Search criteria
9 vulnerabilities found for PRTG Network Monitor by Paessler
VAR-201807-1874
Vulnerability from variot - Updated: 2025-11-18 13:29An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the PRTG System Administrator web console with administrative privileges can exploit an OS command injection vulnerability (both on the server and on devices) by sending malformed parameters in sensor or notification management scenarios. PRTG Network Monitor Is OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201807-1874",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "prtg network monitor",
"scope": "lt",
"trust": 1.8,
"vendor": "paessler",
"version": "18.2.39"
},
{
"model": "prtg network monitor",
"scope": "gt",
"trust": 1.0,
"vendor": "paessler",
"version": "19.3.52"
},
{
"model": "prtg network monitor",
"scope": "lt",
"trust": 1.0,
"vendor": "paessler",
"version": "21.2.68"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-007924"
},
{
"db": "NVD",
"id": "CVE-2018-9276"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:paessler:prtg_network_monitor",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-007924"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Josh Berry,M4LV0",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201807-062"
}
],
"trust": 0.6
},
"cve": "CVE-2018-9276",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2018-9276",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2018-9276",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.2,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-9276",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-9276",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2018-9276",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2018-9276",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-201807-062",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2018-9276",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2018-9276"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-062"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007924"
},
{
"db": "NVD",
"id": "CVE-2018-9276"
},
{
"db": "NVD",
"id": "CVE-2018-9276"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the PRTG System Administrator web console with administrative privileges can exploit an OS command injection vulnerability (both on the server and on devices) by sending malformed parameters in sensor or notification management scenarios. PRTG Network Monitor Is OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-9276"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007924"
},
{
"db": "VULMON",
"id": "CVE-2018-9276"
}
],
"trust": 1.71
},
"exploit_availability": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"reference": "https://vulmon.com/exploitdetails?qidtp=exploitdb\u0026qid=46527",
"trust": 0.1,
"type": "exploit"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2018-9276"
}
]
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-9276",
"trust": 2.6
},
{
"db": "PACKETSTORM",
"id": "148334",
"trust": 2.5
},
{
"db": "PACKETSTORM",
"id": "161183",
"trust": 1.7
},
{
"db": "EXPLOIT-DB",
"id": "46527",
"trust": 1.7
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007924",
"trust": 0.8
},
{
"db": "PACKETSTORM",
"id": "152030",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201807-062",
"trust": 0.6
},
{
"db": "OTHER",
"id": "NONE",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2018-9276",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULMON",
"id": "CVE-2018-9276"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-062"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007924"
},
{
"db": "NVD",
"id": "CVE-2018-9276"
}
]
},
"id": "VAR-201807-1874",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "OTHER",
"id": null
}
],
"trust": 0.01
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"network device"
],
"sub_category": "network device",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
}
]
},
"last_update_date": "2025-11-18T13:29:14.446000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "April 2018 - Version 18.2.39",
"trust": 0.8,
"url": "https://www.paessler.com/prtg/history/stable#18.2.39"
},
{
"title": "Paessler PRTG Network Monitor Fixes for operating system command injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=81668"
},
{
"title": "CVE-2018-9276",
"trust": 0.1,
"url": "https://github.com/wildkindcc/CVE-2018-9276 "
},
{
"title": "CVE-2018-9276",
"trust": 0.1,
"url": "https://github.com/A1vinSmith/CVE-2018-9276 "
},
{
"title": "7h3rAm-writeups",
"trust": 0.1,
"url": "https://github.com/paramint/7h3rAm-writeups "
},
{
"title": "writeups",
"trust": 0.1,
"url": "https://github.com/7h3rAm/writeups "
},
{
"title": "https-github.com-7h3rAm-writeups",
"trust": 0.1,
"url": "https://github.com/V-R-T/https-github.com-7h3rAm-writeups "
},
{
"title": "",
"trust": 0.1,
"url": "https://github.com/khulnasoft-labs/awesome-security "
},
{
"title": "PoC-in-GitHub",
"trust": 0.1,
"url": "https://github.com/hectorgie/PoC-in-GitHub "
},
{
"title": "CVE-POC",
"trust": 0.1,
"url": "https://github.com/0xT11/CVE-POC "
},
{
"title": "PoC-in-GitHub",
"trust": 0.1,
"url": "https://github.com/nomi-sec/PoC-in-GitHub "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2018-9276"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-062"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007924"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-007924"
