Search criteria
8 vulnerabilities found for ac6 by tendacn
VAR-202212-0076
Vulnerability from variot - Updated: 2025-11-19 23:31Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the ssid parameter in the form_fast_setting_wifi_set function. The Tenda AC6 is a dual-band wireless router from Tenda, supporting both 2.4GHz and 5GHz bands and achieving a maximum transmission rate of 1167Mbps. An attacker could exploit this vulnerability to cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0076",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "15.03.05.19"
},
{
"model": "ac6",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "15.03.05.19"
},
{
"model": "ac6",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24493"
},
{
"db": "NVD",
"id": "CVE-2022-45654"
}
]
},
"cve": "CVE-2022-45654",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-24493",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45654",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45654",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45654",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2025-24493",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-1887",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24493"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-1887"
},
{
"db": "NVD",
"id": "CVE-2022-45654"
},
{
"db": "NVD",
"id": "CVE-2022-45654"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the ssid parameter in the form_fast_setting_wifi_set function. The Tenda AC6 is a dual-band wireless router from Tenda, supporting both 2.4GHz and 5GHz bands and achieving a maximum transmission rate of 1167Mbps. An attacker could exploit this vulnerability to cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45654"
},
{
"db": "CNVD",
"id": "CNVD-2025-24493"
},
{
"db": "VULMON",
"id": "CVE-2022-45654"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45654",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2025-24493",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202212-1887",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-45654",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24493"
},
{
"db": "VULMON",
"id": "CVE-2022-45654"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-1887"
},
{
"db": "NVD",
"id": "CVE-2022-45654"
}
]
},
"id": "VAR-202212-0076",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24493"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24493"
}
]
},
"last_update_date": "2025-11-19T23:31:00.748000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45654"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://github.com/double-q1015/cve-vulns/blob/main/tenda_ac6/form_fast_setting_wifi_set_ssid/form_fast_setting_wifi_set_ssid.md"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45654/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24493"
},
{
"db": "VULMON",
"id": "CVE-2022-45654"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-1887"
},
{
"db": "NVD",
"id": "CVE-2022-45654"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-24493"
},
{
"db": "VULMON",
"id": "CVE-2022-45654"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-1887"
},
{
"db": "NVD",
"id": "CVE-2022-45654"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-10-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-24493"
},
{
"date": "2022-12-02T00:00:00",
"db": "VULMON",
"id": "CVE-2022-45654"
},
{
"date": "2022-12-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-1887"
},
{
"date": "2022-12-02T18:15:11.533000",
"db": "NVD",
"id": "CVE-2022-45654"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-10-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-24493"
},
{
"date": "2022-12-02T00:00:00",
"db": "VULMON",
"id": "CVE-2022-45654"
},
{
"date": "2022-12-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-1887"
},
{
"date": "2025-04-24T14:15:43.543000",
"db": "NVD",
"id": "CVE-2022-45654"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-1887"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC6 form_fast_setting_wifi_set function buffer overflow vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24493"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-1887"
}
],
"trust": 0.6
}
}
VAR-202212-0070
Vulnerability from variot - Updated: 2025-11-19 23:07Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the timeZone parameter in the form_fast_setting_wifi_set function. The Tenda AC6 is a dual-band wireless router from Tenda, supporting both 2.4GHz and 5GHz bands and achieving a maximum transmission rate of 1167Mbps. An attacker could exploit this vulnerability to cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202212-0070",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "15.03.05.19"
},
{
"model": "ac6",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "15.03.05.19"
},
{
"model": "ac6",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24494"
},
{
"db": "NVD",
"id": "CVE-2022-45655"
}
]
},
"cve": "CVE-2022-45655",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-24494",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-45655",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-45655",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2022-45655",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2025-24494",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202212-1889",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24494"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-1889"
},
{
"db": "NVD",
"id": "CVE-2022-45655"
},
{
"db": "NVD",
"id": "CVE-2022-45655"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the timeZone parameter in the form_fast_setting_wifi_set function. The Tenda AC6 is a dual-band wireless router from Tenda, supporting both 2.4GHz and 5GHz bands and achieving a maximum transmission rate of 1167Mbps. An attacker could exploit this vulnerability to cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45655"
},
{
"db": "CNVD",
"id": "CNVD-2025-24494"
},
{
"db": "VULMON",
"id": "CVE-2022-45655"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-45655",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2025-24494",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202212-1889",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-45655",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24494"
},
{
"db": "VULMON",
"id": "CVE-2022-45655"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-1889"
},
{
"db": "NVD",
"id": "CVE-2022-45655"
}
]
},
"id": "VAR-202212-0070",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24494"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24494"
}
]
},
"last_update_date": "2025-11-19T23:07:14.816000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-45655"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://github.com/double-q1015/cve-vulns/blob/main/tenda_ac6/form_fast_setting_wifi_set_timezone/form_fast_setting_wifi_set_timezone.md"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-45655/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24494"
},
{
"db": "VULMON",
"id": "CVE-2022-45655"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-1889"
},
{
"db": "NVD",
"id": "CVE-2022-45655"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-24494"
},
{
"db": "VULMON",
"id": "CVE-2022-45655"
},
{
"db": "CNNVD",
"id": "CNNVD-202212-1889"
},
{
"db": "NVD",
"id": "CVE-2022-45655"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-10-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-24494"
},
{
"date": "2022-12-02T00:00:00",
"db": "VULMON",
"id": "CVE-2022-45655"
},
{
"date": "2022-12-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-1889"
},
{
"date": "2022-12-02T18:15:11.603000",
"db": "NVD",
"id": "CVE-2022-45655"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-10-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-24494"
},
{
"date": "2022-12-02T00:00:00",
"db": "VULMON",
"id": "CVE-2022-45655"
},
{
"date": "2022-12-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202212-1889"
},
{
"date": "2025-04-24T14:15:43.717000",
"db": "NVD",
"id": "CVE-2022-45655"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-1889"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC6 form_fast_setting_wifi_set function buffer overflow vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-24494"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202212-1889"
}
],
"trust": 0.6
}
}
VAR-202005-0460
Vulnerability from variot - Updated: 2024-11-23 22:58An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/SetNetControlList list parameter for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202005-0460",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.06.42_multi"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19_multi_td01"
},
{
"model": "ac18",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)"
},
{
"model": "ac15",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19_multi_td01"
},
{
"model": "ac15",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac18",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6 v15.03.05.19 multi td01",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0v15.03.05.19(6318)"
},
{
"model": "ac9 v15.03.06.42 multi",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v3.0"
},
{
"model": "ac15 v15.03.05.19 multi td01",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac18",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v15.03.05.19(6318)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31409"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005748"
},
{
"db": "NVD",
"id": "CVE-2020-13394"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tendacn:ac6_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005748"
}
]
},
"cve": "CVE-2020-13394",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-13394",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-005748",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-31409",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2020-13394",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-005748",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2020-13394",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-005748",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2020-31409",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202005-1144",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31409"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005748"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1144"
},
{
"db": "NVD",
"id": "CVE-2020-13394"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/SetNetControlList list parameter for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13394"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005748"
},
{
"db": "CNVD",
"id": "CNVD-2020-31409"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-13394",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005748",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-31409",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1144",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31409"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005748"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1144"
},
{
"db": "NVD",
"id": "CVE-2020-13394"
}
]
},
"id": "VAR-202005-0460",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31409"
}
],
"trust": 1.3076761016666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31409"
}
]
},
"last_update_date": "2024-11-23T22:58:17.264000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://tendacn.com/en"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005748"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005748"
},
{
"db": "NVD",
"id": "CVE-2020-13394"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13394-tenda-vulnerability/"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-13394"
},
{
"trust": 1.6,
"url": "https://joel-malwarebenchmark.github.io"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13394"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31409"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005748"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1144"
},
{
"db": "NVD",
"id": "CVE-2020-13394"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-31409"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005748"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1144"
},
{
"db": "NVD",
"id": "CVE-2020-13394"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-06-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-31409"
},
{
"date": "2020-06-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-005748"
},
{
"date": "2020-05-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-1144"
},
{
"date": "2020-05-22T17:15:11.363000",
"db": "NVD",
"id": "CVE-2020-13394"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-06-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-31409"
},
{
"date": "2020-06-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-005748"
},
{
"date": "2020-05-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-1144"
},
{
"date": "2024-11-21T05:01:10.413000",
"db": "NVD",
"id": "CVE-2020-13394"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-1144"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Tenda Classic buffer overflow vulnerability in device",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005748"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-1144"
}
],
"trust": 0.6
}
}
VAR-202005-0459
Vulnerability from variot - Updated: 2024-11-23 22:51An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/saveParentControlInfo deviceId and time parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202005-0459",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.06.42_multi"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19_multi_td01"
},
{
"model": "ac18",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)"
},
{
"model": "ac15",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19_multi_td01"
