    Vulnerability from variot - Updated: 2025-10-10 20:27

    A vulnerability has been identified in PowerSys (All versions < V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices. Siemens' PowerSys There is an authentication vulnerability in.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. PowerSys is a service program used for debugging, maintenance and diagnosis of PowerLink 50/100 or SWT 3000 devices

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202406-0183",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "powersys",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "siemens",
            "version": "3.11"
          },
          {
            "model": "powersys",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": "3.11"
          },
          {
            "model": "powersys",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "powersys",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-26702"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028519"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-36266"
          }
        ]
      },
      "cve": "CVE-2024-36266",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2024-26702",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "productcert@siemens.com",
                "availabilityImpact": "HIGH",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.5,
                "id": "CVE-2024-36266",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2024-36266",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2024-36266",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2024-36266",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-36266",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2024-36266",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-26702",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-26702"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028519"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-36266"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-36266"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in PowerSys (All versions \u003c V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices. Siemens\u0027 PowerSys There is an authentication vulnerability in.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. PowerSys is a service program used for debugging, maintenance and diagnosis of PowerLink 50/100 or SWT 3000 devices",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-36266"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028519"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-26702"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-36266",
            "trust": 3.2
          },
          {
            "db": "SIEMENS",
            "id": "SSA-024584",
            "trust": 2.4
          },
          {
            "db": "JVN",
            "id": "JVNVU96920775",
            "trust": 0.8
          },
          {
            "db": "JVN",
            "id": "JVNVU93250330",
            "trust": 0.8
          },
          {
            "db": "JVN",
            "id": "JVNVU99752892",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-24-165-07",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028519",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-26702",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-26702"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028519"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-36266"
          }
        ]
      },
      "id": "VAR-202406-0183",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-26702"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-26702"
          }
        ]
      },
      "last_update_date": "2025-10-10T20:27:52.283000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Siemens PowerSys Authentication Error Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/555071"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-26702"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-287",
            "trust": 1.0
          },
          {
            "problemtype": "Inappropriate authentication (CWE-287) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028519"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-36266"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-024584.html"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu99752892/"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu96920775/"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu93250330/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-36266"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-07"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-26702"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028519"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-36266"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-26702"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028519"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-36266"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-06-11T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-26702"
          },
          {
            "date": "2025-10-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-028519"
          },
          {
            "date": "2024-06-11T12:15:18.657000",
            "db": "NVD",
            "id": "CVE-2024-36266"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-06-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-26702"
          },
          {
            "date": "2025-10-07T05:59:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-028519"
          },
          {
            "date": "2025-09-26T23:52:05.310000",
            "db": "NVD",
            "id": "CVE-2024-36266"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens\u0027 \u00a0PowerSys\u00a0 Authentication vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028519"
          }
        ],
        "trust": 0.8
      }
    }

    CVE-2024-36266 (GCVE-0-2024-36266)

    Vulnerability from nvd – Published: 2024-06-11 11:15 – Updated: 2024-08-02 03:37
    VLAI
    Summary
    A vulnerability has been identified in PowerSys (All versions < V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    Impacted products
    Vendor Product Version
    Siemens PowerSys Affected: 0 , < V3.11 (custom)
    Create a notification for this product.
    siemens powersys Affected: 0 , < 3.11 (custom)
        cpe:2.3:a:siemens:powersys:v3.11:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:powersys:v3.11:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "powersys",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "3.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-36266",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-11T13:11:44.819782Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-11T13:14:45.274Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T03:37:04.767Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-024584.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "PowerSys",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in PowerSys (All versions \u003c V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:H/SI:H/SA:H",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287: Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-11T14:20:59.711Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-024584.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-36266",
        "datePublished": "2024-06-11T11:15:59.201Z",
        "dateReserved": "2024-05-22T15:42:14.849Z",
        "dateUpdated": "2024-08-02T03:37:04.767Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-36266 (GCVE-0-2024-36266)

    Vulnerability from cvelistv5 – Published: 2024-06-11 11:15 – Updated: 2024-08-02 03:37
    VLAI
    Summary
    A vulnerability has been identified in PowerSys (All versions < V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    Impacted products
    Vendor Product Version
    Siemens PowerSys Affected: 0 , < V3.11 (custom)
    Create a notification for this product.
    siemens powersys Affected: 0 , < 3.11 (custom)
        cpe:2.3:a:siemens:powersys:v3.11:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:powersys:v3.11:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "powersys",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "3.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-36266",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-11T13:11:44.819782Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-11T13:14:45.274Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T03:37:04.767Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-024584.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "PowerSys",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in PowerSys (All versions \u003c V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:H/SI:H/SA:H",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287: Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-06-11T14:20:59.711Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-024584.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-36266",
        "datePublished": "2024-06-11T11:15:59.201Z",
        "dateReserved": "2024-05-22T15:42:14.849Z",
        "dateUpdated": "2024-08-02T03:37:04.767Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }