Search criteria
3 vulnerabilities found for Orbi Satellite RBS750 by Netgear
VAR-202303-1641
Vulnerability from variot - Updated: 2025-06-25 23:17A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability. of netgear RBS750 The firmware contains a vulnerability related to an undisclosed function.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. NETGEAR Orbi Satellite RBS750 is a professional-grade tri-band satellite router from NETGEAR
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202303-1641",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "rbs750",
"scope": "eq",
"trust": 1.0,
"vendor": "netgear",
"version": "4.6.8.5"
},
{
"model": "rbs750",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "rbs750",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": "rbs750 firmware 4.6.8.5"
},
{
"model": "rbs750",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "orbi satellite rbs750",
"scope": "eq",
"trust": 0.6,
"vendor": "netgear",
"version": "4.6.8.5"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13350"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-021248"
},
{
"db": "NVD",
"id": "CVE-2022-36429"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Discovered by Dave McDaniel of Cisco Talos.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202303-1597"
}
],
"trust": 0.6
},
"cve": "CVE-2022-36429",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "MULTIPLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.4,
"id": "CNVD-2025-13350",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2022-36429",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.2,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-36429",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-36429",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "talos-cna@cisco.com",
"id": "CVE-2022-36429",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-36429",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-13350",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202303-1597",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13350"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-021248"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1597"
},
{
"db": "NVD",
"id": "CVE-2022-36429"
},
{
"db": "NVD",
"id": "CVE-2022-36429"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability. of netgear RBS750 The firmware contains a vulnerability related to an undisclosed function.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. NETGEAR Orbi Satellite RBS750 is a professional-grade tri-band satellite router from NETGEAR",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-36429"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-021248"
},
{
"db": "CNVD",
"id": "CNVD-2025-13350"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-36429",
"trust": 3.8
},
{
"db": "TALOS",
"id": "TALOS-2022-1597",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2022-021248",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-13350",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1597",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13350"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-021248"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1597"
},
{
"db": "NVD",
"id": "CVE-2022-36429"
}
]
},
"id": "VAR-202303-1641",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13350"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13350"
}
]
},
"last_update_date": "2025-06-25T23:17:09.466000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for NETGEAR Orbi Satellite RBS750 ubus backend communication function command execution vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/700446"
},
{
"title": "NETGEAR Orbi Satellite RBS750 Security vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=229674"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13350"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1597"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-912",
"trust": 1.0
},
{
"problemtype": "NVD-CWE-Other",
"trust": 1.0
},
{
"problemtype": "Unpublished features (CWE-912) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-021248"
},
{
"db": "NVD",
"id": "CVE-2022-36429"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.6,
"url": "https://talosintelligence.com/vulnerability_reports/talos-2022-1597"
},
{
"trust": 2.4,
"url": "https://kb.netgear.com/000065424/security-advisory-for-command-injection-on-some-orbi-wifi-systems-psv-2022-0188"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-36429"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-36429/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13350"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-021248"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1597"
},
{
"db": "NVD",
"id": "CVE-2022-36429"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-13350"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-021248"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1597"
},
{
"db": "NVD",
"id": "CVE-2022-36429"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-13350"
},
{
"date": "2023-11-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-021248"
},
{
"date": "2023-03-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202303-1597"
},
{
"date": "2023-03-21T18:15:11.970000",
"db": "NVD",
"id": "CVE-2022-36429"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-13350"
},
{
"date": "2023-11-09T07:15:00",
"db": "JVNDB",
"id": "JVNDB-2022-021248"
},
{
"date": "2023-03-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202303-1597"
},
{
"date": "2023-03-29T11:15:06.750000",
"db": "NVD",
"id": "CVE-2022-36429"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202303-1597"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "of netgear \u00a0RBS750\u00a0 Vulnerabilities related to private functions in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-021248"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202303-1597"
}
],
"trust": 0.6
}
}
CVE-2022-36429 (GCVE-0-2022-36429)
Vulnerability from nvd – Published: 2023-03-21 17:41 – Updated: 2024-08-03 10:07
VLAI?
Summary
A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
Severity ?
7.2 (High)
CWE
- CWE-912 - Hidden Functionality
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | Orbi Satellite RBS750 |
Affected:
4.6.8.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:07:33.896Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"name": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188",
"tags": [
"x_transferred"
],
"url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:netgear:rbs750_firmware:4.6.8.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rbs750_firmware",
"vendor": "netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36429",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T15:42:46.126213Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T15:52:41.065Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Orbi Satellite RBS750",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-912",
"description": "CWE-912: Hidden Functionality",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-29T10:14:37.184Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"name": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188",
"url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-36429",
"datePublished": "2023-03-21T17:41:25.748Z",
"dateReserved": "2022-08-23T17:55:12.245Z",
"dateUpdated": "2024-08-03T10:07:33.896Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36429 (GCVE-0-2022-36429)
Vulnerability from cvelistv5 – Published: 2023-03-21 17:41 – Updated: 2024-08-03 10:07
VLAI?
Summary
A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
Severity ?
7.2 (High)
CWE
- CWE-912 - Hidden Functionality
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | Orbi Satellite RBS750 |
Affected:
4.6.8.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:07:33.896Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"name": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188",
"tags": [
"x_transferred"
],
"url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:netgear:rbs750_firmware:4.6.8.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rbs750_firmware",
"vendor": "netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36429",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T15:42:46.126213Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T15:52:41.065Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Orbi Satellite RBS750",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-912",
"description": "CWE-912: Hidden Functionality",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-29T10:14:37.184Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"name": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188",
"url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-36429",
"datePublished": "2023-03-21T17:41:25.748Z",
"dateReserved": "2022-08-23T17:55:12.245Z",
"dateUpdated": "2024-08-03T10:07:33.896Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}