},
{
"model": "ac15",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac18",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6 v15.03.05.19 multi td01",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac9 v15.03.06.42 multi",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v3.0"
},
{
"model": "ac15 v15.03.05.19 multi td01",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac9 v15.03.05.19 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac18 ) cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v15.03.05.19(6318"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31408"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005747"
},
{
"db": "NVD",
"id": "CVE-2020-13393"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tendacn:ac6_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005747"
}
]
},
"cve": "CVE-2020-13393",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-13393",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-005747",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-31408",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2020-13393",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-005747",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2020-13393",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-005747",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2020-31408",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202005-1143",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31408"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005747"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1143"
},
{
"db": "NVD",
"id": "CVE-2020-13393"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/saveParentControlInfo deviceId and time parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13393"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005747"
},
{
"db": "CNVD",
"id": "CNVD-2020-31408"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-13393",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005747",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-31408",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1143",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31408"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005747"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1143"
},
{
"db": "NVD",
"id": "CVE-2020-13393"
}
]
},
"id": "VAR-202005-0459",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31408"
}
],
"trust": 1.38075707625
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31408"
}
]
},
"last_update_date": "2024-11-23T22:51:21.819000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://tendacn.com/en"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005747"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005747"
},
{
"db": "NVD",
"id": "CVE-2020-13393"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13393-tenda-vulnerability/"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-13393"
},
{
"trust": 1.0,
"url": "https://joel-malwarebenchmark.github.io"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13393"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31408"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005747"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1143"
},
{
"db": "NVD",
"id": "CVE-2020-13393"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-31408"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005747"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1143"
},
{
"db": "NVD",
"id": "CVE-2020-13393"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-06-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-31408"
},
{
"date": "2020-06-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-005747"
},
{
"date": "2020-05-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-1143"
},
{
"date": "2020-05-22T17:15:11.300000",
"db": "NVD",
"id": "CVE-2020-13393"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-06-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-31408"
},
{
"date": "2020-06-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-005747"
},
{
"date": "2020-05-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-1143"
},
{
"date": "2024-11-21T05:01:10.260000",
"db": "NVD",
"id": "CVE-2020-13393"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-1143"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Tenda Classic buffer overflow vulnerability in device",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005747"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-1143"
}
],
"trust": 0.6
}
}
VAR-202005-0455
Vulnerability from variot - Updated: 2024-11-23 22:48An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/openSchedWifi schedStartTime and schedEndTime parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202005-0455",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.06.42_multi"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19_multi_td01"
},
{
"model": "ac18",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)"
},
{
"model": "ac15",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19_multi_td01"
},
{
"model": "ac15",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "v1.0 15.03.05.19_multi_td01"
},
{
"model": "ac18",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "15.03.05.19(6318_)_cn"
},
{
"model": "ac6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "v1.0 15.03.05.19_multi_td01"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "v1.0 15.03.05.19(6318)_cn"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "v3.0 15.03.06.42_multi"
},
{
"model": "ac6 v15.03.05.19 multi td01",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0v15.03.05.19(6318)"
},
{
"model": "ac9 v15.03.06.42 multi",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v3.0"
},
{
"model": "ac15 v15.03.05.19 multi td01",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac18",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v15.03.05.19(6318)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31386"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005757"
},
{
"db": "NVD",
"id": "CVE-2020-13389"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:tenda:ac15_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tenda:ac18_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tenda:ac6_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tenda:ac9_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005757"
}
]
},
"cve": "CVE-2020-13389",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-13389",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 1.1,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-005757",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-31386",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2020-13389",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-005757",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2020-13389",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-005757",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2020-31386",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202005-1139",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-13389",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31386"