},
{
"db": "NVD",
"id": "CVE-2018-9276"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "http://packetstormsecurity.com/files/148334/prtg-command-injection.html"
},
{
"trust": 2.3,
"url": "http://packetstormsecurity.com/files/161183/prtg-network-monitor-remote-code-execution.html"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/archive/1/542103/100/0/threaded"
},
{
"trust": 1.7,
"url": "https://www.exploit-db.com/exploits/46527/"
},
{
"trust": 1.0,
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=cve-2018-9276"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-9276"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-9276"
},
{
"trust": 0.7,
"url": "https://www.exploit-db.com/exploits/46527"
},
{
"trust": 0.6,
"url": "https://packetstormsecurity.com/files/152030/prtg-network-monitor-18.2.38-remote-code-execution.html"
},
{
"trust": 0.1,
"url": "https://ieeexplore.ieee.org/abstract/document/10769424"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"trust": 0.1,
"url": "https://github.com/wildkindcc/cve-2018-9276"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULMON",
"id": "CVE-2018-9276"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-062"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007924"
},
{
"db": "NVD",
"id": "CVE-2018-9276"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULMON",
"id": "CVE-2018-9276"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-062"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007924"
},
{
"db": "NVD",
"id": "CVE-2018-9276"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-07-02T00:00:00",
"db": "VULMON",
"id": "CVE-2018-9276"
},
{
"date": "2018-07-03T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201807-062"
},
{
"date": "2018-10-02T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-007924"
},
{
"date": "2018-07-02T16:29:00.600000",
"db": "NVD",
"id": "CVE-2018-9276"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-25T00:00:00",
"db": "VULMON",
"id": "CVE-2018-9276"
},
{
"date": "2021-01-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201807-062"
},
{
"date": "2018-10-02T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-007924"
},
{
"date": "2025-11-06T16:51:52.337000",
"db": "NVD",
"id": "CVE-2018-9276"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201807-062"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "PRTG Network Monitor In OS Command injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-007924"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201807-062"
}
],
"trust": 0.6
}
}
VAR-201708-1109
Vulnerability from variot - Updated: 2025-04-20 23:42Cross-site scripting (XSS-STORED) vulnerability in the DEVICES OR SENSORS functionality in Paessler PRTG Network Monitor before 17.3.33.2654 allows authenticated remote attackers to inject arbitrary web script or HTML. Paessler PRTG Network Monitor Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. PaesslerPRTGNetworkMonitor is a full-featured network monitoring management software from Paessler AG, Germany. A cross-site scripting vulnerability exists in the DEVICESORSENSORS feature in versions prior to PaesslerPRTGNetworkMonitor 17.3.33.2654
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201708-1109",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "prtg network monitor",
"scope": "lte",
"trust": 1.0,
"vendor": "paessler",
"version": "17.3.33"
},
{
"model": "prtg network monitor",
"scope": "lt",
"trust": 0.8,
"vendor": "paessler",
"version": "17.3.33.2654"
},
{
"model": "ag paessler prtg network monitor",
"scope": "lt",
"trust": 0.6,
"vendor": "paessler",
"version": "17.3.33.2654"
},
{
"model": "prtg network monitor",
"scope": "eq",
"trust": 0.6,
"vendor": "paessler",
"version": "17.3.33"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-30563"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-007639"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-707"
},
{
"db": "NVD",
"id": "CVE-2017-12879"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:paessler:prtg_network_monitor",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-007639"
}
]
},
"cve": "CVE-2017-12879",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CVE-2017-12879",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CNVD-2017-30563",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.3,
"id": "CVE-2017-12879",
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 1.8,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-12879",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2017-12879",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2017-30563",
"trust": 0.6,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-201708-707",
"trust": 0.6,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-30563"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-007639"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-707"
},
{
"db": "NVD",
"id": "CVE-2017-12879"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cross-site scripting (XSS-STORED) vulnerability in the DEVICES OR SENSORS functionality in Paessler PRTG Network Monitor before 17.3.33.2654 allows authenticated remote attackers to inject arbitrary web script or HTML. Paessler PRTG Network Monitor Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. PaesslerPRTGNetworkMonitor is a full-featured network monitoring management software from Paessler AG, Germany. A cross-site scripting vulnerability exists in the DEVICESORSENSORS feature in versions prior to PaesslerPRTGNetworkMonitor 17.3.33.2654",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-12879"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-007639"
