Search criteria

43 vulnerabilities found for Nexpose by Rapid7

VAR-201706-0311

Vulnerability from variot - Updated: 2025-04-20 23:04

The default SSH configuration in Rapid7 Nexpose hardware appliances shipped before June 2017 does not specify desired algorithms for key exchange and other important functions. As a result, it falls back to allowing ALL algorithms supported by the relevant version of OpenSSH and makes the installations vulnerable to a range of MITM, downgrade, and decryption attacks. Rapid7 Nexpose Contains a vulnerability in the use of cryptographic algorithms.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Rapid7Nexposehardwareappliances is a hardware device with Nexpose from Rapid7 in the United States. Nexpose is a vulnerability management software that can comprehensively utilize different scan results for deep probing networks. A man-in-the-middle attack vulnerability exists in the default SSH configuration in the Rapid7Nexpose hardware device. An attacker can exploit this vulnerability to perform man-in-the-middle attacks, downgrade attacks, and decryption attacks

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201706-0311",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "nexpose",
        "scope": null,
        "trust": 1.4,
        "vendor": "rapid7",
        "version": null
      },
      {
        "model": "nexpose",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rapid7",
        "version": "6.4.40"
      },
      {
        "model": "nexpose",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rapid7",
        "version": "6.4.40"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-11069"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201701-424"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5243"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:rapid7:nexpose",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004681"
      }
    ]
  },
  "cve": "CVE-2017-5243",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2017-5243",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2017-11069",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2017-5243",
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-5243",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-5243",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-11069",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201701-424",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-11069"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201701-424"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5243"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The default SSH configuration in Rapid7 Nexpose hardware appliances shipped before June 2017 does not specify desired algorithms for key exchange and other important functions. As a result, it falls back to allowing ALL algorithms supported by the relevant version of OpenSSH and makes the installations vulnerable to a range of MITM, downgrade, and decryption attacks. Rapid7 Nexpose Contains a vulnerability in the use of cryptographic algorithms.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Rapid7Nexposehardwareappliances is a hardware device with Nexpose from Rapid7 in the United States. Nexpose is a vulnerability management software that can comprehensively utilize different scan results for deep probing networks. A man-in-the-middle attack vulnerability exists in the default SSH configuration in the Rapid7Nexpose hardware device. An attacker can exploit this vulnerability to perform man-in-the-middle attacks, downgrade attacks, and decryption attacks",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-5243"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004681"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-11069"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-5243",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004681",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-11069",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201701-424",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-11069"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201701-424"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5243"
      }
    ]
  },
  "id": "VAR-201706-0311",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-11069"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-11069"
      }
    ]
  },
  "last_update_date": "2025-04-20T23:04:56.517000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "R7-2017-13 |  CVE-2017-5243: Nexpose Hardware Appliance SSH Enabled Obsolete Algorithms",
        "trust": 0.8,
        "url": "https://community.rapid7.com/community/nexpose/blog/2017/05/31/r7-2017-13-nexpose-hardware-appliance-ssh-enabled-obsolete-algorithms-cve-2017-5243"
      },
      {
        "title": "Rapid7Nexpose hardware device man-in-the-middle attack vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/96360"
      },
      {
        "title": "Rapid7 Nexpose Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=99621"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-11069"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201701-424"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-327",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004681"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5243"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://community.rapid7.com/community/nexpose/blog/2017/05/31/r7-2017-13-nexpose-hardware-appliance-ssh-enabled-obsolete-algorithms-cve-2017-5243"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-5243"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-5243"
      },
      {
        "trust": 0.6,
        "url": "https://darkwebcthnhejsb.onion.link/nexpose-appliances-ssh-flaw.html"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-11069"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201701-424"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5243"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-11069"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201701-424"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-5243"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-06-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-11069"
      },
      {
        "date": "2017-07-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-004681"
      },
      {
        "date": "2017-01-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201701-424"
      },
      {
        "date": "2017-06-06T16:29:00.173000",
        "db": "NVD",
        "id": "CVE-2017-5243"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-06-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-11069"
      },
      {
        "date": "2017-07-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-004681"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201701-424"
      },
      {
        "date": "2025-04-20T01:37:25.860000",
        "db": "NVD",
        "id": "CVE-2017-5243"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201701-424"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Rapid7 Nexpose Vulnerabilities in the use of cryptographic algorithms",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004681"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "encryption problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201701-424"
      }
    ],
    "trust": 0.6
  }
}

CVE-2023-1699 (GCVE-0-2023-1699)

Vulnerability from nvd – Published: 2023-03-30 09:26 – Updated: 2025-02-11 20:12
VLAI?
Title
Rapid7 Nexpose Forced Browsing
Summary
Rapid7 Nexpose versions 6.6.186 and below suffer from a forced browsing vulnerability.  This vulnerability allows an attacker to manipulate URLs to forcefully browse to and access administrative pages. This vulnerability is fixed in version 6.6.187.  
CWE
  • CWE-425 - Direct Request ('Forced Browsing')
Assigner
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 0 , ≤ 6.6.186 (custom)
Create a notification for this product.
Credits
Casey Cooper
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:57:25.055Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20230329/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-1699",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-11T20:12:05.970309Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-11T20:12:14.684Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.186",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Casey Cooper"
        }
      ],
      "datePublic": "2023-03-29T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Rapid7 Nexpose versions 6.6.186 and below suffer from a forced browsing vulnerability.\u0026nbsp; This vulnerability allows an attacker to manipulate URLs to forcefully browse to and access administrative pages. This vulnerability is fixed in version 6.6.187.\u0026nbsp;\u0026nbsp;"
            }
          ],
          "value": "Rapid7 Nexpose versions 6.6.186 and below suffer from a forced browsing vulnerability.\u00a0 This vulnerability allows an attacker to manipulate URLs to forcefully browse to and access administrative pages. This vulnerability is fixed in version 6.6.187.\u00a0\u00a0"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-425",
              "description": "CWE-425 Direct Request (\u0027Forced Browsing\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-30T09:26:13.515Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "url": "https://docs.rapid7.com/release-notes/nexpose/20230329/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Nexpose Forced Browsing",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2023-1699",
    "datePublished": "2023-03-30T09:26:13.515Z",
    "dateReserved": "2023-03-29T14:17:15.354Z",
    "dateUpdated": "2025-02-11T20:12:14.684Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-0681 (GCVE-0-2023-0681)

Vulnerability from nvd – Published: 2023-03-20 17:26 – Updated: 2025-02-26 18:44
VLAI?
Title
Rapid7 Nexpose Uncontrolled URL Redirect
Summary
Rapid7 InsightVM versions 6.6.178 and lower suffers from an open redirect vulnerability, whereby an attacker has the ability to redirect the user to a site of the attacker’s choice using the ‘page’ parameter of the ‘data/console/redirect’ component of the application. This issue was resolved in the February, 2023 release of version 6.6.179. 
CWE
  • CWE-601 - URL Redirection to Untrusted Site ('Open Redirect')
Assigner
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 0 , ≤ 6.6.178 (semver)
Create a notification for this product.
Credits
Beau Taub of 2U, Inc.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:17:50.344Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "release-notes",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20230208/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-0681",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T18:43:51.768864Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-26T18:44:06.211Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.178",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Beau Taub of 2U, Inc."
        }
      ],
      "datePublic": "2023-03-20T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Rapid7 InsightVM versions 6.6.178 and lower suffers from an open redirect vulnerability, whereby an attacker has the ability to redirect the user to a site of the attacker\u2019s choice using the \u2018page\u2019 parameter of the \u2018data/console/redirect\u2019 component of the application. This issue was resolved in the February, 2023 release of version 6.6.179.\u0026nbsp;\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "Rapid7 InsightVM versions 6.6.178 and lower suffers from an open redirect vulnerability, whereby an attacker has the ability to redirect the user to a site of the attacker\u2019s choice using the \u2018page\u2019 parameter of the \u2018data/console/redirect\u2019 component of the application. This issue was resolved in the February, 2023 release of version 6.6.179.\u00a0\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "CWE-601 URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-21T17:47:59.274Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20230208/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Nexpose Uncontrolled URL Redirect",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2023-0681",
    "datePublished": "2023-03-20T17:26:01.588Z",
    "dateReserved": "2023-02-06T14:52:11.265Z",
    "dateUpdated": "2025-02-26T18:44:06.211Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-3913 (GCVE-0-2022-3913)