},
{
"db": "VULMON",
"id": "CVE-2020-13389"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005757"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1139"
},
{
"db": "NVD",
"id": "CVE-2020-13389"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/openSchedWifi schedStartTime and schedEndTime parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13389"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005757"
},
{
"db": "CNVD",
"id": "CNVD-2020-31386"
},
{
"db": "VULMON",
"id": "CVE-2020-13389"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-13389",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005757",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-31386",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1139",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-13389",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31386"
},
{
"db": "VULMON",
"id": "CVE-2020-13389"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005757"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1139"
},
{
"db": "NVD",
"id": "CVE-2020-13389"
}
]
},
"id": "VAR-202005-0455",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31386"
}
],
"trust": 1.3076761016666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31386"
}
]
},
"last_update_date": "2024-11-23T22:48:00.116000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.tenda.com.cn/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005757"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005757"
},
{
"db": "NVD",
"id": "CVE-2020-13389"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13389-tenda-vulnerability/"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-13389"
},
{
"trust": 1.7,
"url": "https://joel-malwarebenchmark.github.io"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13389"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/120.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31386"
},
{
"db": "VULMON",
"id": "CVE-2020-13389"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005757"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1139"
},
{
"db": "NVD",
"id": "CVE-2020-13389"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-31386"
},
{
"db": "VULMON",
"id": "CVE-2020-13389"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005757"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1139"
},
{
"db": "NVD",
"id": "CVE-2020-13389"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-06-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-31386"
},
{
"date": "2020-05-22T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13389"
},
{
"date": "2020-06-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-005757"
},
{
"date": "2020-05-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-1139"
},
{
"date": "2020-05-22T17:15:11.033000",
"db": "NVD",
"id": "CVE-2020-13389"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-06-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-31386"
},
{
"date": "2020-05-27T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13389"
},
{
"date": "2020-06-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-005757"
},
{
"date": "2020-05-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-1139"
},
{
"date": "2024-11-21T05:01:09.660000",
"db": "NVD",
"id": "CVE-2020-13389"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-1139"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Tenda Classic buffer overflow vulnerability in device",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005757"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-1139"
}
],
"trust": 0.6
}
}
VAR-202005-0457
Vulnerability from variot - Updated: 2024-11-23 22:41An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/SetSpeedWan speed_dir parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202005-0457",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.06.42_multi"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19_multi_td01"
},
{
"model": "ac18",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)"
},
{
"model": "ac15",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19_multi_td01"
},
{
"model": "ac15",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac18",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6 v15.03.05.19 multi td01",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac9 v15.03.06.42 multi",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v3.0"
},
{
"model": "ac15 v15.03.05.19 multi td01",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac9 v15.03.05.19 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac18 ) cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v15.03.05.19(6318"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31397"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005745"
},
{
"db": "NVD",
"id": "CVE-2020-13391"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tendacn:ac6_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005745"
}
]
},
"cve": "CVE-2020-13391",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-13391",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 1.1,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-005745",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-31397",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2020-13391",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-005745",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2020-13391",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-005745",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2020-31397",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202005-1141",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-13391",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31397"
},
{
"db": "VULMON",
"id": "CVE-2020-13391"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005745"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1141"
},
{
"db": "NVD",
"id": "CVE-2020-13391"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/SetSpeedWan speed_dir parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13391"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005745"
},
{
"db": "CNVD",
"id": "CNVD-2020-31397"
},
{
"db": "VULMON",
"id": "CVE-2020-13391"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-13391",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005745",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-31397",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1141",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-13391",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31397"
},
{
"db": "VULMON",
"id": "CVE-2020-13391"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005745"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1141"