},
{
"db": "CNVD",
"id": "CNVD-2017-30563"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-12879",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2017-007639",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2017-30563",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201708-707",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-30563"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-007639"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-707"
},
{
"db": "NVD",
"id": "CVE-2017-12879"
}
]
},
"id": "VAR-201708-1109",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-30563"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-30563"
}
]
},
"last_update_date": "2025-04-20T23:42:57.907000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Release Notes for the \"Preview\" Release Channel",
"trust": 0.8,
"url": "https://www.paessler.com/prtg/history/preview"
},
{
"title": "Release Notes for the \"Stable\" Release Channel",
"trust": 0.8,
"url": "https://www.paessler.com/prtg/history/stable"
},
{
"title": "Patch for PaesslerPRTGNetworkMonitor Cross-Site Scripting Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/103997"
},
{
"title": "Paessler PRTG Network Monitor Fixes for cross-site scripting vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=74065"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-30563"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-007639"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-707"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-007639"
},
{
"db": "NVD",
"id": "CVE-2017-12879"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "https://drive.google.com/open?id=0b6wbmqxsfqqfodzhugtldzu3eda"
},
{
"trust": 1.6,
"url": "https://www.paessler.com/prtg/history/preview"
},
{
"trust": 1.0,
"url": "https://youtu.be/qoldh2oey8q"
},
{
"trust": 1.0,
"url": "https://www.paessler.com/prtg/history/stable"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-12879"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-12879"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-30563"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-007639"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-707"
},
{
"db": "NVD",
"id": "CVE-2017-12879"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2017-30563"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-007639"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-707"
},
{
"db": "NVD",
"id": "CVE-2017-12879"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-10-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-30563"
},
{
"date": "2017-09-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-007639"
},
{
"date": "2017-08-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201708-707"
},
{
"date": "2017-08-24T19:29:00.203000",
"db": "NVD",
"id": "CVE-2017-12879"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-10-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-30563"
},
{
"date": "2017-09-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-007639"
},
{
"date": "2017-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201708-707"
},
{
"date": "2025-04-20T01:37:25.860000",
"db": "NVD",
"id": "CVE-2017-12879"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201708-707"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Paessler PRTG Network Monitor Cross-Site Scripting Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-30563"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-707"
}
],
"trust": 1.2
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201708-707"
}
],
"trust": 0.6
}
}
VAR-201710-0667
Vulnerability from variot - Updated: 2025-04-20 23:30PRTG Network Monitor version 17.3.33.2830 is vulnerable to stored Cross-Site Scripting on all group names created, related to incorrect error handling for an HTML encoded script. PRTG Network Monitor Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. PaesslerPRTGNetworkMonitor is a network monitoring software from Paessler, Germany. The software provides usage monitoring, packet sniffing, in-depth analysis, and concise reporting. A remote attacker can exploit this vulnerability to inject arbitrary web scripts or HTML
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201710-0667",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "prtg network monitor",
"scope": "eq",
"trust": 3.0,
"vendor": "paessler",
"version": "17.3.33.2830"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-32222"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009276"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-496"
},
{
"db": "NVD",
"id": "CVE-2017-15360"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:paessler:prtg_network_monitor",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-009276"
}
]
},
"cve": "CVE-2017-15360",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CVE-2017-15360",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2017-32222",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.3,
"id": "CVE-2017-15360",