Vulnerability from nvd – Published: 2023-02-01 21:52 – Updated: 2025-03-26 15:05
VLAI?
Title
Rapid7 Nexpose Certificate Validation Issue
Summary
Rapid7 Nexpose and InsightVM versions 6.6.82 through 6.6.177 fail to validate the certificate of the update server when downloading updates. This failure could allow an attacker in a privileged position on the network to provide their own HTTPS endpoint, or intercept communications to the legitimate endpoint. The attacker would need some pre-existing access to at least one node on the network path between the Rapid7-controlled update server and the Nexpose/InsightVM application, and the ability to either spoof the update server's FQDN or redirect legitimate traffic to the attacker's server in order to exploit this vulnerability. Note that even in this scenario, an attacker could not normally replace an update package with a malicious package, since the update process validates a separate, code-signing certificate, distinct from the HTTPS certificate used for communication. This issue was resolved on February 1, 2023 in update 6.6.178 of Nexpose and InsightVM.
CWE
  • CWE-295 - Improper Certificate Validation
Assigner
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 6.6.82 , < 6.6.178 (semver)
Create a notification for this product.
    Rapid7 InsightVM Affected: 6.6.82 , < 6.6.178 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:20:58.781Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "release-notes",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20230201/"
          },
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.rapid7.com/blog/post/2022/12/07/cve-2022-4261-rapid7-nexpose-update-validation-issue-fixed/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3913",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-26T15:04:59.895760Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-26T15:05:18.697Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.178",
              "status": "affected",
              "version": "6.6.82",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "InsightVM",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.178",
              "status": "affected",
              "version": "6.6.82",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2023-02-01T21:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eRapid7 Nexpose and InsightVM versions 6.6.82 through 6.6.177 fail to validate the certificate of the update server when downloading updates. This failure could allow an attacker in a privileged position on the network to provide their own HTTPS endpoint, or intercept communications to the legitimate endpoint. The attacker would need some pre-existing access to at least one node on the network path between the Rapid7-controlled update server and the Nexpose/InsightVM application, and the ability to either spoof the update server\u0027s FQDN or redirect legitimate traffic to the attacker\u0027s server in order to exploit this vulnerability. Note that even in this scenario, an attacker could not normally replace an update package with a malicious package, since the update process validates a separate, code-signing certificate, distinct from the HTTPS certificate used for communication. This issue was resolved on February 1, 2023 in update 6.6.178 of Nexpose and InsightVM.\u003c/div\u003e\u003c/div\u003e\u003cbr\u003e"
            }
          ],
          "value": "Rapid7 Nexpose and InsightVM versions 6.6.82 through 6.6.177 fail to validate the certificate of the update server when downloading updates. This failure could allow an attacker in a privileged position on the network to provide their own HTTPS endpoint, or intercept communications to the legitimate endpoint. The attacker would need some pre-existing access to at least one node on the network path between the Rapid7-controlled update server and the Nexpose/InsightVM application, and the ability to either spoof the update server\u0027s FQDN or redirect legitimate traffic to the attacker\u0027s server in order to exploit this vulnerability. Note that even in this scenario, an attacker could not normally replace an update package with a malicious package, since the update process validates a separate, code-signing certificate, distinct from the HTTPS certificate used for communication. This issue was resolved on February 1, 2023 in update 6.6.178 of Nexpose and InsightVM.\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-295",
              "description": "CWE-295 Improper Certificate Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-01T21:52:21.959Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20230201/"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.rapid7.com/blog/post/2022/12/07/cve-2022-4261-rapid7-nexpose-update-validation-issue-fixed/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Nexpose Certificate Validation Issue",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2022-3913",
    "datePublished": "2023-02-01T21:52:21.959Z",
    "dateReserved": "2022-11-09T14:48:27.304Z",
    "dateUpdated": "2025-03-26T15:05:18.697Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-4261 (GCVE-0-2022-4261)

Vulnerability from nvd – Published: 2022-12-07 00:00 – Updated: 2025-04-14 17:57
VLAI?
Title
Rapid7 Nexpose Update Validation Issue
Summary
Rapid7 Nexpose and InsightVM versions prior to 6.6.172 failed to reliably validate the authenticity of update contents. This failure could allow an attacker to provide a malicious update and alter the functionality of Rapid7 Nexpose. The attacker would need some pre-existing mechanism to provide a malicious update, either through a social engineering effort, privileged access to replace downloaded updates in transit, or by performing an Attacker-in-the-Middle attack on the update service itself.
CWE
  • CWE-494 - Download of Code Without Integrity Check
Assigner
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 0 , ≤ 6.6.171 (semver)
Create a notification for this product.
    Rapid7 InsightVM Affected: 0 , ≤ 6.6.171 (semver)
Create a notification for this product.
Credits
Emmett Kelly, Rapid7 Principal Software Engineer
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:34:49.938Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20221207/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.rapid7.com/blog/post/2022/12/7/cve-2022-4261-rapid7-nexpose-update-validation-issue-fixed"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/insightvm/20221207/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-4261",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T15:22:13.145687Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-14T17:57:38.662Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.171",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "InsightVM",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.171",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Emmett Kelly, Rapid7 Principal Software Engineer"
        }
      ],
      "datePublic": "2022-12-07T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eRapid7 Nexpose and InsightVM versions prior to 6.6.172 failed to reliably validate the authenticity of update contents. This failure could allow an attacker to provide a malicious update and alter the functionality of Rapid7 Nexpose. The attacker would need some pre-existing mechanism to provide a malicious update, either through a social engineering effort, privileged access to replace downloaded updates in transit, or by performing an Attacker-in-the-Middle attack on the update service itself.\u003c/p\u003e"
            }
          ],
          "value": "Rapid7 Nexpose and InsightVM versions prior to 6.6.172 failed to reliably validate the authenticity of update contents. This failure could allow an attacker to provide a malicious update and alter the functionality of Rapid7 Nexpose. The attacker would need some pre-existing mechanism to provide a malicious update, either through a social engineering effort, privileged access to replace downloaded updates in transit, or by performing an Attacker-in-the-Middle attack on the update service itself.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-494",
              "description": "CWE-494 Download of Code Without Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-07T19:24:33.157Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "url": "https://docs.rapid7.com/release-notes/nexpose/20221207/"
        },
        {
          "url": "https://www.rapid7.com/blog/post/2022/12/7/cve-2022-4261-rapid7-nexpose-update-validation-issue-fixed"
        },
        {
          "url": "https://docs.rapid7.com/release-notes/insightvm/20221207/"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Rapid7 Nexpose Update Validation Issue",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2022-4261",
    "datePublished": "2022-12-07T00:00:00.000Z",
    "dateReserved": "2022-12-01T00:00:00.000Z",
    "dateUpdated": "2025-04-14T17:57:38.662Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-0758 (GCVE-0-2022-0758)

Vulnerability from nvd – Published: 2022-03-17 22:30 – Updated: 2024-09-16 20:26
VLAI?
Title
Rapid7 Nexpose Reflected XSS
Summary
Rapid7 Nexpose versions 6.6.129 and earlier suffer from a reflected cross site scripting vulnerability, within the shared scan configuration component of the tool. With this vulnerability an attacker could pass literal values as the test credentials, providing the opportunity for a potential XSS attack. This issue is fixed in Rapid7 Nexpose version 6.6.130.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 6.6.129 , ≤ 6.6.129 (custom)
Create a notification for this product.
Credits
Aleksey Solovev
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T23:40:03.529Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20220309/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.129",
              "status": "affected",
              "version": "6.6.129",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Aleksey Solovev"
        }
      ],
      "datePublic": "2022-03-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Rapid7 Nexpose versions 6.6.129 and earlier suffer from a reflected cross site scripting vulnerability, within the shared scan configuration component of the tool. With this vulnerability an attacker could pass literal values as the test credentials, providing the opportunity for a potential XSS attack. This issue is fixed in Rapid7 Nexpose version 6.6.130."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-17T22:30:19",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20220309/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Nexpose Reflected XSS",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2022-03-09T00:00:00.000Z",
          "ID": "CVE-2022-0758",
          "STATE": "PUBLIC",
          "TITLE": "Rapid7 Nexpose Reflected XSS"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "\u003c=",
                            "version_name": "6.6.129",
                            "version_value": "6.6.129"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "configuration": [],
        "credit": [
          {
            "lang": "eng",
            "value": "Aleksey Solovev"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose versions 6.6.129 and earlier suffer from a reflected cross site scripting vulnerability, within the shared scan configuration component of the tool. With this vulnerability an attacker could pass literal values as the test credentials, providing the opportunity for a potential XSS attack. This issue is fixed in Rapid7 Nexpose version 6.6.130."
            }
          ]
        },
        "exploit": [],
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.rapid7.com/release-notes/nexpose/20220309/",
              "refsource": "CONFIRM",
              "url": "https://docs.rapid7.com/release-notes/nexpose/20220309/"
            }
          ]
        },
        "solution": [],
        "source": {
          "advisory": "",
          "defect": [],
          "discovery": "UNKNOWN"
        },
        "work_around": []
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2022-0758",
    "datePublished": "2022-03-17T22:30:19.550927Z",
    "dateReserved": "2022-02-24T00:00:00",
    "dateUpdated": "2024-09-16T20:26:23.589Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-0757 (GCVE-0-2022-0757)