},
{
"db": "NVD",
"id": "CVE-2020-13391"
}
]
},
"id": "VAR-202005-0457",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31397"
}
],
"trust": 1.38075707625
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31397"
}
]
},
"last_update_date": "2024-11-23T22:41:05.729000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://tendacn.com/en"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005745"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005745"
},
{
"db": "NVD",
"id": "CVE-2020-13391"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13391-tenda-vulnerability/"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-13391"
},
{
"trust": 1.7,
"url": "https://joel-malwarebenchmark.github.io"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13391"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/120.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31397"
},
{
"db": "VULMON",
"id": "CVE-2020-13391"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005745"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1141"
},
{
"db": "NVD",
"id": "CVE-2020-13391"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-31397"
},
{
"db": "VULMON",
"id": "CVE-2020-13391"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005745"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1141"
},
{
"db": "NVD",
"id": "CVE-2020-13391"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-06-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-31397"
},
{
"date": "2020-05-22T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13391"
},
{
"date": "2020-06-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-005745"
},
{
"date": "2020-05-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-1141"
},
{
"date": "2020-05-22T17:15:11.177000",
"db": "NVD",
"id": "CVE-2020-13391"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-06-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-31397"
},
{
"date": "2020-05-27T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13391"
},
{
"date": "2020-06-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-005745"
},
{
"date": "2020-05-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-1141"
},
{
"date": "2024-11-21T05:01:09.953000",
"db": "NVD",
"id": "CVE-2020-13391"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-1141"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Tenda Classic buffer overflow vulnerability in device",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005745"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-1141"
}
],
"trust": 0.6
}
}
VAR-202005-0456
Vulnerability from variot - Updated: 2024-11-23 22:29An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/addressNat entrys and mitInterface parameters for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202005-0456",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.06.42_multi"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19_multi_td01"
},
{
"model": "ac18",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)"
},
{
"model": "ac15",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19_multi_td01"
},
{
"model": "ac15",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "v1.0 15.03.05.19_multi_td01"
},
{
"model": "ac18",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "15.03.05.19(6318_)_cn"
},
{
"model": "ac6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "v1.0 15.03.05.19_multi_td01"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "v1.0 15.03.05.19(6318)_cn"
},
{
"model": "ac9",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "v3.0 15.03.06.42_multi"
},
{
"model": "ac6 v15.03.05.19 multi td01",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac9 v15.03.06.42 multi",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v3.0"
},
{
"model": "ac15 v15.03.05.19 multi td01",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac9 v15.03.05.19 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac18 ) cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v15.03.05.19(6318"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31387"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005758"
},
{
"db": "NVD",
"id": "CVE-2020-13390"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:tenda:ac15_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tenda:ac18_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tenda:ac6_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tenda:ac9_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005758"
}
]
},
"cve": "CVE-2020-13390",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-13390",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-005758",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-31387",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2020-13390",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-005758",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2020-13390",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-005758",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2020-31387",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202005-1140",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31387"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005758"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1140"
},
{
"db": "NVD",
"id": "CVE-2020-13390"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/addressNat entrys and mitInterface parameters for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13390"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005758"
},
{
"db": "CNVD",
"id": "CNVD-2020-31387"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-13390",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005758",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-31387",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1140",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31387"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005758"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1140"
},
{
"db": "NVD",
"id": "CVE-2020-13390"
}
]
},
"id": "VAR-202005-0456",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31387"
}
],
"trust": 1.38075707625
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31387"
}
]
},
"last_update_date": "2024-11-23T22:29:37.793000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.tenda.com.cn/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005758"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005758"
},
{
"db": "NVD",
"id": "CVE-2020-13390"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13390-tenda-vulnerability/"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-13390"
},
{
"trust": 1.6,
"url": "https://joel-malwarebenchmark.github.io"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13390"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31387"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005758"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1140"
},
{
"db": "NVD",