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 1.8,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-15360",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2017-15360",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2017-32222",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201710-496",
"trust": 0.6,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-32222"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009276"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-496"
},
{
"db": "NVD",
"id": "CVE-2017-15360"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "PRTG Network Monitor version 17.3.33.2830 is vulnerable to stored Cross-Site Scripting on all group names created, related to incorrect error handling for an HTML encoded script. PRTG Network Monitor Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. PaesslerPRTGNetworkMonitor is a network monitoring software from Paessler, Germany. The software provides usage monitoring, packet sniffing, in-depth analysis, and concise reporting. A remote attacker can exploit this vulnerability to inject arbitrary web scripts or HTML",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-15360"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009276"
},
{
"db": "CNVD",
"id": "CNVD-2017-32222"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-15360",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009276",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2017-32222",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201710-496",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-32222"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009276"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-496"
},
{
"db": "NVD",
"id": "CVE-2017-15360"
}
]
},
"id": "VAR-201710-0667",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-32222"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-32222"
}
]
},
"last_update_date": "2025-04-20T23:30:51.873000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.paessler.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-009276"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-009276"
},
{
"db": "NVD",
"id": "CVE-2017-15360"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://medium.com/stolabs/security-issue-on-prtg-network-manager-ada65b45d37b"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-15360"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-15360"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-32222"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009276"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-496"
},
{
"db": "NVD",
"id": "CVE-2017-15360"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2017-32222"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009276"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-496"
},
{
"db": "NVD",
"id": "CVE-2017-15360"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-11-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-32222"
},
{
"date": "2017-11-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-009276"
},
{
"date": "2017-10-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201710-496"
},
{
"date": "2017-10-15T17:29:00.213000",
"db": "NVD",
"id": "CVE-2017-15360"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-11-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-32222"
},
{
"date": "2017-11-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-009276"
},
{
"date": "2017-10-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201710-496"
},
{
"date": "2025-04-20T01:37:25.860000",
"db": "NVD",
"id": "CVE-2017-15360"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201710-496"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "PRTG Network Monitor Vulnerable to cross-site scripting",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-009276"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201710-496"
}
],
"trust": 0.6
}
}
VAR-201710-1028
Vulnerability from variot - Updated: 2025-04-20 22:49PRTG Network Monitor version 17.3.33.2830 is vulnerable to stored Cross-Site Scripting on all sensor titles, related to incorrect error handling for a %00 in the SRC attribute of an IMG element. PRTG Network Monitor Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201710-1028",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "prtg network monitor",
"scope": "eq",
"trust": 2.4,
"vendor": "paessler",
"version": "17.3.33.2830"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-008633"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-417"
},
{
"db": "NVD",
"id": "CVE-2017-15008"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:paessler:prtg_network_monitor",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-008633"
}
]
},
"cve": "CVE-2017-15008",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CVE-2017-15008",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.7,
"id": "CVE-2017-15008",
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"trust": 1.8,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-15008",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2017-15008",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-201710-417",
"trust": 0.6,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-008633"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-417"
},
{
"db": "NVD",