Vulnerability from nvd – Published: 2022-03-17 22:30 – Updated: 2024-09-16 17:48
VLAI?
Title
Rapid7 Nexpose SQL Injection
Summary
Rapid7 Nexpose versions 6.6.93 and earlier are susceptible to an SQL Injection vulnerability, whereby valid search operators are not defined. This lack of validation can allow a logged-in, authenticated attacker to manipulate the "ANY" and "OR" operators in the SearchCriteria and inject SQL code. This issue was fixed in Rapid7 Nexpose version 6.6.129.
CWE
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 6.6.93 , < 6.6.93 (custom)
Create a notification for this product.
Credits
Aleksey Solovev
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T23:40:03.752Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20220302/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.93",
              "status": "affected",
              "version": "6.6.93",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Aleksey Solovev"
        }
      ],
      "datePublic": "2022-03-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Rapid7 Nexpose versions 6.6.93 and earlier are susceptible to an SQL Injection vulnerability, whereby valid search operators are not defined. This lack of validation can allow a logged-in, authenticated attacker to manipulate the \"ANY\" and \"OR\" operators in the SearchCriteria and inject SQL code. This issue was fixed in Rapid7 Nexpose version 6.6.129."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 SQL Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-04T14:35:09",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20220302/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Nexpose SQL Injection",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2022-03-02T00:00:00.000Z",
          "ID": "CVE-2022-0757",
          "STATE": "PUBLIC",
          "TITLE": "Rapid7 Nexpose SQL Injection"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "\u003c",
                            "version_name": "6.6.93",
                            "version_value": "6.6.93"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "configuration": [],
        "credit": [
          {
            "lang": "eng",
            "value": "Aleksey Solovev"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose versions 6.6.93 and earlier are susceptible to an SQL Injection vulnerability, whereby valid search operators are not defined. This lack of validation can allow a logged-in, authenticated attacker to manipulate the \"ANY\" and \"OR\" operators in the SearchCriteria and inject SQL code. This issue was fixed in Rapid7 Nexpose version 6.6.129."
            }
          ]
        },
        "exploit": [],
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89 SQL Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.rapid7.com/release-notes/nexpose/20220302/",
              "refsource": "CONFIRM",
              "url": "https://docs.rapid7.com/release-notes/nexpose/20220302/"
            }
          ]
        },
        "solution": [],
        "source": {
          "advisory": "",
          "defect": [],
          "discovery": "UNKNOWN"
        },
        "work_around": []
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2022-0757",
    "datePublished": "2022-03-17T22:30:18.220701Z",
    "dateReserved": "2022-02-24T00:00:00",
    "dateUpdated": "2024-09-16T17:48:14.153Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5640 (GCVE-0-2019-5640)

Vulnerability from nvd – Published: 2021-11-22 16:35 – Updated: 2024-09-17 00:15
VLAI?
Title
Rapid7 Nexpose Information Disclosure after logout
Summary
Rapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user's session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user
CWE
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 1.0 , ≤ 6.6.114 (custom)
Create a notification for this product.
Credits
Ashutosh Barot
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:01:52.022Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20211117/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.114",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Ashutosh Barot"
        }
      ],
      "datePublic": "2021-11-17T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eRapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user\u0027s session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user\u003c/p\u003e"
            }
          ],
          "value": "Rapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user\u0027s session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-10T10:10:18.015Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20211117/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Nexpose Information Disclosure after logout",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2021-11-17T15:05:00.000Z",
          "ID": "CVE-2019-5640",
          "STATE": "PUBLIC",
          "TITLE": "Rapid7 Nexpose Information Disclosure after logout"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "6.6.114",
                            "version_value": "6.6.114"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user\u0027s session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200 Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.rapid7.com/release-notes/nexpose/20211117/",
              "refsource": "CONFIRM",
              "url": "https://docs.rapid7.com/release-notes/nexpose/20211117/"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2019-5640",
    "datePublished": "2021-11-22T16:35:10.539066Z",
    "dateReserved": "2019-01-07T00:00:00",
    "dateUpdated": "2024-09-17T00:15:52.087Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31868 (GCVE-0-2021-31868)

Vulnerability from nvd – Published: 2021-08-19 15:25 – Updated: 2024-09-17 01:16
VLAI?
Title
Rapid7 Nexpose Security Console Ticket Access Authentication Vulnerability
Summary
Rapid7 Nexpose version 6.6.95 and earlier allows authenticated users of the Security Console to view and edit any ticket in the legacy ticketing feature, regardless of the assignment of the ticket. This issue was resolved in version 6.6.96, released on August 4, 2021.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 6.6.95 , ≤ 6.6.95 (custom)
Create a notification for this product.
Credits
Reda El Hachloufi
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.651Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20210804/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.95",
              "status": "affected",
              "version": "6.6.95",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Reda El Hachloufi"
        }
      ],
      "datePublic": "2021-08-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Rapid7 Nexpose version 6.6.95 and earlier allows authenticated users of the Security Console to view and edit any ticket in the legacy ticketing feature, regardless of the assignment of the ticket. This issue was resolved in version 6.6.96, released on August 4, 2021."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-19T15:25:10",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20210804/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Rapid7 Nexpose Security Console Ticket Access Authentication Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2021-08-04T17:00:00.000Z",
          "ID": "CVE-2021-31868",
          "STATE": "PUBLIC",
          "TITLE": "Rapid7 Nexpose Security Console Ticket Access Authentication Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "6.6.95",
                            "version_value": "6.6.95"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Reda El Hachloufi"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose version 6.6.95 and earlier allows authenticated users of the Security Console to view and edit any ticket in the legacy ticketing feature, regardless of the assignment of the ticket. This issue was resolved in version 6.6.96, released on August 4, 2021."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306 Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.rapid7.com/release-notes/nexpose/20210804/",
              "refsource": "CONFIRM",
              "url": "https://docs.rapid7.com/release-notes/nexpose/20210804/"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2021-31868",
    "datePublished": "2021-08-19T15:25:10.545322Z",
    "dateReserved": "2021-04-28T00:00:00",
    "dateUpdated": "2024-09-17T01:16:12.557Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-3535 (GCVE-0-2021-3535)

Vulnerability from nvd – Published: 2021-06-16 01:40 – Updated: 2024-09-16 23:10
VLAI?
Summary
Rapid7 Nexpose is vulnerable to a non-persistent cross-site scripting vulnerability affecting the Security Console's Filtered Asset Search feature. A specific search criterion and operator combination in Filtered Asset Search could have allowed a user to pass code through the provided search field. This issue affects version 6.6.80 and prior, and is fixed in 6.6.81. If your Security Console currently falls on or within this affected version range, ensure that you update your Security Console to the latest version.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Rapid7 Nexpose Affected: unspecified , < 6.6.81 (custom)
Create a notification for this product.
Credits
This issue was discovered and reported by Philipp Behmer.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:01:07.112Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20210505/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rapid7 Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.81",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This issue was discovered and reported by Philipp Behmer."
        }
      ],
      "datePublic": "2021-05-06T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Rapid7 Nexpose is vulnerable to a non-persistent cross-site scripting vulnerability affecting the Security Console\u0027s Filtered Asset Search feature. A specific search criterion and operator combination in Filtered Asset Search could have allowed a user to pass code through the provided search field. This issue affects version 6.6.80 and prior, and is fixed in 6.6.81. If your Security Console currently falls on or within this affected version range, ensure that you update your Security Console to the latest version."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-16T01:40:12",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20210505/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2021-05-06T00:00:00.000Z",
          "ID": "CVE-2021-3535",
          "STATE": "PUBLIC",
          "TITLE": ""
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rapid7 Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "\u003c",
                            "version_name": "",
                            "version_value": "6.6.81"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "configuration": [],
        "credit": [
          {
            "lang": "eng",
            "value": "This issue was discovered and reported by Philipp Behmer."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose is vulnerable to a non-persistent cross-site scripting vulnerability affecting the Security Console\u0027s Filtered Asset Search feature. A specific search criterion and operator combination in Filtered Asset Search could have allowed a user to pass code through the provided search field. This issue affects version 6.6.80 and prior, and is fixed in 6.6.81. If your Security Console currently falls on or within this affected version range, ensure that you update your Security Console to the latest version."
            }
          ]
        },
        "exploit": [],
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.rapid7.com/release-notes/nexpose/20210505/",
              "refsource": "CONFIRM",
              "url": "https://docs.rapid7.com/release-notes/nexpose/20210505/"
            }
          ]
        },
        "solution": [],
        "source": {
          "advisory": "",
          "defect": [],
          "discovery": "UNKNOWN"
        },
        "work_around": []
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2021-3535",
    "datePublished": "2021-06-16T01:40:12.586548Z",
    "dateReserved": "2021-05-05T00:00:00",
    "dateUpdated": "2024-09-16T23:10:39.986Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7383 (GCVE-0-2020-7383)

Vulnerability from nvd – Published: 2020-10-14 19:45 – Updated: 2024-09-16 20:31
VLAI?
Title
SQL Injection in Rapid7 Nexpose
Summary
A SQL Injection issue in Rapid7 Nexpose version prior to 6.6.49 that may have allowed an authenticated user with a low permission level to access resources & make changes they should not have been able to access.
CWE
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: unspecified , < 6.6.49 (custom)
Create a notification for this product.
Credits
This issue was discovered and reported by Mikhail Klyuchnikov of Positive Technologies.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:25:49.045Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.49"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.49",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This issue was discovered and reported by Mikhail Klyuchnikov of Positive Technologies."
        }
      ],
      "datePublic": "2020-10-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A SQL Injection issue in Rapid7 Nexpose version prior to 6.6.49 that may have allowed an authenticated user with a low permission level to access resources \u0026 make changes they should not have been able to access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 SQL Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-10-14T19:45:15",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.49"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "SQL Injection in Rapid7 Nexpose",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2020-10-14T11:23:00.000Z",
          "ID": "CVE-2020-7383",
          "STATE": "PUBLIC",
          "TITLE": "SQL Injection in Rapid7 Nexpose"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "6.6.49"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This issue was discovered and reported by Mikhail Klyuchnikov of Positive Technologies."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A SQL Injection issue in Rapid7 Nexpose version prior to 6.6.49 that may have allowed an authenticated user with a low permission level to access resources \u0026 make changes they should not have been able to access."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89 SQL Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.49",
              "refsource": "MISC",
              "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.49"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2020-7383",
    "datePublished": "2020-10-14T19:45:15.276787Z",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-09-16T20:31:39.664Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7382 (GCVE-0-2020-7382)

Vulnerability from nvd – Published: 2020-09-03 13:55 – Updated: 2024-08-04 09:25
VLAI?
Title
Unquoted Path in Rapid7 Nexpose Installer
Summary
Rapid7 Nexpose installer version prior to 6.6.40 contains an Unquoted Search Path which may allow an attacker on the local machine to insert an arbitrary file into the executable path. This issue affects: Rapid7 Nexpose versions prior to 6.6.40.
CWE
  • CWE-428 - Unquoted Search Path or Element
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: unspecified , < 6.6.40 (custom)
Create a notification for this product.
Credits
This issue was discovered and reported by Angelo D'Amato.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:25:49.039Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.40",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This issue was discovered and reported by Angelo D\u0027Amato. "
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Rapid7 Nexpose installer version prior to 6.6.40 contains an Unquoted Search Path which may allow an attacker on the local machine to insert an arbitrary file into the executable path. This issue affects: Rapid7 Nexpose versions prior to 6.6.40."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-428",
              "description": "CWE-428 Unquoted Search Path or Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-09-03T13:55:26",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Unquoted Path in Rapid7 Nexpose Installer",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "ID": "CVE-2020-7382",
          "STATE": "PUBLIC",
          "TITLE": "Unquoted Path in Rapid7 Nexpose Installer"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "6.6.40"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This issue was discovered and reported by Angelo D\u0027Amato. "
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose installer version prior to 6.6.40 contains an Unquoted Search Path which may allow an attacker on the local machine to insert an arbitrary file into the executable path. This issue affects: Rapid7 Nexpose versions prior to 6.6.40."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-428 Unquoted Search Path or Element"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40",
              "refsource": "MISC",
              "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2020-7382",
    "datePublished": "2020-09-03T13:55:26",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:25:49.039Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7381 (GCVE-0-2020-7381)

Vulnerability from nvd – Published: 2020-09-03 13:55 – Updated: 2024-08-04 09:25
VLAI?
Title
Code Injection in Rapid7 Nexpose Installer
Summary
In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: unspecified , < 6.6.40 (custom)
Create a notification for this product.
Credits
This issue was discovered and reported by Mishra Dhiraj.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:25:49.053Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.40",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This issue was discovered and reported by Mishra Dhiraj. "
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-09-03T13:55:25",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Code Injection in Rapid7 Nexpose Installer",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "ID": "CVE-2020-7381",
          "STATE": "PUBLIC",
          "TITLE": "Code Injection in Rapid7 Nexpose Installer"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "6.6.40"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This issue was discovered and reported by Mishra Dhiraj. "
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40",
              "refsource": "MISC",
              "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2020-7381",
    "datePublished": "2020-09-03T13:55:25",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:25:49.053Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-6494 (GCVE-0-2012-6494)

Vulnerability from nvd – Published: 2020-01-25 18:41 – Updated: 2024-08-06 21:28
VLAI?
Summary
Rapid7 Nexpose before 5.5.4 contains a session hijacking vulnerability which allows remote attackers to capture a user's session and gain unauthorized access.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T21:28:39.951Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "57150",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/57150"
          },
          {
            "name": "80982",
            "tags": [
              "vdb-entry",
              "x_refsource_XF",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/80982"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-01-05T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Rapid7 Nexpose before 5.5.4 contains a session hijacking vulnerability which allows remote attackers to capture a user\u0027s session and gain unauthorized access."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-25T18:41:34",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "57150",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/57150"
        },
        {
          "name": "80982",
          "tags": [
            "vdb-entry",
            "x_refsource_XF"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/80982"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2012-6494",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose before 5.5.4 contains a session hijacking vulnerability which allows remote attackers to capture a user\u0027s session and gain unauthorized access."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "57150",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/57150"
            },
            {
              "name": "80982",
              "refsource": "XF",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/80982"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2012-6494",
    "datePublished": "2020-01-25T18:41:34",
    "dateReserved": "2013-01-02T00:00:00",
    "dateUpdated": "2024-08-06T21:28:39.951Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5638 (GCVE-0-2019-5638)

Vulnerability from nvd – Published: 2019-08-21 19:36 – Updated: 2024-09-16 22:25
VLAI?
Title
Rapid7 Nexpose Insufficient Session Management
Summary
Rapid7 Nexpose versions 6.5.50 and prior suffer from insufficient session expiration when an administrator performs a security relevant edit on an existing, logged on user. For example, if a user's password is changed by an administrator due to an otherwise unrelated credential leak, that user account's current session is still valid after the password change, potentially allowing the attacker who originally compromised the credential to remain logged in and able to cause further damage.
CWE
  • CWE-613 - Insufficient Session Expiration
Assigner
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: unspecified , ≤ 6.5.50 (custom)
Create a notification for this product.
Credits
This issue was discovered, and reported to Rapid7, by independent researcher Ashutosh Barot. It is being disclosed in accordance with Rapid7's vulnerability disclosure policy (https://www.rapid7.com/disclosure/).
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:01:52.192Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://help.rapid7.com/nexpose/en-us/release-notes/archive/2019/02/"
          },
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/insightvm/enable-insightvm-platform-login"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.5.50",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "This issue was discovered, and reported to Rapid7, by independent researcher Ashutosh Barot. It is being disclosed in accordance with Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
        }
      ],
      "datePublic": "2019-08-14T23:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eRapid7 Nexpose versions 6.5.50 and prior suffer from insufficient session expiration when an administrator performs a security relevant edit on an existing, logged on user. For example, if a user\u0027s password is changed by an administrator due to an otherwise unrelated credential leak, that user account\u0027s current session is still valid after the password change, potentially allowing the attacker who originally compromised the credential to remain logged in and able to cause further damage.\u003c/p\u003e"
            }
          ],
          "value": "Rapid7 Nexpose versions 6.5.50 and prior suffer from insufficient session expiration when an administrator performs a security relevant edit on an existing, logged on user. For example, if a user\u0027s password is changed by an administrator due to an otherwise unrelated credential leak, that user account\u0027s current session is still valid after the password change, potentially allowing the attacker who originally compromised the credential to remain logged in and able to cause further damage."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-613",
              "description": "CWE-613 Insufficient Session Expiration",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-09T15:34:58.318Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://help.rapid7.com/nexpose/en-us/release-notes/archive/2019/02/"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://docs.rapid7.com/insightvm/enable-insightvm-platform-login"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThis issue is resolved in versions 6.5.51 and later of Rapid7 Nexpose.\u003c/p\u003e"
            }
          ],
          "value": "This issue is resolved in versions 6.5.51 and later of Rapid7 Nexpose."
        }
      ],
      "source": {
        "advisory": "R7-2018-50",
        "discovery": "EXTERNAL"
      },
      "title": "Rapid7 Nexpose Insufficient Session Management",
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2019-08-15T15:00:00.000Z",
          "ID": "CVE-2019-5638",
          "STATE": "PUBLIC",
          "TITLE": "Rapid7 Nexpose Insufficient Session Management"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "6.5.50"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This issue was discovered, and reported to Rapid7, by independent researcher Ashutosh Barot. It is being disclosed in accordance with Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose versions 6.5.50 and prior suffer from insufficient session expiration when an administrator performs a security relevant edit on an existing, logged on user. For example, if a user\u0027s password is changed by an administrator due to an otherwise unrelated credential leak, that user account\u0027s current session is still valid after the password change, potentially allowing the attacker who originally compromised the credential to remain logged in and able to cause further damage."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-613 Insufficient Session Expiration"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://help.rapid7.com/nexpose/en-us/release-notes/archive/2019/02/",
              "refsource": "CONFIRM",
              "url": "https://help.rapid7.com/nexpose/en-us/release-notes/archive/2019/02/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "This issue is resolved in versions 6.5.51 and later of Rapid7 Nexpose."
          }
        ],
        "source": {
          "advisory": "R7-2018-50",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2019-5638",
    "datePublished": "2019-08-21T19:36:25.675225Z",
    "dateReserved": "2019-01-07T00:00:00",
    "dateUpdated": "2024-09-16T22:25:03.188Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5630 (GCVE-0-2019-5630)

Vulnerability from nvd – Published: 2019-07-03 17:00 – Updated: 2024-08-04 20:01
VLAI?
Title
Rapid7 Nexpose/InsightVM Security Console CSRF
Summary
A Cross-Site Request Forgery (CSRF) vulnerability was found in Rapid7 Nexpose InsightVM Security Console versions 6.5.0 through 6.5.68. This issue allows attackers to exploit CSRF vulnerabilities on API endpoints using Flash to circumvent a cross-domain pre-flight OPTIONS request.
CWE
  • Cross-Site Request Forgery
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose/InsightVM Security Console Affected: 6.5.0 through 6.5.68
Create a notification for this product.
Credits
Thanks to Rodney Beede of Rackspace (https://www.rodneybeede.com/) for finding this issue and reporting it to Rapid7. It is being disclosed in accordance Rapid7's vulnerability disclosure policy (https://www.rapid7.com/disclosure/).
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:01:51.880Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://help.rapid7.com/nexpose/en-us/release-notes#6.5.69"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose/InsightVM Security Console",
          "vendor": "Rapid7",
          "versions": [
            {
              "status": "affected",
              "version": "6.5.0 through 6.5.68"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Thanks to Rodney Beede of Rackspace (https://www.rodneybeede.com/) for finding this issue and reporting it to Rapid7. It is being disclosed in accordance Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/).\n"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A Cross-Site Request Forgery (CSRF) vulnerability was found in Rapid7 Nexpose InsightVM Security Console versions 6.5.0 through 6.5.68. This issue allows attackers to exploit CSRF vulnerabilities on API endpoints using Flash to circumvent a cross-domain pre-flight OPTIONS request."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "In order to exploit this vulnerability, an attacker would have had to create and host a vulnerable .swf file on their own web server and have the user visit the page that hosts this file. Once the user visits this page, the .swf would run in-browser and cause a 307 redirect, which in turn would direct the victim to the API endpoint and make the CSRF request."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Cross-Site Request Forgery ",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-03T17:00:55",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://help.rapid7.com/nexpose/en-us/release-notes#6.5.69"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "This issue minimally affects Security Console versions 6.5.0 through 6.5.68. If your Security Console currently falls on or within this affected version range, ensure that you update your Security Console to 6.5.69 (or later if available)."
        }
      ],
      "source": {
        "advisory": "R7-2019-17",
        "discovery": "USER"
      },
      "title": "Rapid7 Nexpose/InsightVM Security Console CSRF",
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "ID": "CVE-2019-5630",
          "STATE": "PUBLIC",
          "TITLE": "Rapid7 Nexpose/InsightVM Security Console CSRF"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose/InsightVM Security Console",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "6.5.0 through 6.5.68"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Thanks to Rodney Beede of Rackspace (https://www.rodneybeede.com/) for finding this issue and reporting it to Rapid7. It is being disclosed in accordance Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/).\n"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Cross-Site Request Forgery (CSRF) vulnerability was found in Rapid7 Nexpose InsightVM Security Console versions 6.5.0 through 6.5.68. This issue allows attackers to exploit CSRF vulnerabilities on API endpoints using Flash to circumvent a cross-domain pre-flight OPTIONS request."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "In order to exploit this vulnerability, an attacker would have had to create and host a vulnerable .swf file on their own web server and have the user visit the page that hosts this file. Once the user visits this page, the .swf would run in-browser and cause a 307 redirect, which in turn would direct the victim to the API endpoint and make the CSRF request."
          }
        ],
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cross-Site Request Forgery "
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://help.rapid7.com/nexpose/en-us/release-notes#6.5.69",
              "refsource": "CONFIRM",
              "url": "https://help.rapid7.com/nexpose/en-us/release-notes#6.5.69"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "This issue minimally affects Security Console versions 6.5.0 through 6.5.68. If your Security Console currently falls on or within this affected version range, ensure that you update your Security Console to 6.5.69 (or later if available)."
          }
        ],
        "source": {
          "advisory": "R7-2019-17",
          "discovery": "USER"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2019-5630",
    "datePublished": "2019-07-03T17:00:55",
    "dateReserved": "2019-01-07T00:00:00",
    "dateUpdated": "2024-08-04T20:01:51.880Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-1699 (GCVE-0-2023-1699)

Vulnerability from cvelistv5 – Published: 2023-03-30 09:26 – Updated: 2025-02-11 20:12
VLAI?
Title
Rapid7 Nexpose Forced Browsing
Summary
Rapid7 Nexpose versions 6.6.186 and below suffer from a forced browsing vulnerability.  This vulnerability allows an attacker to manipulate URLs to forcefully browse to and access administrative pages. This vulnerability is fixed in version 6.6.187.  
CWE
  • CWE-425 - Direct Request ('Forced Browsing')
Assigner
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 0 , ≤ 6.6.186 (custom)
Create a notification for this product.
Credits
Casey Cooper
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:57:25.055Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20230329/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-1699",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-11T20:12:05.970309Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-11T20:12:14.684Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.186",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Casey Cooper"
        }
      ],
      "datePublic": "2023-03-29T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Rapid7 Nexpose versions 6.6.186 and below suffer from a forced browsing vulnerability.\u0026nbsp; This vulnerability allows an attacker to manipulate URLs to forcefully browse to and access administrative pages. This vulnerability is fixed in version 6.6.187.\u0026nbsp;\u0026nbsp;"
            }
          ],
          "value": "Rapid7 Nexpose versions 6.6.186 and below suffer from a forced browsing vulnerability.\u00a0 This vulnerability allows an attacker to manipulate URLs to forcefully browse to and access administrative pages. This vulnerability is fixed in version 6.6.187.\u00a0\u00a0"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-425",
              "description": "CWE-425 Direct Request (\u0027Forced Browsing\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-30T09:26:13.515Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "url": "https://docs.rapid7.com/release-notes/nexpose/20230329/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Nexpose Forced Browsing",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2023-1699",
    "datePublished": "2023-03-30T09:26:13.515Z",
    "dateReserved": "2023-03-29T14:17:15.354Z",
    "dateUpdated": "2025-02-11T20:12:14.684Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-0681 (GCVE-0-2023-0681)

Vulnerability from cvelistv5 – Published: 2023-03-20 17:26 – Updated: 2025-02-26 18:44
VLAI?
Title
Rapid7 Nexpose Uncontrolled URL Redirect
Summary
Rapid7 InsightVM versions 6.6.178 and lower suffers from an open redirect vulnerability, whereby an attacker has the ability to redirect the user to a site of the attacker’s choice using the ‘page’ parameter of the ‘data/console/redirect’ component of the application. This issue was resolved in the February, 2023 release of version 6.6.179. 
CWE
  • CWE-601 - URL Redirection to Untrusted Site ('Open Redirect')
Assigner
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 0 , ≤ 6.6.178 (semver)
Create a notification for this product.
Credits
Beau Taub of 2U, Inc.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T05:17:50.344Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "release-notes",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20230208/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-0681",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T18:43:51.768864Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-26T18:44:06.211Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.178",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Beau Taub of 2U, Inc."
        }
      ],
      "datePublic": "2023-03-20T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Rapid7 InsightVM versions 6.6.178 and lower suffers from an open redirect vulnerability, whereby an attacker has the ability to redirect the user to a site of the attacker\u2019s choice using the \u2018page\u2019 parameter of the \u2018data/console/redirect\u2019 component of the application. This issue was resolved in the February, 2023 release of version 6.6.179.\u0026nbsp;\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "Rapid7 InsightVM versions 6.6.178 and lower suffers from an open redirect vulnerability, whereby an attacker has the ability to redirect the user to a site of the attacker\u2019s choice using the \u2018page\u2019 parameter of the \u2018data/console/redirect\u2019 component of the application. This issue was resolved in the February, 2023 release of version 6.6.179.\u00a0\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "CWE-601 URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-21T17:47:59.274Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20230208/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Nexpose Uncontrolled URL Redirect",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2023-0681",
    "datePublished": "2023-03-20T17:26:01.588Z",
    "dateReserved": "2023-02-06T14:52:11.265Z",
    "dateUpdated": "2025-02-26T18:44:06.211Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-3913 (GCVE-0-2022-3913)

Vulnerability from cvelistv5 – Published: 2023-02-01 21:52 – Updated: 2025-03-26 15:05
VLAI?
Title
Rapid7 Nexpose Certificate Validation Issue
Summary
Rapid7 Nexpose and InsightVM versions 6.6.82 through 6.6.177 fail to validate the certificate of the update server when downloading updates. This failure could allow an attacker in a privileged position on the network to provide their own HTTPS endpoint, or intercept communications to the legitimate endpoint. The attacker would need some pre-existing access to at least one node on the network path between the Rapid7-controlled update server and the Nexpose/InsightVM application, and the ability to either spoof the update server's FQDN or redirect legitimate traffic to the attacker's server in order to exploit this vulnerability. Note that even in this scenario, an attacker could not normally replace an update package with a malicious package, since the update process validates a separate, code-signing certificate, distinct from the HTTPS certificate used for communication. This issue was resolved on February 1, 2023 in update 6.6.178 of Nexpose and InsightVM.
CWE
  • CWE-295 - Improper Certificate Validation
Assigner
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 6.6.82 , < 6.6.178 (semver)
Create a notification for this product.
    Rapid7 InsightVM Affected: 6.6.82 , < 6.6.178 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:20:58.781Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "release-notes",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20230201/"
          },
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.rapid7.com/blog/post/2022/12/07/cve-2022-4261-rapid7-nexpose-update-validation-issue-fixed/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3913",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-26T15:04:59.895760Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-26T15:05:18.697Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.178",
              "status": "affected",
              "version": "6.6.82",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "InsightVM",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.178",
              "status": "affected",
              "version": "6.6.82",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2023-02-01T21:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eRapid7 Nexpose and InsightVM versions 6.6.82 through 6.6.177 fail to validate the certificate of the update server when downloading updates. This failure could allow an attacker in a privileged position on the network to provide their own HTTPS endpoint, or intercept communications to the legitimate endpoint. The attacker would need some pre-existing access to at least one node on the network path between the Rapid7-controlled update server and the Nexpose/InsightVM application, and the ability to either spoof the update server\u0027s FQDN or redirect legitimate traffic to the attacker\u0027s server in order to exploit this vulnerability. Note that even in this scenario, an attacker could not normally replace an update package with a malicious package, since the update process validates a separate, code-signing certificate, distinct from the HTTPS certificate used for communication. This issue was resolved on February 1, 2023 in update 6.6.178 of Nexpose and InsightVM.\u003c/div\u003e\u003c/div\u003e\u003cbr\u003e"
            }
          ],
          "value": "Rapid7 Nexpose and InsightVM versions 6.6.82 through 6.6.177 fail to validate the certificate of the update server when downloading updates. This failure could allow an attacker in a privileged position on the network to provide their own HTTPS endpoint, or intercept communications to the legitimate endpoint. The attacker would need some pre-existing access to at least one node on the network path between the Rapid7-controlled update server and the Nexpose/InsightVM application, and the ability to either spoof the update server\u0027s FQDN or redirect legitimate traffic to the attacker\u0027s server in order to exploit this vulnerability. Note that even in this scenario, an attacker could not normally replace an update package with a malicious package, since the update process validates a separate, code-signing certificate, distinct from the HTTPS certificate used for communication. This issue was resolved on February 1, 2023 in update 6.6.178 of Nexpose and InsightVM.\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-295",
              "description": "CWE-295 Improper Certificate Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-01T21:52:21.959Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20230201/"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.rapid7.com/blog/post/2022/12/07/cve-2022-4261-rapid7-nexpose-update-validation-issue-fixed/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Nexpose Certificate Validation Issue",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2022-3913",
    "datePublished": "2023-02-01T21:52:21.959Z",
    "dateReserved": "2022-11-09T14:48:27.304Z",
    "dateUpdated": "2025-03-26T15:05:18.697Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-4261 (GCVE-0-2022-4261)

Vulnerability from cvelistv5 – Published: 2022-12-07 00:00 – Updated: 2025-04-14 17:57
VLAI?
Title
Rapid7 Nexpose Update Validation Issue
Summary
Rapid7 Nexpose and InsightVM versions prior to 6.6.172 failed to reliably validate the authenticity of update contents. This failure could allow an attacker to provide a malicious update and alter the functionality of Rapid7 Nexpose. The attacker would need some pre-existing mechanism to provide a malicious update, either through a social engineering effort, privileged access to replace downloaded updates in transit, or by performing an Attacker-in-the-Middle attack on the update service itself.
CWE
  • CWE-494 - Download of Code Without Integrity Check
Assigner
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 0 , ≤ 6.6.171 (semver)
Create a notification for this product.
    Rapid7 InsightVM Affected: 0 , ≤ 6.6.171 (semver)
Create a notification for this product.
Credits
Emmett Kelly, Rapid7 Principal Software Engineer
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:34:49.938Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20221207/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.rapid7.com/blog/post/2022/12/7/cve-2022-4261-rapid7-nexpose-update-validation-issue-fixed"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/insightvm/20221207/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-4261",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T15:22:13.145687Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-14T17:57:38.662Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.171",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "InsightVM",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.171",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Emmett Kelly, Rapid7 Principal Software Engineer"
        }
      ],
      "datePublic": "2022-12-07T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eRapid7 Nexpose and InsightVM versions prior to 6.6.172 failed to reliably validate the authenticity of update contents. This failure could allow an attacker to provide a malicious update and alter the functionality of Rapid7 Nexpose. The attacker would need some pre-existing mechanism to provide a malicious update, either through a social engineering effort, privileged access to replace downloaded updates in transit, or by performing an Attacker-in-the-Middle attack on the update service itself.\u003c/p\u003e"
            }
          ],
          "value": "Rapid7 Nexpose and InsightVM versions prior to 6.6.172 failed to reliably validate the authenticity of update contents. This failure could allow an attacker to provide a malicious update and alter the functionality of Rapid7 Nexpose. The attacker would need some pre-existing mechanism to provide a malicious update, either through a social engineering effort, privileged access to replace downloaded updates in transit, or by performing an Attacker-in-the-Middle attack on the update service itself.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-494",
              "description": "CWE-494 Download of Code Without Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-07T19:24:33.157Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "url": "https://docs.rapid7.com/release-notes/nexpose/20221207/"
        },
        {
          "url": "https://www.rapid7.com/blog/post/2022/12/7/cve-2022-4261-rapid7-nexpose-update-validation-issue-fixed"
        },
        {
          "url": "https://docs.rapid7.com/release-notes/insightvm/20221207/"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Rapid7 Nexpose Update Validation Issue",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2022-4261",
    "datePublished": "2022-12-07T00:00:00.000Z",
    "dateReserved": "2022-12-01T00:00:00.000Z",
    "dateUpdated": "2025-04-14T17:57:38.662Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-0758 (GCVE-0-2022-0758)

Vulnerability from cvelistv5 – Published: 2022-03-17 22:30 – Updated: 2024-09-16 20:26
VLAI?
Title
Rapid7 Nexpose Reflected XSS
Summary
Rapid7 Nexpose versions 6.6.129 and earlier suffer from a reflected cross site scripting vulnerability, within the shared scan configuration component of the tool. With this vulnerability an attacker could pass literal values as the test credentials, providing the opportunity for a potential XSS attack. This issue is fixed in Rapid7 Nexpose version 6.6.130.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 6.6.129 , ≤ 6.6.129 (custom)
Create a notification for this product.
Credits
Aleksey Solovev
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T23:40:03.529Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20220309/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.129",
              "status": "affected",
              "version": "6.6.129",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Aleksey Solovev"
        }
      ],
      "datePublic": "2022-03-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Rapid7 Nexpose versions 6.6.129 and earlier suffer from a reflected cross site scripting vulnerability, within the shared scan configuration component of the tool. With this vulnerability an attacker could pass literal values as the test credentials, providing the opportunity for a potential XSS attack. This issue is fixed in Rapid7 Nexpose version 6.6.130."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-17T22:30:19",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20220309/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Nexpose Reflected XSS",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2022-03-09T00:00:00.000Z",
          "ID": "CVE-2022-0758",
          "STATE": "PUBLIC",
          "TITLE": "Rapid7 Nexpose Reflected XSS"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "\u003c=",
                            "version_name": "6.6.129",
                            "version_value": "6.6.129"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "configuration": [],
        "credit": [
          {
            "lang": "eng",
            "value": "Aleksey Solovev"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose versions 6.6.129 and earlier suffer from a reflected cross site scripting vulnerability, within the shared scan configuration component of the tool. With this vulnerability an attacker could pass literal values as the test credentials, providing the opportunity for a potential XSS attack. This issue is fixed in Rapid7 Nexpose version 6.6.130."
            }
          ]
        },
        "exploit": [],
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.rapid7.com/release-notes/nexpose/20220309/",
              "refsource": "CONFIRM",
              "url": "https://docs.rapid7.com/release-notes/nexpose/20220309/"
            }
          ]
        },
        "solution": [],
        "source": {
          "advisory": "",
          "defect": [],
          "discovery": "UNKNOWN"
        },
        "work_around": []
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2022-0758",
    "datePublished": "2022-03-17T22:30:19.550927Z",
    "dateReserved": "2022-02-24T00:00:00",
    "dateUpdated": "2024-09-16T20:26:23.589Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-0757 (GCVE-0-2022-0757)

