": "CVE-2023-40898"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac8v4\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-022707"
}
],
"trust": 0.8
}
}
VAR-202306-0114
Vulnerability from variot - Updated: 2025-09-08 23:15Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function. Shenzhen Tenda Technology Co.,Ltd. of AC8 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (one WAN port and three LAN ports), meeting broadband access needs between 100 and 1000 Mbps. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202306-0114",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8 firmware 16.03.34.06"
},
{
"model": "ac8",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.03.34.06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20718"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007625"
},
{
"db": "NVD",
"id": "CVE-2023-33670"
}
]
},
"cve": "CVE-2023-33670",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20718",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-33670",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-33670",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-33670",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2023-33670",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-33670",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-20718",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202306-141",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20718"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-141"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007625"
},
{
"db": "NVD",
"id": "CVE-2023-33670"
},
{
"db": "NVD",
"id": "CVE-2023-33670"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function. Shenzhen Tenda Technology Co.,Ltd. of AC8 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (one WAN port and three LAN ports), meeting broadband access needs between 100 and 1000 Mbps. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-33670"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007625"
},
{
"db": "CNVD",
"id": "CNVD-2025-20718"
},
{
"db": "VULMON",
"id": "CVE-2023-33670"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-33670",
"trust": 3.9
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007625",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20718",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202306-141",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-33670",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20718"
},
{
"db": "VULMON",
"id": "CVE-2023-33670"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-141"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007625"
},
{
"db": "NVD",
"id": "CVE-2023-33670"
}
]
},
"id": "VAR-202306-0114",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20718"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20718"
}
]
},
"last_update_date": "2025-09-08T23:15:58.567000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-007625"
},
{
"db": "NVD",
"id": "CVE-2023-33670"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "https://github.com/ddizzzy79/tenda-cve/blob/main/ac8v4.0/n3/readme.md"
},
{
"trust": 2.4,
"url": "https://github.com/ddizzzy79/tenda-cve/tree/main/ac8v4.0/n3"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-33670"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-33670/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20718"
},
{
"db": "VULMON",
"id": "CVE-2023-33670"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-141"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007625"
},
{
"db": "NVD",
"id": "CVE-2023-33670"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20718"
},
{
"db": "VULMON",
"id": "CVE-2023-33670"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-141"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007625"
},
{
"db": "NVD",
"id": "CVE-2023-33670"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20718"
},
{
"date": "2023-06-02T00:00:00",
"db": "VULMON",
"id": "CVE-2023-33670"
},
{
"date": "2023-06-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202306-141"
},
{
"date": "2023-11-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-007625"
},
{
"date": "2023-06-02T20:15:09.563000",
"db": "NVD",
"id": "CVE-2023-33670"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20718"
},
{
"date": "2023-06-02T00:00:00",
"db": "VULMON",
"id": "CVE-2023-33670"
},
{
"date": "2023-06-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202306-141"
},
{
"date": "2023-11-24T08:09:00",
"db": "JVNDB",
"id": "JVNDB-2023-007625"
},
{
"date": "2025-01-08T21:15:09.780000",
"db": "NVD",
"id": "CVE-2023-33670"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202306-141"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC8\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-007625"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202306-141"
}
],
"trust": 0.6
}
}
VAR-202306-0116
Vulnerability from variot - Updated: 2025-09-08 23:15Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function. Shenzhen Tenda Technology Co.,Ltd. of AC8 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (one WAN port and three LAN ports), meeting broadband access needs between 100 and 1000 Mbps. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202306-0116",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8 firmware 16.03.34.06"
},
{
"model": "ac8",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.03.34.06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20717"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007621"
},
{
"db": "NVD",
"id": "CVE-2023-33675"
}
]
},
"cve": "CVE-2023-33675",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-20717",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-33675",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-33675",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-33675",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2023-33675",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-33675",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-20717",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202306-138",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20717"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-138"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007621"
},
{
"db": "NVD",
"id": "CVE-2023-33675"
},
{
"db": "NVD",
"id": "CVE-2023-33675"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function. Shenzhen Tenda Technology Co.,Ltd. of AC8 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC8 is a dual-band gigabit wireless router designed for homes with fiber optic connections up to 1000 Mbps. It supports dual-band concurrent transmission rates of up to 1167 Mbps and is equipped with full gigabit ports (one WAN port and three LAN ports), meeting broadband access needs between 100 and 1000 Mbps. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-33675"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007621"
},
{
"db": "CNVD",
"id": "CNVD-2025-20717"
},
{
"db": "VULMON",
"id": "CVE-2023-33675"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-33675",
"trust": 3.9
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007621",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-20717",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202306-138",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-33675",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20717"
},
{
"db": "VULMON",
"id": "CVE-2023-33675"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-138"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007621"
},
{
"db": "NVD",
"id": "CVE-2023-33675"
}
]
},
"id": "VAR-202306-0116",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20717"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20717"
}
]
},
"last_update_date": "2025-09-08T23:15:58.538000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-007621"
},
{
"db": "NVD",
"id": "CVE-2023-33675"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "https://github.com/ddizzzy79/tenda-cve/blob/main/ac8v4.0/n5/readme.md"
},
{
"trust": 2.4,
"url": "https://github.com/ddizzzy79/tenda-cve/tree/main/ac8v4.0/n5"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-33675"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-33675/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-20717"
},
{
"db": "VULMON",
"id": "CVE-2023-33675"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-138"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007621"
},
{
"db": "NVD",
"id": "CVE-2023-33675"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-20717"
},
{
"db": "VULMON",
"id": "CVE-2023-33675"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-138"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-007621"
},
{
"db": "NVD",
"id": "CVE-2023-33675"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20717"
},
{
"date": "2023-06-02T00:00:00",
"db": "VULMON",
"id": "CVE-2023-33675"
},
{
"date": "2023-06-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202306-138"
},
{
"date": "2023-11-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-007621"
},
{
"date": "2023-06-02T20:15:09.733000",
"db": "NVD",
"id": "CVE-2023-33675"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-20717"
},
{
"date": "2023-06-02T00:00:00",
"db": "VULMON",
"id": "CVE-2023-33675"
},
{
"date": "2023-06-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202306-138"
},
{
"date": "2023-11-24T08:09:00",
"db": "JVNDB",
"id": "JVNDB-2023-007621"
},
{
"date": "2025-01-08T21:15:10.757000",
"db": "NVD",
"id": "CVE-2023-33675"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202306-138"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC8\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-007621"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202306-138"
}
],
"trust": 0.6
}
}
VAR-202507-2845
Vulnerability from variot - Updated: 2025-08-02 23:18Tenda AC8V4 V16.03.34.06was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argumenttimeZoneandtimeType` leads to stack-based buffer overflow. Shenzhen Tenda Technology Co.,Ltd. An attacker could exploit this vulnerability to cause the application to crash
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202507-2845",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8 firmware 16.03.34.06"
},
{
"model": "ac8",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v16.03.34.06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17345"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010132"
},
{
"db": "NVD",
"id": "CVE-2025-51085"
}
]
},
"cve": "CVE-2025-51085",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-17345",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2025-51085",
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "Low",
"baseScore": 5.3,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2025-010132",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-51085",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2025-010132",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2025-17345",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17345"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010132"
},
{
"db": "NVD",
"id": "CVE-2025-51085"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argument `timeZone` and `timeType` leads to stack-based buffer overflow. Shenzhen Tenda Technology Co.,Ltd. An attacker could exploit this vulnerability to cause the application to crash",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-51085"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010132"
},
{
"db": "CNVD",
"id": "CNVD-2025-17345"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-51085",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010132",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-17345",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17345"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010132"
},
{
"db": "NVD",
"id": "CVE-2025-51085"
}
]
},
"id": "VAR-202507-2845",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17345"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17345"
}
]
},
"last_update_date": "2025-08-02T23:18:47.702000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC8V4 Buffer Overflow Vulnerability (CNVD-2025-17345)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/714496"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17345"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-010132"
},
{
"db": "NVD",
"id": "CVE-2025-51085"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/tl-sn/iot/blob/main/tenda/tenda-ac8v4%20%20v16.03.34.06/cve-2025-51085.md"
},
{
"trust": 1.8,
"url": "http://tenda.com"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-51085"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17345"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010132"
},
{
"db": "NVD",
"id": "CVE-2025-51085"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-17345"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010132"
},
{
"db": "NVD",
"id": "CVE-2025-51085"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-31T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17345"
},
{
"date": "2025-07-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-010132"
},
{
"date": "2025-07-24T15:15:26.577000",
"db": "NVD",
"id": "CVE-2025-51085"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17345"
},
{
"date": "2025-07-29T05:48:00",
"db": "JVNDB",
"id": "JVNDB-2025-010132"
},
{
"date": "2025-07-28T17:01:51.990000",
"db": "NVD",