"id": "CVE-2017-15008"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "PRTG Network Monitor version 17.3.33.2830 is vulnerable to stored Cross-Site Scripting on all sensor titles, related to incorrect error handling for a %00 in the SRC attribute of an IMG element. PRTG Network Monitor Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-15008"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008633"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-15008",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008633",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201710-417",
"trust": 0.6
},
{
"db": "OTHER",
"id": "NONE",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008633"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-417"
},
{
"db": "NVD",
"id": "CVE-2017-15008"
}
]
},
"id": "VAR-201710-1028",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "OTHER",
"id": null
}
],
"trust": 0.01
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"network device"
],
"sub_category": "network device",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
}
]
},
"last_update_date": "2025-04-20T22:49:30.841000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Release Notes for the \"Stable\" Release Channel",
"trust": 0.8,
"url": "https://www.paessler.com/prtg/history/stable"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-008633"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-008633"
},
{
"db": "NVD",
"id": "CVE-2017-15008"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://medium.com/stolabs/security-issue-on-prtg-network-manager-ada65b45d37b"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-15008"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-15008"
},
{
"trust": 0.1,
"url": "https://ieeexplore.ieee.org/abstract/document/10769424"
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008633"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-417"
},
{
"db": "NVD",
"id": "CVE-2017-15008"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "OTHER",
"id": null
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008633"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-417"
},
{
"db": "NVD",
"id": "CVE-2017-15008"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-10-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-008633"
},
{
"date": "2017-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201710-417"
},
{
"date": "2017-10-04T01:29:03.340000",
"db": "NVD",
"id": "CVE-2017-15008"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-10-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-008633"
},
{
"date": "2017-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201710-417"
},
{
"date": "2025-04-20T01:37:25.860000",
"db": "NVD",
"id": "CVE-2017-15008"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201710-417"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "PRTG Network Monitor Vulnerable to cross-site scripting",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-008633"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201710-417"
}
],
"trust": 0.6
}
}
VAR-201811-0885
Vulnerability from variot - Updated: 2025-01-30 21:06PRTG Network Monitor before 18.3.44.2054 allows a remote authenticated attacker (with read-write privileges) to execute arbitrary code and OS commands with system privileges. When creating an HTTP Advanced Sensor, the user's input in the POST parameter 'proxyport_' is mishandled. The attacker can craft an HTTP request and override the 'writeresult' command-line parameter for HttpAdvancedSensor.exe to store arbitrary data in an arbitrary place on the file system. For example, the attacker can create an executable file in the \Custom Sensors\EXE directory and execute it by creating EXE/Script Sensor. PRTG Network Monitor Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201811-0885",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "prtg network monitor",
"scope": "lt",
"trust": 1.8,
"vendor": "paessler",
"version": "18.3.44.2054"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014183"
},
{
"db": "NVD",
"id": "CVE-2018-19204"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:paessler:prtg_network_monitor",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014183"
}
]
},
"cve": "CVE-2018-19204",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2018-19204",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2018-19204",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-19204",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2018-19204",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-201811-305",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2018-19204",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2018-19204"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014183"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-305"
},
{
"db": "NVD",
"id": "CVE-2018-19204"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "PRTG Network Monitor before 18.3.44.2054 allows a remote authenticated attacker (with read-write privileges) to execute arbitrary code and OS commands with system privileges. When creating an HTTP Advanced Sensor, the user\u0027s input in the POST parameter \u0027proxyport_\u0027 is mishandled. The attacker can craft an HTTP request and override the \u0027writeresult\u0027 command-line parameter for HttpAdvancedSensor.exe to store arbitrary data in an arbitrary place on the file system. For example, the attacker can create an executable file in the \\Custom Sensors\\EXE directory and execute it by creating EXE/Script Sensor. PRTG Network Monitor Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-19204"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014183"