"id": "CVE-2020-13390"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-31387"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005758"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1140"
},
{
"db": "NVD",
"id": "CVE-2020-13390"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-06-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-31387"
},
{
"date": "2020-06-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-005758"
},
{
"date": "2020-05-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-1140"
},
{
"date": "2020-05-22T17:15:11.097000",
"db": "NVD",
"id": "CVE-2020-13390"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-06-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-31387"
},
{
"date": "2020-06-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-005758"
},
{
"date": "2020-05-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-1140"
},
{
"date": "2024-11-21T05:01:09.810000",
"db": "NVD",
"id": "CVE-2020-13390"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-1140"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Tenda Classic buffer overflow vulnerability in device",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005758"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-1140"
}
],
"trust": 0.6
}
}
VAR-202005-0458
Vulnerability from variot - Updated: 2024-11-23 22:16An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/setcfm funcpara1 parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202005-0458",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.06.42_multi"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19_multi_td01"
},
{
"model": "ac18",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19\\(6318\\)"
},
{
"model": "ac15",
"scope": "eq",
"trust": 1.0,
"vendor": "tendacn",
"version": "v15.03.05.19_multi_td01"
},
{
"model": "ac15",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac18",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6 v15.03.05.19 multi td01",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac9 v15.03.06.42 multi",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v3.0"
},
{
"model": "ac15 v15.03.05.19 multi td01",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac9 v15.03.05.19 cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.0"
},
{
"model": "ac18 ) cn",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v15.03.05.19(6318"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31407"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005746"
},
{
"db": "NVD",
"id": "CVE-2020-13392"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tendacn:ac6_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005746"
}
]
},
"cve": "CVE-2020-13392",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-13392",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 1.1,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-005746",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-31407",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2020-13392",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-005746",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2020-13392",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-005746",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2020-31407",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202005-1142",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-13392",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31407"
},
{
"db": "VULMON",
"id": "CVE-2020-13392"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005746"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1142"
},
{
"db": "NVD",
"id": "CVE-2020-13392"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/setcfm funcpara1 parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13392"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005746"
},
{
"db": "CNVD",
"id": "CNVD-2020-31407"
},
{
"db": "VULMON",
"id": "CVE-2020-13392"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-13392",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005746",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-31407",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1142",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-13392",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31407"
},
{
"db": "VULMON",
"id": "CVE-2020-13392"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005746"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1142"
},
{
"db": "NVD",
"id": "CVE-2020-13392"
}
]
},
"id": "VAR-202005-0458",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31407"
}
],
"trust": 1.38075707625
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31407"
}
]
},
"last_update_date": "2024-11-23T22:16:28.744000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://tendacn.com/en"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005746"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005746"
},
{
"db": "NVD",
"id": "CVE-2020-13392"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13392-tenda-vulnerability/"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-13392"
},
{
"trust": 1.7,
"url": "https://joel-malwarebenchmark.github.io"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13392"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/120.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-31407"
},
{
"db": "VULMON",
"id": "CVE-2020-13392"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005746"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1142"
},
{
"db": "NVD",
"id": "CVE-2020-13392"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-31407"
},
{
"db": "VULMON",
"id": "CVE-2020-13392"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-005746"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-1142"
},
{
"db": "NVD",
"id": "CVE-2020-13392"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-06-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-31407"
},
{
"date": "2020-05-22T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13392"
},
{
"date": "2020-06-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-005746"
},
{
"date": "2020-05-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-1142"
},
{
"date": "2020-05-22T17:15:11.237000",
"db": "NVD",
"id": "CVE-2020-13392"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-06-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-31407"
},
{
"date": "2020-05-27T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13392"
},
{
"date": "2020-06-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-005746"
},
{
"date": "2020-05-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-1142"
},
{
"date": "2024-11-21T05:01:10.107000",
"db": "NVD",
"id": "CVE-2020-13392"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-1142"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Tenda Classic buffer overflow vulnerability in device",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-005746"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-1142"
}
],
"trust": 0.6
}
}