"id": "CVE-2025-51085"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC8\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-010132"
}
],
"trust": 0.8
}
}
VAR-202507-2780
Vulnerability from variot - Updated: 2025-08-02 23:15Tenda AC8V4 V16.03.34.06was discovered to contain heap overflow at /goform/GetParentControlInfo.The manipulation of the argumentmac` leads to heap-based buffer overflow. The Tenda AC8V4 is a wireless router from the Chinese company Tenda. An attacker could exploit this vulnerability to corrupt memory, causing a system crash and disrupting service operations
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202507-2780",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.03.34.06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17342"
},
{
"db": "NVD",
"id": "CVE-2025-51089"
}
]
},
"cve": "CVE-2025-51089",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.4,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-17342",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2025-51089",
"impactScore": 2.5,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-51089",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2025-17342",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17342"
},
{
"db": "NVD",
"id": "CVE-2025-51089"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4 V16.03.34.06` was discovered to contain heap overflow at /goform/GetParentControlInfo.The manipulation of the argument `mac` leads to heap-based buffer overflow. The Tenda AC8V4 is a wireless router from the Chinese company Tenda. An attacker could exploit this vulnerability to corrupt memory, causing a system crash and disrupting service operations",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-51089"
},
{
"db": "CNVD",
"id": "CNVD-2025-17342"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-51089",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2025-17342",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17342"
},
{
"db": "NVD",
"id": "CVE-2025-51089"
}
]
},
"id": "VAR-202507-2780",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17342"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17342"
}
]
},
"last_update_date": "2025-08-02T23:15:20.798000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC8V4 Buffer Overflow Vulnerability (CNVD-2025-17342)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/714481"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17342"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-122",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2025-51089"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://github.com/tl-sn/iot/blob/main/tenda/tenda-ac8v4%20%20v16.03.34.06/cve-2025-51089.md"
},
{
"trust": 1.0,
"url": "http://tenda.com"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-51089"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17342"
},
{
"db": "NVD",
"id": "CVE-2025-51089"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-17342"
},
{
"db": "NVD",
"id": "CVE-2025-51089"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-31T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17342"
},
{
"date": "2025-07-24T15:15:26.993000",
"db": "NVD",
"id": "CVE-2025-51089"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17342"
},
{
"date": "2025-07-28T17:04:40.397000",
"db": "NVD",
"id": "CVE-2025-51089"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4 Buffer Overflow Vulnerability (CNVD-2025-17342)",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17342"
}
],
"trust": 0.6
}
}
VAR-202507-2844
Vulnerability from variot - Updated: 2025-08-02 23:14Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The Tenda AC8V4 is a wireless router manufactured by the Chinese company Tenda. Detailed vulnerability details are not currently available
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202507-2844",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v16.03.34.06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17346"
},
{
"db": "NVD",
"id": "CVE-2025-51087"
}
]
},
"cve": "CVE-2025-51087",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-17346",
"impactScore": 8.5,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "LOW",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-51087",
"impactScore": 4.7,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-51087",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2025-17346",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17346"
},
{
"db": "NVD",
"id": "CVE-2025-51087"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The Tenda AC8V4 is a wireless router manufactured by the Chinese company Tenda. Detailed vulnerability details are not currently available",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-51087"
},
{
"db": "CNVD",
"id": "CNVD-2025-17346"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-51087",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2025-17346",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17346"
},
{
"db": "NVD",
"id": "CVE-2025-51087"
}
]
},
"id": "VAR-202507-2844",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17346"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17346"
}
]
},
"last_update_date": "2025-08-02T23:14:06.429000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC8V4 Buffer Overflow Vulnerability (CNVD-2025-17346)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/714476"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17346"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2025-51087"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://github.com/tl-sn/iot/blob/main/tenda/tenda-ac8v4%20%20v16.03.34.06/cve-2025-51087.md"
},
{
"trust": 1.0,
"url": "http://tenda.com"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17346"
},
{
"db": "NVD",
"id": "CVE-2025-51087"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-17346"
},
{
"db": "NVD",
"id": "CVE-2025-51087"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-31T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17346"
},
{
"date": "2025-07-24T15:15:26.693000",
"db": "NVD",
"id": "CVE-2025-51087"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17346"
},
{
"date": "2025-07-28T17:02:56.940000",
"db": "NVD",
"id": "CVE-2025-51087"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4 Buffer Overflow Vulnerability (CNVD-2025-17346)",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17346"
}
],
"trust": 0.6
}
}
VAR-202507-2753
Vulnerability from variot - Updated: 2025-08-02 23:04Tenda AC8V4 V16.03.34.06was discovered to contain stack overflow at /goform/WifiGuestSet. The manipulation of the argumentshareSpeed` leads to stack-based buffer overflow. The Tenda AC8V4 is a wireless router from the Chinese company Tenda. Detailed vulnerability details are currently unavailable