},
{
"db": "VULMON",
"id": "CVE-2018-19204"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-19204",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014183",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201811-305",
"trust": 0.6
},
{
"db": "OTHER",
"id": "NONE",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2018-19204",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULMON",
"id": "CVE-2018-19204"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014183"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-305"
},
{
"db": "NVD",
"id": "CVE-2018-19204"
}
]
},
"id": "VAR-201811-0885",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "OTHER",
"id": null
}
],
"trust": 0.01
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"network device"
],
"sub_category": "network device",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
}
]
},
"last_update_date": "2025-01-30T21:06:39.147000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "September 24th 2018 - Version 18.3.44.2054",
"trust": 0.8,
"url": "https://www.paessler.com/prtg/history/prtg-18#18.3.44.2054"
},
{
"title": "Paessler PRTG Network Monitor Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=86730"
},
{
"title": "sec-daily-2019",
"trust": 0.1,
"url": "https://github.com/alphaSeclab/sec-daily-2019 "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2018-19204"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014183"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-305"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.0
},
{
"problemtype": "CWE-264",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014183"
},
{
"db": "NVD",
"id": "CVE-2018-19204"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://www.ptsecurity.com/ww-en/analytics/threatscape/pt-2018-23/"
},
{
"trust": 1.7,
"url": "https://www.paessler.com/prtg/history/stable#18.3.44.2054"
},
{
"trust": 1.7,
"url": "http://en.securitylab.ru/lab/pt-2018-23"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-19204"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-19204"
},
{
"trust": 0.1,
"url": "https://ieeexplore.ieee.org/abstract/document/10769424"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://github.com/alphaseclab/sec-daily-2019"
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULMON",
"id": "CVE-2018-19204"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014183"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-305"
},
{
"db": "NVD",
"id": "CVE-2018-19204"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULMON",
"id": "CVE-2018-19204"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014183"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-305"
},
{
"db": "NVD",
"id": "CVE-2018-19204"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-11-12T00:00:00",
"db": "VULMON",
"id": "CVE-2018-19204"
},
{
"date": "2019-03-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014183"
},
{
"date": "2018-11-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201811-305"
},
{
"date": "2018-11-12T16:29:00.497000",
"db": "NVD",
"id": "CVE-2018-19204"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-06-29T00:00:00",
"db": "VULMON",
"id": "CVE-2018-19204"
},
{
"date": "2019-03-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014183"
},
{
"date": "2019-10-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201811-305"
},
{
"date": "2024-11-21T03:57:32.990000",
"db": "NVD",
"id": "CVE-2018-19204"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201811-305"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "PRTG Network Monitor Vulnerabilities related to authorization, permissions, and access control",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014183"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "input validation error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201811-305"
}
],
"trust": 0.6
}
}
CVE-2024-12833 (GCVE-0-2024-12833)
Vulnerability from nvd – Published: 2025-02-11 19:23 – Updated: 2025-02-12 19:11- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Paessler | PRTG Network Monitor |
Affected:
24.1.92.1554 x64
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-12833",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-11T19:54:24.218569Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T19:11:13.548Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "PRTG Network Monitor",
"vendor": "Paessler",
"versions": [
{
"status": "affected",
"version": "24.1.92.1554 x64"
}
]
}
],
"dateAssigned": "2024-12-19T22:20:57.954Z",
"datePublic": "2025-01-20T02:52:23.415Z",
"descriptions": [
{
"lang": "en",
"value": "Paessler PRTG Network Monitor SNMP Cross-Site Scripting Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Paessler PRTG Network Monitor. Some user interaction on the part of an administrator is required to exploit this vulnerability.\n\nThe specific flaw exists within the PRTG Network Monitor web interface. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-23371."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T19:23:53.715Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-1736",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1736/"
}
],
"source": {
"lang": "en",
"value": "Andreas Finstad"
},
"title": "Paessler PRTG Network Monitor SNMP Cross-Site Scripting Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2024-12833",