Vulnerability from cvelistv5 – Published: 2022-03-17 22:30 – Updated: 2024-09-16 17:48
VLAI?
Title
Rapid7 Nexpose SQL Injection
Summary
Rapid7 Nexpose versions 6.6.93 and earlier are susceptible to an SQL Injection vulnerability, whereby valid search operators are not defined. This lack of validation can allow a logged-in, authenticated attacker to manipulate the "ANY" and "OR" operators in the SearchCriteria and inject SQL code. This issue was fixed in Rapid7 Nexpose version 6.6.129.
CWE
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 6.6.93 , < 6.6.93 (custom)
Create a notification for this product.
Credits
Aleksey Solovev
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T23:40:03.752Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20220302/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.93",
              "status": "affected",
              "version": "6.6.93",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Aleksey Solovev"
        }
      ],
      "datePublic": "2022-03-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Rapid7 Nexpose versions 6.6.93 and earlier are susceptible to an SQL Injection vulnerability, whereby valid search operators are not defined. This lack of validation can allow a logged-in, authenticated attacker to manipulate the \"ANY\" and \"OR\" operators in the SearchCriteria and inject SQL code. This issue was fixed in Rapid7 Nexpose version 6.6.129."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 SQL Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-04T14:35:09",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20220302/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Nexpose SQL Injection",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2022-03-02T00:00:00.000Z",
          "ID": "CVE-2022-0757",
          "STATE": "PUBLIC",
          "TITLE": "Rapid7 Nexpose SQL Injection"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "\u003c",
                            "version_name": "6.6.93",
                            "version_value": "6.6.93"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "configuration": [],
        "credit": [
          {
            "lang": "eng",
            "value": "Aleksey Solovev"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose versions 6.6.93 and earlier are susceptible to an SQL Injection vulnerability, whereby valid search operators are not defined. This lack of validation can allow a logged-in, authenticated attacker to manipulate the \"ANY\" and \"OR\" operators in the SearchCriteria and inject SQL code. This issue was fixed in Rapid7 Nexpose version 6.6.129."
            }
          ]
        },
        "exploit": [],
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89 SQL Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.rapid7.com/release-notes/nexpose/20220302/",
              "refsource": "CONFIRM",
              "url": "https://docs.rapid7.com/release-notes/nexpose/20220302/"
            }
          ]
        },
        "solution": [],
        "source": {
          "advisory": "",
          "defect": [],
          "discovery": "UNKNOWN"
        },
        "work_around": []
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2022-0757",
    "datePublished": "2022-03-17T22:30:18.220701Z",
    "dateReserved": "2022-02-24T00:00:00",
    "dateUpdated": "2024-09-16T17:48:14.153Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5640 (GCVE-0-2019-5640)

Vulnerability from cvelistv5 – Published: 2021-11-22 16:35 – Updated: 2024-09-17 00:15
VLAI?
Title
Rapid7 Nexpose Information Disclosure after logout
Summary
Rapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user's session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user
CWE
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 1.0 , ≤ 6.6.114 (custom)
Create a notification for this product.
Credits
Ashutosh Barot
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:01:52.022Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20211117/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.114",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Ashutosh Barot"
        }
      ],
      "datePublic": "2021-11-17T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eRapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user\u0027s session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user\u003c/p\u003e"
            }
          ],
          "value": "Rapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user\u0027s session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-10T10:10:18.015Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20211117/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Nexpose Information Disclosure after logout",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2021-11-17T15:05:00.000Z",
          "ID": "CVE-2019-5640",
          "STATE": "PUBLIC",
          "TITLE": "Rapid7 Nexpose Information Disclosure after logout"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "6.6.114",
                            "version_value": "6.6.114"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user\u0027s session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200 Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.rapid7.com/release-notes/nexpose/20211117/",
              "refsource": "CONFIRM",
              "url": "https://docs.rapid7.com/release-notes/nexpose/20211117/"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2019-5640",
    "datePublished": "2021-11-22T16:35:10.539066Z",
    "dateReserved": "2019-01-07T00:00:00",
    "dateUpdated": "2024-09-17T00:15:52.087Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31868 (GCVE-0-2021-31868)

Vulnerability from cvelistv5 – Published: 2021-08-19 15:25 – Updated: 2024-09-17 01:16
VLAI?
Title
Rapid7 Nexpose Security Console Ticket Access Authentication Vulnerability
Summary
Rapid7 Nexpose version 6.6.95 and earlier allows authenticated users of the Security Console to view and edit any ticket in the legacy ticketing feature, regardless of the assignment of the ticket. This issue was resolved in version 6.6.96, released on August 4, 2021.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: 6.6.95 , ≤ 6.6.95 (custom)
Create a notification for this product.
Credits
Reda El Hachloufi
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.651Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20210804/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.6.95",
              "status": "affected",
              "version": "6.6.95",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Reda El Hachloufi"
        }
      ],
      "datePublic": "2021-08-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Rapid7 Nexpose version 6.6.95 and earlier allows authenticated users of the Security Console to view and edit any ticket in the legacy ticketing feature, regardless of the assignment of the ticket. This issue was resolved in version 6.6.96, released on August 4, 2021."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-19T15:25:10",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20210804/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Rapid7 Nexpose Security Console Ticket Access Authentication Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2021-08-04T17:00:00.000Z",
          "ID": "CVE-2021-31868",
          "STATE": "PUBLIC",
          "TITLE": "Rapid7 Nexpose Security Console Ticket Access Authentication Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "6.6.95",
                            "version_value": "6.6.95"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Reda El Hachloufi"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose version 6.6.95 and earlier allows authenticated users of the Security Console to view and edit any ticket in the legacy ticketing feature, regardless of the assignment of the ticket. This issue was resolved in version 6.6.96, released on August 4, 2021."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306 Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.rapid7.com/release-notes/nexpose/20210804/",
              "refsource": "CONFIRM",
              "url": "https://docs.rapid7.com/release-notes/nexpose/20210804/"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2021-31868",
    "datePublished": "2021-08-19T15:25:10.545322Z",
    "dateReserved": "2021-04-28T00:00:00",
    "dateUpdated": "2024-09-17T01:16:12.557Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-3535 (GCVE-0-2021-3535)

Vulnerability from cvelistv5 – Published: 2021-06-16 01:40 – Updated: 2024-09-16 23:10
VLAI?
Summary
Rapid7 Nexpose is vulnerable to a non-persistent cross-site scripting vulnerability affecting the Security Console's Filtered Asset Search feature. A specific search criterion and operator combination in Filtered Asset Search could have allowed a user to pass code through the provided search field. This issue affects version 6.6.80 and prior, and is fixed in 6.6.81. If your Security Console currently falls on or within this affected version range, ensure that you update your Security Console to the latest version.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Rapid7 Nexpose Affected: unspecified , < 6.6.81 (custom)
Create a notification for this product.
Credits
This issue was discovered and reported by Philipp Behmer.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:01:07.112Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/release-notes/nexpose/20210505/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rapid7 Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.81",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This issue was discovered and reported by Philipp Behmer."
        }
      ],
      "datePublic": "2021-05-06T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Rapid7 Nexpose is vulnerable to a non-persistent cross-site scripting vulnerability affecting the Security Console\u0027s Filtered Asset Search feature. A specific search criterion and operator combination in Filtered Asset Search could have allowed a user to pass code through the provided search field. This issue affects version 6.6.80 and prior, and is fixed in 6.6.81. If your Security Console currently falls on or within this affected version range, ensure that you update your Security Console to the latest version."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-16T01:40:12",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.rapid7.com/release-notes/nexpose/20210505/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2021-05-06T00:00:00.000Z",
          "ID": "CVE-2021-3535",
          "STATE": "PUBLIC",
          "TITLE": ""
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rapid7 Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "\u003c",
                            "version_name": "",
                            "version_value": "6.6.81"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "configuration": [],
        "credit": [
          {
            "lang": "eng",
            "value": "This issue was discovered and reported by Philipp Behmer."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose is vulnerable to a non-persistent cross-site scripting vulnerability affecting the Security Console\u0027s Filtered Asset Search feature. A specific search criterion and operator combination in Filtered Asset Search could have allowed a user to pass code through the provided search field. This issue affects version 6.6.80 and prior, and is fixed in 6.6.81. If your Security Console currently falls on or within this affected version range, ensure that you update your Security Console to the latest version."
            }
          ]
        },
        "exploit": [],
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.rapid7.com/release-notes/nexpose/20210505/",
              "refsource": "CONFIRM",
              "url": "https://docs.rapid7.com/release-notes/nexpose/20210505/"
            }
          ]
        },
        "solution": [],
        "source": {
          "advisory": "",
          "defect": [],
          "discovery": "UNKNOWN"
        },
        "work_around": []
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2021-3535",
    "datePublished": "2021-06-16T01:40:12.586548Z",
    "dateReserved": "2021-05-05T00:00:00",
    "dateUpdated": "2024-09-16T23:10:39.986Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7383 (GCVE-0-2020-7383)

Vulnerability from cvelistv5 – Published: 2020-10-14 19:45 – Updated: 2024-09-16 20:31
VLAI?
Title
SQL Injection in Rapid7 Nexpose
Summary
A SQL Injection issue in Rapid7 Nexpose version prior to 6.6.49 that may have allowed an authenticated user with a low permission level to access resources & make changes they should not have been able to access.
CWE
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: unspecified , < 6.6.49 (custom)
Create a notification for this product.
Credits
This issue was discovered and reported by Mikhail Klyuchnikov of Positive Technologies.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:25:49.045Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.49"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.49",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This issue was discovered and reported by Mikhail Klyuchnikov of Positive Technologies."
        }
      ],
      "datePublic": "2020-10-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A SQL Injection issue in Rapid7 Nexpose version prior to 6.6.49 that may have allowed an authenticated user with a low permission level to access resources \u0026 make changes they should not have been able to access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 SQL Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-10-14T19:45:15",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.49"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "SQL Injection in Rapid7 Nexpose",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2020-10-14T11:23:00.000Z",
          "ID": "CVE-2020-7383",
          "STATE": "PUBLIC",
          "TITLE": "SQL Injection in Rapid7 Nexpose"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "6.6.49"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This issue was discovered and reported by Mikhail Klyuchnikov of Positive Technologies."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A SQL Injection issue in Rapid7 Nexpose version prior to 6.6.49 that may have allowed an authenticated user with a low permission level to access resources \u0026 make changes they should not have been able to access."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89 SQL Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.49",
              "refsource": "MISC",
              "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.49"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2020-7383",
    "datePublished": "2020-10-14T19:45:15.276787Z",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-09-16T20:31:39.664Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7382 (GCVE-0-2020-7382)