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202507-2753",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.03.34.06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17343"
},
{
"db": "NVD",
"id": "CVE-2025-51088"
}
]
},
"cve": "CVE-2025-51088",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-17343",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2025-51088",
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-51088",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2025-17343",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17343"
},
{
"db": "NVD",
"id": "CVE-2025-51088"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/WifiGuestSet. The manipulation of the argument `shareSpeed` leads to stack-based buffer overflow. The Tenda AC8V4 is a wireless router from the Chinese company Tenda. Detailed vulnerability details are currently unavailable",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-51088"
},
{
"db": "CNVD",
"id": "CNVD-2025-17343"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-51088",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2025-17343",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17343"
},
{
"db": "NVD",
"id": "CVE-2025-51088"
}
]
},
"id": "VAR-202507-2753",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17343"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17343"
}
]
},
"last_update_date": "2025-08-02T23:04:33.335000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC8V4 Buffer Overflow Vulnerability (CNVD-2025-17343)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/714486"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17343"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2025-51088"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "http://tenda.com"
},
{
"trust": 1.0,
"url": "https://github.com/tl-sn/iot/blob/main/tenda/tenda-ac8v4%20%20v16.03.34.06/cve-2025-51088.md"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-51088"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17343"
},
{
"db": "NVD",
"id": "CVE-2025-51088"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-17343"
},
{
"db": "NVD",
"id": "CVE-2025-51088"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-31T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17343"
},
{
"date": "2025-07-24T15:15:26.877000",
"db": "NVD",
"id": "CVE-2025-51088"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17343"
},
{
"date": "2025-07-28T17:04:02.997000",
"db": "NVD",
"id": "CVE-2025-51088"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4 Buffer Overflow Vulnerability (CNVD-2025-17343)",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17343"
}
],
"trust": 0.6
}
}
VAR-202507-2846
Vulnerability from variot - Updated: 2025-08-02 22:57Tenda AC8V4 V16.03.34.06was discovered to contain stack overflow at /goform/fast_setting_wifi_set. The manipulation of the argumenttimeZone` leads to stack-based buffer overflow. Shenzhen Tenda Technology Co.,Ltd. Detailed vulnerability details are not currently available
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202507-2846",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8 firmware 16.03.34.06"
},
{
"model": "ac8",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "16.03.34.06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17344"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010133"
},
{
"db": "NVD",
"id": "CVE-2025-51082"
}
]
},
"cve": "CVE-2025-51082",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-17344",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2025-51082",
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "Low",
"baseScore": 5.3,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2025-010133",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-51082",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2025-010133",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2025-17344",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17344"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010133"
},
{
"db": "NVD",
"id": "CVE-2025-51082"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/fast_setting_wifi_set. The manipulation of the argument `timeZone` leads to stack-based buffer overflow. Shenzhen Tenda Technology Co.,Ltd. Detailed vulnerability details are not currently available",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-51082"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010133"
},
{
"db": "CNVD",
"id": "CNVD-2025-17344"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-51082",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010133",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-17344",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17344"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010133"
},
{
"db": "NVD",
"id": "CVE-2025-51082"
}
]
},
"id": "VAR-202507-2846",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17344"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17344"
}
]
},
"last_update_date": "2025-08-02T22:57:03.303000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC8V4 Buffer Overflow Vulnerability (CNVD-2025-17344)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/714491"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17344"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-010133"
},
{
"db": "NVD",
"id": "CVE-2025-51082"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "http://tenda.com"
},
{
"trust": 1.8,
"url": "https://github.com/tl-sn/iot/blob/main/tenda/tenda-ac8v4%20%20v16.03.34.06/cve-2025-51082.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-51082"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17344"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010133"
},
{
"db": "NVD",
"id": "CVE-2025-51082"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-17344"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-010133"
},
{
"db": "NVD",
"id": "CVE-2025-51082"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-31T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17344"
},
{
"date": "2025-07-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-010133"
},
{
"date": "2025-07-24T15:15:26.453000",
"db": "NVD",
"id": "CVE-2025-51082"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17344"
},
{
"date": "2025-07-29T05:48:00",
"db": "JVNDB",
"id": "JVNDB-2025-010133"
},
{
"date": "2025-07-28T17:00:35.920000",
"db": "NVD",
"id": "CVE-2025-51082"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC8\u00a0 Stack-based buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-010133"
}
],
"trust": 0.8
}
}
VAR-202409-1458