"datePublished": "2025-02-11T19:23:53.715Z",
"dateReserved": "2024-12-19T22:20:57.912Z",
"dateUpdated": "2025-02-12T19:11:13.548Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-51630 (GCVE-0-2023-51630)
Vulnerability from nvd – Published: 2024-02-08 22:13 – Updated: 2024-08-02 22:40- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Paessler | PRTG Network Monitor |
Affected:
23.2.84.1566
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-51630",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-09T19:22:15.878574Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T17:20:49.020Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:40:33.954Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-24-073",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-073/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "PRTG Network Monitor",
"vendor": "Paessler",
"versions": [
{
"status": "affected",
"version": "23.2.84.1566"
}
]
}
],
"dateAssigned": "2023-12-20T16:02:27.445-06:00",
"datePublic": "2024-01-15T00:44:18.756-06:00",
"descriptions": [
{
"lang": "en",
"value": "Paessler PRTG Network Monitor Cross-Site Scripting Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Paessler PRTG Network Monitor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the web console. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to bypass authentication on the system.\n. Was ZDI-CAN-21182."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-08T22:13:34.474Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-073",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-073/"
}
],
"source": {
"lang": "en",
"value": "n1nj4sec"
},
"title": "Paessler PRTG Network Monitor Cross-Site Scripting Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-51630",
"datePublished": "2024-02-08T22:13:34.474Z",
"dateReserved": "2023-12-20T21:52:34.962Z",
"dateUpdated": "2024-08-02T22:40:33.954Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-12833 (GCVE-0-2024-12833)
Vulnerability from cvelistv5 – Published: 2025-02-11 19:23 – Updated: 2025-02-12 19:11- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Paessler | PRTG Network Monitor |
Affected:
24.1.92.1554 x64
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-12833",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-11T19:54:24.218569Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T19:11:13.548Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "PRTG Network Monitor",
"vendor": "Paessler",
"versions": [
{
"status": "affected",
"version": "24.1.92.1554 x64"
}
]
}
],
"dateAssigned": "2024-12-19T22:20:57.954Z",
"datePublic": "2025-01-20T02:52:23.415Z",
"descriptions": [
{
"lang": "en",
"value": "Paessler PRTG Network Monitor SNMP Cross-Site Scripting Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Paessler PRTG Network Monitor. Some user interaction on the part of an administrator is required to exploit this vulnerability.\n\nThe specific flaw exists within the PRTG Network Monitor web interface. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-23371."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T19:23:53.715Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-1736",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1736/"
}
],
"source": {
"lang": "en",
"value": "Andreas Finstad"
},
"title": "Paessler PRTG Network Monitor SNMP Cross-Site Scripting Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2024-12833",
"datePublished": "2025-02-11T19:23:53.715Z",
"dateReserved": "2024-12-19T22:20:57.912Z",
"dateUpdated": "2025-02-12T19:11:13.548Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-51630 (GCVE-0-2023-51630)
Vulnerability from cvelistv5 – Published: 2024-02-08 22:13 – Updated: 2024-08-02 22:40- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Paessler | PRTG Network Monitor |
Affected:
23.2.84.1566
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-51630",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-09T19:22:15.878574Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T17:20:49.020Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:40:33.954Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-24-073",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-073/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "PRTG Network Monitor",
"vendor": "Paessler",
"versions": [
{
"status": "affected",
"version": "23.2.84.1566"
}
]
}
],
"dateAssigned": "2023-12-20T16:02:27.445-06:00",
"datePublic": "2024-01-15T00:44:18.756-06:00",
"descriptions": [
{
"lang": "en",
"value": "Paessler PRTG Network Monitor Cross-Site Scripting Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Paessler PRTG Network Monitor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the web console. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to bypass authentication on the system.\n. Was ZDI-CAN-21182."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-08T22:13:34.474Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-073",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-073/"
}
],
"source": {
"lang": "en",
"value": "n1nj4sec"
},
"title": "Paessler PRTG Network Monitor Cross-Site Scripting Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-51630",
"datePublished": "2024-02-08T22:13:34.474Z",
"dateReserved": "2023-12-20T21:52:34.962Z",
"dateUpdated": "2024-08-02T22:40:33.954Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",