Vulnerability from cvelistv5 – Published: 2020-09-03 13:55 – Updated: 2024-08-04 09:25
VLAI?
Title
Unquoted Path in Rapid7 Nexpose Installer
Summary
Rapid7 Nexpose installer version prior to 6.6.40 contains an Unquoted Search Path which may allow an attacker on the local machine to insert an arbitrary file into the executable path. This issue affects: Rapid7 Nexpose versions prior to 6.6.40.
CWE
  • CWE-428 - Unquoted Search Path or Element
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: unspecified , < 6.6.40 (custom)
Create a notification for this product.
Credits
This issue was discovered and reported by Angelo D'Amato.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:25:49.039Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.40",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This issue was discovered and reported by Angelo D\u0027Amato. "
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Rapid7 Nexpose installer version prior to 6.6.40 contains an Unquoted Search Path which may allow an attacker on the local machine to insert an arbitrary file into the executable path. This issue affects: Rapid7 Nexpose versions prior to 6.6.40."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-428",
              "description": "CWE-428 Unquoted Search Path or Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-09-03T13:55:26",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Unquoted Path in Rapid7 Nexpose Installer",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "ID": "CVE-2020-7382",
          "STATE": "PUBLIC",
          "TITLE": "Unquoted Path in Rapid7 Nexpose Installer"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "6.6.40"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This issue was discovered and reported by Angelo D\u0027Amato. "
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose installer version prior to 6.6.40 contains an Unquoted Search Path which may allow an attacker on the local machine to insert an arbitrary file into the executable path. This issue affects: Rapid7 Nexpose versions prior to 6.6.40."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-428 Unquoted Search Path or Element"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40",
              "refsource": "MISC",
              "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2020-7382",
    "datePublished": "2020-09-03T13:55:26",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:25:49.039Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7381 (GCVE-0-2020-7381)

Vulnerability from cvelistv5 – Published: 2020-09-03 13:55 – Updated: 2024-08-04 09:25
VLAI?
Title
Code Injection in Rapid7 Nexpose Installer
Summary
In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: unspecified , < 6.6.40 (custom)
Create a notification for this product.
Credits
This issue was discovered and reported by Mishra Dhiraj.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:25:49.053Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "6.6.40",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This issue was discovered and reported by Mishra Dhiraj. "
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-09-03T13:55:25",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Code Injection in Rapid7 Nexpose Installer",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "ID": "CVE-2020-7381",
          "STATE": "PUBLIC",
          "TITLE": "Code Injection in Rapid7 Nexpose Installer"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "6.6.40"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This issue was discovered and reported by Mishra Dhiraj. "
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40",
              "refsource": "MISC",
              "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2020-7381",
    "datePublished": "2020-09-03T13:55:25",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:25:49.053Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2012-6494 (GCVE-0-2012-6494)

Vulnerability from cvelistv5 – Published: 2020-01-25 18:41 – Updated: 2024-08-06 21:28
VLAI?
Summary
Rapid7 Nexpose before 5.5.4 contains a session hijacking vulnerability which allows remote attackers to capture a user's session and gain unauthorized access.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T21:28:39.951Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "57150",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/57150"
          },
          {
            "name": "80982",
            "tags": [
              "vdb-entry",
              "x_refsource_XF",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/80982"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-01-05T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Rapid7 Nexpose before 5.5.4 contains a session hijacking vulnerability which allows remote attackers to capture a user\u0027s session and gain unauthorized access."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-25T18:41:34",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "57150",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/57150"
        },
        {
          "name": "80982",
          "tags": [
            "vdb-entry",
            "x_refsource_XF"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/80982"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2012-6494",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose before 5.5.4 contains a session hijacking vulnerability which allows remote attackers to capture a user\u0027s session and gain unauthorized access."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "57150",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/57150"
            },
            {
              "name": "80982",
              "refsource": "XF",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/80982"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2012-6494",
    "datePublished": "2020-01-25T18:41:34",
    "dateReserved": "2013-01-02T00:00:00",
    "dateUpdated": "2024-08-06T21:28:39.951Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5638 (GCVE-0-2019-5638)

Vulnerability from cvelistv5 – Published: 2019-08-21 19:36 – Updated: 2024-09-16 22:25
VLAI?
Title
Rapid7 Nexpose Insufficient Session Management
Summary
Rapid7 Nexpose versions 6.5.50 and prior suffer from insufficient session expiration when an administrator performs a security relevant edit on an existing, logged on user. For example, if a user's password is changed by an administrator due to an otherwise unrelated credential leak, that user account's current session is still valid after the password change, potentially allowing the attacker who originally compromised the credential to remain logged in and able to cause further damage.
CWE
  • CWE-613 - Insufficient Session Expiration
Assigner
Impacted products
Vendor Product Version
Rapid7 Nexpose Affected: unspecified , ≤ 6.5.50 (custom)
Create a notification for this product.
Credits
This issue was discovered, and reported to Rapid7, by independent researcher Ashutosh Barot. It is being disclosed in accordance with Rapid7's vulnerability disclosure policy (https://www.rapid7.com/disclosure/).
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:01:52.192Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://help.rapid7.com/nexpose/en-us/release-notes/archive/2019/02/"
          },
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://docs.rapid7.com/insightvm/enable-insightvm-platform-login"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nexpose",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThanOrEqual": "6.5.50",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "This issue was discovered, and reported to Rapid7, by independent researcher Ashutosh Barot. It is being disclosed in accordance with Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
        }
      ],
      "datePublic": "2019-08-14T23:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eRapid7 Nexpose versions 6.5.50 and prior suffer from insufficient session expiration when an administrator performs a security relevant edit on an existing, logged on user. For example, if a user\u0027s password is changed by an administrator due to an otherwise unrelated credential leak, that user account\u0027s current session is still valid after the password change, potentially allowing the attacker who originally compromised the credential to remain logged in and able to cause further damage.\u003c/p\u003e"
            }
          ],
          "value": "Rapid7 Nexpose versions 6.5.50 and prior suffer from insufficient session expiration when an administrator performs a security relevant edit on an existing, logged on user. For example, if a user\u0027s password is changed by an administrator due to an otherwise unrelated credential leak, that user account\u0027s current session is still valid after the password change, potentially allowing the attacker who originally compromised the credential to remain logged in and able to cause further damage."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-613",
              "description": "CWE-613 Insufficient Session Expiration",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-09T15:34:58.318Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://help.rapid7.com/nexpose/en-us/release-notes/archive/2019/02/"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://docs.rapid7.com/insightvm/enable-insightvm-platform-login"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThis issue is resolved in versions 6.5.51 and later of Rapid7 Nexpose.\u003c/p\u003e"
            }
          ],
          "value": "This issue is resolved in versions 6.5.51 and later of Rapid7 Nexpose."
        }
      ],
      "source": {
        "advisory": "R7-2018-50",
        "discovery": "EXTERNAL"
      },
      "title": "Rapid7 Nexpose Insufficient Session Management",
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2019-08-15T15:00:00.000Z",
          "ID": "CVE-2019-5638",
          "STATE": "PUBLIC",
          "TITLE": "Rapid7 Nexpose Insufficient Session Management"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nexpose",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "6.5.50"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rapid7"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This issue was discovered, and reported to Rapid7, by independent researcher Ashutosh Barot. It is being disclosed in accordance with Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rapid7 Nexpose versions 6.5.50 and prior suffer from insufficient session expiration when an administrator performs a security relevant edit on an existing, logged on user. For example, if a user\u0027s password is changed by an administrator due to an otherwise unrelated credential leak, that user account\u0027s current session is still valid after the password change, potentially allowing the attacker who originally compromised the credential to remain logged in and able to cause further damage."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-613 Insufficient Session Expiration"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://help.rapid7.com/nexpose/en-us/release-notes/archive/2019/02/",
              "refsource": "CONFIRM",
              "url": "https://help.rapid7.com/nexpose/en-us/release-notes/archive/2019/02/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "This issue is resolved in versions 6.5.51 and later of Rapid7 Nexpose."
          }
        ],
        "source": {
          "advisory": "R7-2018-50",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2019-5638",
    "datePublished": "2019-08-21T19:36:25.675225Z",
    "dateReserved": "2019-01-07T00:00:00",
    "dateUpdated": "2024-09-16T22:25:03.188Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",