Vulnerability from variot - Updated: 2025-03-28 02:25Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function. Shenzhen Tenda Technology Co.,Ltd. of AC8 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202409-1458",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8 firmware 16.03.34.06"
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v16.03.34.06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39363"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020818"
},
{
"db": "NVD",
"id": "CVE-2024-46652"
}
]
},
"cve": "CVE-2024-46652",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-39363",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2024-46652",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2024-46652",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2024-46652",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-46652",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2024-46652",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2024-39363",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39363"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020818"
},
{
"db": "NVD",
"id": "CVE-2024-46652"
},
{
"db": "NVD",
"id": "CVE-2024-46652"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function. Shenzhen Tenda Technology Co.,Ltd. of AC8 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-46652"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020818"
},
{
"db": "CNVD",
"id": "CNVD-2024-39363"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-46652",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020818",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-39363",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39363"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020818"
},
{
"db": "NVD",
"id": "CVE-2024-46652"
}
]
},
"id": "VAR-202409-1458",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39363"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39363"
}
]
},
"last_update_date": "2025-03-28T02:25:04.978000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020818"
},
{
"db": "NVD",
"id": "CVE-2024-46652"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/zp9080/tenda/blob/main/tenda-ac8v4%20v16.03.34.06-fromadvsetmacmtuwan/overview.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-46652"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39363"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020818"
},
{
"db": "NVD",
"id": "CVE-2024-46652"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-39363"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020818"
},
{
"db": "NVD",
"id": "CVE-2024-46652"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-09-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-39363"
},
{
"date": "2025-03-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020818"
},
{
"date": "2024-09-20T16:15:05.063000",
"db": "NVD",
"id": "CVE-2024-46652"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-09-27T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-39363"
},
{
"date": "2025-03-24T09:36:00",
"db": "JVNDB",
"id": "JVNDB-2024-020818"
},
{
"date": "2025-03-17T15:00:28.117000",
"db": "NVD",
"id": "CVE-2024-46652"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC8\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020818"
}
],
"trust": 0.8
}
}
VAR-202502-2733
Vulnerability from variot - Updated: 2025-03-20 23:22Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function. Shenzhen Tenda Technology Co.,Ltd. of AC8 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can exploit this vulnerability to corrupt memory and possibly cause the browser to crash
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202502-2733",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac8 firmware 16.03.34.06"
},
{
"model": "ac8",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8v4",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v16.03.34.06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05398"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002426"
},
{
"db": "NVD",
"id": "CVE-2025-25664"
}
]
},
"cve": "CVE-2025-25664",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-05398",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-25664",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2025-25664",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2025-25664",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-25664",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2025-25664",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-05398",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05398"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002426"
},
{
"db": "NVD",
"id": "CVE-2025-25664"
},
{
"db": "NVD",
"id": "CVE-2025-25664"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function. Shenzhen Tenda Technology Co.,Ltd. of AC8 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can exploit this vulnerability to corrupt memory and possibly cause the browser to crash",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-25664"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002426"
},
{
"db": "CNVD",
"id": "CNVD-2025-05398"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-25664",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002426",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-05398",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05398"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002426"
},
{
"db": "NVD",
"id": "CVE-2025-25664"
}
]
},
"id": "VAR-202502-2733",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05398"
}
],
"trust": 0.88088236
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05398"
}
]
},
"last_update_date": "2025-03-20T23:22:25.176000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-002426"
},
{
"db": "NVD",
"id": "CVE-2025-25664"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-25664"
},
{
"trust": 1.0,
"url": "https://github.com/jangfan/my-vuln/blob/main/tenda/ac8v4/setipmacbind.md"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-05398"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002426"
},
{
"db": "NVD",
"id": "CVE-2025-25664"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-05398"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-002426"
},
{
"db": "NVD",
"id": "CVE-2025-25664"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-05398"
},
{
"date": "2025-03-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-002426"
},
{
"date": "2025-02-20T23:15:12.453000",
"db": "NVD",
"id": "CVE-2025-25664"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-05398"
},
{
"date": "2025-03-18T07:43:00",
"db": "JVNDB",
"id": "JVNDB-2025-002426"
},
{
"date": "2025-03-17T15:19:50.133000",
"db": "NVD",
"id": "CVE-2025-25664"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC8\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-002426"
}
],