Search criteria
3 vulnerabilities found for Opcenter RDL by Siemens
VAR-202412-3346
Vulnerability from variot - Updated: 2025-01-11 23:23The Opcenter Research Development & Laboratory (RD&L) series of software products can simplify, optimize and adjust the formulation product development, improve the innovation efficiency of fast-moving consumer goods, and optimize the data management of fast-moving consumer goods.
Siemens Opcenter RDL has a buffer overflow vulnerability, which can be exploited by unauthenticated remote attackers to execute arbitrary code.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202412-3346",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "opcenter rdl",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48433"
}
]
},
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "CNVD-2024-48433",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "CNVD",
"id": "CNVD-2024-48433",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48433"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Opcenter Research Development \u0026 Laboratory (RD\u0026L) series of software products can simplify, optimize and adjust the formulation product development, improve the innovation efficiency of fast-moving consumer goods, and optimize the data management of fast-moving consumer goods.\n\nSiemens Opcenter RDL has a buffer overflow vulnerability, which can be exploited by unauthenticated remote attackers to execute arbitrary code.",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48433"
}
],
"trust": 0.6
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-48433",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48433"
}
]
},
"id": "VAR-202412-3346",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48433"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48433"
}
]
},
"last_update_date": "2025-01-11T23:23:02.257000Z",
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-48433"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-12-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-48433"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-12-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-48433"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens Opcenter RDL Buffer Overflow Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-48433"
}
],
"trust": 0.6
}
}
CVE-2024-49775 (GCVE-0-2024-49775)
Vulnerability from nvd – Published: 2024-12-16 15:06 – Updated: 2026-01-13 09:43
VLAI?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component.
This could allow an unauthenticated remote attacker to execute arbitrary code.
Severity ?
9.8 (Critical)
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Opcenter Execution Foundation |
Affected:
0 , < V2501.0001
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-49775",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-16T16:33:33.058713Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-12T16:34:51.664Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2501.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2501.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter RDnL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2410",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS neo V4.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS neo V4.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1 Update 3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS neo V5.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.0 Update 1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINEC NMS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Totally Integrated Automation Portal (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Totally Integrated Automation Portal (TIA Portal) V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Totally Integrated Automation Portal (TIA Portal) V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Totally Integrated Automation Portal (TIA Portal) V19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2501.0001), Opcenter Intelligence (All versions \u003c V2501.0001), Opcenter Quality (All versions \u003c V2512), Opcenter RDnL (All versions \u003c V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions \u003c V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions \u003c V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC \u003c V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component.\r\nThis could allow an unauthenticated remote attacker to execute arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-13T09:43:48.714Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-928984.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-49775",
"datePublished": "2024-12-16T15:06:04.714Z",
"dateReserved": "2024-10-18T14:25:05.725Z",
"dateUpdated": "2026-01-13T09:43:48.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-49775 (GCVE-0-2024-49775)
Vulnerability from cvelistv5 – Published: 2024-12-16 15:06 – Updated: 2026-01-13 09:43
VLAI?
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component.
This could allow an unauthenticated remote attacker to execute arbitrary code.
Severity ?
9.8 (Critical)
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Opcenter Execution Foundation |
Affected:
0 , < V2501.0001
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-49775",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-16T16:33:33.058713Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-12T16:34:51.664Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2501.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2501.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter RDnL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2410",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS neo V4.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS neo V4.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1 Update 3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS neo V5.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.0 Update 1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINEC NMS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Totally Integrated Automation Portal (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Totally Integrated Automation Portal (TIA Portal) V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Totally Integrated Automation Portal (TIA Portal) V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Totally Integrated Automation Portal (TIA Portal) V19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Opcenter Execution Foundation (All versions \u003c V2501.0001), Opcenter Intelligence (All versions \u003c V2501.0001), Opcenter Quality (All versions \u003c V2512), Opcenter RDnL (All versions \u003c V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions \u003c V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions \u003c V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC \u003c V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component.\r\nThis could allow an unauthenticated remote attacker to execute arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-13T09:43:48.714Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-928984.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-49775",
"datePublished": "2024-12-16T15:06:04.714Z",
"dateReserved": "2024-10-18T14:25:05.725Z",
"dateUpdated": "2026-01-13T09:43:48.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}