Search criteria

3 vulnerabilities found for Orbi Satellite RBS750 by Netgear

VAR-202303-1641

Vulnerability from variot - Updated: 2025-06-25 23:17

A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability. of netgear RBS750 The firmware contains a vulnerability related to an undisclosed function.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. NETGEAR Orbi Satellite RBS750 is a professional-grade tri-band satellite router from NETGEAR

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202303-1641",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "rbs750",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "4.6.8.5"
      },
      {
        "model": "rbs750",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "rbs750",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": "rbs750  firmware  4.6.8.5"
      },
      {
        "model": "rbs750",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "orbi satellite rbs750",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "netgear",
        "version": "4.6.8.5"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13350"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-021248"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36429"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Discovered by Dave McDaniel of Cisco Talos.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1597"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-36429",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.4,
            "id": "CNVD-2025-13350",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "id": "CVE-2022-36429",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.2,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-36429",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-36429",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "talos-cna@cisco.com",
            "id": "CVE-2022-36429",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-36429",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-13350",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202303-1597",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13350"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-021248"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1597"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36429"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36429"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability. of netgear RBS750 The firmware contains a vulnerability related to an undisclosed function.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. NETGEAR Orbi Satellite RBS750 is a professional-grade tri-band satellite router from NETGEAR",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36429"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-021248"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-13350"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-36429",
        "trust": 3.8
      },
      {
        "db": "TALOS",
        "id": "TALOS-2022-1597",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-021248",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-13350",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1597",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13350"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-021248"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1597"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36429"
      }
    ]
  },
  "id": "VAR-202303-1641",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13350"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13350"
      }
    ]
  },
  "last_update_date": "2025-06-25T23:17:09.466000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for NETGEAR Orbi Satellite RBS750 ubus backend communication function command execution vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/700446"
      },
      {
        "title": "NETGEAR Orbi Satellite RBS750 Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=229674"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13350"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1597"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-912",
        "trust": 1.0
      },
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      },
      {
        "problemtype": "Unpublished features (CWE-912) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-021248"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36429"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.6,
        "url": "https://talosintelligence.com/vulnerability_reports/talos-2022-1597"
      },
      {
        "trust": 2.4,
        "url": "https://kb.netgear.com/000065424/security-advisory-for-command-injection-on-some-orbi-wifi-systems-psv-2022-0188"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36429"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-36429/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13350"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-021248"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1597"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36429"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13350"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-021248"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1597"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36429"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-06-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-13350"
      },
      {
        "date": "2023-11-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-021248"
      },
      {
        "date": "2023-03-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202303-1597"
      },
      {
        "date": "2023-03-21T18:15:11.970000",
        "db": "NVD",
        "id": "CVE-2022-36429"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-06-24T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-13350"
      },
      {
        "date": "2023-11-09T07:15:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-021248"
      },
      {
        "date": "2023-03-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202303-1597"
      },
      {
        "date": "2023-03-29T11:15:06.750000",
        "db": "NVD",
        "id": "CVE-2022-36429"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1597"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "of netgear \u00a0RBS750\u00a0 Vulnerabilities related to private functions in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-021248"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202303-1597"
      }
    ],
    "trust": 0.6
  }
}

CVE-2022-36429 (GCVE-0-2022-36429)

Vulnerability from nvd – Published: 2023-03-21 17:41 – Updated: 2024-08-03 10:07
VLAI?
Summary
A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
CWE
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:07:33.896Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
          },
          {
            "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597",
            "tags": [
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
          },
          {
            "name": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188",
            "tags": [
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:netgear:rbs750_firmware:4.6.8.5:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rbs750_firmware",
            "vendor": "netgear",
            "versions": [
              {
                "status": "affected",
                "version": "4.6.8.5"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-36429",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-01T15:42:46.126213Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-01T15:52:41.065Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Orbi Satellite RBS750",
          "vendor": "Netgear",
          "versions": [
            {
              "status": "affected",
              "version": "4.6.8.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-912",
              "description": "CWE-912: Hidden Functionality",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-29T10:14:37.184Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597",
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
        },
        {
          "name": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188",
          "url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-36429",
    "datePublished": "2023-03-21T17:41:25.748Z",
    "dateReserved": "2022-08-23T17:55:12.245Z",
    "dateUpdated": "2024-08-03T10:07:33.896Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-36429 (GCVE-0-2022-36429)

Vulnerability from cvelistv5 – Published: 2023-03-21 17:41 – Updated: 2024-08-03 10:07
VLAI?
Summary
A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
CWE
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:07:33.896Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
          },
          {
            "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597",
            "tags": [
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
          },
          {
            "name": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188",
            "tags": [
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:netgear:rbs750_firmware:4.6.8.5:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rbs750_firmware",
            "vendor": "netgear",
            "versions": [
              {
                "status": "affected",
                "version": "4.6.8.5"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-36429",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-01T15:42:46.126213Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-01T15:52:41.065Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Orbi Satellite RBS750",
          "vendor": "Netgear",
          "versions": [
            {
              "status": "affected",
              "version": "4.6.8.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-912",
              "description": "CWE-912: Hidden Functionality",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-29T10:14:37.184Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597",
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
        },
        {
          "name": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188",
          "url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-36429",
    "datePublished": "2023-03-21T17:41:25.748Z",
    "dateReserved": "2022-08-23T17:55:12.245Z",
    "dateUpdated": "2024-08-03T10:07:33.896Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}